Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Lamellar {gamma}-AlOOH architectures: Synthesis and application for the removal of HCN

Using hexadecyl trimethyl ammonium bromide (CTAB) as a structure-directing agent and precipitator, the complete synthesis of lamellar {gamma}-AlOOH architectures was successfully accomplished via a hydrothermal route. Different product structures were obtained by varying the molar ratio of aluminum nitrate and CTAB. Several techniques, including X-ray powder diffraction, Fourier transform infrared spectroscopy, field-emission scanning electron microscopy, transmission electron microscopy, and differential scanning calorimetry thermal analysis, were used to characterize the products. The effects of CTAB concentration, reaction temperature and time, and the molar ratio of Al{sup 3+}/CTAB on the product morphologies were investigated. The nitrogen adsorption and desorption measurements indicated that the {gamma}-AlOOH architectures possess a Brunauer-Emmett-Teller surface area of approximately 75.02 m{sup 2}/g. It was also demonstrated that 10 mg {gamma}-AlOOH architectures can remove 45.3% of the HCN (1.68 {mu}g/mL) from model wastewater. When 0.03 mg/cig {gamma}-AlOOH architectures were combined with cigarette paper, 8.12% of the present HCN was adsorbed. These results indicate that lamellar {gamma}-AlOOH architectures may be a potential adsorbent for removing HCN from highly toxic pollutant solutions and harmful cigarette smoke. Highlights: Black-Right-Pointing-Pointer Hexadecyl trimethyl ammonium bromide (CTAB) was used as a structure-directing agent and precipitator. Black-Right-Pointing-Pointer Hydrothermal treatment enables growth of lamellar {gamma}-AlOOH architectures. Black-Right-Pointing-Pointer Lamellar {gamma}-AlOOH architectures were demonstrated to exhibit high BET surface area and excellent adsorptive capacity. Black-Right-Pointing-Pointer HCN in contaminated water and cigarette smoke can be effectively removed by the prepared lamellar {gamma}-AlOOH superstructures.

36 MATERIALS SCIENCE↗

Mid-infrared spectroscopic study of crystallization of cubic spinel phase from metakaolin

The structural changes during thermal conversion of metakaolinite into cubic spinel phase that was in literature considered as Al-Si spinel or {gamma}-Al{sub 2}O{sub 3} were investigated by mid-infrared spectroscopy (FT-IR) and differential scanning calorimetry (DSC) using medium ordered kaolin with high content of kaolinite. Spectrum features were studied in the mid-infrared region from 4000 to 400 cm{sup -1} as function of fractional conversion that resulted from DSC experiments. The increasing contends of Al-O bonds in the octahedral position (AlO{sub 6}) was observed during thermal transformation. The high ratio of antisymmetric stretching of {identical_to}Si-O-Al= and {identical_to}Si-O-Si{identical_to} bands and bands belonging to stretching of =Al-O bonds in the (AlO{sub 4}) tetrahedra and (AlO{sub 6}) octahedra decreases exponentially with fractional conversion. The antisymmetric stretching band of {identical_to}Si-O-Si{identical_to} bond in the (SiO{sub 4}) tetrahedra becomes more expressive due to formation of amorphous SiO{sub 2} phase. - Graphical abstract: The thermal conversion of metakaolinite into spinel phase was investigated by mid-infrared spectroscopy to found relationship between bands features and fractional convesrion. Highlights: > Formation of spinel phase from metakaolinite was studied by FT-IR. > Relationship between spectrum features and fractional conversion was investigated. > Intensity ratios of (AlO{sub 4}) and (AlO{sub 6}) decreases exponentially. > Antisymmetric stretching of (SiO{sub 4}) becomes more expressive during transformation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water

Purpose: To test the use of a three-dimensional (3D) optical cone beam computed tomography reconstruction algorithm, for estimation of the imparted 3D dose distribution from megavoltage photon beams in a water tank for quality assurance, by imaging the induced Cherenkov-excited fluorescence (CEF). Methods: An intensified charge-coupled device coupled to a standard nontelecentric camera lens was used to tomographically acquire two-dimensional (2D) projection images of CEF from a complex multileaf collimator (MLC) shaped 6 MV linear accelerator x-ray photon beam operating at a dose rate of 600 MU/min. The resulting projections were used to reconstruct the 3D CEF light distribution, a potential surrogate of imparted dose, using a Feldkamp–Davis–Kress cone beam back reconstruction algorithm. Finally, the reconstructed light distributions were compared to the expected dose values from one-dimensional diode scans, 2D film measurements, and the 3D distribution generated from the clinical Varian ECLIPSE treatment planning system using a gamma index analysis. A Monte Carlo derived correction was applied to the Cherenkov reconstructions to account for beam hardening artifacts. Results: 3D light volumes were successfully reconstructed over a 400 × 400 × 350 mm{sup 3} volume at a resolution of 1 mm. The Cherenkov reconstructions showed agreement with all comparative methods and were also able to recover both inter- and intra-MLC leaf leakage. Based upon a 3%/3 mm criterion, the experimental Cherenkov light measurements showed an 83%–99% pass fraction depending on the chosen threshold dose. Conclusions: The results from this study demonstrate the use of optical cone beam computed tomography using CEF for the profiling of the imparted dose distribution from large area megavoltage photon beams in water.

07 ISOTOPE AND RADIATION SOURCES↗

TRANSFER LEARNING FOR FIELD EMISSION MITIGATION IN CEBAF SRF CAVITIES

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab operates hundreds of super-conducting radio frequency (SRF) cavities in its two linear accelerators (linacs). Field emission (FE) is an ongoing operational challenge in higher gradient SRF cavities. FE generates high levels of neutron and gamma radiation leading to damaged accelerator hardware and a radiation hazard environment. During machine development periods, we performed gradient scans to record data capturing the relationship between cavity gradients and radiation levels measured throughout the linacs. However, the field emission environment at CEBAF varies considerably over time as the configuration of the radio frequency (RF) gradients changes and due to the changing behaviour of field emitters. An artificial intelligence/machine learning (AI/ML) approach with transfer learning could be a valuable tool to mitigate FE and lower the radiation levels. In this work, we mainly focus on leveraging the RF trip data gathered during CEBAF operations. We develop a transfer learning-based surrogate model for radiation detector readings given RF cavity gradients to track the CEBAF?s changing configuration and environment. Then, we could use the developed model as an optimization process for redistributing the RF gradients within a linac to minimize radiation levels.

Ahammed, K.↗

TRANSFER LEARNING FOR FIELD EMISSION MITIGATION IN CEBAF SRF CAVITIES

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab operates hundreds of super-conducting radio frequency (SRF) cavities in its two linear accelerators (linacs). Field emission (FE) is an ongoing operational challenge in higher gradient SRF cavities. FE generates high levels of neutron and gamma radiation leading to damaged accelerator hardware and a radiation hazard environment. During machine development periods, we performed gradient scans to record data capturing the relationship between cavity gradients and radiation levels measured throughout the linacs. However, the field emission environment at CEBAF varies considerably over time as the configuration of the radio frequency (RF) gradients changes and due to the changing behaviour of field emitters. An artificial intelligence/machine learning (AI/ML) approach with transfer learning could be a valuable tool to mitigate FE and lower the radiation levels. In this work, we mainly focus on leveraging the RF trip data gathered during CEBAF operations. We develop a transfer learning-based surrogate model for radiation detector readings given RF cavity gradients to track the CEBAF?s changing configuration and environment. Then, we could use the developed model as an optimization process for redistributing the RF gradients within a linac to minimize radiation levels.

Ahammed, K.↗

CACTI CSAPR2 Taranis Retrievals

Taranis is an end-to-end processing chain for radar data written in Python with C extension for computation performance. Features include: masking for quality control, specific differential phase (Kdp), attenuation correction for reflectivity factor (Z) and differential reflectivity (Zdr) in rain, and additional geophysical retrievals. Retrievals are mostly drawn from literature or open-source software when appropriate, and have been tested, tuned, and modified to work with one another cohesively rather than using isolated off-the-shelf algorithms. Incorporated algorithms include hydrometeor (echo) identification, rain water content, raindrop mass-weighted mean diameter (gamma size distribution assumption), and rainfall rate (QPE). Taranis data sets exist for CSAPR2 PPI, HSRHI, and sector RHI scans. Cartesian-gridded data sets were also produced as well as a near-surface rain rate retrieval. More details can be found in the README.

54 ENVIRONMENTAL SCIENCES↗

Systems for detecting charged particles in object inspection

Techniques, apparatus and systems for detecting particles such as muons. In one implementation, a monitoring system has a cosmic ray-produced charged particle tracker with a plurality of drift cells. The drift cells, which can be for example aluminum drift tubes, can be arranged at least above and below a volume to be scanned to thereby track incoming and outgoing charged particles, such as cosmic ray-produced muons, while also detecting gamma rays. The system can selectively detect devices or materials, such as iron, lead, gold and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can also detect any radioactive sources occupying the volume from gamma rays emitted therefrom. If necessary, the drift tubes can be sealed to eliminate the need for a gas handling system. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal and Gamma-ray induced relaxation in As-S glasses: modeling and experiment

Enthalpy relaxation is measured in a series of As-S glasses irradiated with gamma rays and these samples are compared with a set of identical control samples kept in the dark. It is shown that gamma irradiation lifts the kinetic barrier for relaxation at room temperature and speeds up the enthalpy release. The measured values of thermal relaxation in the dark agree closely with modeling results obtained by fitting differential scanning calorimetry curves with the TNM equations. The measured values of activation energy for enthalpy relaxation are also in close agreement with that predicted by the TNM model therefore lending credence to the fitting results. These measurements permit extraction of the effect of gamma irradiation on the glass structure for a series of As-S glasses with increasing structural coordination, and gamma irradiation is shown to reduce the structural relaxation time. It is also shown that lower coordination glasses exhibit greater radiation sensitivity but also greater thermal relaxation due to their lower Tg. On the other end, over-coordinated glasses show lower relaxation and almost no radiation sensitivity. This behavior is similar to the glass response under sub-bandgap light irradiation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Catalysis study for space shuttle vehicle thermal protection systems

Experimental results on the problem of reducing aerodynamic heating on space shuttle orbiter surfaces are presented. Data include: (1) development of a laboratory flow reactor technique for measuring gamma sub O and gamma sub N on candidate materials at surfaces, T sub w, in the nominal range 1000 to 2000, (2) measurements of gamma sub O and gamma sub N above 1000 K for both the glass coating of a reusable surface insulation material and the siliconized surface of a reinforced pyrolyzed plastic material, (3) measurement of the ablation behavior of the coated RPP material at T sub w is greater than or equal to 2150 K, (4) X-ray photoelectron spectral studies of the chemical constituents on these surfaces before and after dissociated gas exposure, (5) scanning electron micrograph examination of as-received and reacted specimens, and (6) development and exploitation of a method of predicting the aerodynamic heating consquences of these gamma sub O(T sub w) and gamma sub N(T sub w) measurements for critical locations on a radiation cooled orbiter vehicle.

Breen, J.↗

An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan

Purpose: Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurement in a single scan and enables measurement results to be obtained in less than 30 min. This avoids complications due to postexposure changes in radiochromic film that delay the completion of a measurement, often for up to 24 h, in commonly used methods. In addition, the protocol addresses the accuracy and integrity of the measurement by eliminating environmental and interscan variability issues. Methods: The authors collected dose-response data from six production lots of Gafchromic EBT3 film and three production lots of EBT2 film at doses up to 480 cGy. In this work, the authors used seven different scanners of two different models-Epson 10000XL and V700; postexposure times before scanning from 30 min to 9 days; ambient temperatures for scanning spanning 11 Degree-Sign C; and two film orientations. Scanning was in 48-bit RGB format at 72 dpi resolution. Dose evaluation was conducted using a triple-channel dosimetry method. To evaluate the measurement protocol, patient specific IMRT and volumetric modulated arc therapy (VMAT) plans were exposed onto EBT3 films on a Varian Trilogy Linac. Film scanning was done following the protocol under a number of different conditions and the dose maps were analyzed to demonstrate the equivalence of results. Results: The results indicated that the dose-response data could be fit by a set of related rational functions leading to the description of a generic calibration curve. A simplified dosimetry protocol was established where dose-response data for a specific film lot, scanner, and scanning conditions could be derived from two films exposed to known doses. In most cases only one calibrated exposure was required since the dose for one of the films could be zero. Using the Gamma test criterion of 2%/2 mm to evaluate the measurements, similar passing rates ranging between about 95% and 99% for the fields studied were obtained from application films digitized under a variety of conditions all of them different than the conditions under which the calibration films were scanned. Conclusions: The authors have developed a simplified and efficient protocol to measure doses delivered by an IMRT or VMAT plan using only the patient film, one calibration film, one unexposed film, and applying a single scan to acquire a digital image for calculation and analysis. The simplification and timesaving offer a potential practical solution for using radiochromic film for routine treatment plan quality assurance without sacrificing spatial resolution for convenience.

07 ISOTOPE AND RADIATION SOURCES↗

Microstructural characterization and dry sliding wear resistance of MoO{sub 2}-strengthened {gamma}/NiMo alloys with different primary phases

Two {gamma}/NiMo alloys strengthened by a refractory metal oxide MoO{sub 2} phase were fabricated by a laser melting deposition process. Microstructural transformation of the alloys with different primary phases was identified and the crystal structure of the primary phases was confirmed by both X-ray diffraction and transmission electron microscopy. Meanwhile, room-temperature dry sliding wear behavior and mechanism difference of the alloys were also investigated mainly by scanning electron microscopy. Microstructures of the alloys varied from hypoeutectic to hypereutectic, as the molybdenum content increases. The hypoeutectic alloy was solidified on the basis of a Ni-base solid solution {gamma} primary phase, whereas the hypereutectic alloy was grown based on an intermetallic compound with NiMo primary phase. The {gamma}, NiMo primary phases and MoO{sub 2} strengthening phase were confirmed to have face-centered cubic, orthorhombic and monoclinic structures, respectively. Compared with the hypoeutectic alloy, the hypereutectic alloy exhibited higher wear resistance under the same condition. The predominant wear mechanism of the {gamma}/NiMo alloys transformed from micro-cutting to microcracking.

36 MATERIALS SCIENCE↗

Optical and Structural Characterizations of Tin Phthalocvanine Thin Films

Phthalocyanines are today regarded as optical materials, which applies to organic dye lasers. The analysis of the optical properties of these thin films enforces the application in the field of thin film optics. Tin phthalocyanine (SnPc) thin films used for the characterization studies are prepared by thermal evaporation technique. The variation of optical band gap with irradiation of heat radiation and post deposition heat treatment are studied from the absorption spectra. Structural properties have been analyzed using the X-ray diffractogram of SnPc powder and thin films. The structure is identified as monoclinic with a = 12.132 A, b = 8.712 A, c = 10.806 A and {beta} = 108.85 deg. The grain size increases with increase of annealing temperature. The SEM images show a rough corrugated surface. Due to heat treatment, crystallites grow into bigger size.

36 MATERIALS SCIENCE↗

Facile Synthesis of Silver Nanoparticles Under {gamma}-Irradiation: Effect of Chitosan Concentration

In the present study, a biopolymer, low molecular weight chitosan had been utilized as a 'green' stabilizing agent for the synthesis of silver nanoparticles under {gamma}-irradiation. The as-synthesized silver nanoparticles have particle diameters in the range of 5 nm-30 nm depending on the percentage of chitosan used (0.1 wt%, 0.5 wt%, 1.0 wt% and 2.0 wt%). It was found that the yield of the silver nanoparticles was in accordance with the concentration of chitosan presence in the solution due to the reduction by the chitosan radical during irradiation. The highly stable chitosan encapsulated silver nanoparticles were characterized using transmission electron microscopy (TEM), UV-Visible spectrophotometer (UV-VIS) and X-ray diffraction spectroscopy (XRD)

36 MATERIALS SCIENCE↗

Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry

Purpose: A known factor affecting the accuracy of radiochromic film dosimetry is the lateral response artifact (LRA) induced by nonuniform response of a flatbed scanner in the direction perpendicular to the scan direction. This work reports a practical solution to eliminate such artifacts for all forms of dose QA. Methods: EBT3 films from a single production lot (02181401) cut into rectangular 4 × 5 cm{sup 2} pieces, with the long dimension parallel to the long dimension of the original 20.3 × 25.4 cm{sup 2} sheets, were exposed at a depth of 5 cm on a Varian Trilogy at the center of a 20 × 20 cm{sup 2} open field at seven doses between 50 and 1600 cGy using 6 MV photons. These films together with an unexposed film from the same production lot were lined one next to the other on an Epson 10000XL or 11000XL scanner in portrait orientation with their long dimension parallel to the scan direction. Scanned images were then obtained with the line of films positioned at seven discrete lateral locations perpendicular to the scan direction. The process was repeated in landscape orientation and on three other Epson scanners. Data were also collected for three additional production lots of EBT3 film (11051302, 03031401, and 03171403). From measurements at the various lateral positions, the scanner response was determined as a function of the lateral position of the scanned film. For a given color channel X, the response at any lateral position L is related to the response at the center, C, of the scanner by Response(C, D, X) = A{sub L,X} + B{sub L,X}⋅Response(L, D, X), where D is dose and the coefficients A{sub L,X} and B{sub L,X} are determined from the film measurements at the center of the scanner and six other discrete lateral positions. The values at intermediate lateral positions were obtained by linear interpolation. The coefficients were determined for the red, green, and blue color channels, preserving the ability to apply triple-channel dosimetry once corrections were applied to compensate for the lateral position response artifact. To validate this method, corrections were applied to several films that were exposed to 15 × 15cm{sup 2} open fields and large IMRT and VMAT fields and scanned at the extreme edges of the scan window in addition to the central location. Calibration and response data were used to generate dose maps and perform gamma analysis using single- or triple-channel dosimetry with FilmQAPro 2014 software. Results: The authors’ study found that calibration curves at the different lateral positions could be correlated by a simple two-point rescaling using the response for unexposed film as well as the response of film exposed at high doses between 800 and 1600 cGy. The coefficients A{sub L,X} and B{sub L,X} for each color channel X were found to be independent of dose at each lateral location L. This made it possible to apply the relationship Response(C, D, X) = A{sub L,X} + B{sub L,X}⋅Response(L, D, X), to the raw film responses, permitting correction of the response values at any lateral position to an equivalent response, as if that part of the film was located at the center of the scanner. This correction method was validated for several films exposed to open as well as large IMRT and VMAT fields. Conclusions: The work reported elaborates on the process using the correction procedures to eliminate the lateral response artifact and demonstrates improvements in the accuracy of radiochromic film dosimetry for the radiation therapy quality assurance applications.

07 ISOTOPE AND RADIATION SOURCES↗

A-4 scientific results

Observations of galactic sources, extragalactic sources and gamma bursts with the A-4 instrument at energy 1 energies of between 0.1 to 10 MeV are discussed. Aximuthal scans are presented. The Crab Nebula and its spectrum and the spectrum of Cygnus Z-1 are described.

Matteson, J.↗

HEAO 3 discovery of Al-26 in the interstellar medium

A new analysis technique was used with HEAO 3 satellite gamma ray data to quantify the galactic 1809 keV emission. A method of bins was applied in summing for specific scan directions, followed by fitting the source and background components. The 1809 keV line of Al-26 was significant because of the recent discovery that Al-26 was overabundant in meteoritic material and implanted during solar system formation. The HEAO 3 flux indicated a current decay of 3 solar masses of Al-26 per year in the interstellar medium, possibly occurring in red giants and massive main sequence stars. The ratio of the observed Al-26 to the Al-27 flux was similar to that measured in meteorites, which suggests that the ratio is normal for the galactic medium and that no supernova triggered the protosolar nebular collapse.

Mahoney, W. A.↗

Evaluation of a Fluorochlorozirconate Glass-Ceramic Storage Phosphor Plate for Gamma-Ray Computed Radiography

In this paper, a fluorochlorozirconate (FCZ) glass-ceramic containing orthorhombic barium chloride crystals doped with divalent europium was evaluated for use as a storage phosphor in gamma-ray imaging. X-ray diffraction and phosphorimetry of the glass-ceramic sample showed the presence of a significant amount of orthorhombic barium chloride crystals in the glass matrix. Transmission electron microscopy and scanning electron microscopy were used to identify crystal size, structure, and morphology. The size of the orthorhombic barium chloride crystals in the FCZ glass matrix was very large, ~0.5–0.7 μm, which can limit image resolution. The FCZ glass-ceramic sample was exposed to 1 MeV gamma rays to determine its photostimulated emission characteristics at high energies, which were found to be suitable for imaging applications. Test images were made at 2 MeV energies using gap and step wedge phantoms. Gaps as small as 101.6 μm in a 440 stainless steel phantom were imaged using the sample imaging plate. Analysis of an image created using a depleted uranium step wedge phantom showed that emission is proportional to incident energy at the sample and the estimated absorbed dose. Finally, the results showed that the sample imaging plate has potential for gamma-ray-computed radiography and dosimetry applications.

36 MATERIALS SCIENCE↗

SU-E-T-561: Development of Depth Dose Measurement Technique Using the Multilayer Ionization Chamber for Spot Scanning Method

Purpose: To develop a measurement technique which suppresses the difference between profiles obtained with a multilayer ionization chamber (MLIC) and with a water phantom. Methods: The developed technique multiplies the raw MLIC data by a correction factor that depends on the initial beam range and water equivalent depth. The correction factor is derived based on a Bragg curve calculation formula considering range straggling and fluence loss caused by nuclear reactions. Furthermore, the correction factor is adjusted based on several integrated depth doses measured with a water phantom and the MLIC. The measured depth dose profiles along the central axis of the proton field with a nominal field size of 10 by 10 cm were compared between the MLIC using the new technique and the water phantom. The spread out Bragg peak was 20 cm for fields with a range of 30.6 cm and 6.9 cm. Raw MLIC data were obtained with each energy layer, and integrated after multiplying by the correction factor. The measurements were performed by a spot scanning nozzle at Nagoya Proton Therapy Center, Japan. Results: The profile measured with the MLIC using the new technique is consistent with that of the water phantom. Moreover, 97% of the points passed the 1% dose /1mm distance agreement criterion of the gamma index. Conclusion: We have demonstrated that the new technique suppresses the difference between profiles obtained with the MLIC and with the water phantom. It was concluded that this technique is useful for depth dose measurement in proton spot scanning method.

07 ISOTOPE AND RADIATION SOURCES↗