Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flexural testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Mechanical behavior of carbon-carbon composites

A general background, test plan, and some results of preliminary examinations of a carbon-carbon composite material are presented with emphasis on mechanical testing and inspection techniques. Experience with testing and evaluation was gained through tests of a low modulus carbon-carbon material, K-Karb C. The properties examined are the density - 1.55 g/cc; four point flexure strength in the warp - 137 MPa (19,800 psi) and the fill - 95.1 MPa (13,800 psi,) directions; and the warp interlaminar shear strength - 14.5 MPa (2100 psi). Radiographic evaluation revealed thickness variations and the thinner areas of the composite were scrapped. The ultrasonic C-scan showed attenuation variations, but these did not correspond to any of the physical and mechanical properties measured. Based on these initial tests and a survey of the literature, a plan has been devised to examine the effect of stress on the oxidation behavior, and the strength degradation of coated carbon-carbon composites. This plan will focus on static fatigue tests in the four point flexure mode in an elevated temperature, oxidizing environment.

Rozak, G. A.↗

Ames Research Center cryogenic mirror testing program - A comparison of the cryogenic performance of metal and glass mirrors with different types of mounts

A summary of the cryogenic testing of glass and metal mirrors performed at NASA Ames Research Center (ARC) and two other places is presented. Recent improvements to the ARC Cryogenic Optics Test Facility are described. The purposes of the tests were to determine: (1) how glass mirrors would perform at cryogenic temperatures compared with metal mirrors and (2) how various mirror mounts would affect the cryogenic performance of mirrors. Details of a cryogenic test of a 50 cm 'double arch', fused-silica mirror with a three-point mount and with a radially-compliant, flexured mount are given. Within the accuracy of the measurements, it was determined that the flexured mount did not induce appreciable distortion in the double arch mirror. Results of the cryogenic tests of a number of glass mirrors and two beryllium mirrors are included. The cryogenic distortion of the glass mirrors was found to be less than that for the beryllium mirrors. Within the accuracy of the measurements, no hysteresis was found in the glass mirrors. It was possible to measure hysteresis in one of the beryllium mirrors.

Miller, Jacob H.↗

New Apparatus Tests Pressure-Suit Joints

New apparatus measures applied torque and angle-of-flexure in pressurized flexible joints, such as those found in diving suits and flight suits. Torque and flexure are permanently recorded on x-y plotter. Family of curves can be taken as function of suit pressure or other variables. Apparatus could also measure torque-versus-angle in mechanical linkages.

Vykukal, H. C.↗

Toughening of PMR composites by semi-interpenetrating networks

Polymerization of monomer reactants (PMR-15) type polyimide and RP46 prepregs were drum wound using IM-7 fibers. Prepregging and processing conditions were optimized to yield good quality laminates with fiber volume fractions of 60 percent (+/- 2 percent). Samples were fabricated and tested to determine comprehensive engineering properties of both systems. These included 0 deg flexure, short beam shear, transverse flexure and tension, 0 deg tension and compression, intralaminar shear, short block compression, mode 1 and 2 fracture toughness, and compression after impact properties. Semi-2-IPN (interpenetrating polymer networks) toughened PMR-15 and RP46 laminates were also fabricated and tested for the same properties.

Tiwari, S. N.↗

Determination of the bending and buckling effect in the stress analysis of shell structures accessible from one side only

The present report describes a device for ascertaining the bending and buckling effect in stress measurements on shell structures accessible from one side only. Beginning with a discussion of the relationship between flexural strain and certain parameters, the respective errors of the test method for great or variable skin curvature within the test range are analyzed and illustrated by specimen example.

Dose, A↗

Mechanical Properties and Interfacial Bonding of Overmolded Polymer Composite Lattice Structures

This study investigates the mechanical properties and interfacial bonding of Polyamide 12 filled with Glass Fiber (PA12/GF) lattice structures overmolded with Nylon 66 (PA66) and Thermoplastic Polyurethane (TPU). The PA12/GF lattices, designed in Gyroid, Isotruss, and Octahedral geometries, were produced using the Selective Laser Sintering (SLS) technique. The thermal characteristics of both the lattice and overmolding materials were analyzed using Differential Scanning Calorimetry (DSC) and Thermogravimetric Analysis (TGA). The mechanical performance and interfacial bonding were evaluated through mechanical testing and microstructural analysis. The results indicate that overmolding improved flexural strength and impact resistance of the PA12/GF lattices. For instance, the plain PA12/GF Isotruss lattice exhibited a flexural strength of 15.5 MPa. By overmolding it with TPU the flexural strength increased by up to 137%, while PA66-overmolding resulted in an increase of 371%, achieving a flexural strength of 73 MPa. In terms of impact resistance, TPU-overmolding improved performance significantly, with an increase of 1800% (Gyroid) compared to the plain lattice. Microstructural analysis revealed good adhesion at the interface, especially when both the lattice and overmolding materials were thoroughly dried prior to the overmolding process to minimize interfacial porosity. This study highlights the potential of using overmolding to enhance lattice structures performance, offering lightweight and cost-efficient solutions for automotive applications.

Talabi, Isaac [ORNL] (ORCID:0000000340215594)↗

A mixed-mode bending apparatus for delamination testing

A mixed-mode delamination test procedure was developed combining double cantilever beam mode I loading and end notch flexure mode II loading on a split unidirectional laminate. By loading the specimen with a lever, a single applied load simultaneously produces mode I and II bending loads on the specimen. This mixed mode bending (MMB) test was analyzed using both finite element procedures and beam theory to calculate the mode I and II components of strain energy release rate, G sub I and G sub II, respectively. The analyses showed that a wide range of G sub I/G sub II ratios could be produced by varying the applied load position on the loading lever. As the delamination extended, the G sub I/G sub II ratios varied by less than 5 percent. The simple beam theory equations were modified to account for the elastic interaction between the two arms of the specimen and to account for shear deformations. The resulting equations agreed closely with the finite element results and provide a basis for selection of G sub I/G sub II test ratios and a basis for computing the mode I and II components of measured delamination toughness. The MMB specimen analysis and test procedures were demonstrated using unidirectional laminates.

Crews, John H., Jr.↗

Fatigue characterization of advanced carbon-carbon composites

Response of quasi-isotropic laminates of SiC coated Carbon-Carbon (C/C) composites under flexural fatigue are investigated at room temperature. Virgin as well as mission cycled specimens are tested to study the effects of thermal and pressure cycling on the fatigue performance of C/C. Tests were conducted in three point bending with a stress ratio of 0.2 and frequency of 1 Hz. Fatigue strength of C/C has been found to be considerably high - approximately above 85 percent of the ultimate flexural strength. The fatigue strength appears to be decreasing with the increase in the number of mission cycling of the specimens. This lower strength with the mission cycled specimens is attributed to the loss of interfacial bond strength due to thermal and pressure cycling of the material. C/C is also found to be highly sensitive to the applied stress level during cyclic loading, and this sensitivity is observed to increase with the mission cycling. Weibull characterization on the fatigue data has been performed, and the wide scatter in the Weibull distribution is discussed. Fractured as well as untested specimens were C-scanned, and the progressive damage growth during fatigue is presented.

Mahfuz, Hassan↗

Sub-ply level scaling approach investigated for graphite-epoxy composite beam columns

Scale model graphite-epoxy composite specimens were fabricated using the 'sub-ply level' approach and tested as beam-columns under an eccentric axial load to determine the effect of specimen size on flexural response and failure. In the current research project, although the fiber diameters are not scaled, the thickness of the pre-preg material itself has been scaled by adjusting the number of fibers through the thickness of a single ply. Three different grades of graphite-epoxy composite material (AS4/3502) were obtained from Hercules, Inc., in which the number of fibers through the thickness of a single ply was reduced (Grade 190 with 12 to 16 fibers, Grade 95 with 6 to 8 fibers, and Grade 48 with 3 to 4 fibers). Thus, using the sub-ply level approach, a baseline eight ply quasi-isotropic laminate could be fabricated using either the Grade 48 or Grade 95 material and the corresponding full-scale laminate would be constructed from Grade 95 or standard Grade 190 material, respectively. Note that in the sub-ply level approach, the number of ply interfaces is constant for the baseline and full-scale laminates. This is not true for the ply level and sublaminate level scaled specimens. The three grades of graphite-epoxy composite material were used to fabricate scale model beam-column specimens with in-plane dimensions of 0.5*n x 5.75*n, where n=1,2,4 corresponsing to 1/4, 1/2, and full-scale factors. Angle ply, cross ply, and quasi-isotropic laminate stacking sequences were chosen for the investigation and the test matrices for each laminate type are given. Specimens in each laminate family with the same in-plane dimensions but different thicknesses were tested to isolate the influence of the thickness dimension on the flexural response and failure. Also, specific lay-ups were chosen with blocked plies and dispersed plies for each laminate type. Specimens were subjected to an eccentric axial load until failure. The load offset was introduced through a set of hinges which were attached to the platens of a standard load test machine. Three sets of geometrically scaled hinges were used to ensure that scaled loading conditions were applied. This loading condition was chosen because it promotes large flexural deformations and specimens fail at the center of the beam, away from the grip supports. Five channels of data including applied vertical load, end shortening displacement, strain from gages applied back-to-back at the midspan of the beam, and rotation of the hinge from a bubble inclinometer were recorded for each specimen. The beam-column test configuration was used previously to study size effects in ply level scaled composite specimens of the same material system, sizes, and stacking sequences. Thus, a direct comparison between the two scaling approaches is possible. Ply level scaled beam-columns with angle ply, cross ply, and quasi-isotropic lay-ups exhibited no size dependencies in the flexural response, but significant size effects in strength. The reduction in strength with increasing specimen size was not predicted successfully by analysis techniques. It is anticipated that results from this investigation will lead to a better understanding of the strength scale effect in composite structures.

Jackson, Karen E.↗

Inverse Force Determination on a Small Scale Launch Vehicle Model Using a Dynamic Balance

A launch vehicle can experience large unsteady aerodynamic forces in the transonic regime that, while usually only lasting for tens of seconds during launch, could be devastating if structural components and electronic hardware are not designed to account for them. These aerodynamic loads are difficult to experimentally measure and even harder to computationally estimate. The current method for estimating buffet loads is through the use of a few hundred unsteady pressure transducers and wind tunnel test. Even with a large number of point measurements, the computed integrated load is not an accurate enough representation of the total load caused by buffeting. This paper discusses an attempt at using a dynamic balance to experimentally determine buffet loads on a generic scale hammer head launch vehicle model tested at NASA Ames Research Center's 11' x 11' transonic wind tunnel. To use a dynamic balance, the structural characteristics of the model needed to be identified so that the natural modal response could be and removed from the aerodynamic forces. A finite element model was created on a simplified version of the model to evaluate the natural modes of the balance flexures, assist in model design, and to compare to experimental data. Several modal tests were conducted on the model in two different configurations to check for non-linearity, and to estimate the dynamic characteristics of the model. The experimental results were used in an inverse force determination technique with a psuedo inverse frequency response function. Due to the non linearity, the model not being axisymmetric, and inconsistent data between the two shake tests from different mounting configuration, it was difficult to create a frequency response matrix that satisfied all input and output conditions for wind tunnel configuration to accurately predict unsteady aerodynamic loads.

testing↗

Pressure suit joint analyzer

A measurement system for simultaneously measuring torque and angular flexure in a pressure suit joint is described. One end of a joint under test is held rigid. A torque transducer is pivotably supported on the other movable end of a joint. A potentiometer is attached to the transducer by an arm. The wiper shaft of the potentiometer is gripped by a reference arm that rotates the wiper shaft the same angle as the flexure of joint. A signal is generated by the potentiometer which is representative of the joint flexure. A compensation circuit converts the output of the transducer to a signal representative of joint torque.

Vykukal, H. C.↗

Manufacturing and characterization of continuous fiber-reinforced thermoplastic tape overmolded long fiber thermoplastic

Light-weight construction, design freedom, integration of functions, and compelling cost element are desired by Original Equipment Manufacturers (OEMs) and their suppliers. The emergence of overmolding of continuous-discontinuous reinforcement enables design freedom and ability to tailor stiffness, strength, and damage tolerance for structural applications. In this work, long fiber thermoplastics (LFT) are overmolded with continuous fiber-reinforced thermoplastic (CFRTP) tape are combined using extrusion compression molding process to evaluate the structural performance. The CFRTP tape overmolded LFT samples were characterized using nondestructive and destructive techniques to track fiber alignment, fiber distribution, manufacturing defects, interfacial bonding of the tape – LFT and effect of CFRTP tape on LFT. Mode 1 fracture toughness, G 1c for tape overmolded LFT was higher by 25–30% compared to literature reported G 1c . This response was attributed to excellent fiber distribution, good fiber wetting, and absence of voids at the interface. Three-point bend test indicated that CFRTP tape overmolded LFT composites were better able to resist damage under the bending load compared to constituent LFT composite. Flexural strength of the overmolded composite was higher by 119–142%, and modulus higher by 77–65% compared to constituent LFT composite. Simulated flexural results accurately represents the mechanical behavior of composites. Here, the penetration energy of tape overmolded LFT composites determined by LVI test was in the range of 27.66–30.15 J, which is significantly higher than constituent LFT composite, 7.76 J. CFRTP tape overmolded LFT composite exhibits progressive fiber fracture, matrix cracking, and interfacial debonding failure, whereas, constituent LFT composite showed catastrophic fiber fracture.

42 ENGINEERING↗

Beam and Torsion Tests of Aluminum-alloy 61S-T Tubing

Tests were made to determine the effect of length and the effect of ratios of diameter to wall thickness upon the flexural and torsional moduli of failure of 61S-T aluminum-alloy tubing. The moduli of failure in bending, as determined by tests in which the tubing was loaded on the neutral axis at the one-third points of the span, were found to bear an approximately linear relationship with diameter-thickness ratio and were practically independent of span within the limits investigated. Empirical equations are given describing the relations obtained. The moduli of failure in torsion were found to be dependent upon length as well as upon diameter-thickness ratios. Empirical equations are given for predicting strengths within the range of plastic buckling. Within the elastic range, available torsion theories were found to be satisfactory.

Moore, R L↗

An experimental study of the mechanism of failure of rocks under borehole jack loading

Laboratory and field tests with an experimental jack and an NX-borehole jack are reported. The following conclusions were made: Under borehole jack loading, a circular opening in a brittle solid fails by tensile fracturing when the bearing plate width is not too small. Two proposed contact stress distributions can explain the mechanism of tensile fracturing. The contact stress distribution factor is a material property which can be determined experimentally. The borehole tensile strength is larger than the rupture flexural strength. Knowing the magnitude and orientation of the in situ stress field, borehole jack test results can be used to determine the borehole tensile strength. Knowing the orientation of the in situ stress field and the flexural strength of the rock substance, the magnitude of the in situ stress components can be calculated. The detection of very small cracks is essential for the accurate determination of the failure loads which are used in the calculation of strengths and stress components.

Van, T. K.↗

Effect of High Energy Radiation on Mechanical Properties of Graphite Fiber Reinforced Composites

The flexural strength and average modulus of graphite fiber reinforced composites were tested before and after exposure to 0.5 Mev electron radiation and 1.33 Mev gamma radiation by using a three point bending test (ASTM D-790). The irradiation was conducted on vacuum treated samples. Graphite fiber/epoxy (T300/5208), graphite fiber/polyimide (C6000/PMR 15) and graphite fiber/polysulfone (C6000/P1700) composites after being irradiated with 0.5 Mev electron radiation in vacuum up to 5000 Mrad, show increases in stress and modulus of approximately 12% compared with the controls. Graphite fiber/epoxy (T300/5208 and AS/3501-6), after being irradiated with 1.33 Mev gamma radiation up to 360 Mrads, show increases in stress and modulus of approximately 6% at 167 Mrad compared with the controls. Results suggest that the graphite fiber composites studied should withstand the high energy radiation in a space environment for a considerable time, e.g., over 30 years.

Naranong, N.↗

Advanced resin systems for graphite epoxy composites

The value of resin/carbon fiber composites as lightweight structures for aircraft and other vehicle applications is dependent on many properties: environmental stability, strength, toughness, resistance to burning, smoke produced when burning, raw material costs, and complexity of processing. A number of woven carbon fiber and epoxy resin composites were made. The epoxy resin was commercially available tetraglycidylmethylene dianiline. In addition, composites were made using epoxy resin modified with amine and carboxyl terminated butadiene acrylonitrile copolymer. Strength and toughness in flexure as well as oxygen index flammability and NBS smoke chamber tests of the composites are reported.

Gilwee, W. J.↗

Evaluation and ranking of candidate ceramic wafer engine seal materials

Modern engineered ceramics offer high temperature capabilities not found in even the best superalloy metals. The high temperature properties of several selected ceramics including aluminum oxide, silicon carbide, and silicon nitride are reviewed as they apply to hypersonic engine seal design. A ranking procedure is employed to objectively differentiate among four different monolithic ceramic materials considered, including: a cold-pressed and sintered aluminum oxide; a sintered alpha-phase silicon carbide; a hot-isostatically pressed silicon nitride; and a cold-pressed and sintered silicon nitride. This procedure is used to narrow the wide range of potential ceramics considered to an acceptable number for future detailed and costly analyses and tests. The materials are numerically scored according to their high temperature flexural strength; high temperature thermal conductivity; resistance to crack growth; resistance to high heating rates; fracture toughness; Weibull modulus; and finally according to their resistance to leakage flow, where materials having coefficients of thermal expansion closely matching the engine panel material resist leakage flow best. The cold-pressed and sintered material (Kyocera SN-251) ranked the highest in the overall ranking especially when implemented in engine panels made of low expansion rate materials being considered for the engine, including Incoloy and titanium alloys.

Steinetz, Bruce M.↗

Update of a nickel-hydrogen cycle life model

The topics are presented in viewgraph form and include the following: a cell capacity diagram, life predictions; compilation of Ni-H2 life test data; Fritts' electrode strain; Lim's electrode bending; Davolio's flexural Young's modulus; behavior of sintered nickel electrode; visualization of modified model; and nickel hydrogen technology status.

Thaller, Lawrence H.↗