Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUORESCENCE MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Elucidation of perovskite film micro-orientations using two-photon total internal reflectance fluorescence microscopy

The emergence of efficient hybrid organic-inorganic perovskite photovoltaic materials has caused the rapid development of a variety of preparation and processing techniques designed to maximize their performance. As processing methods continue to emerge, it is important to understand how the optical properties of these materials are affected on a microscopic scale. Here polarization resolved two-photon total internal reflectance microscopy (TIRFM) was used to probe changes in transition dipole moment orientation as a function of thermal annealing time in hybrid organic-inorganic lead iodide based perovskite (CH 3 NH 3 PbI 3 ) thin films on glass. These results show that as thermal annealing time is increased the distribution of transition moments pointing out-of-plane decreases in favor of forming areas with increased in-plane orientations. As a result, it was also shown through the axial sensitivity of TIRFM that the surface topography is manifested in the signal intensity and can be used to survey aspects of morphology in coincidence with the optical properties of these films.

36 MATERIALS SCIENCE↗

Super-resolution computational saturated absorption microscopy

Imaging beyond the diffraction limit barrier has attracted wide attention due to the ability to resolve previously hidden image features. Of the various super-resolution microscopy techniques available, a particularly simple method called saturated excitation microscopy (SAX) requires only simple modification of a laser scanning microscope: The illumination beam power is sinusoidally modulated and driven into saturation. SAX images are extracted from the harmonics of the modulation frequency and exhibit improved spatial resolution. Unfortunately, this elegant strategy is hindered by the incursion of shot noise that prevents high-resolution imaging in many realistic scenarios. Here, we demonstrate a technique for super-resolution imaging that we call computational saturated absorption (CSA) in which a joint deconvolution is applied to a set of images with diversity in spatial frequency support among the point spread functions (PSFs) used in the image formation with saturated laser scanning fluorescence microscopy. CSA microscopy allows access to the high spatial frequency diversity in a set of saturated effective PSFs, while avoiding image degradation from shot noise.

Murray, Gabe (ORCID:0000000295655485)↗

Entangled Photon Spectroscopy

Conspectus The enhanced interest in quantum-related phenomena has provided new opportunities for chemists to push the limits of detection and analysis of chemical processes. As some have called this the second quantum revolution, a time has come to apply the rules learned from previous research in quantum phenomena toward new methods and technologies important to chemists. While there has been great interest recently in quantum information science (QIS), the quest to understand how nonclassical states of light interact with matter has been ongoing for more than two decades. Our entry into this field started around this time with the use of materials to produce nonclassical states of light. Here, the process of multiphoton absorption led to photon-number squeezed states of light, where the photon statistics are sub-Poissonian. In addition to the great interest in generating squeezed states of light, there was also interest in the formation of entangled states of light. While much of the effort is still in foundational physics, there are numerous new avenues as to how quantum entanglement can be applied to spectroscopy, imaging, and sensing. These opportunities could have a large impact on the chemical community for a broad spectrum of applications. Here, we discuss the use of entangled (or quantum) light for spectroscopy as well as applications in microscopy and interferometry. The potential benefits of the use of quantum light are discussed in detail. From the first experiments in porphyrin dendrimer systems by Dr. Dong-Ik Lee in our group to the measurements of the entangled two photon absorption cross sections of biological systems such as flavoproteins, the usefulness of entangled light for spectroscopy has been illustrated. These early measurements led the way to more advanced measurements of the unique characteristics of both entangled light and the entangled photon absorption cross-section, which provides new control knobs for manipulating excited states in molecules. The first reports of fluorescence-induced entangled processes were in organic chromophores where the entangled photon cross-section was measured. These results would later have widespread impact in applications such as entangled two-photon microscopy. From our design, construction and implementation of a quantum entangled photon excited microscope, important imaging capabilities were achieved at an unprecedented low excitation intensity of 10 7 photons/s, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. New reports have also illustrated an advantage of nonclassical light in Raman imaging as well. From a standpoint of more precise measurements, the use of entangled photons in quantum interferometry may offer new opportunities for chemistry research. Experiments that combine molecular spectroscopy and quantum interferometry, by utilizing the correlations of entangled photons in a Hong–Ou–Mandel (HOM) interferometer, have been carried out. The initial experiment showed that the HOM signal is sensitive to the presence of a resonant organic sample placed in one arm of the interferometer. In addition, parameters such as the dephasing time have been obtained with the opportunity for even more advanced phenomenology in the future.

36 MATERIALS SCIENCE↗

Sensitive Fluorescent Determination of Cobalt by Microwave Assisted Synthesized TPTZ Functionalized Carbon Dots

Novel fluorescent carbon dots (CDs) for cobalt ions sensing were synthesized from 2,4,6-tris(2′-pyridyl)-s-triazine (TPTZ) and citric acid by microwave-assisted method in one pot. This sensor was water soluble, simple, sensitive and cheap. The size of the CDs was determined from transmission electron microscope image and was in the range of 10 nm. Under optimized experimental conditions, this luminescent system had stable response for Co (II) over a concentration range from 0.4 to 50 µM with a detection limit as low as 230 nM. The proposed method showed good sensitivity and selectivity with respect to interference ions. Finally, this system was used for Co (II) determination in tap water, river water and mineral water and B{sub 12} ampoule samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single molecule tracking of quantum dot-labeled mRNAs in a cell nucleus

Single particle tracking (SPT) is a powerful technique for studying mRNA dynamics in cells. Although SPT of mRNA has been performed by labeling mRNA with fluorescent dyes or proteins, observation of mRNA for long durations with high temporal resolution has been difficult due to weak fluorescence and rapid photobleaching. Using quantum dots (QDs), we succeeded in observing the movement of individual mRNAs for more than 60 s, with a temporal resolution of 30 ms. Intronless and truncated ftz mRNA, synthesized in vitro and labeled with QDs, was microinjected into the nuclei of Cos7 cells. Almost all mRNAs were in motion, and statistical analyses revealed anomalous diffusion between barriers, with a microscopic diffusion coefficient of 0.12 {mu}m{sup 2}/s and a macroscopic diffusion coefficient of 0.025 {mu}m{sup 2}/s. Diffusion of mRNA was observed in interchromatin regions but not in histone2B-GFP-labeled chromatin regions. These results provide direct evidence of channeled mRNA diffusion in interchromatin regions.

60 APPLIED LIFE SCIENCES↗

Microwave-Assisted Combustion Synthesis of ZnO:Eu Nanoparticles: Effect of Fuel Types

Nanoparticles of Europium oxide doped with Zinc oxide were synthesized via microwave-assisted combustion method. Citric acid as a simultaneous fuel and chelating agent and glycine as a fuel and mixture of these fuels were sleeted. X-Ray diffraction patterns (XRD) indicated the formation of ZnO structure with a few amount of Eu{sub 2}O{sub 3} phase. Fourier transformation infra red (FTIR) spectra reveal the increase of ZnO{sub 4} bonds with glycine content of fuels mixture. Scanning electron microscope (SEM) images showed the conversion of nanosphere to spongy-like structure with respect to change of fuel mixtures from citric to glycine. From transmission electron microscopy (TEM) nanoparticles of a mean size 30 nm are observed Green fluorescence emission of different samples was due to activation of self activated center of ZnO structure through transition of electron from Eu{sup 3+} to V{sub zn} sites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Single-cell correlations of mRNA and protein content in a human monocytic cell line after LPS stimulation

The heterogeneity of mRNA and protein expression at the single-cell level can reveal fundamental information about cellular response to external stimuli, including the sensitivity, timing, and regulatory interactions of genes. Here we describe a fully automated system to digitally count the intron, mRNA, and protein content of up to five genes of interest simultaneously in single-cells. Full system automation of 3D microscope scans and custom image analysis routines allows hundreds of individual cells to be automatically segmented and the mRNA-protein content to be digitally counted. Single-molecule intron and mRNA content is measured by single-molecule fluorescence in-situ hybridization (smFISH), while protein content is quantified though the use of antibody probes. To mimic immune response to bacterial infection, human monocytic leukemia cells (THP-1) were stimulated with lipopolysaccharide (LPS), and the expression of two inflammatory genes, IL1β (interleukin 1β) and TNF-α (tumor necrosis factor α), were simultaneously quantified by monitoring the intron, mRNA, and protein levels over time. The simultaneous labeling of cellular content allowed for a series of correlations at the single-cell level to be explored, both in the progressive maturation of a single gene (intron-mRNA-protein) and comparative analysis between the two immune response genes. In the absence of LPS stimulation, mRNA expression of IL1β and TNF-α were uncorrelated. Following LPS stimulation, mRNA expression of the two genes became more correlated, consistent with a model in which IL1β and TNF-α upregulation occurs in parallel through independent mechanistic pathways. This smFISH methodology can be applied to different complex biological systems to provide valuable insight into highly dynamic gene mechanisms that determine cell plasticity and heterogeneity of cellular response.

59 BASIC BIOLOGICAL SCIENCES↗

Coupling a recurrent neural network to SPAD TCSPC systems for real-time fluorescence lifetime imaging

Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. Inspired by the concept of Edge Artificial Intelligence (Edge AI), we propose a robust approach that enables fast FLI with no degradation of accuracy. This approach couples a recurrent neural network (RNN), which is trained to estimate the fluorescence lifetime directly from raw timestamps without building histograms, to SPAD TCSPC systems, thereby drastically reducing transfer data volumes and hardware resource utilization, and enabling real-time FLI acquisition. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in the presence of background noise by a large margin. To explore the ultimate limits of the approach, we derive the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. To demonstrate real-time operation, we build a FLI microscope based on an existing SPAD TCSPC system comprising a 32 x 32 SPAD sensor named Piccolo. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on the Xilinx Kintex-7 FPGA that controls the Piccolo. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications, including biological imaging, biomedical diagnostics, and fluorescence-assisted surgery, etc.

47 OTHER INSTRUMENTATION↗

Hyperdimensional Imaging Contrast Using an Optical Fiber

Fluorescence properties of a molecule can be used to study the structural and functional nature of biological processes. Physical properties, including fluorescence lifetime, emission spectrum, emission polarization, and others, help researchers probe a molecule, produce desired effects, and infer causes and consequences. Correlative imaging techniques such as hyperdimensional imaging microscopy (HDIM) combine the physical properties and biochemical states of a fluorophore. Here we present a fiber-based imaging system that can generate hyper-dimensional contrast by combining multiple fluorescence properties into a single fluorescence lifetime decay curve. Fluorescence lifetime imaging microscopy (FLIM) with controlled excitation polarization and temporally dispersed emission can generate a spectrally coded, polarization-filtered lifetime distribution for a pixel. This HDIM scheme generates a better contrast between different molecules than that from individual techniques. This setup uses only a single detector and is simpler to implement, modular, cost-efficient, and adaptable to any existing FLIM microscope. We present higher contrast data from Arabidopsis thaliana epidermal cells based on intrinsic anthocyanin emission properties under multiphoton excitation. This work lays the foundation for an alternative hyperdimensional imaging system and demonstrates that contrast-based imaging is useful to study cellular heterogeneity in biological samples.

47 OTHER INSTRUMENTATION↗

The INE-Beamline for actinide science at ANKA

Since its inauguration in 2005, the INE-Beamline for actinide research at the synchrotron source ANKA (KIT North Campus) provides dedicated instrumentation for x-ray spectroscopic characterization of actinide samples and other radioactive materials. R and D work at the beamline focuses on various aspects of nuclear waste disposal within INE's mission to provide the scientific basis for assessing long-term safety of a final nuclear waste repository. The INE-Beamline is accessible for the actinide and radiochemistry community through the ANKA proposal system and the European Union Integrated Infrastructure Initiative ACTINET-I3. Experiments with activities up to 1 x 10{sup +6} times the European exemption limit are feasible within a safe but flexible containment concept. Measurements with monochromatic radiation are performed at photon energies varying between {approx}2.1 keV (P K-edge) and {approx}25 keV (Pd K-edge), including the lanthanide L-edges and the actinide M- and L3-edges up to Cf. The close proximity of the INE-Beamline to INE controlled area labs offers infrastructure unique in Europe for the spectroscopic and microscopic characterization of actinide samples. The modular beamline design enables sufficient flexibility to adapt sample environments and detection systems to many scientific questions. The well-established bulk techniques x-ray absorption fine structure (XAFS) spectroscopy in transmission and fluorescence mode have been augmented by advanced methods using a microfocused beam, including (confocal) XAFS/x-ray fluorescence detection and a combination of (micro-)XAFS and (micro-)x-ray diffraction. Additional instrumentation for high energy-resolution x-ray emission spectroscopy has been successfully developed and tested.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantitative Detection of Single Molecules in Fluorescence Microscopy Images

Fluorescence imaging and counting of single molecules adsorbed or bound to surfaces are being employed in a number of quantitative analysis applications. Reliable molecular counts with knowledge of counting uncertainties, both false-positive and false-negative probabilities, are critical to these applications. By counting stationary single molecules on a surface, spatial criteria may be applied to the image analysis to improve confidence in detection, which is especially critical when detecting single fluorescent labels. In this work, we describe a simple approach to incorporating spatial criteria for counting single molecules by using an intensity threshold to locate regions with multiple, adjacent intense pixels, where the size of these regions is guided by the point-spread function of the microscope. By requiring multiple, spatially correlated bright pixels, false-positive events resulting from random samples of background noise are minimized. The reliability of detection is established by quantitative knowledge of the distributions of background and signals. By measuring and modeling both the background and single-molecule intensity distributions, false-positive and false-negative detection probabilities are estimated for arbitrary threshold parameters by using combinatorial statistics. From this theory, detection parameters can be optimized to minimize false-positive and false-negative probabilities, which can be calculated explicitly. For detection of single rhodamine 6G molecules at a threshold set at 2.5 times the standard deviation above background, the false-negative probability was only 1.5%, determined from distributions of single-molecule intensities on well-populated surfaces, and the false-positive probability from background noise was 2.8 spots per 50 × 50 μm image. Furthermore, the false-positive events compare favorably with theoretical probabilities calculated using combinatorial statistical analysis and simulated false-positive events counted in images of random noise.

36 MATERIALS SCIENCE↗

Selective triplet exciton formation in a single molecule

The formation of excitons in organic molecules by charge injection is an essential process in organic light-emitting diodes (OLEDs). According to a simple model based on spin statistics, the injected charges form spin-singlet (S1) excitons and spin-triplet (T 1 ) excitons in a 1:3 ratio. After the first report of a highly efficient OLED based on phosphorescence, which is produced by the decay of T 1 excitons, more effective use of these excitons has been the primary strategy for increasing the energy efficiency of OLEDs. Another route to improving OLED energy efficiency is reduction of the operating voltage. Because T 1 excitons have lower energy than S 1 excitons (owing to the exchange interaction), use of the energy difference could—in principle—enable exclusive production of T 1 excitons at low OLED operating voltages. However, a way to achieve such selective and direct formation of these excitons has not yet been established. Here we report a single-molecule investigation of electroluminescence using a scanning tunnelling microscope and demonstrate a simple method of selective formation of T 1 excitons that utilizes a charged molecule. A 3,4,9,10-perylenetetracarboxylicdianhydride (PTCDA) molecule adsorbed on a three-monolayer NaCl film atop Ag(111) shows both phosphorescence and fluorescence signals at high applied voltage. In contrast, only phosphorescence occurs at low applied voltage, indicating selective formation of T 1 excitons without creating their S 1 counterparts. The bias voltage dependence of the phosphorescence, combined with differential conductance measurements, reveals that spin-selective electron removal from a negatively charged PTCDA molecule is the dominant formation mechanism of T 1 excitons in this system, which can be explained by considering the exchange interaction in the charged molecule. Our findings show that the electron transport process accompanying exciton formation can be controlled by manipulating an electron spin inside a molecule. We anticipate that designing a device taking into account the exchange interaction could realize an OLED with a lower operating voltage.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel red-emitting phosphor Ba3ZrNb4O15:Pr3+: The structure, characteristic photoluminescence property and thermal quenching behaviour investigation

Highlights: • Novel red emitting phosphors BZN:Pr{sup 3+} were successfully synthesized. • Phase purity, morphology and luminescent property of BZN:Pr{sup 3+} were studied. • Different concentration behavior and related mechanism were discussed. • Decay times and the fluorescence dynamics process were investigated. • Temperature sensitive thermal quenching behavior and mechanism was studied. - Abstract: Pr{sup 3+} activated niobate phosphors Ba{sub 3-x}ZrNb{sub 4}O{sub 15}:xPr{sup 3+} were firstly synthesized through high temperature solid-state method. The phase purity, crystal structure, morphology, luminescence property as well as thermal quenching behavior were carefully determined by using X-ray diffractometer, scanned electron microscope, photoluminescence and temperature dependent emission spectra, respectively. The luminescent property showed that Ba{sub 3-x}ZrNb{sub 4}O{sub 15}:xPr{sup 3+} (0.002 ≤ x ≤ 0.03) had dominate excitation around 451 nm and could exhibit red emissions peaking at 608, 618 and 651 nm, attributed to the {sup 1}D{sub 2}-{sup 3}H{sub 4}, {sup 3}P{sub 0}-{sup 3}H{sub 6} and P{sub 0}-{sup 3}F{sub 2} transitions of Pr{sup 3+} ions. The different concentration quenching behaviors were found while the related mechanism was investigated. The room temperature decay times and the related fluorescence dynamics process of Pr{sup 3+} ions in Ba{sub 3}ZrNb{sub 4}O{sub 15} were investigated. In addition, the optimal doping contents, CIE chromaticity coordinates as well as the color purity were determined. At last, the temperature sensitive emission quenching and decay behavior were discussed and the activation energy was calculated based on Arrhenius equation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modal focal adaptive optics for Bessel-focus two-photon fluorescence microscopy

Adaptive optics (AO) improves the spatial resolution of microscopy by correcting optical aberrations. While its application has been well established in microscopy modalities utilizing a circular pupil, its adaptation to systems with non-circular pupils, such as Bessel-focus two-photon fluorescence microscopy (2PFM) with an annular pupil, remains relatively uncharted. Herein, we present a modal focal AO (MFAO) method for Bessel-focus 2PFM. Measuring and correcting aberration using a spatial light modulator placed in conjugation with the focal plane of the microscope objective, MFAO employs Zernike annular polynomials — a first in AO implementation — to achieve performance on par with a previous zonal AO method, but with a notably simplified optical configuration. We validated the performance of MFAO in correcting artificial and sample-induced aberrations, as well as in in vivo imaging of zebrafish larvae and mouse brains. By expanding the application of modal AO to annular pupils as well as aberration measurement and correction to a wavefront modulator at the objective focal plane, MFAO represents a notable advancement in the implementation of AO in microscopy.

47 OTHER INSTRUMENTATION↗

A Fluorescence Recovery After Photobleaching (FRAP) Technique for the Measurement of Solute Transport Across Surfactant-Laden Interfaces

The technique of Fluorescence Recovery After Photobleaching (FRAP) has been applied to the measurement of interfacial transport in two-phase systems. FRAP exploits the loss of fluorescence exhibited by certain fluorophores when over-stimulated (photobleached), so that a two-phase system, originally at equilibrium, can be perturbed without disturbing the interface by strong light from an argon-ion laser and its recovery monitored by a microscope-mounted CCD camera as it relaxes to a new equilibrium. During this relaxation, the concentration profiles of the probe solute are measured on both sides of the interface as a function of time, yielding information about the transport characteristics of the system. To minimize the size of the meniscus between the two phases, a photolithography technique is used to selectively treat the glass walls of the cell in which the phases are contained. This allows concentration measurements to be made very close to the interface and increases the sensitivity of the FRAP technique.

Browne, Edward P.↗

Shear Stress Sensing with Elastic Microfence Structures

In this work, elastic microfences were generated for the purpose of measuring shear forces acting on a wind tunnel model. The microfences were fabricated in a two part process involving laser ablation patterning to generate a template in a polymer film followed by soft lithography with a two-part silicone. Incorporation of a fluorescent dye was demonstrated as a method to enhance contrast between the sensing elements and the substrate. Sensing elements consisted of multiple microfences prepared at different orientations to enable determination of both shear force and directionality. Microfence arrays were integrated into an optical microscope with sub-micrometer resolution. Initial experiments were conducted on a flat plate wind tunnel model. Both image stabilization algorithms and digital image correlation were utilized to determine the amount of fence deflection as a result of airflow. Initial free jet experiments indicated that the microfences could be readily displaced and this displacement was recorded through the microscope.

Cisotto, Alexxandra↗

Differential white cell count by centrifugal microfluidics.

We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

59 BASIC BIOLOGICAL SCIENCES↗

Nanoscale Imaging of Whole Cells Using a Liquid Enclosure and a Scanning Transmission Electron Microscope

Nanoscale imaging techniques are needed to investigate cellular function at the level of individual proteins and to study the interaction of nanomaterials with biological systems. We imaged whole fixed cells in liquid state with a scanning transmission electron microscope (STEM) using a micrometer-sized liquid enclosure with electron transparent windows providing a wet specimen environment. Wet-STEM images were obtained of fixed E. coli bacteria labeled with gold nanoparticles attached to surface membrane proteins. Mammalian cells (COS7) were incubated with gold-tagged epidermal growth factor and fixed. STEM imaging of these cells resulted in a resolution of 3 nm for the gold nanoparticles. The wetSTEM method has several advantages over conventional imaging techniques. Most important is the capability to image whole fixed cells in a wet environment with nanometer resolution, which can be used, e.g., to map individual protein distributions in/on whole cells. The sample preparation is compatible with that used for fluorescent microscopy on fixed cells for experiments involving nanoparticles. Thirdly, the system is rather simple and involves only minimal new equipment in an electron microscopy (EM) laboratory.

36 MATERIALS SCIENCE↗