Search NASA⌕ Search

SEARCH · Search NASA

Results for “ISAACS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A semi-empirical NO x model for LES in pulverized coal air-staged combustion

Numerical simulation of pulverized coal combustion with the large eddy simulation (LES) method can provides important instructions on the design optimization of boilers. Because of its huge computational cost, a simple but reliable NO x prediction model is required in LES. Through the air-staged combustion experiments of six kinds of coals which conducted in an electric heated down-fired furnace (DFF), the relationship between NO x reduction and CO+H 2 generation in the fuel-rich zone was identified. Based on this observation, a semi-empirical modeling strategy was proposed: instead of CHi which is difficult to calculate, the concentration of CO+H 2 is used to quantify NO homogeneous reduction. An integrated NO x prediction model was proposed and implemented into LES simulation. Here, the results proved the new model can accurately predict different NO x evolution characteristics under various conditions. Furthermore, the comparison indicated the LES method performs better on NO x prediction than the RANS method, especially in the area where the turbulent fluctuation is relatively stronger.

97 MATHEMATICS AND COMPUTING↗

Integrated geological, economic, and risk assessment of underground hydrogen storage

Underground hydrogen storage (UHS) is a promising option to buffer variable renewable power and support the hydrogen economy. Yet this technology is early-stage, and key uncertainties remain about how coupled processes such as geochemical and geomechanical impacts affect long-term storage security. In this paper, we seek to integrate the results from a large, multi-scale research program to quantify core feasibility metrics and situate these studies within ongoing efforts. Through this work, we evaluate hydrogen recoverability during storage by assessing diffusive losses, losses to geochemical interactions and their subsequent impact on geomechanical properties, and losses to residual saturation during injection and withdrawal. Molecular and laboratory studies show that lithologic heterogeneity, pore geometry, and mineral surface chemistry govern hydrogen–rock interactions, controlling loss pathways. High-pressure coreflooding is used to estimate relative permeabilities and measure parameters needed for reservoir-scale sensitivity analyses. These core-scale experiments found early hydrogen breakthrough at low saturations driven by capillary and viscous fingering, which limits pore-space utilization at early times, while repeated injection and withdrawal cycles improve deliverability over time. Technoeconomic factors and purity requirements for end uses are also considered as part of our comprehensive feasibility analysis. Finally, we underscore the importance of geophysical monitoring and tailored injection strategies to maintain integrity and efficiency. Together, these results provide a quantitative foundation for safe, scalable deployment of UHS and highlight priorities for future integrated studies.

08 HYDROGEN↗

Multi-omics of NET formation and correlations with CNDP1, PSPB, and L-cystine levels in severe and mild COVID-19 infections

We report that we performed a multi-omics analysis of an immunologically naïve SARS-CoV-2 clinical cohort to characterize overall changes in plasma among control (uninfected), mild, and severe infections. A comparison of healthy controls and patient samples showed activation of neutrophil degranulation pathways. Consistent with this observation, we characterized neutrophil extracellular trap (NET) complexes that were partially initiated in a subset of the mild infections (showing partially formed NETs) and fully-formed NETs in a subset of severe infections (containing multiple NET proteins in individual patient samples). As a potential mechanism to suppress NET formation, multiple redox enzymes were elevated in the mild and severe population. Analysis of metabolites from the same cohort showed a 24 and 60-fold elevation in plasma L-cystine, the oxidized form of cysteine and substrate of the powerful antioxidant glutathione in mild and severe patients, respectively. Unique to patients with mild infections, the carnosine dipeptidase modifying enzyme (CNDP1) was up-regulated. The strong protein and metabolite oxidation signatures suggest multiple compensatory pathways working to suppress both free radical and NET formation in SARS-CoV-2 infections.

60 APPLIED LIFE SCIENCES↗

Levelized Cost of CO 2 Captured Using Five Physical Solvents in Pre-combustion Applications

Aspen Plus v8.8 was used to perform techno-economic analysis (TEA) of a CO 2 capture process from a typical fuel gas stream in a 543-MW pre-combustion power plant using five different physical solvents (Selexol, PEGPDMS-1, NMP, [aPy][Tf 2 N] and [hmim][Tf 2 N]). The process included a countercurrent packed-bed absorber operating under high-pressure over a wide range of temperatures and three pressure-swing flash drums for solvent regeneration. Furthermore, two packings, Mellapak 250Y and IMTP50, were used and the Levelized costs of CO 2 captured (LCOC) were calculated. The simulation results indicated that using Mellapak 250Y exhibited lower LCOC values than those when using IMTP50 for the five solvents under all conditions used as it offered better mass transfer. The CO 2 capture process carried out at low temperatures showed lower LCOC values than those at higher temperatures due to the increased CO 2 solubility in the solvents at lower temperatures, requiring smaller absorber diameter and lower solvent circulation rates, which offset the cooling requirements. Comparing the lowest LCOC values for the five solvents, the hydrophobic PEGPDMS-1 solvent was the most promising one compared to the other four solvents, due to its lowest capital and operating costs and noncorrosive, which enabled using less expensive materials for the process equipment.

42 ENGINEERING↗

Experimental measurements of fuel and water crossover in an active DMFC

This work measured polarization curves as well as the high-frequency resistance of active direct methanol fuel cell (DMFC) operates at around 80 °C with active controls of temperature, methanol concentration, airflow rate, and relative humidity. The relative humidity of the air did not have noticeable impacts on the fuel cell unless the operating temperature was near the evaporation temperature of water (100 °C). The hydrophobic water management layer (WML) between the membrane electrode assembly (MEA) and cathode air channel increases the mass transfer resistance and improves the water retention in MEA. Adding a WML increased the peak power density, decreased the ohmic resistance, and improved the fuel efficiency of the fuel cell, especially when it operated near 100 °C. This study also quantitatively measured methanol and water crossover as well as the fuel efficiency at different operating currents. The fuel efficiency increased significantly with the increase of the current density. Using a hydrophobic fuel management layer (FML) between the anode fuel channel and MEA reduced the fuel and water crossover rates and increased the ohmic resistance due to the decrease of the water content of the Nafion membrane. The FML improved fuel efficiency by reducing the methanol crossover. The combination of the FML and WML enabled the steady operation of DMFC using highly concentrated methanol solutions (up to 75 wt%).

08 HYDROGEN↗

Microscopic ejecta measurements from hypervelocity impacts on aluminum and powdered regolith targets

Meteoroids and space debris pose a two-fold threat to spacecraft due to the risk of both mechanical damage from the impact and electrical damage from the impact-generated plasma, which produces electromagnetic emissions. Analysis of impact products, however, has the potential to provide useful information about planetary rings and small solar system bodies, such as asteroids and comets. Understanding the plasma dynamics and radiation mechanism is essential to addressing the impact threat and extracting science data from impacts. Charge attachment to condensed-phase debris may lead to a dusty plasma under certain conditions, so interpreting hypervelocity impacts requires knowledge of both the nature of the plasma and of the ejecta. We address the latter with measurements of the microscopic ejecta distribution produced by light gas gun impacts on solid aluminum and powdered regolith simulant targets. We examine both the size and shape of the ejecta using thin-film witness plates and find that the size distributions of microscopic ejecta follow power laws. Observations from the powdered regolith simulant match well with disruption experiments of solid basalt, while measurements from the aluminum impacts diverge from extrapolations based on studies of macroscopic debris. Analysis of the ejecta shape shows a transition from smooth to irregularly shaped ejecta at the material grain size, and the shape of debris may provide insight on the phase of the ejected material. Finally, based on our results, we predict a significant number of secondary impacts on plasma sensors due to ejecta, even at considerable distance from the target, supporting the hypothesis that charged dust affects plasma measurements in the ejecta curtain.

42 ENGINEERING↗

Effects of gas purity on backgrounds of collision reaction cell-equipped MC-ICP-MS

The advent of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) instruments equipped with collision reaction cells (CRCs) facilitates interference removal/mitigation via online gas phase separations. This approach has proven effective for high intensity ion beams measured on Faraday collectors; however, it has been observed that introduction of gas in the CRC can result in significant background signals relative to the more sensitive ion counters. These backgrounds hinder use of these instruments for low level concentration and isotopic ratio measurements when employing a reaction gas. Here, this work directly evaluates the effect of gas purity on backgrounds of CRC-MC-ICP-MS instruments. Introducing high-purity research grade O 2 (99.999%) into the CRC produces complex background spectra with intensities >10 4 cps observed at most masses across the measured mass range (7-300 m / z ). Some features of the observed spectra (i.e., positive mass defects) can be attributed to molecular compounds comprised of significant hydrogen. Additionally, some specific molecular species can be identified (i.e., MoO x H y + ) and appear to be derived from molybdenum rods comprising the CRC. Further purifying the gas reduces the intensity of these backgrounds by several orders of magnitude, to <10 2 cps in many cases, and reduces complexity of the resulting spectra. This reduction in background appears to be in part driven by removal of impurities (i.e., H 2 O) from the gas. This work demonstrates that additional purification of reaction gases prior to introduction into the CRC significantly reduces backgrounds detected, potentially expanding the utility of CRC-MC-ICP-MS for making low level measurements using inline gas phase ion separations.

Schlieder, Tyler D. [Pacific Northwest National La↗

Finite element modeling of rock cutting and its fragmentation process

Rock cutting is a challenging problem from a modeling perspective. The challenges come from the complexity of the physics from the tool-rock interaction to the fracture process and propagation of the quasibrittle rocks. This study was aimed at developing a finite element procedure that was capable of providing reasonable estimates of cutting forces and, at the same time, capturing the essential characteristics of the fragmentation process. Published laboratory rock scratch tests were used as modeling targets since these tests encompass all essential characteristics of rock. Both shallow cuts and deep cuts from a rectangular cutter were analyzed first, and followed by modeling of shallow cuts from a disc cutter. It was concluded that rock cutting could be reasonably modeled by using a plasticity model, an element erosion scheme that remove an element when its energy release equals fracture energy, together with a proper selection of modeling parameters.

02 PETROLEUM↗

Mechanical specific energy versus depth of cut in rock cutting and drilling

The relationship between Mechanical Specific Energy (MSE) and the Rate of Penetration (ROP), or equivalently the depth of cut per revolution, provides an important measure for strategizing a drilling operation. This study explores how MSE evolves with depth of cut, and presents a concerted effort that encompasses analytical, computational and experimental approaches. A simple model for the relationship between MSE and cutting depth is first derived with consideration of the wear progression of a circular cutter. This is an extension of Detournay and Defourny's phenomenological cutting model. Wear is modeled as a flat contact area at the bottom of a cutter referred to as a wear flat, and that wear flat in the past is often considered to be fixed during cutting. But during a drilling operation by a full bit that consists of multiple circular cutters, the wear flat length may increase because of various wear mechanisms involved. The wear progression of cutters generally results in reduced efficiency with either increased MSE or decreased ROP. Also, an accurate estimate of removed rock volume is found important for the evaluation of MSE. The derived model is compared with experiment results from a single circular cutter, for cutting soft rock under ambient pressure with actual depth measured through a micrometer, and for cutting high strength rock under high pressure with actual cutting area measured by a confocal microscope. Lastly, the model is employed to interpret the evolution of MSE with depth of cut for a full drilling bit under confining pressure. The general form of equation of the developed model is found to describe well the experiment data and can be applied to interpret the drilling data for a full bit.

42 ENGINEERING↗

Liver Function After Irradiation Based on Computed Tomographic Portal Vein Perfusion Imaging

Purpose: To determine whether individual and regional liver sensitivity to radiation could be assessed by measuring liver perfusion during a course of treatment using dynamic contrast-enhanced computed tomography scanning. Methods and Materials: Patients with intrahepatic cancer undergoing conformal radiotherapy underwent dynamic contrast-enhanced computed tomography (to measure perfusion distribution) and an indocyanine extraction study (to measure liver function) before, during, and 1 month after treatment. We hoped to determine whether the residual functioning liver (i.e., those regions showing portal vein perfusion) could be used to predict overall liver function after irradiation. Results: Radiation doses from 45 to 84 Gy resulted in undetectable regional portal vein perfusion 1 month after treatment. The volume of each liver with undetectable portal vein perfusion ranged from 0 to 39% and depended both on the patient's sensitivity and on dose distribution. There was a significant correlation between indocyanine green clearance and the mean of the estimated portal vein perfusion in the functional liver parenchyma (p < 0.001). Conclusion: This study reveals substantial individual variability in the sensitivity of the liver to irradiation. In addition, these findings suggest that hepatic perfusion imaging may be a marker for liver function and has the potential to be a tool for individualizing therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy for Parotid Gland Tumors

Purpose: To investigate helical tomotherapy (HT) intensity-modulated radiotherapy (IMRT) as a postoperative treatment for parotid gland tumors. Methods and Materials: Helical tomotherapy plans were developed for 4 patients previously treated with segmental multileaf collimator (SMLC) IMRT. A primary planning target volume (PTV64) and two secondary PTVs (PTV60, PTV54) were defined. The clinical goals from the SMLC plans were applied as closely as possible to the HT planning. The SMLC plans included bolus, whereas HT plans did not. Results: In general, the HT plans showed better target coverage and target dose homogeneity. The minimum doses to the desired coverage volume were greater, on average, in the HT plans for all the targets. Minimum PTV doses were larger, on average, in the HT plans by 4.6 Gy (p = 0.03), 4.8 Gy (p = 0.06), and 4.9 Gy (p = 0.06) for PTV64, PTV60, and PTV54, respectively. Maximum PTV doses were smaller, on average, by 2.9 Gy (p = 0.23), 3.2 Gy (p = 0.02), and 3.6 Gy (p = 0.03) for PTV64, PTV60, and PTV54, respectively. Average dose homogeneity index was statistically smaller in the HT plans, and conformity index was larger for PTV64 in 3 patients. Tumor control probabilities were higher for 3 of the 4 patients. Sparing of normal structures was comparable for the two techniques. There were no significant differences between the normal tissue complication probabilities for the HT and SMLC plans. Conclusions: Helical tomotherapy treatment plans were comparable to or slightly better than SMLC plans. Helical tomotherapy is an effective alternative to SMLC IMRT for treatment of parotid tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evidence That MR Diffusion Tensor Imaging (Tractography) Predicts the Natural History of Regional Progression in Patients Irradiated Conformally for Primary Brain Tumors

Purpose: Stereotactic radiotherapy (SRT) is fast becoming the method of choice for treatment of nonsuperficial brain lesions. SRT treatment plans of malignant brain tumors typically incorporate a 20-mm isotropic margin to account for microscopic tumor spread; however, distant or progressive tumors occur outside this margin. Our hypothesis is that paths of elevated water diffusion may provide a preferred route for transport or migration of cancer cells. If our hypothesis is correct, then future SRT treatment volumes could be modified to provide elongated treatment margins along the paths of elevated water diffusion, thereby creating a biologically better treatment plan that may reduce the incidence of progression. Methods and Materials: Magnetic resonance diffusion tensor imaging (DTI) datasets were acquired on patient subjects before the appearance of >5 mm diameter progressive lesions or secondary tumors. DTI was performed using an echo-planar imaging sequence on a 1.5T clinical General Electric scanner with voxel dimensions of 0.98 x 0.98 x 6 mm. After SRT, patients were given repeated magnetic resonance imaging follow-ups at regular intervals to identify early tumor progression. When progressive disease was detected, DTIstudio and FMRIB Software Library software was used to compute paths of preferred water diffusion through the primary tumor site and the site of progression. Results: Our preliminary results on 14 patient datasets suggest a strong relationship between routes of elevated water diffusion from the primary tumor and the location of tumor progression. Conclusions: Further investigation is therefore warranted. Future work will employ more sophisticated fiber analysis in a prospective study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiotherapy for Lesions of the Spine and Paraspinal Regions

Purpose: To describe our experience and clinical strategy for stereotactic body radiotherapy (SBRT) of spinal lesions. Methods and Materials: Thirty-two patients with 33 spinal lesions underwent computed tomography-based simulation while free breathing. Gross/clinical target volumes included involved portions of the vertebral body and paravertebral/epidural tumor. Planning target volume (PTV) expansion was 6 mm axially and 3 mm radially; the cord was excluded from the PTV. Biologic equivalent dose was calculated using the linear quadratic model with {alpha}/{beta} = 3 Gy. Treatment was linear accelerator based with on-board imaging; dose was adjusted to maintain cord dose within tolerance. Survival, local control, pain, and neurologic status were monitored. Results: Twenty-one patients are alive at 1 year (median survival, 14 months). Median follow-up is 6 months for all patients (7 months for survivors). Mean previous radiotherapy dose to 22 patients was 35 Gy, and median interval was 17 months. Renal (31%), breast, and lung (19% each) were the most common histologic sites. Three SBRT fractions (range, one to four fractions) of 7 Gy (range, 5-16 Gy) were delivered. Median cord and target biologic equivalent doses were 70 Gy{sub 3} and 34.3 Gy{sub 10}, respectively. Thirteen patients reported complete and 17 patients reported partial pain relief at 1 month. There were four failures (mean, 5.8 months) with magnetic resonance imaging evidence of in-field progression. No dosimetric parameters predictive of failure were identified. No treatment-related toxicity was seen. Conclusions: Spinal SBRT is effective in the palliative/re-treatment setting. Volume expansion must ensure optimal PTV coverage while avoiding spinal cord toxicity. The long-term safety of spinal SBRT and the applicability of the linear-quadratic model in this setting remain to be determined, particularly the time-adjusted impact of prior radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gemcitabine-Based Combination Chemotherapy Followed by Radiation With Capecitabine as Adjuvant Therapy for Resected Pancreas Cancer

Purpose: To report outcomes for patients with resected pancreas cancer treated with an adjuvant regimen consisting of gemcitabine-based combination chemotherapy followed by capecitabine and radiation. Patients and Methods: We performed a retrospective review of a series of patients treated at a single institution with a common postoperative adjuvant program. Between January 2002 and August 2006, 43 resected pancreas cancer patients were offered treatment consisting of 4, 21-day cycles of gemcitabine 1 g/m{sup 2} intravenously over 30 min on Days 1 and 8, with either cisplatin 35 mg/m{sup 2} intravenously on Days 1 and 8 or capecitabine 1500 mg/m{sup 2} orally in divided doses on Days 1-14. After completion of combination chemotherapy, patients received a course of radiotherapy (54 Gy) with concurrent capecitabine (1330 mg/m{sup 2} orally in divided doses) day 1 to treatment completion. Results: Forty-one patients were treated. Median progression-free survival for the entire group was 21.7 months (95% confidence interval 13.9-34.5 months), and median overall survival was 45.9 months. In multivariate analysis a postoperative CA 19-9 level of >=180 U/mL predicted relapse and death. Toxicity was mild, with only two hospitalizations during adjuvant therapy. Conclusions: A postoperative adjuvant program using combination chemotherapy with gemcitabine and either cisplatin or capecitabine followed by radiotherapy with capecitabine is tolerable and efficacious and should be considered for Phase III testing in this group of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Week Neoadjuvant Intensity-Modulated Radiation Therapy With Concurrent Capecitabine and Oxaliplatin in Locally Advanced Rectal Cancer Patients: A Validation Phase II Trial

Purpose: To validate tolerance and pathological complete response rate (pCR) of a 4-week preoperative course of intensity-modulated radiation therapy (IMRT) with concurrent capecitabine and oxaliplatin (CAPOX) in patients with locally advanced rectal cancer. Methods and Materials: Patients with T3 to T4 and/or N+ rectal cancer received preoperative IMRT (47.5 Gy in 19 fractions) with concurrent capecitabine (825 mg/m{sup 2} b.i.d., Monday to Friday) and oxaliplatin (60 mg/m{sup 2} on Days 1, 8, and 15). Surgery was scheduled 4 to 6 weeks after the completion of chemoradiation. Primary end points were toxicity and pathological response rate. Local control (LC), disease-free survival (DFS), and overall survival (OS) were also analyzed. Results: A total of 100 patients were evaluated. Grade 1 to 2 proctitis was observed in 73 patients (73%). Grade 3 diarrhea occurred in 9% of the patients. Grade 3 proctitis in 18% of the first 50 patients led to reduction of the dose per fraction to 47.5 Gy in 20 treatments. The rate of Grade 3 proctitis decreased to 4% thereafter (odds ratio, 0.27). A total of 99 patients underwent surgery. A pCR was observed in 13% of the patients, major response (96-100% of histological response) in 48%, and pN downstaging in 78%. An R0 resection was performed in 97% of the patients. After a median follow-up of 55 months, the LC, DFS, and OS rates were 100%, 84%, and 87%, respectively. Conclusions: Preoperative CAPOX-IMRT therapy (47.5 Gy in 20 fractions) is feasible and safe, and produces major pathological responses in approximately 50% of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗