Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Research on biophysical evaluation of the human vestibular system

The human vestibular function was studied by the combined approach of advanced measurement and mathematical modelling. Fundamental measurements of some physical properties of endolymph and perilymph, combined with nystagmus measurements and fluid mechanical analysis of semicircular canal function furthered the theory of canal mechanical response to angular acceleration, caloric stimulation and relating linear acceleration. The effects of adaptation seen at low frequency angular stimulation were studied and modelled to remove some shortcomings of the torsion pendulum models. Otolith function was also studied experimentally and analytically, leading to a new set of models for subjective orientation. Applications to special problems of space, including the case of rotating spacecraft were investigated and the interaction of visual and vestibular cues and their relation to proprioceptive information was explored relative to postural control.

Young, L. R.↗

Program to stimulate graduate training in the field of aeroacoustics

An experiment is reported to cross correlate the output of hot film probes located at various points in the flow field of a jet-blown flap with the output of microphones in the acoustic far field. Fluid dynamic measurements of the flow fields of the test configuration are reported.

Becker, R. S.↗

Blast wave in a nozzle for propulsive applications

The reported investigation has been conducted in connection with studies concerning the development of a propulsion system based on the use of a detonating fluid propellant. Measurements have been made of the pressure and shock wave velocity in a conical nozzle at various ambient pressures and at an ambient temperature of 25 C. In the experiments a small amount of explosive was placed at the end wall of a conical aluminum nozzle and detonated by a microdetonator inside the nozzle. Differences regarding the characteristics of conventional chemical propulsion and detonation propulsion are illustrated with the aid of a graph. One- and two-dimensional numerical flow calculations were performed and compared with the experimental data.

Varsi, G.↗

A comparison of experimental and theoretical results for rotordynamic coefficients of four annular gas seals

The test facility and initial test program developed to experimentally measure the fluid forces induced by annular gas seals is described. A comparison of theoretically predicted and experimentally obtained data for smooth and honeycomb seals is provided. And a comparison of experimental data from the tests of three smooth-rotor/smooth-stator seals is provided. The leakage of the working fluid through the seal, the pressure gradient along the seal length, entrance pressure-loss data, and rotordynamic coefficients provide a basis for comparison. A short discussion on seal theory is included, and various rotordynamic coefficient identification schemes are described.

Childs, D. W.↗

Recent experience in seeding transonic/supersonic flows at AEDC

The laser velocimeter has been utilized for several years at the Arnold Engineering and Development Center (AEDC) as a flow diagnostics tool. Most applications, following the initial proof-of-concept experiments, have involved relatively complex unknown flow fields in which the more conventional, intrusive techniques had either not been attempted or had yielded unsatisfactory results. A blunt-base nozzle-afterbody base flow study is discussed as a respresentative example of such applications. A wide variety of problems have been encountered during these tests, many of which have proven to be closely related to the size and/or size distribution of the seeding material within the fluid. Resulting measurement uncertainties could often not be conclusively resolved because of the unknown nature of the flow field. The other experiments listed were conducted to provide known aerodynamic conditions for comparison with the velocimeter results.

Heltsley, F. L.↗

Plasma volume methodology: Evans blue, hemoglobin-hematocrit, and mass density transformations

Methods for measuring absolute levels and changes in plasma volume are presented along with derivations of pertinent equations. Reduction in variability of the Evans blue dye dilution technique using chromatographic column purification suggests that the day-to-day variability in the plasma volume in humans is less than + or - 20 m1. Mass density determination using the mechanical-oscillator technique provides a method for measuring vascular fluid shifts continuously for assessing the density of the filtrate, and for quantifying movements of protein across microvascular walls. Equations for the calculation of volume and density of shifted fluid are presented.

Greenleaf, J. E.↗

Physiologic adaptation of man in space; Proceedings of the Seventh International Man in Space Symposium, Houston, TX, Feb. 10-13, 1986

Topics discussed in this volume include space motion sickness, cardiovascular adaptation, fluid shifts, extravehicular activity, general physiology, perception, vestibular response modifications, vestibular physiology, and pharmacology. Papers are presented on the clinical characterization and etiology of space motion sickness, ultrasound techniques in space medicine, fluid shifts in weightlessness, Space Shuttle inflight and postflight fluid shifts measured by leg volume changes, and the probability of oxygen toxicity in an 8-psi space suit. Consideration is also given to the metabolic and hormonal status of crewmembers in short-term space flights, adaptive changes in perception of body orientation and mental image rotation in microgravity, the effects of a visual-vestibular stimulus on the vestibulo-ocular reflex, rotation tests in the weightless phase of parabolic flight, and the mechanisms of antimotion sickness drugs.

Holland, Albert W.↗

Clinical characterization and etiology of space motion sickness

An inflight, clinically-oriented investigation of space motion sickness (SMS) was begun on STS-4 and revealed the following: compared to motion sickness (MS) on earth, automatic signs are significantly different in SMS vs. MS in that sweating is not present, pallor or flushing may be present, and vomiting is episodic, sudden, and brief. Postflight there is a period of resistance to all forms of MS. There is some evidence for individual reduction in sensitivity on repeated flights. Electrooculogram, audio-evoked potentials, measurement of fluid shifts, and other studies are inconsistent with a transient vestibular hydrops or increased intracranial pressure as a cause.

Thornton, William E.↗

Digital image processing for quantification through full flow field tracing (FFFT) in narrow geometries at low Reynolds numbers

This paper introduces a computer based image processing technique to the field of nonintrusive velocity measurements in fluid mechanics. The method is presented with two alternatives: the first is involving intense interaction between the operator and the computer system; the second is a first generation artificial intelligence based system, where a set of initially imputed rules replaces the operator. The methods are applied to flow in narrow gaps.

Braun, M. J.↗

Radiographic instrumentation for DPM experiments

New developments in x-ray radiography that may be applicable to containerless experimentation are presented. The two features discussed are the use of radiography to determine the position and shape of the solid-liquid interface and, with the aid of appropriate markers, the flow patterns in either the surface or bulk of the liquid state. Both surface energy and fluid viscosity measurements can be made with the aid of the described radiographic system.

Fripp, Archie L.↗

Ground based preparation for microgravity growth of alloy semiconductors

Ground-based research conducted in order to prepare a microgravity space flight experiment is presented. The thermophysical properties of a PbSnTe alloy used for semiconductors are investigated, and furnace calibration and fluid-flow measurements are performed. The alloy has a zero energy crossing at approximately 40 percent SnTe in its band-gap vs composition diagram, which facilitates the design of long-wavelength IR detectors and lasers. The uniformity of devices made from this material depends on the ratio of PbTe and SnTe and requires the composition of the crystal growth to be closely controlled. The main obstacle to such control is the fact that liquid of this material is always solutally or thermally unstable, and, in a high-temperature gradient, the double convective instability cannot be made stable by balancing thermal and solutal expansion. In order to extend the science of crystal growth, the limits of suppression of convection have to be tested in low earth orbit.

Fripp, Archibald L.↗

Adaptive control of propellant slosh for a launch vehicle with multiple tanks

This paper discusses the use of an adaptive system to stabilize a multi-tank launch vehicle with sloshable fuel. The adaptive system utilizes a sensor to measure the fluid slosh angle, a recursive-least-squares estimator to estimate the natural frequency of the sloshing fuel, and a linear filter which stabilizes the unstable fuel slosh using the frequency estimate. Single-input and multiinput estimators were investigated. The time-varying complexity of the slosh control loop keeps the system persistently excited through flight, even though the attitude is controlled by a conventional PID controller. For the first portion of flight, the adaptive system maintains stability. A modification is proposed for latter portions of flight. The approach requires no tank baffles or partitions.

Saugen, John D.↗

Effects of prolonged head-down bed rest on physiological responses to moderate hypoxia

To determine the effects of hypoxia on physiological responses to simulated zero-gravity cardiopulmonary and fluid balance measurements were made in 6 subjects before and during 5-degree head-down bed rest (HDBR) over 8 d at 10,678 ft and a second time at this altitude as controls (CON). The V-dot(O2)(max) increased by 9 percent after CON, but fell 3 percent after HDBR. This reduction in work capacity during HDBR could be accounted for by inactivity. The heart rate response to a head-up tilt was greatly enhanced following HDBR, while mean blood pressure was lower. No significant negative impact of HDBR was noted on the ability to acclimatize to hypoxia in terms of pulmonary mechanics, gas exchange, circulatory or mental function measurements. No evidence of pulmonary interstitial edema or congestion was noted during HDBR at the lower PIO2 and blood rheology properties were not negatively altered. Symptoms of altitude illness were more prevalent, but not marked, during HDBR and arterial blood gases and oxygenation were not seriously effected by simulated microgravity. Declines in base excess with altitude were similar in both conditions. The study demonstrated a minimal effect of HDBR on the ability to adjust to this level of hypoxia.

Loeppky, J. A.↗

Experimental and analytical study of cryogenic propellant boiloff to develop and verify alternate pressurization concepts for Space Shuttle external tank using a scaled down tank

Self pressurization by propellant boiloff is experimentally studied as an alternate pressurization concept for the Space Shuttle external tank (ET). The experimental setup used in the study is an open flow system which is composed of a variable area test tank and a recovery tank. The vacuum jacketed test tank is geometrically similar to the external LOx tank for the Space Shuttle. It is equipped with instrumentation to measure the temperature and pressure histories within the liquid and vapor, and viewports to accommodate visual observations and Laser-Doppler Anemometry measurements of fluid velocities. A set of experiments were conducted using liquid Nitrogen to determine the temperature stratification in the liquid and vapor, and pressure histories of the vapor during sudden and continuous depressurization for various different boundary and initial conditions. The study also includes the development and calibration of a computer model to simulate the experiments. This model is a one-dimensional, multi-node type which assumes the liquid and the vapor to be under non-equilibrium conditions during the depressurization. It has been tested for a limited number of cases. The preliminary results indicate that the accuracy of the simulations is determined by the accuracy of the heat transfer coefficients for the vapor and the liquid at the interface which are taken to be the calibration parameters in the present model.

Akyuzlu, K. M.↗

Development of Lightweight Radiators for Lunar Based Power Systems

This report discusses application of a new lightweight carbon-carbon (C-C) space radiator technology developed under the NASA Civil-Space Technology Initiative (CSTI) High Capacity Power Program to a 20 kWe lunar based power system. This system comprises a nuclear (SP-100 derivative) heat source, a Closed Brayton Cycle (CBC) power conversion unit with heat rejection by means of a plane radiator. The new radiator concept is based on a C-C composite heat pipe with integrally woven fins and a thin walled metallic liner for containment of the working fluid. Using measured areal specific mass values (1.5 kg/m2) for flat plate radiators, comparative CBC power system mass and performance calculations show significant advantages if conventional heat pipes for space radiators are replaced by the new C-C heat pipe technology.

Juhasz, Albert J.↗

Surface Tension Driven Convection Experiment (STDCE)

Results are reported of the Surface Tension Driven Convection Experiment (STDCE) aboard the USML-1 (first United States Microgravity Laboratory) Spacelab which was launched on June 25, 1992. In the experiment 10 cSt silicone oil was placed in an open circular container which was 10 cm wide by 5 cm deep. The fluid was heated either by a cylindrical heater (1.11 cm dia.) located along the container centerline or by a CO2 laser beam to induce thermocapillary flow. The flow field was studied by flow visualization. Several thermistor probes were placed in the fluid to measure the temperature distribution. The temperature distribution along the liquid free surface was measured by an infrared imager. Tests were conducted over a range of heating powers, laser beam diameters, and free surface shapes. In conjunction with the experiments an extensive numerical modeling of the flow was conducted. In this paper some results of the velocity and temperature measurements with flat and curved free surfaces are presented and they are shown to agree well with the numerical predictions.

Ostrach, Simon↗

Thermally-included convection in confined air

This study includes the development and design of a space experiment for the investigation of the thermally-induced convection heat transfer process in an enclosure containing air. Various features of the design including the optical method used in the fluid temperature measurement are presented and discussed. A series of ground experiments were carried out in support of the in-space experiment design. Their results are discussed briefly and compared with numerical predictions.

Crocker, D. S.↗

Development of a Prediction Scheme for High Aspect-Ratio Jet Noise

Circulation control wings are a type of pneumatic high-lift device that have been extensively researched as to their aerodynamic benefits. However, there has been little research into the possible airframe noise reduction benefits of a circulation control wing. The key element of noise is the jet noise associated with the jet sheet emitted from the blowing slot. This jet sheet is essentially a high aspect-ratio rectangular jet. A recent study on high aspect-ratio jet noise was performed on a nozzle with aspect-ratios ranging from 100 to 3,000. In addition to the acoustic data, fluid dynamic measurements were made as well. This paper uses the results of these two studies and attempts to develop a prediction scheme for high aspect-ratio jet noise

Munro, Scott E.↗