Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Sandia Simple Particle Tracking (Sandia SPT) v. 1.0

Sandia SPT is designed as software to accompany a book chapter being published a methods chapter which provides an introduction on how to label and track individual proteins. The Sandia Simple Particle Tracking code uses techniques common to the image processing community, where its value is that it facilitates implementing the methods described in the book chapter by providing the necessary open-source code. The code performs single particle spot detection (or segmentation and localization) followed by tracking (or connecting the detected particles into trajectories). The book chapter, which along with the headers in each file, constitutes the documentation for the code is: Anthony, S.M.; Carroll-Portillo, A.; Timlon, J.A., Dynamics and Interactions of Individual Proteins in the Membrane of Living Cells. In Anup K. Singh (Ed.) Single Cell Protein Analysis Methods in Molecular Biology. Springer

Anthony, Stephen M.↗

Responsive Image Inline Filter

RIIF is a contributed module for the Drupal php web application framework (drupal.org). It is written as a helper or sub-module of other code which is part of version 8 "core Drupal" and is intended to extend its functionality. It allows Drupal to resize images uploaded through the user-facing text editor within the Drupal GUI (a.k.a. "inline images") for various browser widths. This resizing is already done foe other images through the parent "Responsive Image" core module. This code extends that functionality to inline images.

Freeman, Ian↗

Inspection design using 2D phased array, TFM and cueMAP software

A simulation suite, cueMAP, has been developed to facilitate the design of inspection processes and sparse 2D array configurations. At the core of cueMAP is a Total Focusing Method (TFM) imaging algorithm that enables computer assisted design of ultrasonic inspection scenarios, including the design of bespoke array configurations to match the inspection criteria. This in-house developed TFM code allows for interactive evaluation of image quality indicators of ultrasonic imaging performance when utilizing a 2D phased array working in FMC/TFM mode. The cueMAP software uses a series of TFM images to build a map of resolution, contrast and sensitivity of imaging performance of a simulated reflector, swept across the inspection volume. The software takes into account probe properties, wedge or water standoff, and effects of specimen curvature. In the validation process of this new software package, two 2D arrays have been evaluated on 304n stainless steel samples, typical of the primary circuit in nuclear plants. Thick section samples have been inspected using a 1MHz 2D matrix array. Due to the processing efficiency of the software, the data collected from these array configurations has been used to investigate the influence sub-aperture operation on inspection performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Foundation Models for Zero-Shot Segmentation of Scientific Images without AI-Ready Data

Zero-shot and prompt-based models have excelled at visual reasoning tasks by leveraging large-scale natural image corpora, but they often fail on sparse and domain-specific scientific image data. We introduce Zenesis, a no-code interactive computer vision platform designed to reduce data readiness bottlenecks in scientific imaging workflows. Zenesis integrates lightweight multimodal adaptation for zero-shot inference on raw scientific data, human-in-the-loop refinement, and heuristic-based temporal enhancement. We validate our approach on Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) datasets of catalyst-loaded membranes. Zenesis outperforms baselines, achieving an average accuracy of 0.947, Intersection over Union (IoU) of 0.858, and Dice score of 0.923 on amorphous catalyst samples; and 0.987 accuracy, 0.857 IoU, and 0.923 Dice on crystalline samples. These results represent a significant performance gain over conventional methods such as Otsu thresholding and standalone models like the Segment Anything Model (SAM). Zenesis enables effective image segmentation in domains where annotated datasets are limited, offering a scalable solution for scientific discovery.

Mukherjee, Shubhabrata↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

ALMA CONTINUUM OBSERVATIONS OF A 30 Myr OLD GASEOUS DEBRIS DISK AROUND HD 21997

Circumstellar disks around stars older than 10 Myr are expected to be gas-poor. There are, however, two examples of old (30-40 Myr) debris-like disks containing a detectable amount of cold CO gas. Here we present Atacama Large Millimeter/Submillimeter Array (ALMA) and Herschel Space Observatory observations of one of these disks, around HD 21997, and study the distribution and origin of the dust and its connection to the gas. Our ALMA continuum images at 886 μm clearly resolve a broad ring of emission within a diameter of ∼4.''5, adding HD 21997 to the dozen debris disks resolved at (sub)millimeter wavelengths. Modeling the morphology of the ALMA image with a radiative transfer code suggests inner and outer radii of ∼55 and ∼150 AU, and a dust mass of 0.09 M {sub ⊕}. Our data and modeling hints at an extended cold outskirt of the ring. Comparison with the morphology of the CO gas in the disk reveals an inner dust-free hole where gas nevertheless can be detected. Based on dust grain lifetimes, we propose that the dust content of this gaseous disk is of secondary origin and is produced by planetesimals. Since the gas component is probably primordial, HD 21997 is one of the first known examples of a hybrid circumstellar disk, a thus-far little studied late phase of circumstellar disk evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep reinforcement learning of cell movement in the early stage of C.elegans embryogenesis

Motivation: Cell movement in the early phase of Caenorhabditis elegans development is regulated by a highly complex process in which a set of rules and connections are formulated at distinct scales. Previous efforts have demonstrated that agent-based, multi-scale modeling systems can integrate physical and biological rules and provide new avenues to study developmental systems. However, the application of these systems to model cell movement is still challenging and requires a comprehensive understanding of regulatory networks at the right scales. Recent developments in deep learning and reinforcement learning provide an unprecedented opportunity to explore cell movement using 3D time-lapse microscopy images. Results: We present a deep reinforcement learning approach within an agent-based modeling system to characterize cell movement in the embryonic development of C.elegans. Our modeling system captures the complexity of cell movement patterns in the embryo and overcomes the local optimization problem encountered by traditional rule-based, agent-based modeling that uses greedy algorithms. Here, we tested our model with two real developmental processes: the anterior movement of the Cpaaa cell via intercalation and the rearrangement of the superficial left-right asymmetry. In the first case, the model results suggested that Cpaaa’s intercalation is an active directional cell movement caused by the continuous effects from a longer distance (farther than the length of two adjacent cells), as opposed to a passive movement caused by neighbor cell movements. In the second case, a leader-follower mechanism well explained the collective cell movement pattern in the asymmetry rearrangement. These results showed that our approach to introduce deep reinforcement learning into agent-based modeling can test regulatory mechanisms by exploring cell migration paths in a reverse engineering perspective. Lastly, this model opens new doors to explore the large datasets generated by live imaging. Availability and implementation: Source code is available at https://github.com/zwang84/drl4cellmovement.

59 BASIC BIOLOGICAL SCIENCES↗

Introducing SpaceNet 9 - Cross-Modal Satellite Imagery Registration for Natural Disaster Responses

Computer vision algorithms are increasingly leveraged to accelerate geospatial analysis for disaster response and recovery. As the diversity of remote sensing imagery grows with optical, SAR, and other modalities, a perquisite for analytics is cross-modal image registration. There is a high potential to harness computer vision for this pre-processing requirement toward enabling downstream analytics such as heterogeneous change detection, automated feature extraction, and data fusion. Advancement in these areas has the potential to simplify data wrangling tasks and further accelerate disaster response timelines. The SpaceNet 9 challenge (launching in mid-2024) focuses on addressing the cross-modal image registration problem and demonstrating the utility of such modules on earthquake impacted scenarios. This paper describes the motivation for the SpaceNet 9 and provides a first overview of the dataset, the baseline algorithm, and implications for seeking cross-modal image registration in Earth observation. Code is available at https://github.com/SpaceNetChallenge/SpaceNet9.

Hansch, Ronny↗

Raman Microscopy Analysis of Wyoming CarbonSAFE Pilot Well Thin Sections for Mineralogy and Organic Matter Characterization

Scanning confocal Raman microspectroscopy (RMS) was used to analyze thin sections for inorganic mineral content and for evaluation of organic material (OM). Thin sections were selected from a stratigraphic test well core in the Powder River Basin, Wyoming under the Wyoming CarbonSAFE project. The well was analyzed with a variety of rock and fluid characterization techniques to determine the feasibility of a commercial-scale CO2 storage site. RMS complements other analyses, including traditional petrography, SEM, porosity and permeability, and XRD For this aspect of the study, RMS is especially important in the evaluation of OM in sealing lithologies. At prospective geologic CO2 storage sites, it is imperative to assess the unconventional oil and gas potential of seals to ensure that any future development would not compromise the integrity of the seals. Whole-slide mineralogical surveys were performed on thin sections from various shale and sandstone formations. Surveys were analyzed with Direct Classical Least Squares to identify and quantify minerals. The location and concentration of minerals was color-coded and overlaid on optical images for visualization of the distribution of minerals. Dense hyperspectral Raman mapping of OM was performed on five thin sections. Eleven spectral parameters diagnostic of organic type and thermal maturity were used to train a Partial Least Squares (PLS) calibration against a set of artificially matured samples spanning the pre- to mid-oil window. The PLS was applied to the study set and a post-mature set. Additionally, the PLS was applied to each point in hyperspectral maps for visualization of trends in maturity across sample sets and discrimination of organic matter types within a given map. In inorganic surveys on thin sections, a total of 14 unique inorganic minerals were identified in Raman spectra including quartz, dolomite, calcite, hematite and anhydrite. Shale thin sections tended to be dominated by organic material. OM was often observed mixed with inorganic minerals. Sand- and mudstones were dominated by inorganic minerals. The PLS extrapolated the post-mature set to reflectances >1.2%. The study set ranged from very immature to postmature in the median of map fit-peak parameters. However, point maturity maps indicate that matrix OM in all study samples is immature and that discreet organic particles selected for mapping, which may be inertinites, bias medians towards more-mature. The work demonstrates the capabilities of RMS to perform both whole-slide mineralogy and OM analysis with applications to formation evaluation in oil & gas, carbon sequestration and mining. Here, analysis of sealing formations in the well indicates high levels of immature organic matter that would not be a viable target for future oil production that could compromise the CO2 storage site. The work brings together diverse disciplines from geology and petrography to analytical chemistry, big data and microscopy.

Myers, Grant↗

Web-based Preprocessing and Visualization of 3D FIB Tomography Data for Nuclear Fuel Characterization

Three-dimensional (3D) focused ion beam (FIB) tomography enables reconstruction of internal nuclear fuel features that can't be fully evaluated through surface imaging alone. This capability supports characterization of fuel constituents and defects under thermal and irradiation conditions relevant to microreactor development. However, large tomography datasets can create data-handling, loading, and visualization challenges, especially when image-stack preparation and file conversion must be completed with separate tools. The Computational Ultraspatial Tomography Toolkit for High-Resolution Object Analysis Tools (CUTTRHOAT) is an open-source web application being developed to display FIB tomography datasets available through the Nuclear Research Data System (NRDS). The current alpha version requires prepared HDF5 datasets and has limited integrated data-preparation capabilities. This project improves CUTTHROAT by adding dataset-folder selection, automatic input detection, dataset scanning, missing-slice identification, blank-slice insertion, and image-stack-to-HDF5 conversion. Two applications will be compared: the baseline CUTTHROAT alpha workflow and the updated application containing the integrated data-handling and preprocessing functions. Evaluation will consider dataset detection accuracy, conversion success, loading time, rendering responsiveness, application stability, and user interaction. Preliminary results demonstrate successful loading of existing HDF5 files and converted image stacks, while testing also identified performance reductions caused by excessive blank-slice generation. The updated workflow reduces reliance on external preparation tools and supports more direct movement from image stacks to color-code 3D visualization. Future work includes refining missing-slice handling, integrating additional preprocessing functions, like a denoising feature, parsing TIFF metadata for automatic voxel scaling, and adding manual X, Y, and Z voxel-spacing inputs for PNG and JPEG.

36 - MATERIALS SCIENCE↗

Model for mapping settlements

A programmable media includes a graphical processing unit in communication with a memory element. The graphical processing unit is configured to detect one or more settlement regions from a high resolution remote sensed image based on the execution of programming code. The graphical processing unit identifies one or more settlements through the execution of the programming code that executes a multi-instance learning algorithm that models portions of the high resolution remote sensed image. The identification is based on spectral bands transmitted by a satellite and on selected designations of the image patches.

97 MATHEMATICS AND COMPUTING↗

A new compact, high sensitivity neutron imaging system

We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (10{sup 9}-10{sup 10} neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 Multiplication-Sign 10{sup 10}. The resolution of this image was 54 {mu}m and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a {sup 60}Co {gamma}-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Library based x-ray scatter correction for dedicated cone beam breast CT

Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal views. Conclusions: The library-based scatter correction does not require increase in radiation dose or hardware modifications, and it improves over the existing methods on implementation simplicity and computational efficiency. As demonstrated through patient studies, the authors’ approach is effective and stable, and is therefore clinically attractive for CBBCT imaging.

60 APPLIED LIFE SCIENCES↗

BlackCAT CubeSat: a soft x-ray sky monitor, transient finder, and burst detector for high-energy and multimessenger astophysics

Here we present the conceptual design of a wide field imager onboard a 6U class CubeSat platform for the study of GRB prompt and afterglow emission and detection of electromagnetic counterparts of gravitational waves in soft X-rays. The planned instrument configuration consists of an array of X-ray Hybrid CMOS detectors (HCD), chosen for their soft-X-ray response, flexible and rapid readout rate, and low power, which makes these detectors well suited for detecting bright transients on a CubeSat platform. The wide field imager is realized by a 2D coded mask. This paper will give an overview of the instrument design and the scientific requirements of the proposed mission.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID

Purpose: To investigate the dosimetric characteristics of Varian a-Si-500 electronic portal imaging device (EPID) operated in cine mode particularly considering linearity with delivered dose, dose rate, field size, phantom thickness, MLC speed and common IMRT fields. Methods: The EPID that attached to a Varian Clinac 21iX linear accelerator, was irradiated with 6 and 18 MV using 600 MU/min. Image acquisition is controlled by the IAS3 software, Trigger delay was 6 ms, BeamOnDelay and FrameStartDelay were zero. Different frame rates were utilized. Cine mode response was calculated using MATLAB as summation of mean pixel values in a region of interest of the acquired images. The performance of cine mode was compared to integrated mode and dose measurements in water using CC13 ionization chamber. Results: Figure1 illustrates that cine mode has nonlinear response for small MU, when delivering 10 MU was about 0.5 and 0.64 for 6 and 18 MV respectively. This is because the missing acquired images that were calculated around four images missing in each delivery. With the increase MU the response became linear and comparable with integrated mode and ionization chamber within 2%. Figure 2 shows that cine mode has comparable response with integrated mode and ionization chamber within 2% with changing dose rate for 10 MU delivered. This indicates that the dose rate change has no effect on nonlinearity of cine mode response. Except nonlinearity, cine mode is well matched to integrated mode response within 2% for field size, phantom thickness, MLC speed dependences. Conclusion: Cine mode has similar dosimetric characteristics to integrated mode with open and IMRT fields, and the main limitation with cine mode is missing images. Therefore, the calibration of EPID images with this mode should be run with large MU, and when IMRT verification field has low MU, the correction for missing images are required.

60 APPLIED LIFE SCIENCES↗

DECT-MULTRA: Dual-Energy CT Image Decomposition With Learned Mixed Material Models and Efficient Clustering

Dual-energy computed tomography (DECT) imaging plays an important role in advanced imaging applications due to its material decomposition capability. Image-domain decomposition operates directly on CT images using linear matrix inversion, but the decomposed material images can be severely degraded by noise and artifacts. This paper proposes a new method dubbed DECT-MULTRA for image-domain DECT material decomposition that combines conventional penalized weighted-least squares (PWLS) estimation with regularization based on a mixed union of learned transforms (MULTRA) model. Our proposed approach pre-learns a union of common-material sparsifying transforms from patches extracted from all the basis materials, and a union of cross-material sparsifying transforms from multi-material patches. The common-material transforms capture the common properties among different material images, while the cross-material transforms capture the cross-dependencies. The proposed PWLS formulation is optimized efficiently by alternating between an image update step and a sparse coding and clustering step, with both of these steps having closed-form solutions. The effectiveness of our method is validated with both XCAT phantom and clinical head data. The results demonstrate that our proposed method provides superior material image quality and decomposition accuracy compared to other competing methods.

47 OTHER INSTRUMENTATION↗

Transformations based on continuous piecewise-affine velocity fields

Here, we propose novel finite-dimensional spaces of well-behaved Rn → Rn transformations. The latter are obtained by (fast and highly-accurate) integration of continuous piecewise-affine velocity fields. The proposed method is simple yet highly expressive, effortlessly handles optional constraints (e.g., volume preservation and/or boundary conditions), and supports convenient modeling choices such as smoothing priors and coarse-to-fine analysis. Importantly, the proposed approach, partly due to its rapid likelihood evaluations and partly due to its other properties, facilitates tractable inference over rich transformation spaces, including using Markov-Chain Monte-Carlo methods. Its applications include, but are not limited to: monotonic regression (more generally, optimization over monotonic functions); modeling cumulative distribution functions or histograms; time-warping; image warping; image registration; real-time diffeomorphic image editing; data augmentation for image classifiers. Our GPU-based code is publicly available.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗