Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLOW MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Fluid dynamics and low gravity effects of chemical vapor deposition

Based on the comparison between experimental data and numerical results for the growth of GaAs from TMGa, it was shown that 3D simulations are necessary to simulate rectangular CVD reactors even when operated under subcritical (Ra) conditions. The important points found are summarized in the three attached reprints. The experimental studies of mixed convection in horizontal channels have shown three regimes of high Ra (22,220) number flows. At Re = 18.5, the rolls develop very quickly, significantly modulating the axial velocity even before it reaches the beginning of the hot plate. A few centimeters downstream, the velocities become asymmetric about the vertical centerplane and at x = 12 cm, become unsteady. These asymmetries were predicted theoretically, but experimental evidence has not been published prior to this work. At Re = 36, the axial velocity is only slightly modified at x = 0. Although the flow remains steady and symmetric about the vertical centerplane, there is a small spatial oscillation in the velocities over the length of the channel. The period of this oscillation was around 5 cm. At Re = 54, the longitudinal rolls developed smoothly over a length of 30 cm, with no asymmetries, unsteadiness, or spatial oscillations. Comparison of numerical simulations of these flows to experiments has revealed the importance and difficulty of setting proper thermal boundary conditions on the sidewalls. Calculated flows and experimentally measured flows showed very similar profiles, but at different axial locations, with the rolls developing more rapidly in the experiments. This is directly attributable to partially conducting sidewalls of the apparatus being hotter in the entrance section than the adiabatic walls of the simulations. A thorough comparison of the experimental data and numerical results for a variety of sidewall boundary conditions is in preparation.

Nyce, Thomas A.↗

Capacitance probe for fluid flow and volume measurements

Method and apparatus for making measurements on fluids are disclosed, including the use of a capacitive probe for measuring the flow volume of a material within a flow stream. The capacitance probe has at least two elongate electrodes and, in a specific embodiment of the invention, has three parallel elongate electrodes with the center electrode being an extension of the center conductor of a co-axial cable. A conductance probe is also provided to provide more accurate flow volume data in response to conductivity of the material within the flow stream. A preferred embodiment of the present invention provides for a gas flow stream through a microgravity environment that allows for monitoring a flow volume of a fluid sample, such as a urine sample, that is entrained within the gas flow stream.

Arndt, G. Dickey↗

Capacitance Probe for Fluid Flow and Volume Measurements

Method and apparatus for making measurements on fluids are disclosed, including the use of a capacitive probe for measuring the flow volume of a material within a flow stream. The capacitance probe has at least two elongate electrodes and, in a specific embodiment of the invention, has three parallel elongate electrodes with the center electrode being an extension of the center conductor of a co-axial cable. A conductance probe is also provided to provide more accurate flow volume data in response to conductivity of the material within the flow stream. A preferred embodiment of the present invention provides for a gas flow stream through a micro-gravity environment that allows for monitoring a flow volume of a fluid sample, such as a urine sample, that is entrained within the gas flow stream.

Arndt, G. Dickey↗

A Programmable System for Motion Control

The need for improved flow measurements in the flow path of aeronautics testing facilities has led the NASA Glenn Research Center to develop a new motion control system. The new system is programmable, offering a flexibility unheard of in previous systems. The motion control system is PLC-based, which leads to highly accurate positioning ability, as well as reliability. The user interface is a software-based HMI package, which also adds flexibility to the overall system. The system also has the ability to create and execute motion profiles. This paper discusses the system's operation, control implementation, and experiences.

Nowlin, Brent C.↗

Unstructured CFD Aerodynamic Analysis of a Generic UCAV Configuration

Three independent studies from the United States (NASA), Sweden (FOI), and Australia (DSTO) are analyzed to assess the state of current unstructured-grid computational fluid dynamic tools and practices for predicting the complex static and dynamic aerodynamic and stability characteristics of a generic 53-degree swept, round-leading-edge uninhabited combat air vehicle configuration, called SACCON. NASA exercised the USM3D tetrahedral cell-centered flow solver, while FOI and DSTO applied the FOI/EDGE general-cell vertex-based solver. The authors primarily employ the Reynolds Averaged Navier-Stokes (RANS) assumption, with a limited assessment of the EDGE Detached Eddy Simulation (DES) extension, to explore sensitivities to grids and turbulence models. Correlations with experimental data are provided for force and moments, surface pressure, and off-body flow measurements. The vortical flow field over SACCON proved extremely difficult to model adequately. As a general rule, the prospect of obtaining reasonable correlations of SACCON pitching moment characteristics with the RANS formulation is not promising, even for static cases. Yet, dynamic pitch oscillation results seem to produce a promising characterization of shapes for the lift and pitching moment hysteresis curves. Future studies of this configuration should include more investigation with higher-fidelity turbulence models, such as DES.

Frink, Neal T.↗

THX Experiment Overview

This presentation provides an overview of experiments conducted at NASA GRC to provide turbulent flow measurements needed for new turbulence model development and validation. The experiments include particle image velocimetry (PIV) and hot-wire measurements of mean flow velocity and temperature fields, as well as fluctuating components.

heat transfer↗

Three-Dimensional Structure and Modeling of a Normal Bifurcated Shock Train from Experimental Measurements

An asymmetric, normal bifurcated shock train in a Mach 2 constant area, rectangular duct is investigated in the University of Michigan Direct Connect Isolator facility. High-speed schlieren imaging, wall static pressure measurements, surface oil flow visualization, and particle image velocimetry of the shock train are synthesized into a three-dimensional representation. This visualization is then used to inform the underlying flow physics of the distributed fluid dynamical processes along the shock train. The detailed, three-dimensional morphology of the flow profile entering the shock train is shown to have a significant impact on the separated flow morphology of the shock train. This results in a skewed supersonic core flow with alternating separation bubbles in the surrounding boundary layers. Finally, the efficacy of the prevailing pseudo-shock models in the literature is analyzed with the support of the available flow measurements. None are found to model both the pressure and streamwise Mach number profile of the UMDCI pseudo-shock. Note: This presentation is accompanied by the video presentation that can be downloaded for viewing and is formatted as an mp4 with a runtime of 10 min 15 secs.

Hypersonics↗

An evaluation of the method for determining the Whitham F-function using distributions of downwash and sidewash angles

The method of computing the Whitham F function using distributions of downwash and sidewash angles was evaluated with two different models. F functions which were calculated for a half angle cone cylinder at M infinites = 2.01, using theoretically and experimentally derived flow angles, show that the method is sensitive to small inaccuracies in the measured flow angles. An oblique wing transport model was tested at 0 deg angle of attack at M infinitely = 2.01. In this test, two different probes were used at two different distances from the model. The pressure signature derived from the F function was extrapolated and compared to the pressure signature measured at the distance of 0.87 body lengths with the static pressure probe. The agreement between the two pressure signatures was poor due to the many inaccuracies involved in using a probe designed to measure flow angularity.

Mendoza, J. P.↗

Detailed flow-field measurements over a 75 deg swept delta wing

Results from an experimental investigation documenting the flowfield over a 75 deg swept delta wing at an angle-of-attack of 20.5 deg are presented. Results obtained include surface flow visualization, off-body flow visualization, and detailed flowfield surveys for various Reynolds numbers. Flowfield surveys at Reynolds numbers of 0.5, 1.0, and 1.5 million based on the root chord were conducted with both a Pitot pressure probe and a 5-hole pressure probe; and 3-component laser velocimeter surveys were conducted at a Reynolds number of 1.0 million. The Pitot pressure surveys were obtained at 5 chordwise stations, the 5-hole probe surveys were obtained at 3 chordwise stations and the laser velocimeter surveys were obtained at one station. The results confirm the classical roll up of the flow into a pair of primary vortices over the delta wing. The velocity measurements indicate that Reynolds number has little effect on the global structure of the flowfield for the Reynolds number range investigated. Measurements of the non-dimensional axial velocity in the core of the vortex indicate a jet like flow with values greater than twice freestream. Comparisons between velocity measurements from the 5-hole pressure probe and the laser velocimeter indicate that the pressure probe does a reasonable job of measuring the flowfield quantities where the velocity gradients in the flowfield are low.

Kjelgaard, Scott O.↗

Unified Model Deformation and Flow Transition Measurements

The number of optical techniques that may potentially be used during a given wind tunnel test is continually growing. These include parameter sensitive paints that are sensitive to temperature or pressure, several different types of off-body and on-body flow visualization techniques, optical angle-of-attack (AoA), optical measurement of model deformation, optical techniques for determining density or velocity, and spectroscopic techniques for determining various flow field parameters. Often in the past the various optical techniques were developed independently of each other, with little or no consideration for other techniques that might also be used during a given test. Recently two optical techniques have been increasingly requested for production measurements in NASA wind tunnels. These are the video photogrammetric (or videogrammetric) technique for measuring model deformation known as the video model deformation (VMD) technique, and the parameter sensitive paints for making global pressure and temperature measurements. Considerations for, and initial attempts at, simultaneous measurements with the pressure sensitive paint (PSP) and the videogrammetric techniques have been implemented. Temperature sensitive paint (TSP) has been found to be useful for boundary-layer transition detection since turbulent boundary layers convect heat at higher rates than laminar boundary layers of comparable thickness. Transition is marked by a characteristic surface temperature change wherever there is a difference between model and flow temperatures. Recently, additional capabilities have been implemented in the target-tracking videogrammetric measurement system. These capabilities have permitted practical simultaneous measurements using parameter sensitive paint and video model deformation measurements that led to the first successful unified test with TSP for transition detection in a large production wind tunnel.

Burner, Alpheus W.↗

Support of gas flowmeter upgrade

A project history review, literature review, and vendor search were conducted to identify a flowmeter that would improve the accuracy of gaseous flow measurements in the White Sands Test Facility (WSTF) Calibration Laboratory and the Hydrogen High Flow Facility. Both facilities currently use sonic flow nozzles to measure flowrates. The flow nozzle pressure drops combined with corresponding pressure and temperature measurements have been estimated to produce uncertainties in flowrate measurements of 2 to 5 percent. This study investigated the state of flowmeter technology to make recommendations that would reduce those uncertainties. Most flowmeters measure velocity and volume, therefore mass flow measurement must be calculated based on additional pressures and temperature measurement which contribute to the error. The two exceptions are thermal dispersion meters and Coriolis mass flowmeters. The thermal dispersion meters are accurate to 1 to 5 percent. The Coriolis meters are significantly more accurate, at least for liquids. For gases, there is evidence they may be accurate to within 0.5 percent or better of the flowrate, but there may be limitations due to inappropriate velocity, pressure, Mach number and vibration disturbances. In this report, a comparison of flowmeters is presented. Candidate Coriolis meters and a methodology to qualify the meter with tests both at WSTF and Southwest Research Institute are recommended and outlined.

Waugaman, Dennis↗

Flow field measurements in a 90 degree turning duct

The objective of this investigation is the experimental evaluation of the influence of inlet turbulence intensity on secondary flow development in a turning duct. The existing 25.4 cm square turning duct (90) facility is being utilized to investigate of bulk turbulence levels on secondary flow development. The large scale duct flow facility allows detailed mean velocity and turbulence quantities to be measured at several streamwise planes in the curved duct. Non-intrusive laser velocimetry is being used to measure the mean and fluctuating components of velocity in all three orthogonal directions. To assure that the turbulence measurements are unbiased by particle lag and other effects, comparison hot wire data will be taken to validate the laser velocimetry system calibration.

Crawford, Roger A.↗

Impeller flow field measurement and analysis

A series of experiments are performed to investigate and quantify the three-dimensional mean flow field in centrifugal compressor flow passages and to evaluate contemporary internal flow models. The experiments include the acquisition and analysis of LDV data in the impeller passages of a low-speed moderate-scale research mixed-flow centrifugal compressor operating at its design point. Predictions from a viscous internal flow model are then correlated with these data. The LDV data show the traditional jet-wake structure observed in many centrifugal compressors, with the wake observed along the shroud 70 percent of the length from the pressure to suction surface. The viscous model predicts the major flow phenomena. However, the correlations of the viscous predictions with the LDV data were poor.

Fagan, J. R.↗

Assessing the Capability of Doppler Global Velocimetry To Measure Vortical Flow Fields

A new nonintrusive flow diagnostics instrumentation system, Doppler global velocimetry, is presented. The system is capable of making simultaneous, three-component velocity measurements within a selected measurement plane at video camera rates. These velocity images can provide the researcher with spatial and temporal information about the flow field in a global sense. The investigation of a vortical flow above a 75-degree delta wing comparing standard three-component, fringe-type laser velocimetry measurements with Doppler global velocimetry measurements is presented.

Meyers, James F.↗

Measurement of post-separated flowfields on airfoils

A small combination pitch-yaw probe designed to facilitate measurement of post-separated flow fields on airfoils is described, along with its calibration. A five-tube probe is found 'ideally suited' to separated-flow measurements because of the pitch and yaw angle information provided in addition to static and total pressures. Wall proximity effects (in a low-speed tunnel) are described. Procedures for measurements in flows with small inclinations in pitch and yaw, for large flow angles, and for scanning flows with large inclinations are indicated.

Seetharam, H. C.↗

Laser Anemometer Measurements of the Flow Field in a 4:1 Pressure Ratio Centrifugal Impeller

A laser-doppler anemometer was used to obtain flow-field velocity measurements in a 4:1 pressure ratio, 4.54 kg/s (10 lbm/s), centrifugal impeller, with splitter blades and backsweep, which was configured with a vaneless diffuser. Measured through-flow velocities are reported for ten quasi-orthogonal survey planes at locations ranging from 1% to 99% of main blade chord. Measured through-flow velocities are compared to those predicted by a 3-D viscous steady flow analysis (Dawes) code. The measurements show the development and progression through the impeller and vaneless diffuser of a through-flow velocity deficit which results from the tip clearance flow and accumulation of low momentum fluid centrifuged from the blade and hub surfaces. Flow traces from the CFD analysis show the origin of this deficit which begins to grow in the inlet region of the impeller where it is first detected near the suction surface side of the passage. It then moves toward the pressure side of the channel, due to the movement of tip clearance flow across the impeller passage, where it is cut by the splitter blade leading edge. As blade loading increases toward the rear of the channel the deficit region is driven back toward the suction surface by the cross-passage pressure gradient. There is no evidence of a large wake region that might result from flow separation and the impeller efficiency is relatively high. The flow field in this impeller is quite similar to that documented previously by NASA Lewis in a large low-speed backswept impeller.

Skoch, G. J.↗

Measurement of Flow Pattern Within a Rotating Stall Cell in an Axial Compressor

Effective active control of rotating stall in axial compressors requires detailed understanding of flow instabilities associated with this compressor regime. Newly designed miniature high frequency response total and static pressure probes as well as commercial thermoanemometric probes are suitable tools for this task. However, during the rotating stall cycle the probes are subjected to flow direction changes that are far larger than the range of probe incidence acceptance, and therefore probe data without a proper correction would misrepresent unsteady variations of flow parameters. A methodology, based on ensemble averaging, is proposed to circumvent this problem. In this approach the ensemble averaged signals acquired for various probe setting angles are segmented, and only the sections for probe setting angles close to the actual flow angle are used for signal recombination. The methodology was verified by excellent agreement between velocity distributions obtained from pressure probe data, and data measured with thermoanemometric probes. Vector plots of unsteady flow behavior during the rotating stall regime indicate reversed flow within the rotating stall cell that spreads over to adjacent rotor blade channels. Results of this study confirmed that the NASA Low Speed Axial Compressor (LSAC) while in a rotating stall regime at rotor design speed exhibits one stall cell that rotates at a speed equal to 50.6 percent of the rotor shaft speed.

Lepicovsky, Jan↗