Search NASA⌕ Search

SEARCH · Search NASA

Results for “Functional polymers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Phase-Shifting Liquid Crystal Interferometers for Microgravity Fluid Physics

The initial focus of this project was to eliminate both of these problems in the Liquid Crystal Point-Diffraction Interferometer (LCPDI). Progress toward that goal will be described, along with the demonstration of a phase shifting Liquid Crystal Shearing Interferometer (LCSI) that was developed as part of this work. The latest LCPDI, other than a lens to focus the light from a test section onto a diffracting microsphere within the interferometer and a collimated laser for illumination, the pink region contained within the glass plates on the rod-mounted platform is the complete interferometer. The total width is approximately 1.5 inches with 0.25 inches on each side for bonding the electrical leads. It is 1 inch high and there are only four diffracting microspheres within the interferometer. As a result, it is very easy to align, achieving the first goal. The liquid crystal electro-optical response time is a function of layer thickness, with thinner devices switching faster due to a reduction in long-range viscoelastic forces between the LC molecules. The LCPDI has a liquid crystal layer thickness of 10 microns, which is controlled by plastic or glass microspheres embedded in epoxy 'pads' at the corners of the device. The diffracting spheres are composed of polystyrene/divinyl benzene polymer with an initial diameter of 15 microns. The spheres deform slightly when the interferometer is assembled to conform to the spacing produced by the microsphere-filled epoxy spacer pads. While the speed of this interferometer has not yet been tested, previous LCPDIs fabricated at the Laboratory for Laser Energetics switched at a rate of approximately 3.3 Hz, a factor of 10 slower than desired. We anticipate better performance when the speed of these interferometers is tested since they are approximately three times thinner. Phase shifting in these devices is a function of the AC voltage level applied to the liquid crystal. As the voltage increases, the dye in the liquid crystal tends to become more transparent, thus introducing a rather large amount of error into the phase-shifting measurement. While that error can be greatly reduced by normalization, we prefer eliminating the source of the error. To that end, we have pursued development of a 'blend' of custom dyes that will not exhibit these properties. That goal has not yet been fully achieved. Guardalben, et al, presented a similar set of interferograms in a paper partially funded by this grant. Shearing interferometers are a second class of common path interferometers. Typically they consist of a thick glass plate optimized for equal reflection from the front and back surface. While not part of the original thrust of the project, through the course of laboratory work, we demonstrated a prototype of a shearing interferometer capable of phase shifting using a commercial liquid crystal retardation plate. A schematic of this liquid crystal shearing interferometer (LCSI) and a sample set of interferograms are in the reference. This work was also supported by the U.S. Department of Energy Office of Inertial Confinement Fusion under Cooperative Agreement No. DE-FC03-92SF19460, the University of Rochester, and the New York State Energy Research and Development Authority. The support of DOE does not constitute an endorsement by DOE of the views expressed in this article. Additional information is included in the original extended abstract.

Griffin, DeVon W.↗

On the linearity of fast atomic oxygen effects

The effect of bombardment of 8 km per second atomic oxygen (AO) experienced by exposed surfaces of satellites in low Earth orbit must be considered in the selection of materials to be used in instruments and functional systems on these satellites. The degree of importance of the effects varies widely depending on the material, the application, and the exposure (fluence of atoms) to which it is to be subjected. Some highly erodible thin polymer film materials might be considered unacceptable on a long-lived space station, but may be perfectly serviceable on a normal shuttle flight. In order to determine the acceptability of a material for a particular environment, a designer must know the relationship between the magnitude of the effect (for example, mass-loss) and the magnitude of the fluence. To determine this relationship, we need data over a useful range of fluence. Until the return of the Long Duration Exposure Facility (LDEF), the bulk of the data on materials effects was obtained from a few shuttle flights, and the bulk of that data from the flight of experiment Evaluation of Oxygen Interaction with Materials (EOIM-2) on STS-8 in 1983. EOIM-2 obtained a fluence of 3.5 x 10(exp 20) atoms cm(exp -2), while the LDEF fluence approached 10(exp 22) atoms cm(exp -2), or about 30 times greater. Although other flight exposures had been obtained with lower fluences, considerable uncertainty was attached to these results because of the possibility of large relative systematic errors and of other factors such as sweeping angle of attack. In the future, it is hoped that simulation facilities in the laboratory will allow testing of materials without the necessity of flying them in space. In addition, if the relationship of effect with oxygen fluence is well determined, it should not be necessary to expose a material for an entire mission fluence. In this paper, we shall avoid a comparison of flight data with results from simulators, though that comparison is important for the materials community. The present discussion is limited to flight data only.

Gregory, J. C.↗

A Nonlinear Viscoelastic-Viscoplastic Constitutive Model for Epoxy Polymers

The objective of this paper is to develop a nonlinear viscoelastic–viscoplastic constitutive model for epoxy polymers. The classic nonlinear viscoelasticity model is reformulated to yield a closed-form incremental constitutive relation, which relates the stress increments to the viscoelastic strain increments. A viscoplasticity model, which consists of the Drucker–Prager yield function, nonlinear isotropic and kinematic hardening laws, and the Perzyna viscosity function, is subsequently developed. The nonlinear viscoelasticity and the vis-coplasticity models are then implemented in a radial return algorithm. A closed-form algorithmic tangent operator is derived to facilitate model implementation. The nonlinear viscoelasticity model is validated by reproducing the test data for polymethyl methacrylate(PMMA). The present constitutive model’s capabilities are demonstrated through modeling viscoelastic–viscoplastic PMMA loaded at different strain rates. The mechanics of structure genome-based micromechanics approach, embedded with the present constitutive model, is used to homogenize a unidirectional fiber-reinforced composite with a PMMA matrix, subjected to uniaxial and shear loading at different strain rates. The viscoelastic characterization of PMT-F7 epoxy is evaluated by comparing the predicted creep–recovery responses by the present constitutive model with the experimental ones.

Liang Zhang↗

Machine-Learned Committor Functions for Reactive Molecular Dynamics

Reactive molecular dynamics (MD) is a powerful tool for atomistic-scale modeling of a diverse range of chemical processes. However, scaling these simulations to large systems and long times scales remains a challenge because of the complexity of the potential energy function required. The authors previously developed a heuristic approach, called REACTER, that incorporates reactivity in MD simulations in a less general but much more computationally efficient manner. REACTER uses standard, fixed valence force fields as the underlying potentialenergy surface for describing all interatomic interactions but adds a procedure for enforcing user-defined reactions that occur when certain geometric constraints on relative atomic positions are satisfied. Further, these bonding changes can be accepted or rejected with a probability related tothe local thermal energy. This work seeks to generalize this approach by replacing the set of user defined geometric constraints and energetic criteria with a committor function that specifies the probability of a reaction occurring on the basis of the local atomic configuration. The committor function is a useful mathematical tool for modeling rare events but, unfortunately, is very difficult to compute for realistic systems in a general way. This work describes a method for approximating the committor function using a machine learning approach, specifically a deep neural network trained with data from reactive MD and DFT-based dynamics simulations. This network is coupled to the existing REACTER protocol, as implemented in the LAMMPS MD package, and used to make on-the-fly predictions of reaction probabilities without the more extensive user input previously required. The new method is demonstrated using the polymerization of polystyrene as a case study. Although very dependent on the quality and quantity of training data, machine-learned committor functions show promise as a method for incorporating reaction probability from higher level calculations into highly scalable MD simulations.

polymer simulations↗

In-situ polymerized PLOT columns III: divinylbenzene copolymers and dimethacrylate homopolymers

Studies of divinylbenzene copolymers and dimethacrylate homopolymers indicate that the polymer pore size controls the separation of water and ammonia on porous-layer-open-tubular (PLOT) columns. To a lesser degree, the polarity of the polymers also affects the separation of a water-ammonia gas mixture. Our results demonstrate that the pore size can be regulated by controlling the cross-linking density or the chain length between the cross-linking functional groups. An optimum pore size will provide the best separation of water and ammonia.

NASA Discipline Exobiology↗

High Energy, Low Temperature Gelled Bi-propellant Formulation Preparation Method

A method for preparing a gelled liquid propane (GLP) composition comprises the introduction of liquid propane into an evacuated mixing vessel containing a gellant and mixing the liquid propane with the gellant. A bi-propellant system comprising GLP is particularly well-suited for outer planet missions greater than 3 AU from the sun and also functions in earth and near earth environments. Additives such as powders of boron, carbon, lithium, and/or aluminum can be added improve performance or enhance hypergolicity. The gelling agent can be silicon dioxide, clay, carbon, or organic or inorganic polymers. The bi-propellant system may be, but need not be, hypergolic.

DiSalvo, Roberto↗

Effect of Molecular Flexibility upon Ice Adhesion Shear Strength

Ice formation on aircraft surfaces effects aircraft performance by increasing weight and drag leading to loss of lift. Current active alleviation strategies involve pneumatic boots, heated surfaces, and usage of glycol based de-icing fluids. Mitigation or reduction of in-flight icing by means of a passive approach may enable retention of aircraft capabilities, i.e., no reduction in lift, while reducing the aircraft weight and mechanical complexity. Under a NASA Aeronautics Research Institute Seedling activity, the effect of end group functionality and chain length upon ice adhesion shear strength (IASS) was evaluated with the results indicating that chemical functionality and chain length (i.e. molecular flexibility) affected IASS. Based on experimental and modeling results, diamine monomers incorporating molecular flexibility as either a side chain or in between diamine functionalities were prepared, incorporated into epoxy resins that were subsequently used to fabricate coatings on aluminum substrates, and tested in a simulated icing environment. The IASS was found to be lower when molecular flexibility was incorporated in the polymer chain as opposed to a side chain.

Smith, Joseph G.↗

Verification of Prognostic Algorithms to Predict Remaining Flying Time for Electric Unmanned Vehicles

This paper addresses the problem of building trust in the online prediction of a eUAV’s remaining available flying time powered by lithium-ion polymer batteries. A series of ground tests are described that make use of an electric unmanned aerial vehicle (eUAV) to verify the performance of remaining flying time predictions. The algorithm verification procedure described is implemented on a fully functional vehicle that is restrained to a platform for repeated run-to-functional-failure (charge depletion) experiments. The vehicle under test is commanded to follow a predefined propeller RPM profile in order to create battery demand profiles similar to those expected during flight. The eUAV is repeatedly operated until the charge stored in powertrain batteries falls below a specified limit threshold. The time at which the limit threshold on battery charge is crossed is then used to measure the accuracy of the remaining flying time prediction. In our earlier work battery aging was not included. In this work we take into account aging of the batteries where the parameters were updated to make predictions. Accuracy requirements are considered for an alarm that warns operators when remaining flying time is estimated to fall below the specified limit threshold.

Edward F. Hogge↗

Effects of multifunctional crosslinking agents on the thermomechanical properties of polyimide films

The potential of high temperature resistant polymers such as polyimides (PI) and polyphenylquinoxalines (PPQ) as matrix resins in fiber-reinforced composites has not been fully realized to date. One of the problems associated with these resins is that they exhibit creep, or thermoplastic yielding under load at temperatures approaching 316 C (600 F). The purpose of this investigation was to further reduce thermoplastic behavior of polyimide resins by substituting a controlled amount of the diamine monomer with crosslinking agents having a higher amine functionality. The knowledge gained from a study of the thermomechanical properties of the crosslinked resins would then be used in the fabrication of fiber-reinforced polyimide composites. This report describes the synthesis and characterization of three new polyfunctional amines. Polyimide films containing varying amounts of the cross-linking agents were prepared, and their properties compared with those of control samples prepared with difunctional amines. The effect of crosslink density on isothermal weight loss, polymer softening, and glass transition temperatures is discussed.

Delvigs, P.↗

Thermal/Mechanical Durability of Polymer-Matrix Composites in Cryogenic Environments

In order to increase the reliability of the next generation of space transportation systems, the mechanical behavior of polymeric-matrix composite (PMC) materials at cryogenic temperatures must be investigated. This paper presents experimental data on the residual mechanical properties of a carbon fiber polymeric composite, IM7/PETI-5 as a function of temperature and aging. Tension modulus and strength were measured at room temperature, -196 C, and -269 C on five different specimens ply lay-ups. Specimens were preconditioned with one set of coupons being isothermally aged for 576 hours at -184 C, in an unloaded state. Another set of corresponding coupons were mounted in constant strain fixtures such that a constant uniaxial strain was applied to the specimens for 576 hours at -184 C. A third set was mechanically cycled in tension at -184 C. The measured properties indicated that temperature, aging, and loading mode can all have significant influence on performance. Moreover, this influence is a strong function of laminate stacking sequence. Thermal-stress calculations based on lamination theory predicted that the transverse tensile ply stresses could be quite high for cryogenic test temperatures. Microscopic examination of the surface morphology showed evidence of degradation along the exposed edges of the material because of aging at cryogenic temperatures. ________________

Gates, Thomas S.↗

Longtime Durability of PMR-15 Matrix Polymer at 204, 260, 288, and 316 C

Isothermal weight loss studies at the Glenn (Lewis) Research Center were conducted at four temperatures (204, 260, 288, and 316 C) with specimens of varied geometric shapes to investigate the mechanisms involved in the thermal degradation of PMR-15. Both neat resin behavior and composite behaviors were studied. Two points of interest in these studies are the role(s) of oxygen in the mechanisms involved in the thermo-oxidative degradation of these composite materials and the dimensional changes that occur during their useable lifetime. Specimen dimensional changes and surface layer growth were measured and recorded. It was shown that physical and chemical changes take place as a function of time and location in PMR-15 neat resin and composites as aging takes place in air at elevated temperatures. These changes initiate at the outer surfaces of both materials and progress inward following the oxygen as it proceeds by diffusion into the central core of each material. Microstructural changes cause changes in density, material shrinkage (strains), glass transition temperature, dimension, dynamic shear modulus, and compression properties. These changes also occur slowly dividing the polymer material into two distinct parts: a visibly undamaged core section between two visibly damaged surface layers. The surface layer has a significant effect on compression properties of thinner specimens, but the visibly undamaged core material controls these properties for specimens having eight or more plies. It was demonstrated that there are three different mechanisms involved in the degradation of PMR-15 during aging at elevated temperatures. These are a weight gain, a small weight fraction bulk material weight loss, and a large mass fraction weight loss concentrated at the surface of the polymer or composite. At the higher temperatures (260 C and above), the surface loss predominates. Below 260 C, the surface loss and the bulk core loss become more equivalent. Between 175 and 260 C, the initial weight change is due to a weight gain mechanism with a visible lifetime that diminishes as the aging temperature increases.

Bowles, Kenneth J.↗

Long-distance recording of the humidity over the sea

A procedure is developed for long distance recording of humidity over the sea that uses humidity detectors of the sorption type, whose electrical properties depend on the relative humidity of the air. The moisture sensitive material of the hygristor is the organic polymer polyacrylonitryl, deposited on silver electrodes and thermally treated. In the measurements of the relative humidity from 60% to 95%, the resistance of the hygristor varies from several hundred kiloohms to a few kiloohms, and is an essentially nonlinear function of the humidity.

Buklanov, V. V.↗

Effect of reactor loading on atomic oxygen concentration as measured by NO chemiluminescence

It has previously been observed that the etch rate of polyethylene samples in the afterglow of an RF discharge in oxygen increases with reactor loading. This enhancement of the etch rate is attributed to reactive gas phase products of the polymer etching. In the present work, emission spectroscopy is employed to examine the species present in the gas phase during etching of polyethylene. In particular, the concentration of atomic oxygen downstream from the polyethylene samples is studied as a function of the reactor loading. It is found that the concentration of atomic oxygen increases as the reactor loading is increased. The increase of etch rate with increased reactor loading is attributed to the increase of atomic oxygen concentration in the vicinity of the sample.

Lerner, N. R.↗

The Charging of Composites in the Space Environment

Deep dielectric charging and subsequent electrostatic discharge in composite materials used on spacecraft have become greater concerns since composite materials are being used more extensively as main structural components. Deep dielectric charging occurs when high energy particles penetrate and deposit themselves in the insulating material of spacecraft components. These deposited particles induce an electric field in the material, which causes the particles to move and thus changes the electric field. The electric field continues to change until a steady state is reached between the incoming particles from the space environment and the particles moving away due to the electric field. An electrostatic discharge occurs when the electric field is greater than the dielectric strength of the composite material. The goal of the current investigation is to investigate deep dielectric charging in composite materials and ascertain what modifications have to be made to the composite properties to alleviate any breakdown issues. A 1-D model was created. The space environment, which is calculated using the Environmental Workbench software, the composite material properties, and the electric field and voltage boundary conditions are input into the model. The output from the model is the charge density, electric field, and voltage distributions as functions of the depth into the material and time. Analysis using the model show that there should be no deep dielectric charging problem with conductive composites such as carbon fiber/epoxy. With insulating materials such as glass fiber/epoxy, Kevlar, and polymers, there is also no concern of deep dielectric charging problems with average day-to-day particle fluxes. However, problems can arise during geomagnetic substorms and solar particle events where particle flux levels increase by several orders of magnitude, and thus increase the electric field in the material by several orders of magnitude. Therefore, the second part of this investigation was an experimental attempt to measure the continuum electrical properties of a carbon fiber/epoxy composite, and to create a composite with tailorable conductivity without affecting its mechanical properties. The measurement of the conductivity and dielectric strength of carbon fiber/epoxy composites showed that these properties are surface layer dominated and difficult to measure. In the second experimental task, the conductivity of a glass fiber/epoxy composite was increased by 3 orders of magnitude, dielectric constant was increased approximately by a factor of 16, with minimal change to the mechanical properties, by adding conductive carbon black to the epoxy.

Czepiela, Steven A.↗

A model for interphase chromosomes and evaluation of radiation-induced aberrations

We have developed a theoretical model for evaluating radiation-induced chromosomal exchanges by explicitly taking into account interphase (G(0)/G(1)) chromosome structure, nuclear organization of chromosomes, the production of double-strand breaks (DSBs), and the subsequent rejoinings in a faithful or unfaithful manner. Each of the 46 chromosomes for human lymphocytes (40 chromosomes for mouse lymphocytes) is modeled as a random polymer inside a spherical volume. The chromosome spheres are packed randomly inside a spherical nucleus with an allowed overlap controlled by a parameter Omega. The rejoining of DSBs is determined by a Monte Carlo procedure using a Gaussian proximity function with an interaction range parameter sigma. Values of Omega and sigma have been found which yield calculated results of interchromosomal aberration frequencies that agree with a wide range of experimental data. Our preferred solution is one with an interaction range of 0.5 microm coupled with a relatively small overlap parameter of 0.675 microm, which more or less confirms previous estimates. We have used our model with these parameter values and with resolution or detectability limits to calculate yields of translocations and dicentrics for human lymphocytes exposed to low-LET radiation that agree with experiments in the dose range 0.09 to 4 Gy. Five different experimental data sets have been compared with the theoretical results. Essentially all of the experimental data fall between theoretical curves corresponding to resolution limits of 1 Mbp and 20 Mbp, which may reflect the fact that different investigators use different limits for sensitivity or detectability. Translocation yields for mouse lymphocytes have also been calculated and are in good agreement with experimental data from 1 cGy to 10 cGy. There is also good agreement with recent data on complex aberrations. Our model is expected to be applicable to both low- and high-LET radiation, and we include a sample prediction of the yield of interchromosomal rejoining in the dose range 0.22 Gy to 2 Gy of 1000 MeV/nucleon iron particles. This dose range corresponds to average particle traversals per nucleus ranging from 1.0 to 9.12.

Non-NASA Center↗

A method for estimating both the solubility parameters and molar volumes of liquids

Development of an indirect method of estimating the solubility parameter of high molecular weight polymers. The proposed method of estimating the solubility parameter, like Small's method, is based on group additive constants, but is believed to be superior to Small's method for two reasons: (1) the contribution of a much larger number of functional groups have been evaluated, and (2) the method requires only a knowledge of structural formula of the compound.

Fedors, R. F.↗

Carbon Nanomaterials as Reinforcements for Composites

Carbon nanomaterials including fellerenes, nanotubes (CNT) and nanofibers have been proposed for many applications. One of applications is to use the carbon nanomaterials as reinforcements for composites, especially for polymer matrices. Carbon nanotubes is a good reinforcement for lightweight composite applications due to its low mass density and high Young's modulus. Two obscures need to overcome for carbon nanotubes as reinforcements in composites, which are large quantity production and functioning the nanotubes. This presentation will discuss the carbon nanotube growth by chemical vapor deposition. In order to reduce the cost of producing carbon nanotubes as well as preventing the sliding problems, carbon nanotubes were also synthesized on carbon fibers. The synthesis process and characterization results of nanotubes and nanotubes/fibers will be discussed in the presentation.

Zhu, Shen↗

Simulated Galactic Cosmic Ray and Solar Particle Event Radiation Effects on Inflatable Habitat, Composite Habitat, Space Suit and Space Hatch Cover Materials

The effect of particle radiation representative of galactic cosmic ray (GCR) and solar particle event (SPE) radiation on polymeric materials used in deep space mission environments is largely unknown. For NASA, this uncertainty represents an unquantified mission risk. To better quantify this risk, selected polymeric materials used in inflatable habitats, composite habitats, space suits and space hatch covers are irradiated at the Brookhaven National Laboratory, after which changes in relevant end-use properties are measured. The irradiated materials are lightweight candidates having critical functions such as ripstops, permeation barriers, micrometeoroids and orbital debris (MMOD) shield layers and restraint layers.The effect of several types of particle radiation are evaluated. To evaluate GCR effects, high-energy (1 GeV) protons and iron nucleons are used. To evaluate SPE effects, intermediate energy (ca. 20 to 40 MeV) protons are used. In addition, two mission scenarios are evaluated: a Mars mission cycle (space suit materials) and a worst-case 50 year deep space mission cycle (all materials). Lastly, a common polymer (high density polyethylene (HDPE)) is subjected to accelerated aging and radiation exposure to determine if a combined physical aging/radiation effect exists.The level of radiation induced property change observed in this study after exposure of polymers to kGy levels of intermediate and high energy ions is often significant and is quantitatively comparable to the level of change reported for similar materials exposed to MGy levels of low energy protons, electrons and gamma-radiation. This suggests that intermediate and high energy ions encountered in space may cause more damage than low energy forms of radiation due to displacement and linear energy transfer (LET) effects. For these reasons, it is recommended that final approval for mission use be made by the appropriate NASA material and structural review boards to ensure radiation induced changes in candidate materials do not interfere with their engineering function in the intended mission application. Since the materials tested in this report received doses exceeding actual mission doses, the results are considered conservative as a first approximation. However, caution must be exercised when evaluating radiation effects in the absence of other secondary factors know to contribute to degradation. In the addition to radiation type and energy, the results presented in this study show that molecular composition, orientation, stress and physical aging can also contribute to or influence degradation. Other factors such as polymer formulation, secondary radiation effects, stress, exposure to elevated temperature, thermal cycling and exposure to ozone were not investigated here, but must be considered when performing a comprehensive evaluation of a polymeric materials suitability for service in a space radiation environment. Only when the total sum of these factors operating in concert with radiation are accounted for, can accurate assessments of a material's suitability be made.

Jess M. Waller↗