Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT BALANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Amphiphilic nanopores that condense undersaturated water vapor and exude water droplets

Condensation of water vapor in confined geometries, known as capillary condensation, is a fundamental phenomenon with far-reaching implications. While hydrophilic pores enable liquid formation from undersaturated vapor without energy input, the condensate typically remains confined, limiting practical utility. Here, we explore the use of amphiphilic nanoporous polymer-infiltrated nanoparticle films that condense and release liquid water under isothermal and undersaturated conditions. By tuning the polymer fraction and nanoparticle size, we optimize condensation and droplet formation. As vapor pressure increases, voids fill with condensate, which subsequently exudes onto the surface as microscopic droplets. This behavior, enabled by a balance of polymer hydrophobicity and capillarity, reveals how amphiphilic nanostructures can drive accessible water collection. Our findings provide design insights for materials supporting energy-efficient water harvesting and heat management without external input.

Science & Technology - Other Topics↗

Chapter 11: Renewable Microgrids as a Foundation of the Future Sustainable Electrical Energy System

Renewable microgrids are an integral part of the future sustainable energy system. This chapter focuses on the role of renewable energy-based microgrids in the electricity system transformation. It is seen as a foundation that complements large-scale generation plants and high-voltage transmission lines by providing additional flexibility and resilience. This flexibility and resilience are crucial for balancing the energy system and ensuring its long-term sustainability, given the changing supply and demand patterns due to rooftop solar photovoltaics (PV), battery storage, electric mobility, and heat pumps. It is also an opportunity for residential and commercial consumers to become active participants in the energy market. Innovation, new technologies and business models will act as the key enabler for this transformation. The regulatory restructuring of the energy market will be crucial for successful integration of prosumers and aggregated energy communities. The chapter presents the vision of a sustainable, decentralized, and digitized energy future including market potential, most innovative case study projects and start-up companies, and the shifts needed in the regulatory landscape.

battery storage↗

An Enhanced Safeguards Approach for Accelerator Driven Systems utilized to Close the Fuel Cycle

Further to our previous safeguards approach for Accelerator Driven Systems, which focused on estimates of fissile material production using relevant proton accelerator systems and corresponding safeguards needs for fuel storage, the subcritical reactor, and spent fuel storage material balances areas, this report is more expansive and considers utilization of ADS for either burning of transuranics or breeding of fissile materials. We find that the recycled fuels likely intended for ADS will be thermally and radioactively hot to such a degree that it is likely reprocessing and fuel fabrication will have to be co - located with the ADS reactor facility to avoid impractical hot fuel transportation issues. As such, we consider in detail the full ADS system to include material balance areas for spent fuel receiving, reprocessing, storage & cooling, fuel fabrication, subcritical reactor area, and waste storage & handling. Furthermore, aqueous - based separation methods like PUREX cannot tolerate the intense heat of the ADS fuels, so pyroprocessing will likely be required. With these considerations, we developed an Enhanced Safeguards Approach for ADS beyond the work done in our first report, and conclude that significant diagnostic development is needed , a nd provide safeguards recommendations. We have also included an appendix regarding some country programs, in particular the Chinese ADANES burner/breeder program a nd the Indian thorium - based breeder program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Numerical Investigation of High Delta T Sensible Storage Integrated CO2 Heat Pump: Preprint

To assist building heating electrification, this paper numerically investigates a load flexible heat pump system for commercial buildings. The system consists of a CO2 vapor compression cycle, a sensible thermal storage tank, and an air handling unit. The thermal storage medium is inexpensive, non-toxic and stable anti-freeze solution (30% potassium acetate). The air handing unit has an indoor coil and a ventilation coil. The system can be used to manage building electric load. During peak hours, the heat pump is off and the hot solution water is discharged from the tank to heat up the indoor air and ventilation air. During the hour of charge, the heat pump delivers hot solution water to the tank and to the air. The tank can also stand by while the heat pump provides space heating directly. We selected a medium sized office building located in Minnesota as the representative building and used EnergyPlus to obtain its 24 hour load data. We designed three storage tank volumes assuming 50 degrees C, 65 degrees C and 80 degrees C tank temperatures to independently provide the building load for 4 hours in the morning. The higher the tank temperature, the smaller the required volume, and thus higher energy density. The effective energy density is 78 with an 80 degrees C tank, and 40 kWhth/m3 with 50 degrees C. We simulated the tank integrated heat pump performance subjected to the 24-hour building load profile and ambient data. The baseline is the same system without storage tank. There was a trade-off between the storage energy density and the charging COP. The charge hour COP was 2.77 to charge the tank to 80 degrees C, and 3.01 to 50 degrees C. The proposed system could shift building load from the peak hours (8:00 - 12:00) to off-business hour (23:00 - 7:00+1). It eliminated 100% compressor electricity use during the peak hours, and avoided a peak electric power of 34 kW. The 65 degrees C tank saved 9.5 kWhe (4%) considering all day operation, which was the best balance between energy density and the system operation efficiency among the three options.

CO2 heat pump↗

Fuel cells for single-aisle regional aircraft: System configuration, performance and cost

A hydrogen fuel cell propelled electric aircraft can compete with incumbent turbofan technologies for single-aisle regional aircraft by coupling design of stack, air handling, thermal management, propulsion, and airframe to optimize performance. The stack operates at 95°C to facilitate heat rejection during take-off and below 75°C during cruise to extend lifetime and is oversized to satisfy power requirements at end of life. A multi-stage turbocompressor with a compression ratio >10 is selected to reach high stack power density at 11,300-m cruise altitude. The propulsion system is configured to accommodate air handling within the core duct, an inclined heat exchanger in the outer duct to limit the nacelle size, and variable area nozzles to independently control mass flows through the core and bypass ducts. The airframe is modified for maximum lift coefficient and longer balanced field length for dramatically reduced thrust during take-off, and the fuselage is stretched by 20% to store liquid hydrogen (LH 2 ). Modularization of power systems promotes safety in one engine inoperative scenarios and allows reaching specific power metrics for stack, balance-of-plant and fuel cell system (FCS), necessary for acceptable take-off weight. In conclusion, cost parity requires increase in FCS lifetime, LH 2 cost reduction, and improved FCS specific power.

Catalyst durability↗

Investigating the Impacts of Daytime Boundary Layer Clouds on Surface Energy Fluxes and Boundary Layer Structure During CHEESEHEAD19

Studies of land-atmosphere interactions under a clear sky and low cumulus cloud conditions are common from long-term observatories like at the southern great plains. How well the relationships and responses of surface radiative and turbulent heat fluxes determined from these investigations hold for more heterogeneous surfaces in other climate regimes, however, is uncertain. In this study, detailed observations of the surface energy budget and daytime boundary layer properties are analyzed using measurements from the Chequamegon Heterogenous Ecosystem Energy-Balance Study Enabled by a High-Density Extensive Array of Detectors 2019 (CHEESEHEAD19) field campaign, July-October 2019, across a heterogeneous forested landscape of northern Wisconsin. A cloud regime framework is employed to classify consecutive periods of clear skies from lower atmosphere stratiform and cumulus clouds. A seasonal transition from low cumulus to low stratiform periods occurred, together with a diurnal pattern in cloudy or clear sky period dominance. Radiative forcing was highly dependent on sky conditions, leading to changes in the redistribution efficiency of radiative energy by the surface turbulent heat fluxes. During CHEESEHEAD19, small Bowen ratios dominated with daytime latent heat fluxes three times as large as sensible heat fluxes for all sky conditions studied; the forested region, therefore, falls within an energy-limited regime. The depth of the daytime mixed layer depended upon the sky condition and thermodynamic setting; deeper mixed layers occurred during periods of low cumulus and not clear skies. Profiles of vertical velocity were found to have enhanced variance under low cumulus compared to clear sky periods, suggesting potential for cloud feedbacks on boundary layer structure and surface energy fluxes.

54 ENVIRONMENTAL SCIENCES↗

Experimental warming and drying increase older carbon contributions to soil respiration in lowland tropical forests

Tropical forests account for over 50% of the global terrestrial carbon sink, but climate change threatens to alter the carbon balance of these ecosystems. We show that warming and drying of tropical forest soils may increase soil carbon vulnerability, by increasing degradation of older carbon. In situ whole-profile heating by 4 °C and 50% throughfall exclusion each increased the average radiocarbon age of soil CO 2 efflux by ~2–3 years, but the mechanisms underlying this shift differed. Warming accelerated decomposition of older carbon as increased CO 2 emissions depleted newer carbon. Drying suppressed decomposition of newer carbon inputs and decreased soil CO 2 emissions, thereby increasing contributions of older carbon to CO 2 efflux. These findings imply that both warming and drying, by accelerating the loss of older soil carbon or reducing the incorporation of fresh carbon inputs, will exacerbate soil carbon losses and negatively impact carbon storage in tropical forests under climate change.

54 ENVIRONMENTAL SCIENCES↗

Simulating dust grain-radiation coupling on a moving mesh

ABSTRACT We present a model for the interaction between dust and radiation fields in the radiation hydrodynamic code arepo-rt, which solves the moment-based radiative transfer equations on an unstructured moving mesh. Dust is directly treated using live simulation particles, each of which represent a population of grains that are coupled to hydrodynamic motion through a drag force. We introduce methods to calculate radiation pressure on and photon absorption by dust grains. By including a direct treatment of dust, we are able to calculate dust opacities and update radiation fields self-consistently based on the local dust distribution. This hybrid scheme coupling dust particles to an unstructured mesh for radiation is validated using several test problems with known analytic solutions, including dust driven via spherically symmetric flux from a constant luminosity source and photon absorption from radiation incident on a thin layer of dust. Our methods are compatible with the multifrequency scheme in arepo-rt, which treats UV, optical photons as single scattered and IR photons as multi scattered. At IR wavelengths, we model heating of and thermal emission from dust. Dust and gas are not assumed to be in local thermodynamic equilibrium but transfer energy through collisional exchange. We estimate dust temperatures by balancing these dust-radiation and dust-gas energy exchange rates. This framework for coupling dust and radiation can be applied in future radiation hydrodynamic simulations of galaxy formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Pairing Correlations across the Superfluid Phase Transition in the Unitary Fermi Gas

In the two-component Fermi gas with a contact interaction, a pseudogap regime can exist at temperatures between the superfluid critical temperature $T_c$ and a temperature $T^\ast > T_c$. This regime is characterized by pairing correlations without superfluidity. However, in the unitary limit of infinite scattering length, the existence of this regime is still debated. To help address this, we have applied finite-temperature auxiliary-field quantum Monte Carlo (AFMC) methods to study the thermodynamics of the superfluid phase transition and signatures of the pseudogap in the spin-balanced homogeneous unitary Fermi gas. We present results at finite filling factor $\textit{ν}$ ≃ 0.06 for the condensate fraction, an energy-staggering pairing gap, the spin susceptibility, and the heat capacity, and compare them to experimental data when available. In contrast to previous AFMC simulations, our model space consists of the complete first Brillouin zone of the lattice, and our calculations are performed in the canonical ensemble of fixed particle number. The canonical ensemble AFMC framework enables the calculation of a model-independent gap, providing direct information on pairing correlations without the need for numerical analytic continuation. We use finite-size scaling to estimate $T_c$ at the corresponding filling factor. In this work, we find that the energy-staggering pairing gap vanishes above $T_c$, showing no pseudogap effects, and that the spin susceptibility shows a substantially reduced signature of a spin gap compared to previously reported AFMC simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-shade dryland agrivoltaic conditions enhanced carbon uptake and water-use efficiency in zucchini ( Cucurbita pepo )

Introduction: The increasing global demand for food and energy is intensifying land-use competition. Agrivoltaic systems are a multifunctional land-use approach that vertically integrates the production of agricultural crops and solar power on the same land area. Most food crops are adapted to full-sun conditions, and the physiological responses of these crops to the novel microclimate under solar panels remain poorly understood. We hypothesized that the microclimate beneath the high-density photovoltaic system would influence carbon uptake, water use, and yield outcomes of zucchini summer squash.Methods: We conducted a field experiment in a hot, semi-arid climate on zucchini (Cucurbita pepo). Plants were grown under an agrivoltaic system with a 75% ground cover ratio (GCR) and in a full-sun control plot, each with two irrigation regimes (100 and 50%). We measured leaf-level photosynthesis, microclimate variables, and fruit yield at plant maturity and throughout the growing season.Results: The agrivoltaic array reduced photosynthetically active radiation (PAR) by ~79%, resulting in a cooler (−1.1 °C), more humid environment with higher soil moisture. These microclimatic conditions enhanced midday photosynthesis and daily cumulative carbon uptake. However, fruit yield was consistently lower under the panels, indicating a shift in carbon allocation toward vegetative growth. Photosynthesis was primarily driven by PAR across treatments, while soil moisture significantly influenced photosynthesis only in the control plots, suggesting water limitation was alleviated under the panels.Discussion: These findings highlight a trade-off between improved physiological performance and reduced yield under high-density agrivoltaics. While the system buffered heat and drought stress and improved overall plant function, excessive shade reduced reproductive output. Optimizing panel density or selecting crops cultivated for non-fruit yields will be essential for balancing food production and energy generation in dryland agrivoltaic settings.

14 SOLAR ENERGY↗

A buffering heat exchanger/thermal energy storage system for desalination applications

A buffering heat exchanger/thermal energy storage (BHXTES) system was designed using a fast-response phase-change material/graphite foam (PCM/GF) medium for desalination and potentially other industrial applications. Unlike a store-now-and-use-later TES system, this study focused on developing a dynamically balanced, continuously used, system that optimized three functions. A lab-scale prototype was designed and fabricated with a PureTemp 151/GF storage medium. The experimental data showed excellent thermal performance repeatability indicating minimal effects of PCM expansion and contraction on the GF as well as negligible PCM redistribution effects. The experimental data also served as a validation of the numerical model of the BHXTES system, after which optimization of the BHXTES system was conducted through numerical simulations for both PureTemp 151/GF and solar salt/GF as the storage medium. The results show that, with a Therminol 55 heat transfer fluid, continuous operation of the system can be realized with a solar energy source through cycles of 8-h changing for desalination and energy storage with the supplied heat followed by 16-h discharging for desalination with the stored energy. As a result, the working fluid outlet temperatures are generally in the ranges of approximately 128–160 °C for a PureTemp 151/GF medium and 198–220 °C for a solar salt/GF medium.

Buffering↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗

Closure of Earth’s Global Seasonal Cycle of Energy Storage

Abstract The global seasonal cycle of energy in Earth’s climate system is quantified using observations and reanalyses. After removing long-term trends, net energy entering and exiting the climate system at the top of the atmosphere (TOA) should agree with the sum of energy entering and exiting the ocean, atmosphere, land, and ice over the course of an average year. Achieving such a balanced budget with observations has been challenging. Disagreements have been attributed previously to sparse observations in the high-latitude oceans. However, limiting the local vertical integration of new global ocean heat content estimates to the depth to which seasonal heat energy is stored, rather than integrating to 2000 m everywhere as done previously, allows closure of the global seasonal energy budget within statistical uncertainties. The seasonal cycle of energy storage is largest in the ocean, peaking in April because ocean area is largest in the Southern Hemisphere and the ocean’s thermal inertia causes a lag with respect to the austral summer solstice. Seasonal cycles in energy storage in the atmosphere and land are smaller, but peak in July and September, respectively, because there is more land in the Northern Hemisphere, and the land has more thermal inertia than the atmosphere. Global seasonal energy storage by ice is small, so the atmosphere and land partially offset ocean energy storage in the global integral, with their sum matching time-integrated net global TOA energy fluxes over the seasonal cycle within uncertainties, and both peaking in April.

54 ENVIRONMENTAL SCIENCES↗

TRANSP integrated modeling code for interpretive and predictive analysis of tokamak plasmas

This paper provides a comprehensive review of the TRANSP code, a sophisticated tool for interpretive and predictive analysis of tokamak plasmas, detailing its major capabilities and features. It describes the equations for particle, power, and momentum balance analysis, as well as the poloidal field diffusion equations. The paper outlines the spatial and time grids used in TRANSP and details the equilibrium assumptions and solvers. Various models for heating and current drive and radiation, including updates to the NUBEAM model, are discussed. The handling of large-scale events such as sawtooth crashes and pellet injections is examined, along with the predictive capabilities for advancing plasma profiles. The integration of TRANSP with the ITER Integrated Modeling and Analysis Suite (IMAS) is highlighted, demonstrating enhanced data access and analysis capabilities. Additionally, the paper discusses best practices and continuous integration techniques to enhance TRANSP's robustness. The suite of TRANSP tools, designed for efficient data analysis and simulation, further supports the optimization of tokamak operations and coupling with other tokamak codes. Continuous development and support ensure that TRANSP remains a major code for the analysis of experimental data for controlled thermonuclear fusion, maintaining its critical role in supporting the optimization of tokamak operations and advancing fusion research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and Optimization of a Rotating Packed Bed Contactor with a Tetraamine-Appended Metal−Organic Framework for CO 2 Capture

A potential contactor technology for sorbent-based CO 2 capture is the rotating packed bed that contains separate sections for continuous adsorption and desorption. A heat exchanger can be embedded to remove heat in the adsorption section and add heat in the desorption section. In this work, we develop a two-dimensional (2D) model of a rotating packed bed for use in CO 2 capture applications. Mass and energy balances for the model are developed based on a Ljungström-type air preheater, which accounts for the counter-current axial flow of gas phases in separate sections of the bed and the rotation of a solid sorbent, which cycles between adsorption and desorption sections. The sorbent used for this analysis is the tetraamine-appended metal−organic framework Mg 2 (dobpdc)(3−4− 3), chosen for its stability and affinity for CO 2 at low partial pressures, such as those from a natural gas power plant source. An optimization problem is solved that considers the trade-off between maximizing the productivity of the bed and minimizing energy consumption. Maximum productivity and minimum energy are found to be 8.53 kg/h/m 3 and 3.84 MJ/kg, respectively, when these objectives are optimized independently. It is observed that the flue gas pressure and bed rotational speed are the desired operating variables to vary for model-based design of experiments to reduce uncertainty in parameter estimation, as these two variables yielded the most information content based on the Fisher information matrix.

20 FOSSIL-FUELED POWER PLANTS↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Energy Storage: Cost models

Energy storage technologies offer a promising solution to electric grid stability issues associated with the integration of variable renewable generators. The capability to match the electrical power output to instantaneous fluctuations in grid demand is crucial to ensure continuity of service. Including energy storage capability in an integrated energy system (IES) can provide the flexibility needed to meet variable electric demand and reduce the load following demands place on the reactor. In this report, economic data collected for energy storage (ES) technologies are described to support the objective of assessing the profitability of ES integration within the IES framework. In particular, there is a growing interest in thermal energy storage (TES) given its unique capability for long-duration storage for improving electricity reliability at a low levelized cost. It is common practice to evaluate the total lifetime cost and profitability before commercializing new technologies. In this report we identify and examine the models needed to better understand the economics of thermal energy storage. We extend the TES cost model in RAVEN in the context of a balance of plant (BOP) that incorporates thermal storage. To focus the discussion, following a general overview of the most promising TES technologies, we consider a use case that involves a sensible heat, two-tank, molten-salt system. Structural and operational details are reported to identify the source of construction capital expenditure and operation and maintenance cost. A detailed description of the different cost items is provided as well as the cost scaling with different storage capacity and power ratings for capacity optimization purpose. In addition, the capital expenditure and the recurring cost of representative two-tank, molten salt coupled with concentrated solar plants are provided for readers’ reference. The ES use case is noteworthy as it is in the pilot stage of commercialization. We identify those areas that would benefit from an increased economic focus to obtain a more complete compilation of cost data. We also describe the thermal coupling issues that arise from integration of the two-tank molten salt thermal energy storage system with a BOP, which is the subject of our current research. Some components of costs will need to be evaluated through dedicated technoeconomic analysis in future modeling activities using modeling procedures proposed in this report. With the data presented and the procedures described in this report, sufficiently accurate models can be implemented for the solution of both the power dispatch and the capacity expansion problems within the RAVEN-based HYBRID framework.

25 ENERGY STORAGE↗

Power Generation Cycle with RELAP-7

Balance of plant of a High-Temperature gas-cooled Reactor – Pebble bed Module (HTR-PM) is modeled using RELAP-7. The model includes the primary helium loop where the heat produced by the core is transferred to a helical-coil steam generator and the secondary loop where super-heated steam is fed to a turbine to extract power. The steam is then condensed to subcooled water and pumped back into the steam generator. Results demonstrate that RELAP-7 has the capability to model different regimes encountered in two-phase flow with wall boiling, superheated steam, subcooled liquid and condensation. RELAP-7 also has the capability of modeling different fluids with their own specific models in a very flexible way, without any code change. This also demonstrates the capability of modeling the transfer of fission power into electrical power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗