Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Shape optimization of tibial prosthesis components

NASA technology and optimal design methodologies originally developed for the optimization of composite structures (engine blades) are adapted and applied to the optimization of orthopaedic knee implants. A method is developed enabling the shape tailoring of the tibial components of a total knee replacement implant for optimal interaction within the environment of the tibia. The shape of the implant components are optimized such that the stresses in the bone are favorably controlled to minimize bone degradation, to improve the mechanical integrity of the implant/interface/bone system, and to prevent failures of the implant components. A pilot tailoring system is developed and the feasibility of the concept is demonstrated and evaluated. The methodology and evolution of the existing aerospace technology from which this pilot optimization code was developed is also presented and discussed. Both symmetric and unsymmetric in-plane loading conditions are investigated. The results of the optimization process indicate a trend toward wider and tapered posts as well as thicker backing trays. Unique component geometries were obtained for the different load cases.

Saravanos, D. A.↗

Helium and neon in lunar ilmenites of different antiquities

Helium and neon were extracted from individual lunar ilmenite grains, approximately 100 micrometers in diameter, using a pulsed step-heating technique. Grains from lunar samples 71501 and 79035, believed to have been exposed to solar corpuscular radiation at greatly different times, were studied. The results found were consistent with the hypothesis that in addition to solar-wind-implanted gas, a second more deeply implanted component was present in both species of grains. Average isotopic ratios were determined giving equal weight to each of the particles. As found in depth studies employing chemical etching, both the He-3/He-4 and Ne-20/Ne-22 ratios were lower in the more deeply implanted gas than in the solar wind component. The He-3/He-4 ratio in the solar wind component of the more ancient grains was lower than that in the more recently exposed ones, whereas no difference was found for the more deeply embedded He. In the deeply embedded component of the ancient grains, the He-4/Ne-20 ratio was approx. 2x that found in the more recently exposed grains. In the shallowly implanted component, the ratio varied greatly from grain to grain, preventing comparison with the solar wind elemental composition.

Nier, A. O.↗

Diffusion of Na and K in the uppermost regolith of Mercury

We examine the conditions under which ions impacting the Hermean surface can act as a regional source of enhanced atmospheric column through ion implantation and subsequent release at the surface. At most latitudes, energetic (a few keV) Na or K ions which impact the nightside surface, are released quickly (well before noon) upon warming of the surface. We show that the relative sunrise/sunset difference produced by ion implantation is ((n)(sub SR) - (n)(sub SS)/(n)(sub Ave) = f, where f is the fraction of the photo-ions recycled, (n)(sub SR) is the average zenith column above the sunrise portion of the illuminated hemisphere, (n)(sub SS) is the average zenith column in the sunset portion, and (n)(sub Ave) is the average column over the sunlit disk. Thus, to produce a large sunrise/sunset difference via ion implantation and subsequent release requires efficient (close to total) recycling. We show that the most extensive set of available data reduced to Na column abundance does not show any sunrise enhancement. We argue that the K data do not permit an unambiguous interpretation in favor of sunrise/sunset differences. We further find that if an efficient surface loss process for the alkali is not operating after sunrise, the initial Na and K distribution will relax into the bulk of the solid. Preserved abundance gradients of Na and K in lunar glasses that the Arrhenius coefficients for impact glasses are likely more modest than those for laboratory glasses derived from rock by nonimpact processes, but the effect of the more modest diffusion rates is only to delay the efficient loss of Na by a few Earth days. We argue that implantation can lead to observable regional increases in the observed Na or K column densities only if it occurs at very high latitudes, where diffusion is slow. It is typically lower energy ions which impact at high latitude and these are both more numerous than the high energy ions and possess smaller average penetration depths; thus there are additional reasons to favor a high-latitude locus for any possible prompt return related increases in zenith column. We find that we cannot rule out sputtering as a source process, as the low-energy ions are efficient sputterers. Finally, we argue that the observed Na/K ratio in the atmopshere may be the expression of their different asymptotic rates of loss from the interiors of the regolith grains. If so, this allows us to fix the importance of sputtering and photon stimulated desorption relative to impact vaporization.

Killen, R. M.↗

Three Paradigms of Lunar Regolith Evolution

Integration of diverse datasets on the Moon may render some paradigms of lunar science either better-defended or vulnerable. We will consider three paradigms commonly used for understanding the processes of lunar regolith evolution in light of new and accumulated data. Our premise is that all data-sets should converge to a single interpretation if a concept or model is to be accepted as a paradigm. If a convergence is lacking, the paradigm needs fresh scrutiny. SteadyState: Lunar regolith evolution is currently understood in terms of comminution, agglutination, and replenishment as described by McKay and coworkers). Briefly, the model envisages continued micrometeoritic bombardment to comminute exposed soil particles to finer sizes while continued agglutination consumes finer sizes to produce larger constructional particles. Eventually, a balance between these two opposing processes achieves a steady state; soils at steady state maintain their mean grain size (M(sub z)). Episodic higher-energy impacts excavate fresh coarse material from below the soil cover, disturb the steady state, and restart the process to achieve a new steady state. It follows that the thickness of the regolith at any site would control the frequency of replenishment; indeed, the thickness of the regolith at Apollo landing sites was predicted by McKay et al. from the average M(sub z) of local soils. However, replenishment may come also from disintegrating boulders and cobbles at the lunar surface, and rates of comminution and agglutination may depend on the properties of target material. Regression between M(sub z) and I(sub s)/Fe(sup 0) (a measure of maturity or total surface exposure) of Apollo soils at different sites shows the following relations and estimated M(sub z) at a high maturity of I(sub s)/Fe(sup 0)= 100. It is possible that Apollo 12 and 15 sites have the thickest regolith and the Apollo 16 site has the thinnest. It is also possible that Apollo 12 and 15 basalts are comminuted faster than Apollo 16 highland rocks and Apollo 14 and 17 soils are products of mixed parentage. If a soil becomes continually finer as it matures until agglutination catches up, and if comminution is differential-dependent on the physical properties of the constituents, then the composition of the bulk soil has to match the composition of some "fulcrum" grain size fraction, say X Grain size fractions >X and <X will complement each other; their mass balance is the bulk soil. It appears that the 10-20-micron size fraction may be the fulcrum. In general, trace-element chemistry and IR reflectance spectra of this size fraction are closest to that of the bulk soil, regardless of maturity that is surprising. Disaggregated products of regolith breccias may also show similar relationships. If the 10-20 gm is the fulcrum (i.e., X as above) for many soil properties (e.g., major element composition, FMR, solar-wind-implanted elements), then this may be the ultimate mean grain size of lunar soils at steady state. However, different properties of soils may find steady states at different grain size fractions. The steady state of solar-wind-implanted elements, on the other hand, will climb up the grain-size scale as agglutinates transfer surface-correlated components into volume correlated components until a saturation level is reached or the rates of replenishment and implantation become equal. The same will be the case with vapor-deposited reduced metals as they too are incorporated inside constructional particles. Properties that are directly affected by soil-maturation processes will thus have different pathways of achieving steady states. Maturity, i.e., cumulative surface exposure, of lunar soils is best quantified by the amount of nanophase superparamagnetic Fe(sup 0) (np-Fe(sup 0)) normalized to Fe content (=I(sub s)/Fe(sup 0). The majority consensus (paradigm?) for the production of np-Fe(sup 0) is associated with the production of agglutinates. Because large doses of solar-wind H are implanted in all lunar soils upon exposure, any melting (e.g., during agglutinate production) triggers a chemical reduction of Fe-bearing minerals resulting in np-Fe(sup 0) production. The quantity of np-Fe(sup 0) is thus dependent on melting events, (i.e., exposure), and limited by the Fe content of the soil. All freshly produced np-Fe(sup 0) resides in agglutinitic glass, as new TEM images show. Apparently, the correction procedure developed by Lucey et al. to estimate the Fe content of the lunar surface from IR-reflectance spectra depends on accepting the above. However, the process of producing np-Fe(sup 0) may be physical rather than chemical. All np-Fe(sup 0) could be deposits from a vapor produced by micrometeoritic impact on lunar soils. If metal-O bonds in target phases are broken, O being "most volatile" will escape leaving an O-deficient vapor to facilitate the production of np-Fe(sup 0). If so, the quantity of np-Fe(sup 0) is dependent on the vaporizing events, (i.e., exposure), and limited by the efficiency of breaking metal-O bonds and the escape of 0. To the extent that strengths of metal-O bonds are dependent on the local crystal field, production of np-Fe(sup 0) may be limited by the mineral composition of target soils and not by their total Fe content. According to this model, vapor-deposited np-Fe(sup 0) should be found at any retentive sites on lunar soil grains. Indeed, TEM images show np-Fe(sup 0) on plagioclase and ilmenite. Incorporation of such pre-irradiated np-Fe(sup 0)-bearing grains into agglutinates may account for eventual increased emplacement of np-Fe(sup 0) in agglutinates. Such a paradigm shift in understanding the origin of np-Fe(sup 0) will raise questions ranging from the unquestionable use of Is/FeO as the universal maturity parameter of lunar soils to global elemental maps of the Moon from remote-sensing data. Additional information is contained in the original.

Basu, A.↗

Behavioral and Physiological Analyses of Parturition In Pregnant Rats: Insights Derived from Intrauterine Telemetry

During labor and birth, fetuses are exposed to considerable physical stimulation associated with labor contractions and expulsion from the womb These forces are important for the neonates' adaptation to tile extrauterine environment. To further our understanding of the relationship between labor and postpartum outcome, we developed a novel method for measuring intrauterine pressure (IUP) in freely-moving, late pregnant and parturient rats that enables us to make precise, reliable measures of the forces experienced by rat fetuses during parturition. A small (1.25 x 4 cm) telemetric blood pressure sensor was fitted within a fluid-filled balloon, similar in size to a full term rat fetus. On Gestational day (G) 19 of the rats' 22/23 day pregnancy, each dam was anesthetized and a balloon/sensor unit surgically implanted within the uterus following removal of two fetuses. Comparisons were made between sensor-implanted dams (IMPL) and a control conditions: 1) LAP-R, laparotomy with two fetuses removed or 2) LAP-NR, laparotomy with no fetuses removed. IUP signals were sampled at 10s intervals from the IMPL dams during labor and birth. Dams in all three conditions were videorecorded enabling us to analyze the effect of the implant on behavioral expressions of parturition. Contraction frequency, duration, pup-to-pup birth intervals and pup-oriented activities of the dams measured from one hour prior to the first pup birth until the birth of the third pup were unaffected by the sensor implant. Intrauterine telemetry of freely-moving dams offers significant advantages over conventional hardwired IUP measurement techniques. These findings establish and validate intrauterine telemetry as a reliable, non-invasive technique for quantifying pressures associated with parturition.

Villareal, J.↗

Compact Radiative Control Structures for Millimeter Astronomy

We have designed, fabricated, and tested compact radiative control structures, including antireflection coatings and resonant absorbers, for millimeter through submillimeter wave astronomy. The antireflection coatings consist of micromachined single crystal silicon dielectric sub-wavelength honeycombs. The effective dielectric constant of the structures is set by the honeycomb cell geometry. The resonant absorbers consist of pieces of solid single crystal silicon substrate and thin phosphorus implanted regions whose sheet resistance is tailored to maximize absorption by the structure. We present an implantation model that can be used to predict the ion energy and dose required for obtaining a target implant layer sheet resistance. A neutral density filter, a hybrid of a silicon dielectric honeycomb with an implanted region, has also been fabricated with this basic approach. These radiative control structures are scalable and compatible for use large focal plane detector arrays.

Brown, Ari D.↗

CMOS Imager Has Better Cross-Talk and Full-Well Performance

A complementary metal oxide/semiconductor (CMOS) image detector now undergoing development is designed to exhibit less cross-talk and greater full-well capacity than do prior CMOS image detectors of the same type. Imagers of the type in question are designed to operate from low-voltage power supplies and are fabricated by processes that yield device features having dimensions in the deep submicron range. Because of the use of low supply potentials, maximum internal electric fields and depletion widths are correspondingly limited. In turn, these limitations are responsible for increases in cross-talk and decreases in charge-handling capacities. Moreover, for small pixels, lateral depletion cannot be extended. These adverse effects are even more accentuated in a back-illuminated CMOS imager, in which photogenerated charge carriers must travel across the entire thickness of the device. The figure shows a partial cross section of the structure in the device layer of the present developmental CMOS imager. (In a practical imager, the device layer would sit atop either a heavily doped silicon substrate or a thin silicon oxide layer on a silicon substrate, not shown here.) The imager chip is divided into two areas: area C, which contains readout circuits and other electronic circuits; and area I, which contains the imaging (photodetector and photogenerated-charge-collecting) pixel structures. Areas C and I are electrically isolated from each other by means of a trench filled with silicon oxide. The electrical isolation between areas C and I makes it possible to apply different supply potentials to these areas, thereby enabling optimization of the supply potential and associated design features for each area. More specifically, metal oxide semiconductor field-effect transistors (MOSFETs) that are typically included in CMOS imagers now reside in area C and can remain unchanged from established designs and operated at supply potentials prescribed for those designs, while the dopings and the lower supply potentials in area I can be tailored to optimize imager performance. In area I, the device layer includes an n+ -doped silicon layer on which is grown an n-doped silicon layer. A p-doped silicon layer is grown on top of the n -doped layer. The total imaging device thickness is the sum of the thickness of the n+, n, and p layers. A pixel photodiode is formed between a surface n+ implant, a p implant underneath it, the aforementioned p layer, and the n and n+ layers. Adjacent to the diode is a gate for transferring photogenerated charges out of the photodiode and into a floating diffusion formed by an implanted p+ layer on an implanted n-doped region. Metal contact pads are added to the back-side for providing back-side bias.

Pain, Bedabrata↗

Laser Subdivision of the Genesis Concentrator Target Sample 60000

The Genesis Allocation Committee received a request for ~ 1 square centimeter of the diamond-like-carbon (DLC) concentrator target for the analysis of solar wind nitrogen isotopes. The target consists of a single crystal float zone (FZ) silicon substrate having a thickness on the order of 550 micrometers with a 1.5-3.0 micrometer-thick coating of DLC on the exposed surface. The solar wind is implanted shallowly in the front side DLC. The original target was a circular quadrant with a radius of 3.1 cm; however, the piece did not survive intact when the spacecraft suffered an anomalous landing upon returning to Earth on September 8, 2004. An estimated 75% of the DLC target was recovered in at least 18 fragments. The largest fragment, Genesis sample 60000, has been designated for this allocation and is the first sample to be subdivided using our laser scribing system Laser subdivision has associated risks including thermal diffusion of the implant if heating occurs and unintended breakage during cleavage. A careful detailed study and considerable subdividing practice using non-flight FZ diamond on silicon, DOS, wafers has considerably reduced the risk of unplanned breakage during the cleaving process. In addition, backside scribing reduces the risk of possible thermal excursions affecting the implanted solar wind, implanted shallowly in the front side DLC.

Lauer, Howard V., Jr.↗

Methods for Determining Blood Flow Through Intact Vessels of Experimental Animals Under Conditions of Gravitational Stress and in Extraterrestrial Space Capsules

Work during the initial six months of this program has proceeded along three lines: (1) technical development of blood flowmeter instrumentation: (2) surgical considerations related to special problems of chronic implantation of flowmeter probes: (3) study of the relationship between levels of blood flow and organ activity. Principal engineering effort has been focused on the fundamental phenomena operative in the flowmeter probe and on probe design. Two probes have been constructed and a third is nearing completion. A previously unrecognized source of zero drift has been discovered and corrected. has been designed, assembled, tested and successfully employed in work on the several probes. A significant innovation which has been introduced is the use of a transformer coupled input for suppression of unwanted common mode signals. New low noise transistor amplifiers with characteristics suitable for space vehicle packaging are being developed. Linearity of the present apparatus has been found to extend at least into the near turbulent flow region. Attention has been directed to the two vascular beds of physiologic interest that present particular problems with regard to chronic implantation of flowmeter probes, the myocardium and the liver. Surgical techniques have been perfected that will permit myocardial and liver blood flow measurement. Two groups of animals have successfully undergone surgery and await the implantation of probes. Studies of the relationship between organ blood flow and levels of physiologic activity have been initiated. The first organ system studied was the heart, For the first time autoregulatory mechanisms have been demonstrated within the myocardial vascular bed which rapidly and precisely maintain coronary blood flow at a level i n keeping with the magnitude of cardiac work, Following a summary statement of the status of the program, the work performed is described, A financial review of expenditures incurred and a proposal for future funding are appended,

Shaw, R. F.↗

Percutaneous connector device

A device is reported for facilitating the passage of electrical signals from an external source through the skin of a patient to internal portions of the body such as muscles and nerves. The connector device includes a bio-compatible shell having an enlarged disk shaped portion for being implanted below the skin of the patient. The shell has a first and second electrically conductive post carried therein upon which a plug can be readily connected and disconnected. A modified form of the invention utilizes a unipolar connector that is adapted to be plugged into a shell implanted below the skin of a patient. Both of the connector devices are designed to be separated when a predetermined force is applied. This prevents excessive force from being applied to the implanted bio-compatible shell.

Parsons, W. E.↗

An inductively powered telemetry system for temperature, EKG, and activity monitoring

An implant telemetry system for the simultaneous monitoring of temperature, activity, and EKG from small animals, such as rats, was designed with the feature that instead of a battery the system is energized by an inductive field. A 250 kHz resonant coil surrounds the cage (30 x 30 x 20 cm) and provides the approximately 100 microns of power required to operate the implant transmitter while allowing the animal unrestrained movement in the cage. The implant can also be battery operated if desired. RF transmission is in the 8-10 MHz band, which allows the use of a simple, essentially single IC chip, receiver.

Fryer, T. B.↗

Adaptation of ion beam technology to microfabrication of solid state devices and transducers

A number of areas were investigated to determine the potential uses of ion beam techniques in the construction of solid state devices and transducers and the packaging of implantable electronics for biomedical applications. The five areas investigated during the past year were: (1) diode-like devices fabricated on textured silicon; (2) a photolithographic technique for patterning ion beam sputtered PVC (polyvinyl chloride); (3) use of sputtered Teflon as a protective coating for implantable pressure sensors; (4) the sputtering of Macor to seal implantable hybrid circuits; and (5) the use of sputtered Teflon to immobilize enzymes.

Topich, J. A.↗

A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

Lund, G. F.↗

Sputtering - Its relationship to isotopic fractionation on the lunar surface

Silicon, oxygen, sulfur and, possibly, potassium show systematic enrichment of heavier isotopes with increasing soil maturity, probably as a result of solar-wind sputtering, but such a pattern is not exhibited by solar wind-implanted species. Apparently sputter-erosion is not penetrating to their implantation depth, about 200 A. This suggests that sputtering on the moon is being impeded by deposition of vapor condensate following meteoritic impact. Although neither secular variation in the isotopic composition at the source of regolith carbon, probably the solar wind, nor isotopic fractionation of carbon after implantation in the regolith can be ruled out, carbon isotope systematics currently yield no evidence in support of either process.

Kerridge, J. F.↗

An inductively powered telemetry system for temperature, EKG, and activity monitoring

An implant telemetry system for the simultaneous monitoring of temperature, activity, and EKG from small animals, such as rats, has recently been designed with the novel feature that instead of a battery the system is energized by an inductive field. A 250 kHz resonant coil surrounds the cage (30 x 30 x 20 cm) and provides the approximately 100 microwatt of power required to operate the implant transmitter while allowing the animal unrestrained movement in the cage. The implant can also be battery operated if desired. RF transmission is in the 8-10 MHz band, which allows the use of a simple, essentially single IC chip, receiver.

Fryer, T. B.↗

Study program to improve the open-circuit voltage of low resistivity single crystal silicon solar cells

The results of a 14 month program to improve the open circuit voltage of low resistivity silicon solar cells are described. The approach was based on ion implantation in 0.1- to 10.0-ohm-cm float-zone silicon. As a result of the contract effort, open circuit voltages as high as 645 mV (AMO 25 C) were attained by high dose phosphorus implantation followed by furnace annealing and simultaneous SiO2 growth. One key element was to investigate the effects of bandgap narrowing caused by high doping concentrations in the junction layer. Considerable effort was applied to optimization of implant parameters, selection of furnace annealing techniques, and utilization of pulsed electron beam annealing to minimize thermal process-induced defects in the completed solar cells.

Minnucci, J. A.↗

The automated array assembly task of the low-cost silicon solar array project, phase 2

Several specific processing steps as part of a total process sequence for manufacturing silicon solar cells were studied. Ion implantation was identified as the preferred process step for impurity doping. Unanalyzed beam ion implantation was shown to have major cost advantages over analyzed beam implantation. Further, high quality cells were fabricated using a high current unanalyzed beam. Mechanically masked plasma patterning of silicon nitride was shown to be capable of forming fine lines on silicon surfaces with spacings between mask and substrate as great as 250 micrometers. Extensive work was performed on advances in plated metallization. The need for the thick electroless palladium layer was eliminated. Further, copper was successfully utilized as a conductor layer utilizing nickel as a barrier to copper diffusion into the silicon. Plasma etching of silicon for texturing and saw damage removal was shown technically feasible but not cost effective compared to wet chemical etching techniques.

Coleman, M. G.↗

Heart rate, multiple body temperature, long-range and long-life telemetry system for free-ranging animals

The design details and rationale for a versatile, long-range, long-life telemetry data acquisition system for heart rates and body temperatures at multiple locations from free-ranging animals are presented. The design comprises an implantable transmitter for short to medium range transmission, a receiver retransmitter collar to be worn for long-range transmission, and a signal conditioner interface circuit to assist in signal discrimination and demodulation of receiver or tape-recorded audio outputs. Implanted electrodes are used to obtain an ECG, from which R-wave characteristics are selected to trigger a short RF pulse. Pulses carrying heart rate information are interrupted periodically by a series of pulse interval modulated RF pulses conveying temperature information sensed at desired locations by thermistors. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as radio frequency interference. The implanted transmitter may be used alone for medium and short-range tracking, or with a receiver-transmitter collar that employs commercial tracking equipment for transmissions of up to 12 km. A system prototype has been tested on a dog.

Lund, G. F.↗