Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluorescent probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗

High-fidelity imaging of a band insulator in a three-dimensional optical lattice clock

Here, we report on the observation of a high-density, band insulating state in a three-dimensional optical lattice clock. Filled with a nuclear-spin-polarized degenerate Fermi gas of 87 Sr, the three-dimensional (3D) lattice has one atom per site in the ground motional state, thus guarding against frequency shifts due to contact interactions. At this high density where the average distance between atoms is comparable to the probe wavelength, conventional imaging techniques at saturation intensity suffer from large systematic errors. To spatially probe frequency shifts in the clock and measure thermodynamic properties of this system, accurate imaging techniques at high optical depths are required. Using a combination of highly saturated fluorescence and absorption imaging, we confirm the density distribution in our 3D optical lattice in agreement with a single spin band insulating state. Combining our clock platform with this high filling fraction opens the door to studying new classes of long-lived, many-body states arising from dipolar interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CW laser strategies for simultaneous, multi-parameter measurements in high-speed gas flows

Strategies utilizing continuous wave (CW) lasers are considered which are capable of simultaneously measuring the flow parameters of velocity, temperature, and pressure at sampling rates exceeding 3 kHz. Velocity is determined from the Doppler shift of the spectral profile, temperature is extracted from intensity ratios of multiple lines, and pressure is measured from either the collision of broadening or the magnitude of absorption. Distinctions between strategies concern the specifics of probe spacies (NO, OH, O2, and H2O) in terms of nominal probe wavelength, equipment, and detection scheme. CW lasers were applied to path-integrated absorption measurements of transient shock-tube flows and spatially resolved laser-induced fluorescence measurements of underexpanded jets.

Di Rosa, M. D.↗

Preparation and Fluorescence Anisotropy Study of a Ribonuclease-Lucifer Yellow Conjugate

We have prepared a chemical derivative of ribonuclease A (RNase) with lucifer yellow (LY). The rotational dynamics of the LY-RNase conjugate were characterized by steady state and time resolved fluorescence techniques. Steady state anisotropy measurements were performed at varying viscosities at 10C and 20C, and the rotational correlation time of both RNase and the covalently linked LY probe were determined by time resolved frequency domain measurements. Our data suggest that the fluorophore is rigidly bound at 10C.

Malone, C. C.↗

Measurement of engine-oil fuel dilution using laser induced florescence spectroscopy

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil, or fuel in oil (FiO). Fuel dilution of oil is believed to be one of the underlying mechanisms that promotes low speed pre-ignition (LSPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of transient measurements, the LIF technique resolves transient dilution on the minutes time scale, making it possible to study the relation between FiO and LSPI. The measurement is based on adding a dye (ca. 500 ppm) to the fuel and monitoring for its presence in the oil via LIF. The instrument contains a 532-nm laser diode, and a spectrometer to resolve the LIF spectra. A fiber-optic assembly links the instrument to the engine measurement location; the probe is in a Y-configuration with the six fibers around one on a common probe end that connects to the engine; the Y-assembly legs are connected to the instrument; the two legs are the six fibers for transporting the laser light, and the single fiber for the fluorescence. We have expanded on our previous work (Parks et al, SAE paper 2007-01-4108, 2007), by demonstrating the diagnostic technique with to measure transient oil dilution on a 2.0-liter GM ECOTEC LNF single cylinder SI engine. The proposed LIF diagnostic will be critical in studying oil-dilution correlation with LSPI events.

Neupane, Sneha↗

Unraveling Cu Chemical Signature in CdTe by Spectral Fluorescence Mapping

X-ray absorption spectroscopy (XAS) has been shown to be a powerful tool to unravel the chemical environment of a given atom within a matrix. When used in correlative X-ray microscopy approaches, XAS allows one to probe with nanoscale precision regions of particular interest in an absorber. Herein, we use X-ray absorption near edge structure (XANES) to evaluate the chemical environment of Cu atoms within a CdTe solar cell. The reconstruction of XANES spectra from XRF maps have unfolded 2D maps of Cu chemical structures. In this work, we found that most Cu atoms exist in Cu 2 Te and Cu 1.4 Te phase. Moreover, we found traces of CuTe, Cu 2 O, CuO, Cu 2 S, CuS, and metallic Cu phase. Investigating Cu chemical structures at different performing areas, we found no observable correlation between Cu chemical structures and electrical performance. This approach allows tracking of Cu chemical structures along with electrical performance and elemental distribution simultaneously, with high spatial resolution in a statistically practical way.

CdTe↗

A Solvatochromic Near Infrared Fluorophore Sensitive to the Full Amyloid Beta Aggregation Pathway

Alzheimer's disease has long been associated with the aggregation of amyloid beta peptides (Aβ42) into macroscale plaques, although specific neurodegenerative agents have not been definitively identified. Much evidence has pointed to the soluble nanoscale oligomers that form early in the Aβ42 aggregation pathway, but there is little understanding of these structures, their mechanisms of formation, or how they grow into plaques. Here, we show that a solvatochromic fluorophore with near-infrared (NIR) emission can track synthetic Aβ42 aggregation through environment-sensitive spectral shifts from the earliest time points through plaque formation. This azide-functionalized phosphine oxide azetidine rhodol (Phazr-N3) shows large polarity-dependent changes in fluorescence emission, with maxima shifting from 630 nm in toluene to 703 nm in aqueous buffer, and a maximum quantum yield of 62%. Upon induction of Aβ42 aggregation, we observe immediate solvatochromic changes in Phazr-N3 fluorescence, with multiple apparent phases over 12 h, and which culminate before the onset of any major fluorescence changes of conformation-specific aggregation fluorophore thioflavin T. Solution anisotropy measurements show a low micromolar affinity of Phazr-N3 for disordered, free Aβ42 in solution, and real-time measurements are consistent with rapid liquid-liquid phase separation and slow dehydration of the growing aggregate. Spectral imaging of synthetic plaques stained in the presence of live cells and lipid-binding protein albumin shows over 4000-fold Phazr-N3 fluorescence intensity above background under no-wash conditions, and over 100-fold intensity above coplated microglial cells or a large excess of albumin. This use of a solvatochromic probe with structure-independent binding to free Aβ42 offers real-time, minimally invasive insight into the full Aβ42 aggregation pathway.

Wang, Zeming↗

Elucidation of Free Radical and Optogalvanic Spectroscopy Associated with Microgravity Combustion via Conventional and Novel Laser Platforms

Combustion studies under both normal gravity and microgravity conditions depend a great deal on the availability and quality of the diagnostic systems used for such investigations. Microgravity phenomena are specially susceptible to even small perturbations and therefore non-intrusive diagnostic techniques are of paramount importance for successful understanding of reduced-gravity combustion phenomena. Several non-intrusive diagnostic techniques are available for probing and delineating normal as well as reduced gravity combustion processes, such as Rayleigh scattering, Raman scattering, Mie scattering, velocimetry, interferometric and Schlieren techniques, emission and laser-induced fluorescence (LIF) spectroscopy. Our approach is to use the LIF technique as a non-intrusive diagnostic tool for the study of combustion-associated free radicals and use the concomitant optogalvanic transitions to accomplish precise calibration of the laser wavelengths used for recording the excitation spectra of transient molecular species. In attempting to perform spectroscopic measurements on chemical intermediates, we have used conventional laser sources as well as new and novel platforms employing rare-earth doped solid-state lasers. Conventional (commercially available) sources of tunable UV laser radiation are extremely cumbersome and energy-consuming devices that are not very suitable for either in-space or in-flight (or microgravity drop tower) experiments. Traditional LIF sources of tunable UV laser radiation involve in addition to a pump laser (usually a Nd:YAG laser with an attached frequency-doubling stage), a tunable dye laser. In turn, the dye laser has to be provided with a dye circulation system and a subsequent stage for frequency-doubling of the dye laser radiation, together with a servo-tuning system (termed the 'Autotracker') to follow the wavelength changes and also an optical system (called the 'Frequency Separator') for separation of the emanating visible and UV beams. In contrast to this approach, we have devised an alternate arrangement for recording LIF excitation spectra of free radicals (following appropriate precursor fragmentation) that utilizes a tunable rare-earth doped solid state laser system with direct UV pumping. We have designed a compact and portable tunable UV laser system incorporating features necessary for both in-space and in-flight spectroscopy experiments. For the purpose of LIF excitation, we have developed an all-solid-state tunable UV laser that employs direct pumping of the solid-state UV-active medium employing UV harmonics from a Nd:YAG laser. An optical scheme with counterpropagating photolysis and excitation beams focused by suitable lenses into a reaction vacuum chamber was employed.

Misra, Prabhakar↗

Directing Energy Transfer in Halide Perovskite–Chromophore Hybrid Assemblies

Directing the flow of energy and the nature of the excited states that are produced in nanocrystal–chromophore hybrid assemblies is crucial for realizing their photocatalytic and optoelectronic applications. Using a combination of steady-state and time-resolved absorption and photoluminescence (PL) experiments, we have probed the excited-state interactions in the CsPbBr 3 –Rhodamine B (RhB) hybrid assembly. PL studies reveal quenching of the CsPbBr 3 emission with a concomitant enhancement of the fluorescence of RhB, indicating a singlet-energy-transfer mechanism. Transient absorption spectroscopy shows that this energy transfer occurs on the ~200 ps time scale. To understand whether the energy transfer occurs through a Förster or Dexter mechanism, we leveraged facile halide-exchange reactions to tune the optical properties of the donor CsPbBr 3 by alloying with chloride. This allowed us to tune the spectral overlap between the donor CsPb(Br 1–x Cl x ) 3 emission and acceptor RhB absorption. For CsPbBr 3 -RhB, the rate constant for energy transfer (k ET ) agrees well with Förster theory, whereas alloying with chloride to produce chloride-rich CsPb(Br 1–x Cl x ) 3 favors a Dexter mechanism. These results highlight the importance of optimizing both the donor and acceptor properties to design light-harvesting assemblies that employ energy transfer. Furthermore, the ease of tuning optical properties through halide exchange of the nanocrystal donor provides a unique platform for studying and tailoring excited-state interactions in perovskite–chromophore assemblies.

14 SOLAR ENERGY↗

Interface instabilities in hafnium hydride entrained iron metal matrix composites

The chemical interactions in Fe–HfH 2 metal matrix composites (MMCs) are studied across multiple length scales to elucidate the decomposition of the parent phases and corresponding reaction zone physics during direct current sintering. Fe–HfH 2 composites were synthesized with increasing as-mixed hydride contents of Fe–25% HfH 2 , Fe–40% HfH 2 , Fe–55% HfH 2 , and Fe–70% HfH 2 (all in vol. %) to demonstrate the ability to achieve sintered MMCs with target hydride contents. Samples were probed across multiple length scales through a multi-modal workflow employing x-ray diffraction, scanning electron microscopy and segmentation analysis, and synchrotron techniques including hard x-ray fluorescence mapping and nanoprobe x-ray absorption near-edge structure measurements. Under the selected sintering temperature and pressure conditions, hydrogen evolution is seen to evolve through parallel paths: thermal decomposition from during the transformation of HfH 2 to HfH x<2 and through subsequent reaction with the Fe matrix leading to intermetallic phase formation. Specifically, HfFe and HfFe 2 intermetallic formation accelerates the release of hydrogen with a subsequent HfO 2 phase forming at grain boundaries. For this MMC, the consumption or loss of hydrogen can be considerable in compacts with initial hydride loading of 25%–40% HfH 2 approaching 83% hydrogen loss for the lower volume fraction composites. Increasing the volume fraction of HfH 2 to 70% enhanced the retained hydrogen content to 53% and attributed to the reduced interfacial area intrinsic to the increased HfH 2 loading in this MMC.

36 MATERIALS SCIENCE↗

Laminarin stimulates single cell rates of sulfate reduction whereas oxygen inhibits transcriptomic activity in coastal marine sediment

Abstract The chemical cycles carried out by bacteria and archaea living in coastal sediments are vital aspects of benthic ecology. These ecosystems are subject to physical disruption, which may allow for increased respiration and complex carbon consumption—impacting chemical cycling in this environment often thought to be a terminal place of deposition. We use the redox-enzyme sensitive probe RedoxSensor Green to measure rates of electron transfer physiology in individual sulfate reducer cells residing in anoxic sediment, subjected to transient exposure of oxygen and laminarin. We use index fluorescence activated cell sorting and single cell genomics sequencing to link those measurements to genomes of respiring cells. We measure per-cell sulfate reduction rates in marine sediments (0.01–4.7 fmol SO42− cell−1 h−1) and determine that cells within the Chloroflexota phylum are the most active in respiration. Chloroflexota respiration activity is also stimulated with the addition of laminarin, even in marine sediments already rich in organic matter. Evaluating metatranscriptomic data alongside this respiration-based technique, Chloroflexota genomes encode laminarinases indicating a likely ability to degrade laminarin. We also provide evidence that abundant Patescibacteria cells do not use electron transport pathways for energy, and instead likely carry out fermentation of polysaccharides. There is a decoupling of respiration-related activity rates from transcription, as respiration rates increase while transcription decreases with oxygen exposure. Overall, we reveal an active community of respiring Chloroflexota that cycles sulfate at potential rates of 23–40 nmol h−1 per cm3 sediment in incubation settings, and non-respiratory Patescibacteria that can cycle complex polysaccharides.

Lindsay, Melody R.↗

Propidium Monoazide (PMAxx)-Recombinase Polymerase Amplification Exo (RPA Exo) Assay for Rapid Detection of Burkholderia cepacia Complex in Chlorhexidine Gluconate (CHX) and Benzalkonium Chloride (BZK) Solutions

Both sterile and non-sterile pharmaceutical products, which include antiseptics, have been recalled due to Burkholderia cepacia complex (BCC) contamination. Therefore, minimizing the frequency of outbreaks may be conducive to the development of a quick and sensitive approach that can distinguish between live and dead loads of BCC. We have assessed an exo probe-based recombinase polymerase amplification (RPA) with 10 µM propidium monoazide (PMAxx) for selective detection of live/dead BCC cells in various concentrations of antiseptics (i.e., chlorhexidine gluconate (CHX) and benzalkonium chloride (BZK) solutions) after 24 h. The optimized assay conducted using a set of primer–probes targeting gbpT was performed at 40 °C for 20 min and shows a detection limit of 10 pg/µL of genomic DNA from B. cenocepacia J2315, equivalent to 10 4 colony-forming units (CFU/mL). The specificity of a newly designed primer and probe was 80% (20 negatives out of 25). The readings for total cells (i.e., without PMAxx) from 200 µg/mL CHX using PMAxx-RPA exo assay was 310 relative fluorescence units (RFU), compared to 129 RFU with PMAxx (i.e., live cells). Furthermore, in 50–500 µg/mL BZK-treated cells, a difference in the detection rate was observed between the PMAxx-RPA exo assay in live cells (130.4–459.3 RFU) and total cells (207.82–684.5 RFU). This study shows that the PMAxx-RPA exo assay appears to be a valid tool for the simple, rapid and presumptive detection of live BCC cells in antiseptics, thereby ensuring the quality and safety of pharmaceutical products.

59 BASIC BIOLOGICAL SCIENCES↗

Measurements of density, temperature, and their fluctuations in turbulent supersonic flow using UV laser spectroscopy

Nonintrusive measurements of density, temperature, and their turbulent fluctuation levels were obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment are compared with previous measurements obtained in the same facility using conventional probes and an earlier spectroscopic technique. Densities and temperatures measured with the current technique agree with the previous surveys to within 3 percent and 2 percent, respectively. The fluctuation amplitudes for both variables agree with the measurements obtained using the earlier spectroscopic technique and show evidence of an unsteady, weak shock wave that perturbs the boundary layer.

Fletcher, Douglas G.↗

Single-pulse measurement of density and temperature in a turbulent, supersonic flow using UV laser spectroscopy

Nonintrusive measurements of density and temperature and their turbulent fluctuation levels have been obtained in the boundary layer of an unseeded, Mach 2 wind tunnel flow. The spectroscopic technique that was used to make the measurements is based on the combination of laser-induced oxygen fluorescence and Raman scattering by oxygen and nitrogen from the same laser pulse. Results from this demonstration experiment compare favorably with previous measurements obtained in the same facility from conventional probes and an earlier spectroscopic technique.

Fletcher, D. G.↗

Medicine Delivery Device with Integrated Sterilization and Detection

Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. The application of semiconductor processing techniques and technologies to the problems of fluid manipulation and delivery has enabled the integration of chemical, electrical, and mechanical manipulation of samples all within a single microfluidic device. This approach has been successfully applied at JPL to the automated processing, detection, and analysis of minute quantities (parts per trillion level) of biomaterials to develop instruments for in situ exploration or extraterrestrial bodies. The same nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely high-surface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL's ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization or identification of the medicine itself. This constrained volume that is located immediately prior to delivery into a patient, ensures that the medicine delivery device is inherently sterile. An additional benefit to integrating a high-surface-area template within the fluid channel of a medicine delivery device is that one can envision a number of different functional coatings that could facilitate the capture and analysis of either microbial contaminants or the medicine itself. For example, one could attach antibodies or some other binding agent with a specific affinity to the silicon nanotip template. Once a target molecule or microbe is bound to the high-surface- area template, one could use an optical analytical technique such as fluorescence or adsorption to determine the identity and potentially the concentration of the species of interest. By illuminating the bound species from the back, it may also be possible to probe only the molecules with an evanescent wave, making detection of the species from the front side of the device much simpler.

Shearn, Michael J.↗

Three Component Velocity and Acceleration Measurement Using FLEET

The femtosecond laser electronic excitation and tagging (FLEET) method has been used to measure three components of velocity and acceleration for the first time. A jet of pure N2 issuing into atmospheric pressure air was probed by the FLEET system. The femtosecond laser was focused down to a point to create a small measurement volume in the flow. The long-lived lifetime of this fluorescence was used to measure the location of the tagged particles at different times. Simultaneous images of the flow were taken from two orthogonal views using a mirror assembly and a single intensified CCD camera, allowing two components of velocity to be measured in each view. These different velocity components were combined to determine three orthogonal velocity components. The differences between subsequent velocity components could be used to measure the acceleration. Velocity accuracy and precision were roughly estimated to be +/-4 m/s and +/-10 m/s respectively. These errors were small compared to the approx. 100 m/s velocity of the subsonic jet studied.

Danehy, Paul M.↗

Heterogeneous Outgassing Regions Identified on Active Centaur 29P/Schwassmann–Wachmann 1

Centaurs are transitional objects between primitive trans-Neptunian objects and Jupiter-family comets. Their compositions and activities provide fundamental clues regarding the processes affecting the evolution of and interplay between these small bodies. Here we report observations of centaur 29P/Schwassmann–Wachmann 1 (29P) with the James Webb Space Telescope (JWST). We identified localized jets with heterogeneous compositions driving the outgassing activity. We employed the NIRSpec mapping spectrometer to study the fluorescence emissions of CO and obtain a definitive detection of CO 2 for this target. The exquisite sensitivity of the instrument also enabled carbon and oxygen isotopic signatures to be probed. Molecular maps reveal complex outgassing distributions, such as jets and anisotropic morphology, which indicate that 29P’s nucleus is dominated by active regions with heterogeneous compositions. These distributions could reflect that it has a bilobate structure with compositionally distinct components or that strong differential erosion takes place on the nucleus. As there are no missions currently planning to visit a centaur, these observations demonstrate JWST’s unique capabilities in characterizing these objects.

Sara Faggi↗

SO2 Spectroscopy with A Tunable UV Laser

A portion of the fluorescence spectrum of SO2 has been studied using a narrow wavelength doubled dye laser as the exciting source. One purpose of this study is to evaluate the use of SO2 resonance re-emission as a probe of SO2 in the atmosphere. When the SO2 is excited by light at 300.2 nm, for example, a strong reemission peak is observed which is Stokes-shifted from the incident light wavelength by the usual Raman shift (the VI symmetric vibration frequency 1150.5/cm ). The intensity of this peak is sensitive to small changes (.01 nm) in the incident wavelength. Measurements of the N2 quenching and self quenching of this re-emission have been obtained. Preliminary analysis of this data indicates that the quenching is weak but not negligible. The dye laser in our system is pumped by a pulsed N2 laser. Tuning 'and spectral narrowing are accomplished using a telescope-echelle grating combination. In a high power configuration the resulting pulses have a spectral width of about 5 x 10(exp -3) nm and a time duration of about 6 nsec. The echelle grating is rotated by a digital stepping motor, such that each step shifts the wavelength by 6 x 10(exp -4) nm. In addition to the tunable, narrow wavelength uv source and spectral analysis of the consequent re-emission, the system also provides time resolution of the re-emitted light to 6 nsec resolution. This capability is being used to study the lifetime of low pressure S02 fluorescence at different wavelengths and pressures.

Morey, W. W.↗