Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

The effect of hyperthermia on the radiation response of crypt cells in mouse jejunum

The effect of hyperthermia and/or gamma-radiation on the survival of intestinal crypt cells was studied in BDF sub 1 mice using a microcolony assay. Hyperthermia treatments, which in themselves caused no detectable cell lethality, inhibited the capacity of crypt cells to repair sublethal radiation damage. In addition, heat applied either before or after single radiation exposures potentiated lethal damage to crypt cells; the degree of enhancement was dependent on the time interval between treatments. At the levels of heating employed, DNA synthesis in the intestinal epithelium was significantly reduced immediately following exposure, but returned rapidly to normal levels. No further disturbances in cellular kinetics were observed for up to 10 days after heating.

Wilson, J. D.↗

CADIS and FW-CADIS Variance Reduction in Gamma Transport for Predicting Prompt Forensics Signatures

The goal of prompt nuclear forensics is to determine the characteristics of a nuclear detonation based on the signatures available almost immediately after the explosion. An important characteristic is the reaction time history (RTH), a measure of the device’s rate of neutron multiplication. The RTH can be estimated by observation of the gamma radiation emitted from the detonation, which can be detected directly or observed indirectly as Teller light. Gamma transport simulations used to predict these radiation fields are often modeled stochastically using the Monte Carlo N-Particle (MCNP) code, which can be a computationally demanding task due to the number of particle histories needed to achieve statistical convergence. In an attempt to improve the efficiency of these calculations, we evaluate two variance reduction techniques: Consistent Adjoint-Driven Importance Sampling (CADIS) and Forward-Weighted Consistent Adjoint-Driven Importance Sampling (FW-CADIS). These methods use a deterministically calculated adjoint flux to create weight windows and source biasing that guide MCNP sampling. We study the utility of CADIS and FW-CADIS for their use in MCNP gamma transport for nuclear forensics prediction simulations. Furthermore, the results demonstrate that both CADIS and FW-CADIS improve the accuracy for forensics-focused simulations, with CADIS being most beneficial in direct detection and FW-CADIS being ideal for computing a global Teller light source.

CADIS↗

Indium Tin-Doped Oxide Interactions with Solvent Radiolysis Products

Transparent conductive oxides (TCOs), such as indium tin-doped oxide (ITO), are ubiquitous as components of electronics and are ideal electrode substrates for catalysis, energy transformation reactions, and energy storage applications. Recently, researchers have recognized their effectiveness as electrode materials for manipulating actinide oxidation states in solution. Despite their popularity as electrode materials, prior studies focused extensively on the direct radiolysis of TCO materials in air and rarely examined these effects within a solution, limiting our fundamental understanding of the interactions between solvent radiolysis products and these substrates in high radiation environments. Here, in this study, we characterize the effects of solvent radiolysis products—arising from the gamma irradiation of water, aqueous nitric acid solutions, and n-dodecane—on the composition, surface speciation, and band structure of ITO thin films on a glass substrate as a function of absorbed dose using UV-visible spectroscopy, scanning electron microscopy, photoelectrochemistry, and X-ray photoelectron spectroscopy. Our work demonstrates that mesoporous thin film electrodes of ITO exposed to gamma radiation in each solvent accumulate defects and exhibit solvent and dose dependent changes to their surface and interfacial properties. These electrodes maintain their electrochemical function and improve their photoelectrochemical performance up to at least 100 kGy of accumulated gamma dose, confirming their utility in solvents exposed to ionizing radiation fields.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hardening electronic devices against very high total dose radiation environments

The possibilities and limitations of hardening silicon semiconductor devices to the high neutron and gamma radiation levels and greater than 10 to the eighth power rads required for the NERVA nuclear engine development are discussed. A comparison is made of the high dose neutron and gamma hardening potential of bipolar, metal insulator semiconductors and junction field effect transistors. Experimental data is presented on device degradation for the high neutron and gamma doses. Previous data and comparisons indicate that the JFET is much more immune to the combined neutron displacement and gamma ionizing effects than other transistor types. Experimental evidence is also presented which indicates that p channel MOS devices may be able to meet the requirements.

Buchanan, B.↗

M-BAND Analysis of Chromosome Aberration Induced by Fe-Ions in Human Epithelial Cells Cultured in 3-Dimensional Matrices

Energetic heavy ions pose a great health risk to astronauts in extended ISS and future lunar and Mars missions. High-LET heavy ions are particularly effective in causing various biological effects, including cell inactivation, genetic mutations, cataracts and cancer induction. Most of these biological endpoints are closely related to chromosomal damage, which can be utilized as a biomarker for radiation insults. Previously, we had studied low- and high-LET radiation-induced chromosome aberrations in human epithelial cells cultured in 2-dimension (2D) using the multicolor banding fluorescence in situ hybridization (mBAND) technique. However, it has been realized that the biological response to radiation insult in a 2D cellular environment in vitro can differ significantly from the response in 3-dimension (3D) or at the actual tissue level. In this study, we cultured human epithelial cells in 3D to provide a more suitable model for human tissue. Human mammary epithelia cells (CH184B5F5/M10) were grown in Matrigel to form 3D structures, and exposed to Fe-ions at NASA Space Radiation Laboratory (NSRL) at the Brookhaven National Laboratory or 137Cs-gamma radiation source at the University of Texas MD Anderson Cancer Center. After exposure, cells were allowed to repair for 16hr before dissociation and subcultued at low density in 2D. G2 and metaphase chromosomes in the first cell cycle were collected using a chemical-induced premature chromosome condensation (PCC) technique, and chromosome aberrations were analyzed using mBAND technique. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of interchromosomal aberrations (translocation to unpainted chromosomes) and intrachromosomal aberrations (inversions and deletions within a single painted chromosome). Our data indicate a significant difference of the chromosome aberration yield between 2D and 3D cell cultures for gamma exposures, but not for Fe ion exposures. Therefore, the RBE for chromosome aberrations obtained in a 2D model may not represent accurately the RBE for tissues.

Hada, M.↗

High- and low-LET Radiation-induced Chromosome Aberrations in Human Epithelial Cells Cultured in 3-dimensional Matrices

Energetic heavy ions pose a great health risk to astronauts who participate in extended ISS missions and will be an even greater concern for future manned lunar and Mars missions. High-LET heavy ions are particularly effective in causing various biological effects, including cell inactivation, genetic mutations, cataracts and cancer induction. Most of these biological endpoints are closely related to chromosomal damage, which can be utilized as a biomarker for radiation insults. Previously, we had studied low- and high-LET radiation-induced chromosome aberrations in human epithelial cells cultured in 2-dimension (2D) using the multicolor banding fluorescence in situ hybridization (mBAND) technique. However, it has been realized that the biological response to radiation insult in a 2D in vitro cellular environment can differ significantly from the response in 3-dimension (3D) or at the actual tissue level. In this study, we cultured human epithelial cells in 3D to provide a more suitable model for human tissue. Human mammary epithelial cells (CH184B5F5/M10) were grown in Matrigel to form 3D structures, and exposed to Fe-ions at NASA Space Radiation Laboratory (NSRL) at the Brookhaven National Laboratory or 137Cs-gamma radiation source at the University of Texas MD Anderson Cancer Center. After exposure, cells were allowed to repair for 16hr before dissociation and subcultured at low density in 2D. G2 and metaphase chromosomes in the first cell cycle were collected in the first cell cycle after irradiation using a chemical-induced premature chromosome condensation (PCC) technique, and chromosome aberrations were analyzed using mBAND technique. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of interchromosomal aberrations (translocation to unpainted chromosomes) and intrachromosomal aberrations (inversions and deletions within a single painted chromosome). Our data indicate a significant difference in the chromosome aberration yield between 2D and 3D cell cultures after gamma exposures, but not after Fe ion exposures. Therefore, the Relative Biological Effect (RBE) for induction of chromosome aberrations obtained in a 2D model may not accurately represent RBE values obtained for tissue exposure.

Hada, M.↗

Performance Analysis and Radiation Damage Estimation of the Stopping Target Monitor Detectors in Mu2e

The Mu2e experiment aims to search for the charged lepton flavour violating (CLFV) process of a coherent, neutrinoless, conversion of a muon into an electron within the proximity of an aluminium nucleus. Mu2e seeks to measure the ratio (R μe ) of the rate of this conversion process, relative to that of ordinary muon capture. Mu2e will achieve world-leading sensitivity, improving the current limit of Rμe < 7 ×10 -13 (90% C.L.),set by the SINDRUM-II experiment, by an order of 104. This corresponds to a single-event sensitivity of Rμe < 2.87 × 10 -17 (90% C.L.). Many beyond Standard Model (BSM) theories require CLFV to occur at a rate accessible by Mu2e. Any observation of CLFV at Mu2e would have profound implications on particle physics. The Stopping Target Monitor (STM) will be comprised of both a HPGe and a LaBr3 detector which will monitor the signals of photons produced in stopped-muon processes to a required accuracy of 10%. To achieve the desired sensitivity, it is imperative that the detectors perform at their optimal level. The STM detectors are placed within a harsh radiation environment in the form of a high energy ‘flash’ of gamma radiation as well as a flux of fast neutrons. Estimations of radiation damage to HPGe in literature is limited. This thesis reports an approach which utilizes the Kinetic-Energy Released in Matter (KERMA) parameter that considers the energy dependence of the incident flux and the cross-section information for the incident particle. Resampling schemes have been adopted to give a realistic rate over the experiment run time. The results have then been normalized to the radiation damage caused by a 252 Cf source. The estimated time before annealing of the detector is necessary is found to be 75 and 78 months in the case of neutron damage and τ ~ 24 years, 11 months in the case of electron/positron induced damage. This shows significant improvement on the previous estimations.

36 MATERIALS SCIENCE↗

The GRAD high-altitude balloon flight over Antarctica

The Gamma Ray Advanced Detector (GRAD) consists of a n-type germanium detector inside an active bismuth-germanate Compton and charged particle shield with additional active plastic shielding across the aperture. It will be flown on a high-altitude balloon at 36 km altitude at a latitude of 78 deg S over Antarctica for observations of gamma radiation emitted by the radioactive decay of Co-56 in the supernova SN1987A, for assessment of the performance of bismuth-germanate scintillation material in the radiation environment of near space, for gathering information on the gamma-ray background over Antarctica, and for testing fault-tolerant software.

Eichhorn, G.↗

Neurovascular Responses to Simulated Deep Space Radiation in a Human Organ-on-a-Chip Model

A major health risk for human deep space exploration is central nervous system (CNS) damage by galactic cosmic ray radiation. Simulated galactic cosmic rays or their components, especially the high-linear energy transfer (LET) particles such as 56Fe ions, have been shown to cause CNS damage, neuroinflammation and cognitive dysfunction in rodent models, but their effects on human CNS remain to be investigated. CNS damage from any insult, including ionizing radiation, is partially mediated by the blood-brain barrier (BBB), which regulates interactions between CNS and the rest of the body. The main cellular regulators of BBB permeability are astrocytes, which also modulate neuroinflammation. However, there have been few studies on BBB and astrocyte functions in regulating CNS responses, especially in human tissue analogs. Therefore, we utilized a high-throughput 3D organ-on-a-chip system, seeded with human induced pluripotent stem cell-derived astrocytes and brain endothelial cells, or brain endothelial cells alone, to study human neurovascular responses to simulated deep space radiation. We investigated the permeability and morphology of vascular structures formed by endothelial cells, as well as oxidative stress and secreted cytokines and chemokine levels over 1-7 days after irradiation with 0.25 – 0.5 Gy 5-ion simplified simulated galactic cosmic rays or 0.3 – 0.8 Gy high-LET 600 MeV/n 56Fe particles, and compared the outcomes to low-LET X-ray irradiation. We observed that simulated deep space radiation caused delayed astrocyte activation in a pattern resembling CNS responses to brain injury, caused oxidative stress and the production of inflammatory cytokines, and compromised BBB integrity by damaging tight junctions, thus increasing vascular permeability. Furthermore, our results indicate that astrocytes have a dual role in regulating radiation responses: they exacerbate blood-brain barrier permeability early after irradiation, followed by switching to a more protective scar-like phenotype by reducing oxidative stress and pro-inflammatory cytokine and chemokine secretion. In a follow-up study using the same platform, we investigated the dose-rate effects of ionizing radiation, by exposing our model to chronic, low dose-rate, gamma radiation. Our model was significantly improved by adding additional cell types composing the BBB, modelling immune cell infiltration into the brain, and studying the effect of an antioxidant, to measure more complex outcomes and model more closely the effect of deep space radiation on the human BBB. In summary, our results present a human neurovascular model for space radiation studies and potential future automated payload adaptation, and suggest astrocyte regulatory mechanisms as targets for countermeasures to mitigate human neurovascular impairments during deep space exploration.

Ionizing radiation↗

Dipole analysis on EGRET data of extragalactic gamma ray background radiation

A dipole analysis on the EGRET (Energetic Gamma-Ray Experimental Telescope) data seems to be one of the numerous subjects that can be investigated for the extragalactic gamma ray background radiation. By the end of the first one and half years after launch, the all-sky survey program of GRO (Gamma Ray Observatory) will be completed. The EGRET detector will cover the full sky area fairly well by that time. A set of gamma ray data suitable for dipole moment calculations will be available. Furthermore, there now exist in the literature several dipole anisotropy results calculated for optical and infrared observations on the distribution of galaxies in the full sky. The results of dipole moment analysis from gamma ray observation can be compared with those at other wavebands, and hopefully some deeper understanding can be gained on the large scale structure of the Universe.

Lin, Ying-Chi↗

Calibration of the active radiation detector for Spacelab-One

The flight models of the active radiation detector (ARD) for the ENV-01 environmental monitor were calibrated using gamma radiation. Measured sensitivities of the ion chambers were 6.1 + or - 0.3 micron rad per count for ARD S/N1, and 10.4 + or - 0.5 micron rad per count for ARD S/N2. Both were linear over the measured range 0.10 to 500 m/rad hour. The particle counters (proportional counters) were set to respond to approximately 85% of minimum ionizing particles of unit charge passing through them. These counters were also calibrated in the gamma field.

Source record↗

Extension of Cable Electrical Assessment Techniques to Detect and Discriminate Radiation Aging on Cable Insulation Systems (Abstract)

The purpose of this study of the electrical responses of gamma radiation aged low voltage nuclear cables is to advance tools to determine cable condition (extent of damage) and identify degradation location along the cable length. The developed technology will provide nuclear plant operators with the options to focus cable repair, mitigation, or replacement efforts locally and avoid wholesale cable replacement.

42 ENGINEERING↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray imaging of inertial confinement fusion implosions reveals remaining ablator carbon distribution

The joint LANL/LLNL nuclear imaging team has acquired the first gamma-ray images of inertial confinement fusion implosions at the National Ignition Facility. The gamma-ray image provides crucial information to help characterize the inertially confined fuel and ablator assembly at stagnation, information that would be difficult to acquire from neutron or x-ray observations. Gamma imaging visualizes both gamma radiation emitted directly in deuterium–tritium (DT) fusion reactions as well as gamma rays produced when DT fusion neutrons scatter inelastically on carbon nuclei in the remaining ablator of the fuel capsule. The resulting image provides valuable information on the position and density of the remaining ablator and potential contamination of the hot spot—a powerful diagnostic window into the capsule assembly during burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EGRET high-energy gamma-ray pulsar studies. 1: Young spin-powered pulsars

As part of its ongoing survey of the high-energy gamma-ray sky, the Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory has searched for emission from spin-powered pulsars, five of which have now been detected in the energy range 30 MeV less than or = E less than or = 20 GeV. A systematic study of the all-sky survey has found no additional pulsed gamma-ray sources. The pulsar detections, coupled with the upper limits on pulsed gamma radiation from other radio pulsars, indicate that the simplest models of gamma-ray pulsars are incomplete.

Thompson, D. J.↗

High-energy gamma-ray astronomy

The subject of gamma-ray astronomy is discussed with emphasis on celestial gamma rays with energies in excess of 10 MeV. Early observations of such gamma rays are reviewed, a gamma-ray spark-chamber telescope is described together with a gas Cerenkov-counter telescope, and the gamma-ray sky is delineated. It is shown that the diffuse high-energy gamma radiation from the galactic plane probably results primarily from cosmic-ray interactions with interstellar matter. Mechanisms for gamma-ray production are identified, and it is noted that the general galactic radiation may prove to be of great value in studies of galactic structure. Possible sources are considered for the diffuse celestial radiation, and discrete sources are described, including the Crab pulsar, the Vela remnant, the Cygnus region, and Gould's Belt. Future developments in gamma-ray astronomy are considered.

Fichtel, C.↗

Effects of Ionizing Radiation on the Thermodynamic Stability of Boehmite and Gibbsite

Here, in this study, we examined the effect of gamma radiation on the stabilities of aluminum hydroxide (gibbsite) and aluminum oxyhydroxide (boehmite) nanoparticles in relation to their thermal decomposition. X-ray diffraction (XRD) patterns and scanning electron microscopy (SEM) images revealed no significant differences in mineral components or morphology before and after radiation. However, thermogravimetric and differential scanning calorimetry (TGA/DSC) analyses showed that both boehmite and gibbsite nanoparticles experienced decreased mass loss following irradiation. Raman and attenuated total reflection-Fourier transfer infrared (ATR-FTIR) spectra indicated that a fraction of the hydroxyl content in both cases was selectively cleaved by radiation, primarily at the particle surfaces. Quantitative analyses of thermal mass loss behavior demonstrated that irradiated boehmite and gibbsite nanoparticles had higher activation energies than their pristine counterparts, with the extent of the increase dependent on the total dose. Taken together, these findings suggest that exposure to a sufficient dose of ionizing radiation alters these materials such that they are less prone to decomposition by dehydration. This increased stability may be due to the decreased hydrous nature of the samples after radiation exposure, which was supported by further high temperature drop calorimetry. Additionally, a radiation-induced amorphous phase on the nanoparticle surfaces appears to have a permanent and positive influence on their thermodynamic stabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗