Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Development of a Reference Design for a Cyber-Physical System

The purpose of this thesis is to develop a reference design to assist in the selection of security practices in power electronics design. A prototype will be developed from this reference design for evaluation. This evaluation will include a brief cost/benefit analysis to gauge the efficacy of implementing each layer of security throughout the power electronics design process. This thesis will also describe the obstacles and effectiveness of integrating a Trusted Platform Module (TPM) into a cyber-hardened grid-connected device. The TPM device is a secured crypto processor that assists in generating, storing, and restricting the use of cryptographic keys. The emphasis of this research is to establish integrity, authenticity, and confidentiality within a system by providing a baseline of security concerns for segments of the system. This research considers communication, control, and hardware level securities. The scope of this thesis will review the necessary security methods as well as consider the effects these methods have on the embedded system, to assess the desired security to responsiveness trade off. Applying this approach to a design process will alleviate various unknowns of appending security to a power electronics design. This thesis describes the specific vulnerabilities introduced within this grid-edge environment, and how the liabilities within the system can be mitigated. Initially, common security techniques will be considered to establish a guideline to benchmark performance and resource costs of the system. The foundation will be a non-hardened power electronic system platform with industry standard communication protocols. Several security techniques and attack vectors will then be evaluated to contribute to the base level platform. Other fail-safe features take place to gauge progress of the selected approach, non-inclusive to the TPM. Collectively, this investigation will determine a valid experiment by appraising and categorizing resource allocation, performance overhead, and monetary cost analysis results into a reference design. The prototype will then demonstrate methods to relieve common threats that are purposefully implemented into the design.

Blair, Nicholas Paul↗

Distributed Wind Controls: A Research Roadmap for Microgrids, Infrastructure Resilience, and Controls Launchpad (MIRACL)

The Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project’s controls research area aims to expand the benefits from distributed wind (DW) generation assets beyond solely providing low cost power directly to consumers. To make distributed wind turbines operate more effectively there is a need for more advanced ways to control them, allowing power companies, businesses, and energy consumers to take advantage of the unique characteristics of wind energy. DW can contribute to the safe and secure operation of grid by providing services such as voltage regulation, frequency regulation, spinning reserves, and even black start capabilities. In the larger DER context where much of the research has focused around solar technologies, the inertia available in wind technologies has generally not been considered. For wind turbines to provide these services in an optimal and expanded way, development and demonstration of control methods and communication interfaces within a grid and microgrid framework are required. In this document, NREL led the literature review in collaboration with SNL, of DER controls-focused integration research to establish a baseline for the controls research under the MIRACL project to identify specific control functions to be focused on throughout this project. This literature review focused primarily on the control functions of variable distributed generation, largely pulling from past solar PV and battery controls works, with a specific focus on applicability for distributed wind energy systems. The goal of this document is to identify a research roadmap based on the open literature and past national laboratory works to inform advanced wind turbine and power electronics control functions for four use cases: 1) distributed wind in isolated systems, 2) grid-connected microgrids (wind-hybrid systems and islanded operation), 3) behind-the-meter distributed wind applications in the power distribution systems, and 4) front-of-the-meter distributed wind applications in the power distribution systems.

17 WIND ENERGY↗

Power-Hardware-in-the-Loop Experiments of a Microgrid With a Grid-Forming Battery Inverter: Preprint

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-Hardware-in-the-Loop Experiments of a Microgrid with a Grid-Forming Battery Inverter

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermoeconomic analysis of residential rooftop photovoltaic systems with integrated energy storage and resulting impacts on electrical distribution networks

This paper investigates residential rooftop photovoltaic (PV) systems for long-term thermoeconomic benefits from PV homeowners’ perspectives and for impacts on the electrical distribution network from grid operators’ perspectives. The costs of generating electricity from grid-connected PV systems are studied with and without energy storage at the PV homeowners’ sites. Three selling scenarios for excess PV energy conversion are considered: net metering, wholesale pricing, and no payback. PV systems in Utah are utilized as case studies in this analysis. The presence of PV systems gives homeowners economic benefits such as reduced annual electricity bills. However, the levelized costs of electricity are considerably higher than the weighted electricity price in Utah. Currently, the addition of energy storage only benefits customers in Utah under the no payback policy. The impacts of PV systems toward electrical distribution networks are then studied on a distribution test system. Excess PV generation from residential PV systems causes voltage rise in the electrical distribution network. The results from this paper can educate consumers about the lifetime benefit of integrating solar energy into their homes. For grid operators, residential PV systems with energy storage can reduce the negative impacts on the grid compared with high PV penetration alone.

14 SOLAR ENERGY↗

Developing Technology Performance Level Assessments for Early-Stage Wave Energy Converter Technologies: Preprint

The advantage of using Technology Performance Level (TPL) in conjunction with Technology Readiness Level (TRL) assessments in guiding technology development trajectories to successful outcomes in less time, at less overall cost, and with less encountered risk has been well articulated in the literature. In partnership with industry and international collaborators, a TPL assessment methodology for grid-connected applications has been developed through the application of the systems engineering approach. Metrics under seven different categories have been developed, weighted based on their relative relevance, and combined to yield a composite score. The methodology has been implemented in a spreadsheet tool plus a web application specifically aimed at assessing early stage (TRL 1-3) concepts. The target use cases are (a) technology developers improving their design, to find fatal flaws early, to get feedback on current design, to identify areas of improvement that will yield the highest return on investment, (b) reviewers assessing technologies in competitions or for making funding decisions, (c) investor or project developer doing due diligence, (d) policy makers landscaping the technology domain for formulating R&D strategy. The methodology and the tools are undergoing continuous improvement based on the experience and lessons learnt from applying it to internal and external marine energy technology development projects. The methodology is also being adapted for assessing WECs servicing markets outside the continental grid - broadly categorized as Powering the Blue Economy (PBE) applications. Such applications have vastly different functional requirements entailing a modification of the methodology to account for their higher risk tolerance, reduced price sensitivities, lower power needs, different permitting protocols, etc. This paper presents the latest status of the TPL assessment methodology and tools, describes its adaptation to select PBE markets, and explores its extension to other domains where it could provide a comprehensive and holistic measure of a nascent or disruptive technology's technoeconomic performance potential.

metrics↗

Developing Technology Performance Level Assessments for Early-Stage Wave Energy Converter Technologies

The advantage of using Technology Performance Level (TPL) in conjunction with Technology Readiness Level (TRL) assessments in guiding technology development trajectories to successful outcomes in less time, at less overall cost, and with less encountered risk has been well articulated in the literature. In partnership with industry and international collaborators, a TPL assessment methodology for grid-connected applications has been developed through the application of the systems engineering approach. Metrics under seven different categories have been developed, weighted based on their relative relevance, and combined to yield a composite score. The methodology has been implemented in a spreadsheet tool plus a web application specifically aimed at assessing early stage (TRL 1-3) concepts. The target use cases are (a) technology developers improving their design, to find fatal flaws early, to get feedback on current design, to identify areas of improvement that will yield the highest return on investment, (b) reviewers assessing technologies in competitions or for making funding decisions, (c) investor or project developer doing due diligence, (d) policy makers landscaping the technology domain for formulating R&D strategy. The methodology and the tools are undergoing continuous improvement based on the experience and lessons learnt from applying it to internal and external marine energy technology development projects. The methodology is also being adapted for assessing WECs servicing markets outside the continental grid - broadly categorized as Powering the Blue Economy (PBE) applications. Such applications have vastly different functional requirements entailing a modification of the methodology to account for their higher risk tolerance, reduced price sensitivities, lower power needs, different permitting protocols, etc. This paper presents the latest status of the TPL assessment methodology and tools, describes its adaptation to select PBE markets, and explores its extension to other domains where it could provide a comprehensive and holistic measure of a nascent or disruptive technology's technoeconomic performance potential.

metrics↗

A Novel Design for Switchable Grid-Following and Grid-Forming Control

This paper presents the design of a novel grid- forming (GFM) control structure adapted from a typical grid- following (GFL) control structure with minimal edits, thereby enabling a switchable control structure for voltage sourced converters (VSCs) to operate in either GFL or GFM mode by simply switching a flag manually. The VSC is shown to be able to operate in the GFL control mode synchronizing to the main grid through a phase-locked-loop (PLL) and operate as a GFM controller with power-based synchronization for both grid-connected and islanded conditions. To guarantee smooth operation, the control schemes and the mode switching logic have been carefully designed and examined via a series of experiments. Here, the experiment results show that the switchable control structure can fulfill the desired control and operation functions and enable smooth transition between control modes.

14 SOLAR ENERGY↗

Net Metering Policy Development and Distributed Solar Generation in Minnesota: Overview of Trends in Nationwide Policy Development and Implications of Increasing the Eligible System Size Cap

The goal of the Minnesota net metering policy is to give the maximum possible encouragement to distributed generation assets, especially solar electric systems (MN 2008). However, according to a published set of best practices (NNEC 2008) that prioritize the maximum development of solar markets within states, the Minnesota policy does not incorporate many of the important best practices that may help other states transform their solar energy markets and increase the amount of grid-connected distributed solar generation assets. Reasons cited include the low system size limit of 40kW (the best practices document recommends a 2 MW limit) and a lack of language protecting generators from additional utility fees. This study was conducted to compare Minnesota's policies to national best practices. It provides an overview of the current Minnesota policy in the context of these best practices and other jurisdictions' net metering policies, as well as a qualitative assessment of the impacts of raising the system size cap within the policy based on the experiences of other states.

14 SOLAR ENERGY↗

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗

Distributed Photovoltaic Economic Impact Analysis in Indonesia

Like other countries in the region, the Government of Indonesia aims to increase its use renewable energy in the near term from various technologies, including grid-connected distributed photovoltaics (DPV). While little DPV has been installed to date, the policy landscape has been shifting over the past few years with recent pronouncements from the state-run utility Perusahaan Listrik Negara (PLN) and the Ministry of Energy and Mines (MEMR) that have begun to provide a more supportive policy framework for the deployment of DPV. Nonetheless, many questions remain as to how DPV impacts customers, the utility, and the economy as a whole. This report presents a holistic view of DPV economic impacts in the Java-Bali region of Indonesia by assessing customer economic impacts, utility revenue impacts, and jobs and economic development impacts.

14 SOLAR ENERGY↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network Reduction Algorithm for Developing Distribution Feeders for Real-Time Simulators

As advanced grid-support functions (AGF) become more widely used in grid-connected photovoltaic (PV) inverters, utilities are increasingly interested in their impacts when implemented in the field. These effects can be understood by modeling feeders in real-time simulators and test PV inverters using power hardware-in-the-loop (PHIL) techniques. This paper presents a novel feeder model reduction algorithm using a ruin & reconstruct methodology that enables large feeders to be solved and operated on real-time computing platforms. Two Hawaiian Electric feeder models in Synergi Electric's load flow software were converted to reduced order models in OpenDSS, and subsequently implemented in the OPAL-RT real-time digital testing platform. Smart PV inverters were added to the realtime model with AGF responses modeled after characterizing commercially available hardware inverters. Finally, hardware inverters were tested in conjunction with the real-time model using PHIL techniques so that the effects of AGFs on the feeders could be analyzed.

14 SOLAR ENERGY↗

Network Reduction Algorithm for Developing Distribution Feeders for Real-Time Simulators: Preprint

As advanced grid-support functions (AGF) become more widely used in grid-connected photovoltaic (PV) inverters, utilities are increasingly interested in their impacts when implemented in the field. These effects can be understood by modeling feeders in real-time systems and testing PV inverters using power hardware-in-the-loop (PHIL) techniques. This paper presents a novel feeder model reduction algorithm using a Monte Carlo method that enables large feeders to be solved and operated on real-time computing platforms. Two Hawaiian Electric feeder models in Synergi Electric's load flow software were converted to reduced order models in OpenDSS, and subsequently implemented in the OPAL-RT real-time digital testing platform. Smart PV inverters were added to the real-time model with AGF responses modeled after characterizing commercially available hardware inverters. Finally, hardware inverters were tested in conjunction with the real-time model using PHIL techniques so that the effects of AGFs on the choice feeders could be analyzed.

14 SOLAR ENERGY↗

Electricity Produced from Photovoltaic Systems in Apartment Buildings and Self-Consumption: Comparison of the Situation in Various IEA PVPS Countries

Over the last two decades, grid-connected solar photovoltaic systems have increased from a niche market to one of the leading power generation capacity additions annually. In 2018 the total installed photovoltaic electricity generation capacity exceeded 500 GW. Another doubling is forecasted until the early 2020s. Therefore, the further development is coupled with the question at what prices solar photovoltaic electricity can be provided and delivered to the customers. The installation of PV systems for self-consumption is already now an interesting option for many people but in general limited to those who have access to a rooftop they own or can use. A new envelopment to enable residents of multi apartment buildings to commonly use electricity generated by a PV system (collective self-consumption) is a relatively new development and is still facing a lot of administrative and regulatory challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗