Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Fundamental Noise-Limited Optical Phase Locking at Femtowatt Light Levels

We describe an optical phase lock loop (PLL) designed to recover an optical carrier at powers below one picowatt in a Deep Space optical transponder. Previous low power optical phase lock has been reported with powers down to about 1 pW. We report the demonstration and characterization of the optical phase locking at femtowatt levels. We achieved a phase slip rate below one cycle-slip/second at powers down to 60 femtowatts. This phase slip rate corresponds to a frequency stability of 1 10(exp -14) at 1 s, a value better than any frequency standard available today for measuring times equal to a typical two-way delay between Earth and Mars. The PLL shows very robust stability at these power levels. We developed simulation software to optimize parameters of the second order PLL loop in the presence of laser flicker frequency noise and white phase (photon) noise, and verified the software with a white phase noise model by Viterbi. We also demonstrated precise Doppler tracking at femtowatt levels.

Doppler ranging↗

Raman − Ramsey pulsed excitation of coherent population trapping resonances in a {sup 87}Rb cell with a buffer gas

We report the results of experimental investigation of the Raman – Ramsey method of pulsed excitation of coherent population trapping (CPT) resonances in a rubidium vapour cell filled with a mixture of Ar and Ne buffer gases. For the development of compact quantum microwave frequency standards, this method is an alternative to the pulsed optical pumping method recently implemented using the same rubidium cell. Both methods have advantages over the traditional double radio-optical resonance technique, the main of which is the substantial suppression of the light shift of the clock transition frequency, since the evolution of the coherence of atomic states forming the clock transition occurs in the absence of laser radiation in the cell. The narrow (110 – 240 Hz) Raman – Ramsey resonances are obtained using the scheme of pulsed excitation of CPT resonances on the D{sub 1} lines of the {sup 87}Rb atom with the same linear (lin||lin) polarisations of the bichromatic laser radiation components. The process of optimising the central fringe linewidth, its contrast, and the linewidth-to-contrast ratio is described. The magnetic dependence of the Raman – Ramsey line central fringe linewidth is experimentally investigated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proceedings of the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting

This document is a compilation of technical papers presented at the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting held 1-3 December 1998 at the Hyatt Regency Hotel at Reston Town Center, Reston, Virginia. Papers are in the following categories: 1) Recent developments in rubidium, cesium, and hydrogen-based atomic frequency standards, and in trapped-ion and space clock technology; 2) National and international applications of PTTI technology with emphasis on GPS and GLONASS timing, atomic time scales, and telecommunications; 3) Applications of PTTI technology to evolving military navigation and communication systems; geodesy; aviation; and pulsars; and 4) Dissemination of precise time and frequency by means of GPS, geosynchronous communication satellites, computer networks, WAAS, and LORAN.

Breakiron, Lee A.↗

Magnetic Compensation for Second-Order Doppler Shift in LITS

The uncertainty in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced substantially by use of a very small magnetic inhomogeneity tailored to compensate for the residual second-order Doppler shift. An effect associated with the relativistic time dilatation, one cause of the second-order Doppler shift, is ion motion that is attributable to the trapping radio-frequency (RF)electromagnetic field used to trap ions. The second-order Doppler shift is reduced by using a multi-pole trap; however it is still the largest source of systematic frequency shift in the latest generation of LITSs, which are among the most stable clocks in the world. The present compensation scheme reduces the frequency instability of the affected LITS to about a tenth of its previous value. The basic principles of prior generation LITSs were discussed in several prior NASA Tech Briefs articles. Below are recapitulated only those items of basic information necessary to place the present development in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of the ground state hyperfine transition of 199Hg+ ions. The comparison involves a combination of optical and microwave excitation and interrogation of the ions in a linear ion trap in the presence of a nominally uniform magnetic field. In the current version of the LITS, there are two connected traps (see figure): (1) a quadrupole trap wherein the optical excitation and measurement take place and (2) a 12-pole trap (denoted the resonance trap), wherein the microwave interrogation takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. Shuttling ions into the resonance trap allows sensitive microwave interrogation to take place well away from loading interference. The axial magnetic field for the resonance trap is generated by an electric current in a finely wound wire coil surrounded by magnetic shields. In the quadrupole and 12-pole traps, the potentials are produced by RF voltages applied to even numbers (4 and 12, respectively) of parallel rods equally spaced around a circle. The polarity of the voltage on each rod is opposite that of the voltage on the adjacent rod. As a result, the amplitude of the RF trapping field is zero along the centerline and increases, with radius, to a maximum value near the rods.

Burt, Eric↗

Frequency comparisons via GPS carrier-phase: jump processing, temperature compensation and zero/short-baseline noise-floors

GPS carrier-phase receivers have been used to produce high quality time/frequency comparisons between clocks and frequency standards. Current ways of processing the carrier-phase data, however, result in phase jumps and data gaps that make the data difficult to use effectively and repeatedly for long datasets. In addition, temperature fluctuations generally perturb receiver output detrimentally. We describe the steps of a simple but effective automated algorithm for comparing frequencies that can compensate for data gaps, day boundary jumps, and other phase jumps as well as for temperature disturbances. We describe process features and focus on zero-baseline noise-floors, measuring Allan deviations of the Deep Space Atomic Clock mission’s receiver down to 1x10-17 at 5x105 seconds, with an upper confidence level of 3x10-17. The zero-baseline noise floors we present give confidence in our algorithm and temperature compensation’s robustness.

Diener, William A.↗

Precision Calculation of Blackbody Radiation Shifts for Optical Frequency Metrology

We show that three group IIIB divalent ions, B{sup +}, Al{sup +}, and In{sup +}, have anomalously small blackbody radiation (BBR) shifts of the ns{sup 2} {sup 1}S{sub 0}-nsnp {sup 3}P{sub 0}{sup o} clock transitions. The fractional BBR shifts for these ions are at least 10 times smaller than those of any other present or proposed optical frequency standards at the same temperature, and are less than 0.3% of the Sr clock shift. We have developed a hybrid configuration-interaction + coupled-cluster method that provides accurate treatment of correlation corrections in such ions and yields a rigorous upper bound on the uncertainty of the final results. We reduce the BBR contribution to the fractional frequency uncertainty of the Al{sup +} clock to 4x10{sup -19} at T=300 K. We also reduce the uncertainties due to this effect at room temperature to 10{sup -18} level for B{sup +} and In{sup +} to facilitate further development of these systems for metrology and quantum sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise in laser oscillator systems

The aim of the SUNLITE program is to demonstrate the performance of ultra-stable laser systems in the environment of space. The program uses Non-Planar Ring Oscillators (NPRO) which have shown great promise for time and frequency standards with unprecedented resolution and stability. An immediate goal is to test NPRO oscillators in orbital free fall by 1994. During the past year there was remarkable progress in the design and pre-flight testing of the SUNLITE test package. Current theoretical studies are investigating the possible effects of various noise sources on the linewidth and linecenter frequency stability of servocontrolled NPRO lasers. The frequency control system is reviewed and the potential impact on frequency stability of noise sources in the control system and in the environment is considered.

Hafele, Joseph C.↗

27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

This document is a compilation of technical papers presented at the 27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, held November 29 - December 1, 1995 at San Diego, CA. Papers are in the following categories: Recent developments in rubidium, cesium, and hydrogen-based frequency standards; and in cryogenic and trapped-ion technology; International and transnational applications of PTTI technology with emphasis on satellite laser tracking, GLONASS timing, intercomparison of national time scales and international telecommunications; Applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; Applications of PTTI technology to evolving military communications and navigation systems; and Dissemination of precise time and frequency by means of Global Positioning System (GPS), Global Satellite Navigation System (GLONASS), MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard L.↗

Performance evaluation of the SAO VLG-11 atomic hydrogen masers

A new generation of frequency standards, the VLG-11 hydrogen maser, has been designed and built at the Smithsonian Astrophysical Observatory (SAO). A comprehensive series of environmental and short-term stability tests on three VLG-11 masers has been completed and evaluated. The test results reported here show substantial improvements over previous hydrogen masers in measured sensitivity to variations in ambient temperature, barometric pressure, and magnetic fields. The maser frequency stability, as represented by the two-sample (Allan) variance, has been measured for averaging times ranging from 1 to 100,00 seconds. The variance is lower than 1 x 10 to the -15th for averaging intervals between 1400 and 20,000 seconds. For times shorter than 4000 seconds, the measured stability data agree remarkably well with theoretical values calculated from thermal noise mechanisms and the 'noise within the linewidth' regime is clearly discernable in the data.

Levine, M. W.↗

The 24th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

A compilation of technical papers presented at the 24th Precise Time and Time Interval (PTTI) Applications and Planning Meeting held in Dec. 1992 is presented. Papers are in the following categories: recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; international and transnational applications of PTTI technology with emphasis on satellite laser tracking networks, GLONASS timing, intercomparison of national time scales, and international telecommunications; applications of PTTI technology to the telecommunications, power distribution, and platform positioning, and geophysical survey industries; applications of PTTI technology to evolving military communications and navigation systems; and dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, Loran, and synchronous communications satellites.

Sydnor, Richard L.↗

Proceedings of the 23rd Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

A compilation of technical papers, from the 23rd annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, is presented. Papers were given in the following categories: (1) developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; (2) international and transnational applications of PTTI technology with emphasis on satellite laser tracking networks, GLONASS timing, comparison of national time scales and international communications; (3) applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; (4) applications of PTTI technology to evolving military communications and navigation systems; and (5) dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, Loran, and synchronous communications satellites.

Richard L. Sydnor↗

The 25th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

Papers in the following categories are presented: recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; international and transnational applications of precise time and time interval (PTTI) technology with emphasis on satellite laser tracking networks, GLONASS timing, intercomparison of national time scales and international telecommunication; applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; application of PTTI technology to evolving military communications and navigation systems; and dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard L.↗

A multichannel dual-mixer stability analyzer: progress report

A stability analyzer is being developed for frequency standards in JPL's Deep Space Network. Prototype hardware and software have been built. Initial tests on 100-MHz sources show an Allan deviation noise floor of about 7 X 10(sup -15) at 1 second for a dual-mixer channel.

frequency time stability dual mixer↗

The 26th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

This document is a compilation of technical papers presented at the 26th Annual PTTI Applications and Planning Meeting. Papers are in the following categories: (1) Recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; (2) International and transnational applications of Precise Time and Time Interval technology with emphasis on satellite laser tracking, GLONASS timing, intercomparison of national time scales and international telecommunications; (3) Applications of Precise Time and Time Interval technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; (4) Applications of PTTI technology to evolving military communications and navigation systems; and (5) Dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard↗

Repetitive Interrogation of 2-Level Quantum Systems

Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.

Rabi interrogation↗

Multi-Spacecraft Coherent Doppler and Ranging for Interplanetary Navigation

Future interplanetary mission concepts are increasingly focusing on multi-spacecraft missions and on small sample return missions which may involve the rendezvous between a spacecraft which brings a sample from the surface of a solar system body and a spacecraft which will return the sample to the Earth. These types of missions place tight requirements on the knowledge of the relative positions of the spacecraft. Historically spacecraft positions have been determined by the use of radio metric data (Doppler and range) between the spacecraft and terrestrial receiving stations. However, the various systems available place tight requirements on the stability of onboard frequency standards on each spacecraft and on the precision of the data extraction hardware on the spacecraft. An alternative is to extend the coherent ground to spacecraft link through one spacecraft to the other and then to the ground or back through the first spacecraft and to the ground receiver. Although this might appear initially to complicate the separation of the dynamics of the two spacecraft, this paper will show that in actual application, judicious selection of spacecraft transponder frequency ratios and the use of coherent Doppler and ranging and the derived observable, DRVID (Differenced Range vs. Integrated Doppler) can allow for the generation of observable equations which are dominated by the spacecraft to spacecraft link.

interplanetary↗

Diode laser 87Rb optical pumping in an evacuated wall-coated cell

The evacuated wall coated sealed cell coupled with diode laser optical pumping offers a number of attractive potential advantages for use in Rb or Cs atomic frequency standards. An investigation of systematic effects is required to explore possible limitations of the technique. The use of diode laser optical pumping of 87 Rb in an evacuated wall coated sealed cell is presented. Experimental results/discussion to be presented include the signal strength and line broadening of the 0 - 0 hyperfine resonance as a function of light intensity for the D1 optical transitions (F - F prime) - (2 1 prime) and (2 - 2 prime), shift of the 0 - 0 hyperfine frequency as a function of laser intensity and de-tuning from optical resonance, and diode laser frequency stabilization techniques.

Lee, W. K.↗

Extended Coherence Time on the Clock Transition of Optically Trapped Rubidium

Optically trapped ensembles are of crucial importance for frequency measurements and quantum memories but generally suffer from strong dephasing due to inhomogeneous density and light shifts. We demonstrate a drastic increase of the coherence time to 21 s on the magnetic field insensitive clock transition of {sup 87}Rb by applying the recently discovered spin self-rephasing [C. Deutsch et al., Phys. Rev. Lett. 105, 020401 (2010)]. This result confirms the general nature of this new mechanism and thus shows its applicability in atom clocks and quantum memories. A systematic investigation of all relevant frequency shifts and noise contributions yields a stability of 2.4x10{sup -11{tau}-1/2}, where {tau} is the integration time in seconds. Based on a set of technical improvements, the presented frequency standard is predicted to rival the stability of microwave fountain clocks in a potentially much more compact setup.