Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identification and Suppression of Point Defects in Bromide Perovskite Single Crystals Enabling Gamma‐Ray Spectroscopy

Abstract Methylammonium lead tribromide (MAPbBr 3 ) stands out as the most easily grown wide‐band‐gap metal halide perovskite. It is a promising semiconductor for room‐temperature gamma‐ray ( γ ‐ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance. Here, through a combination of crystal growth design and defect characterization, including positron annihilation and impedance spectroscopy, the presence of specific point defects are identified and correlated to detector performance. Methylammonium (MA) vacancies, MA interstitials, and Pb vacancies are identified as the dominant charge‐trapping defects in MAPbBr 3 crystals, while Br vacancies caused doping. The addition of excess MABr reduces the MA and Br defects and so enables the detection of energy‐resolved γ ‐ray spectra using a MAPbBr 3 single‐crystal device. Interestingly, the addition of formamidinium (FA) cations, which converted to methylformamidinium (MFA) cations by reaction with MA + during crystal growth further reduced MA defects. This enabled an energy resolution of 3.9% for the 662 keV 137 Cs line using a low bias of 100 V. The work provides direction toward enabling further improvements in wide‐bandgap perovskite‐based device performance by reducing detrimental defects.

Ni, Zhenyi↗

Gamma-ray signatures of 𝑟-process radioactivity from the collapse of magnetized white dwarfs

We predict the gamma-ray line emission from 𝑟-process nuclei synthesized in the ejecta of the accretion-induced collapse (AIC) of a magnetized, rapidly rotating white dwarf. Using ejecta from a two-dimensional general-relativistic neutrino-magnetohydrodynamic simulation, further evolved with a radiation-hydrodynamics code coupled to an in situ nuclear reaction network, we construct angle-dependent gamma-ray spectra in the 0.01–10 MeV band via composition-dependent ray tracing through the ejecta. The emission between ∼1 and 10 d is dominated by 132 I (𝑡 1/2 = 2.3 h), continuously replenished by the decay of its parent 132 Te (𝑡 1/2 = 3.2 d), with additional contributions from 131 I, 133 Xe, and 132 Te . At 𝑡 ≳ 20 d, 56 Co (from 56 Ni decay) becomes the primary emitter. The simultaneous presence of 𝑟 process and iron-peak gamma-ray lines is distinctive of AIC ejecta and absent in binary neutron star mergers, where iron-peak nuclei are generally not synthesized. Comparing with the 3⁢𝜎 continuum sensitivities of planned MeV gamma-ray telescopes (COSI, AMEGO-X, e-ASTROGAM, GRAMS, GammaTPC), we find the brightest 𝑟-process lines detectable to ∼10 Mpc by GammaTPC and GRAMS, with the signal approaching their sensitivity threshold at 30 Mpc. As a result, the 𝑟-process spectral features survive time integration over ∼30 d exposures, demonstrating robustness against the long observation times required by gamma-ray detectors.

Nuclear reactions↗

Study of proton and neutron activation of metal samples in low Earth orbit

The analysis of the gamma-ray spectra taken from samples flown in Spacelab 1; the search for and review of neutron and proton activation cross-sections needed to analyze the results of the Long Duration Exposure Facility (LDEF) activation measurements; additional calculations of neutron induced activation for the LDEF samples; the data analysis plan for the LDEF and Spacelab 2 samples; the measurement of relevant cross-sections with activation of samples of V, Co, In, and Ta at the Indiana University Cyclotron Facility; and the preparation of an extended gamma-ray calibration source through the development of a proper technique to accurately deposit equal quantities of radioactive material onto a large number of point on the source are discussed.

Laird, C. E.↗

An Online Change of Activity in Energy Spectrum for Detection on an Early Intervention Robot

With the growth of industrial risks and the multiplication of CBRNe (Chemical Biological Radiological and explosive) attacks through toxic chemicals, biological or radiological threats, public services and military authorities face with increasingly critical situations, whose management is strongly conditioned by fast and reliable establishment of an informative diagnostic. Right after an attack, the five first minutes are crucial to define the various scenarios and the most dangerous for a human intervention. Therefore the use of robots is considered essential by all stakeholders of security. In this context, the SISPEO project (Systeme d'Intervention Sapeurs Pompiers Robotise) aims to create/build/design a robust response through a robotic platform for early intervention services such as civil and military security in hostile environments. CEA LIST has proposed an adapted solution to detect and characterize nuclear and radiological risks online and in motion, using a miniature embedded CdZnTe (CZT) crystal Gamma-ray spectrometer. This paper presents experimental results for this miniature embedded CZT spectrometer and its associated mathematical method to detect and characterize radiological threats online and in motion. (authors)

42 ENGINEERING↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DISCOVERY OF AN X-RAY-EMITTING CONTACT BINARY SYSTEM 2MASS J11201034−2201340

We report the detection of orbital modulation, a model solution, and the X-ray properties of a newly discovered contact binary, Two Micron All Sky Survey (2MASS) J11201034−2201340. We serendipitously found this X-ray point source outside the error ellipse when searching for possible X-ray counterparts of γ-ray millisecond pulsars among the unidentified objects detected by the Fermi Gamma-ray Space Telescope. The optical counterpart of the X-ray source (unrelated to the γ-ray source) was then identified using archival databases. The long-term Catalina Real-Time Transient Survey detected a precise signal with a period of P=0.28876208(56) days. A follow-up observation made by the Super Light Telescope of Lulin Observatory revealed the binary nature of the object. Utilizing archived photometric data of multi-band surveys, we construct the spectral energy distribution (SED), which is well fit by a K2V spectral template. The fitting result of the orbital profile using the Wilson–Devinney code suggests that 2MASS J11201034-2201340 is a short-period A-type contact binary and the more massive component has a cool spot. The X-ray emission was first noted in observations made by Swift, and then further confirmed and characterized by an XMM-Newton observation. The X-ray spectrum can be described by a power law or thermal Bremsstrahlung. Unfortunately, we could not observe significant X-ray orbital modulation. Finally, according to the SED, this system is estimated to be 690 pc from Earth with a calculated X-ray intensity of (0.7−1.5)×10{sup 30} erg s{sup −1}, which is in the expected range of an X-ray emitting contact binary.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiological Anomaly Detection And Identification (RADAI) v1.0

The Radiological Anomaly Detection and Identification (RADAI) software package is a python library for implementing, training, and storing algorithms that detect and identify anomalies in gamma-ray spectra. The library defines a general framework for implementing detection (binary) and identification (classification) algorithms, objects to encapsulate the results of analyses, a variety of temporal filtering tools that can be used in constructing algorithms, and conceptual design that allows easy reading and writing of algorithms (and their time dependent state). In addition to this framework, the library includes implementations of a variety of algorithms from the scientific literature including: gross-counts k-sigma, SPRT, N-SCRAD, Region of Interest, and Censored Energy Window. The implementation of these algorithms within the RADAI package was done to facilitate user-initiated training and configuration to by applied to different gamma-ray detector types. Finally, benchmarked and synthetic datasets will be made available for standardized algorithm characterization with corresponding utilities in the RADAI package for data access and processing.

Joshi, Tenzing↗

Retrieving DSD Moments from GPM-DPR: A Simulation Study Based on the Full DSD Spectra Characterized by the Generalized Gamma Model

Recently, a method to retrieve rain drop size distribution (DSD) moments from X-band dual polarization radar measurements has been developed using copolar reflectivity, differential reflectivity and specific attenuation. Two reference moments are retrieved first, followed by reconstructing the DSDs and calculating other moments using a generalized gamma model to represent the underlying shape, h(x), corresponding to the pair of chosen reference moments. Here we explore a similar approach but the retrieval method in this study uses dual-frequency radar measurements. In the case of GPM-DPR, the two frequencies are 13.8and 35 GHz, and their products include attenuation corrected reflecivities at both frequencies (Z and Z) and the specific attenuation (k, k, if available). Our approach is to use these products to determine two reference moments, namely M3 andM6 representing the third and the sixth moments respectively. Then, as with the polarimetric radar retrievals, we use the most probable h(x) to reconstruct the full DSD spectra, from which other moments are calculated. The best two DPR products for estimating M3 and M6 appear to be A and Z. Figure 1 shows the retrievals versus the ‘true’ moments. 2930 three-minute DSDs were used for the (T-matrix) scattering calculations at Ku and Ka bands but only cases with A > 0.5 dB/km were chosen. For the retrieved moments, the integration was performed only up to 6 mm drop diameter. The [1:1] line is included in Fig. 1. Even with just two DPR products as input the results seem promising, although the lower order moments show somewhat more scatter, especially the zeroth moment, M0. We will quantify the retrieval errors, and additionally examine the stability of h(x). For the latter, data from (i) Greeley, Colorado, (ii) Huntsville, Alabama, and (iii)Wallops, Virginia, will be used. Finally, a GPM overpass case over Huntsville, during a widespread rain event on 11 April 2016, will be considered as an initial test case.

precipitation↗

Left–right asymmetry in integral spectra of γ-quanta in the interaction of nuclei with polarized thermal neutrons

The paper presents results of preliminarymeasurements of the left–right asymmetry in integral spectra of γ-quanta emitted in the interaction of polarized thermal neutrons with nuclei. These results indicate that for all cases of measured statistically significant P-odd asymmetry, the left–right asymmetry coefficient is much smaller than the P-odd asymmetry coefficient. This observation is not consistent with the predictions of theoretical calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Angular Distributions of Gamma Rays from the Inelastic Scattering of 14.1-MeV Neutrons by Carbon and Oxygen Nuclei

The results obtained by measuring the angular and energy distributions of gamma rays originating from the inelastic scattering of 14.1-MeV neutrons by carbon and oxygen nuclei are presented. The measurements in question were performed by the tagged-neutron method in a beam of an ING-27 standard portable neutron generator. The angular distributions of gamma rays emitted by the 2{sup +} state of {sup 12}С at 4.43 MeVand the 3{sup −} state of {sup 16}O at 6.13 MeV were obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for New Cosmic-Ray Acceleration Sites within the 4FGL Catalog Galactic Plane Sources

Cosmic rays are mostly composed of protons accelerated to relativistic speeds. When those protons encounter interstellar material, they produce neutral pions, which in turn decay into gamma-rays. This offers a compelling way to identify the acceleration sites of protons. A characteristic hadronic spectrum, with a low-energy break around 200 MeV, was detected in the gamma-ray spectra of four supernova remnants (SNRs), IC 443, W44, W49B, and W51C, with the Fermi Large Area Telescope. This detection provided direct evidence that cosmic-ray protons are (re-)accelerated in SNRs. Here, we present a comprehensive search for low-energy spectral breaks among 311 4FGL catalog sources located within 5° from the Galactic plane. Using 8 yr of data from the Fermi Large Area Telescope between 50 MeV and 1 GeV, we find and present the spectral characteristics of 56 sources with a spectral break confirmed by a thorough study of systematic uncertainty. Our population of sources includes 13 SNRs for which the proton–proton interaction is enhanced by the dense target material; the high-mass gamma-ray binary LS I+61 303; the colliding wind binary η Carinae; and the Cygnus star-forming region. This analysis better constrains the origin of the gamma-ray emission and enlarges our view to potential new cosmic-ray acceleration sites.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of Space Experiments for Nuclear Planetology: Measurement of Relative Intensities of Lines of Gamma Ray Emitted upon Thermal-Neutron Capture by Nuclei

The results obtained by experimentally studying gamma rays emitted by samples prepared as analogs of planetary matter and irradiated with thermal neutrons are presented. The intensities of spectral lines of gamma rays emitted by such samples differing in chemical composition are compared. These results will be used in processing data on gamma-ray spectra of the Moon and Mercury from measurements performed onboard spacecrafts with the aim of studying the composition of the surface of these celestial bodies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray and gamma-ray emissions expected from supernova 1987A

The X-ray and gamma-ray spectra expected from SN 1987A have been calculated. Results for the TWOBF7 model are inconsistent with Ginga observation, but the X-ray flux and its spectral shape strongly depend on the chemical composition and expansion velocity of the ejecta. The distributions of density and chemical compositions for SN 1987A are described. For the TWOBF7 model, the X-ray flux between 10 and 20 keV reaches a peak of 6.7 photons/s/sq m about 1 yr after the explosion. For the 15B5 model, the peak flux is larger by a factor of five. The implications of the Ginga satellite's detection of an excess X-ray flux from the direction of the supernova for the models of SN 1987A are considered. How observations of gamma-ray lines can determine the optical thickness of the expanding shell is discussed.

Ebisuzaki, Toshikazu↗

Validation of a Monte Carlo HPGe detector model against irradiated foil gamma-ray spectroscopy measurements

In this study, a high-purity germanium detector Monte Carlo model was evaluated for its ability to predict activation product ratios in Fe, Cr, Ni, and stainless-steel foils. To evaluate the model, activation product ratios calculated from simulated gamma-ray spectra were compared against those from experiment measurements. Analysis shows that the detector model accurately predicts activation product ratios within 10% when free of interferences. Presence of a shield chamber greatly increases computation time, but does not provide any quantitative advantages. Overall, the model is useful for predicting activation product ratios and experiment planning.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Chemical Composition Analysis for X-Ray Transport Container Scans

It is important for national security to control the movement of dangerous or strategically cargo such as explosives, radioactive materials, rare and precious metals. This control can be provided by scanning transport containers by gamma rays. In this report the existing technique for scanning (dual energy method) is considered and the alternative method based on measuring the energy distribution of gamma rays is proposed. For estimation perspectives of the proposing method, the corresponding simulation was conducted by using the GEANT4 toolkit. The example of the algorithm of reconstruction the chemical composition of the scanned object is also considered. In addition the experiment for estimation energy resolution of the detector based on a scintillation crystal BGO and SiPM was carried out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE GIGAELECTRONVOLT COUNTERPART OF VER J2019+407 IN THE NORTHERN SHELL OF THE SUPERNOVA REMNANT G78.2+2.1 ( γ Cygni)

Analysis of gamma-ray emission from the supernova remnant G78.2+2.1 ( γ Cygni) with 7.2 years of cumulative data from the Fermi Large Area Telescope shows a distinct hard, bright, and extended component to the north of the shell coincident with the known teraelectronvolt source VER J2019+407. In the gigaelectronvolt to teraelectronvolt (GeV–TeV) energy range, its spectrum is best described by a broken power law with indices 1.8 below a break energy of 71 GeV and 2.5 above the break. A broadband spectral energy distribution is assembled, and different scenarios for the origin of the gamma rays are explored. Both hadronic and leptonic mechanisms are able to account for the GeV–TeV observations. In the leptonic framework, a superposition of inverse Compton and nonthermal bremsstrahlung emissions is needed, whereas the hadronic scenario requires a cosmic-ray population described by a broken power-law distribution with a relatively hard spectral index of ∼1.8 below a break particle energy of 0.45 TeV. In addition, the neutrino flux expected from cosmic-ray interactions is calculated.

79 ASTRONOMY AND ASTROPHYSICS↗

3C 279 IN OUTBURST IN 2015 JUNE: A BROADBAND SED STUDY BASED ON THE INTEGRAL DETECTION

Blazars radiate from radio through gamma-ray frequencies and thereby make ideal targets for multifrequency studies. Such studies allow the properties of the emitting jet to be constrained. 3C 279 is among the most notable blazars and therefore subject to extensive multifrequency campaigns. We report the results of a campaign ranging from near-IR to gamma-ray energies that targeted an outburst of 3C 279 in 2015 June. The campaign pivots around the detection in only 50 ks by INTEGRAL , whose IBIS/ISGRI data pin down the high-energy component of the spectral energy distribution (SED) between Swift -XRT data and Fermi -LAT data. The overall SED from near-IR to gamma rays can be well represented by either a leptonic or a lepto-hadronic radiation transfer model. Even though the data are equally well represented by the two models, their inferred parameters challenge the physical conditions in the jet. In fact, the leptonic model requires parameters with a magnetic field far below equipartition with the relativistic particle energy density. In contrast, equipartition may be achieved with the lepto-hadronic model, although this implies an extreme total jet power close to the Eddington luminosity.

79 ASTRONOMY AND ASTROPHYSICS↗