Search NASA⌕ Search

SEARCH · Search NASA

Results for “Inductively coupled plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Characterization of actinide abundances and isotopic compositions by HR-ICP-MS. Part 2: Results from actinide doping studies

Previously, we presented actinide isotopic and elemental data from fallout melt glass that was measured using high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). Direct comparison between these measurements and ‘gold standard’ data obtained by multi-collector ICP-MS showed broad overlap, indicating that HR-ICP-MS is a potentially valuable technique for producing actinide elemental and isotopic data on a relatively rapid timescale. To test the usefulness of this technique further, we doped varying amounts of uranium certified reference materials (CRMs) into a rhyolitic rock standard to establish the effects of uranium concentration and isotopic composition on the accuracy of uranium isotopic analyses by HR-ICP-MS. This also enabled us to quantify peak tailing effects from 238 U on the measurement of 239 Pu and 237 Np, which in turn allows us to constrain correction factors based on measured 237 Np/ 238 U and 239 Pu/ 238 U ratios. A second doping study involved the addition of a mixed actinide standard into three samples with different matrix compositions (termed soil, city, and seawater) to assess whether sample chemistry affects the accuracy and precision of these analyses. Results suggest that this is not the case. Systematic offsets were not observed in elemental or isotopic data derived from the three matrix samples. Results indicate that useful actinide isotopic data can be obtained from whole rock solutions by HR-ICP-MS. Our findings also have implications for solid sampling techniques such as laser ablation ICP-MS, which do not require sample dissolution.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Synthesis of Zeolites LiX and LiAgX

In this work, we produced approximately 50 grams of zeolite LiX and 50 grams of zeolite LiAgX from commercially available zeolite X. The production of the two specialized zeolite phases was accomplished via a series of ion exchange steps followed by washing, drying, and calcining to produce the final materials. The ion exchange was confirmed by several methods including inductively-coupled plasma emission spectroscopy of exchange solution aliquots, gravimetric analysis, energy dispersive x-ray spectroscopy, and X-ray diffraction. We synthesized approximately 115 grams of zeolite LiX in a large-scale production step after completing a proof-of-concept experiment demonstrating the methodology. The production of zeolite LiX from zeolite X yielded an ion exchange (Li + →Na + ) of approximately 82%. The production of zeolite LiAgX from the previously synthesized zeolite LiX was targeted to exchange approximately 20% of the Li + ions with Ag + ions. We first performed a proof-of-concept experiment demonstrating the reaction pathway and selectivity of the Ag + ion, and then performed a large-scale synthesis of zeolite LiAgX using approximately 50 grams of the zeolite LiX. Our final exchange percentage of silver into the zeolite LiX matrix was approximately 20.8%.

36 MATERIALS SCIENCE↗

Characterizing the Uncertainty of Measurement of Traceable Isotope Ratios with Bayesian Statistical Techniques

Analytical techniques such as multicollector—inductively coupled plasma—mass spectrometry (MC-ICP-MS) are routinely employed at SRNL, other National Laboratories, and in academia to determine the precise isotopic composition of diverse natural and anthropogenic samples (e.g., rocks and nuclear materials). Quantifying and reporting uncertainty in such analyses, while regularly performed, have a rigorous statistical foundation. The Guide to the Expression of Uncertainty in Measurement 4 (GUM) outlines conventional techniques used to assess such uncertainty. As the accessibility and speed of statistical computing increase, there is a need to modernize conventional techniques. For example, Supplement 1 to the 3rd to the GUM suggests the use of approximation methods as an updated approach to the GUM.

McLarty, Ellis C.↗

Synthesis and Functionalization of Coal Fly Ash-Derived Zeolites for Boron Removal From Wastewater

There are hundreds of both active and unused surface impoundments in the United States containing coal combustion residuals (CCRs) produced by coal-fired power plants which can leach toxic elements into surface and groundwater. Therefore, the development of efficient means for both the clean-up of surface impoundments and for deriving economically viable products from CCRs are urgent tasks for researchers. Herein, a microwave-assisted strategy is presented for converting a common coal combustion residual, coal fly ash (CFA), into zeolite-based sorbents for boron (B) removal from wastewater. Specifically, CFA constitutes the main source of Si and Al ions to produce zeolite type-A and the resulting sorbent subsequently undergoes simple cation exchange with Ca to enhance its B adsorption capacity. Structure and composition of the sorbents were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), inductively coupled plasma (ICP)-mass spectrometry (MS), and ICP-optical emission spectroscopy (OES). The Ca-modified zeolite sorbent derived from CFA exhibits comparable B removal capacity with similar commercial zeolites.

Muldoon, Patrick↗

Sister Rod Destructive Examinations (FY23): Appendix J: Leaching of High Burnup Used Nuclear Fuel in Deionized Water

The leaching experiment aims to understand the trends in the radiolysis-enhanced dissolution of HBU SNF when exposed to water (e.g., in-reactor or in-pool cladding failures). Specimens from a baseline M5-clad rod and a heat-treated M5 rod were cut from the fractured CIRFT specimens and placed in 100 mL deionized water for a period of 128 days. Both radial and axial sections were cut to provide different surface areas of fuel in contact with the leachate. During the four-month exposure period, aliquot samples of the leachate were analyzed using gamma spectroscopy and inductively coupled plasma - mass spectrometry (ICP-MS). The analysis quantified the amount of fuel leached into the solutions and provided individual isotopic release fractions (of 30+ isotopes) which were compared as a function of time and surface area of the fuel exposed. Consistent with existing literature, the leaching followed a trend in which isotopes of certain elements such as Cs and Mo were among the first species in the matrix to dissolve, and with the highest release rates. This was followed by a gradual matrix dissolution consisting of uranium and other actinides and a slower-than-matrix release from some isotopes, including Ru and Rh. It was also observed that the circumferential samples having less exposed fuel surface area (to begin with) leached more than the axial samples for a majority of the isotopes during the timespan of the study. Previous experiments were conducted by decladding or exposing the pellet-clad surface completely, but the samples used in this study retained the cladding. One possible explanation for the higher leaching rate of the circumferential samples is that the pellet-clad interface, which has a greater density of grain boundaries and defects, may be the most vulnerable area to leaching of fuel in the presence of water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prospecting for Critical Minerals and Rare Earth Elements from Marcellus Shale in the Western Portion of the Appalachian Basin with Non-Destructive Core Characterization

Identification of sources for domestic critical minerals and rare earth elements (CM/REE) has been deemed essential for the energy transition by the United States Department of Energy (DOE). The U.S. DOE’s National Energy Technology Laboratory’s (NETL) Geomaterials Characterization Laboratory has performed non-destructive core characterizations on energy-relevant rock cores for the past decade. During this time, NETL has published over 36 technical reports and made the associated data publicly available. Much of this work focuses on unconventional shale gas, subsurface carbon storage systems, and carbon-ore. These efforts provide cm-scale petrophysical and elemental data, photographic documentation, detailed core descriptions, and computed tomography (CT) data for each well. This provides a first phase prospecting resource for CM/REE resources and can provide a map for pin-pointing intervals and lithologies for further development. Using historical core characterization data from 12 Marcellus wells from the western portion of the Appalachian Basin, this study builds an improved understanding of the chemostratigraphy of the basin. X-ray fluorescence (XRF) and CT images were used to determine lithologic intervals and potential ore bodies for further analysis, including benchtop digestion and inductively coupled plasma mass spectrometry (ICP-MS) to better understand the CM/REE enrichments.

Paronish, Thomas J.↗

Portable fiber optic sensor for rare earth elements and other critical metals using photoluminescence methods

Rare earth elements and other metals are vital to a range of technologies that are used in the energy and defense sectors. However, monopolistic market conditions have caused significant concern over the stability of the critical metal supply chain, and this has spurred extensive efforts in many nations to produce these metals domestically, both from conventional sources such as mining and well as from unconventional sources such as coal and its utilization byproducts. Slow and expensive characterization methods pose a significant barrier for both metals prospecting and process monitoring. A promising solution to this challenge is the development of highly sensitive luminescent sensors for metals, which can offer low costs, portability, and sensitivity. Anionic zinc adeninate metal-organic frameworks (BioMOFs) are known to distinguishing and detect part-per-billion levels of terbium, europium, samarium, and dysprosium in water by sensitizing the narrow, element-specific emission bands from these lanthanides. Here, a BioMOF material is immobilized onto a large diameter, solarization-resistant fiber optic tip integrated with a portable, low-cost spectrometer for rare earth element sensing. Immobilizing the sensing material on fiber instead of dispersing the sensing material in solution offers several advantages: it facilitates solvent removal, which enhances luminescent signal from the sensitized lanthanides, and it also allows the BioMOF to be recycled for multiple uses. The sensing system was deployed on a simulated process stream and exhibited qualitative agreement with inductively-coupled plasma mass spectrometry for terbium and europium detection, highlighting the potential for the sensing system to be deployed for real-world applications. By using different sensing materials, the same portable sensor may be deployed to detect other energy relevant metals such as cobalt, providing a cost-effective and sensitive platform for critical metal characterization.

Crawford, Scott↗

Investigation of Undissolved Solids from Salt Waste Processing Facility (SWPF) Salt Batches Collected via Filtration

SRNL researchers performed six experiments wherein 0.1 μm-grade stainless steel filters were used to filter samples pulled from salt batches 6, 9B, and 11B, without the addition of monosodium titanate. Three of these experiments were performed to collect filterable solids from each salt batch and characterize trapped solids via scanning electron microscopy. The remaining three experiments were performed to collect and then dissolve the same solids using 3.5 M nitric acid (similar to that employed in the Salt Waste Processing Facility) for characterization via Inductively-coupled plasma atomic emission spectroscopy.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

C136A and C138A Report of Analysis

In this work the isotopic ratios and weight percentages of 238 Pu, 239 Pu, 240 Pu, 241 Pu and 242 Pu were determined using Isotope Dilution Mass Spectrometry. Two samples of C136A and C138A were sent to the Analytical Research laboratories by the National Nuclear Security Administration Nuclear Reference Material Program. The four samples were dissolved in concentrated hydrochloric acid. From the parent solutions, eight aliquots were taken, diluted, spiked with 244 Pu and submitted to separations. After the samples were separated, they were analyzed using Multicollector Inductively Coupled Plasma Mass Spectrometry. Along with the samples, two C126A Quality Control Samples were analyzed each day. Mass bias standards were also analyzed at the beginning, during and at the end of the analysis. GUM Workbench Pro software Version 2.4.1.406 was used to calculate the isotopic ratios relative to 239 Pu, and total Pu mass and the correlated expanded uncertainties.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Imaging and Analysis of Insoluble Electrorefiner Material

Throughout pyroprocessing efforts at the Hot Fuel Examination Facility (HFEF), insoluble material has accumulated in the Electrorefiner (ER) vessel. The objective of this effort was to analyze the accumulated material to determine its origin. Material was removed from the ER salt bath and distilled to remove excess salt prior to performing analysis. Three samples were sent for chemical and isotopic analysis and underwent an ethyl acetate-bromine dissolution to segregate the oxide fraction from the metal fraction. Actinide concentrations were determined using a quadrupole–inductively coupled plasma–mass spectrometer (Q-ICP-MS). Three additional samples were sent for morphologic and elemental analysis by scanning electron microscopy (SEM) with Energy Dispersive X-ray (EDX) analysis at the Irradiated Materials Characterization Laboratory (IMCL). Analyses suggest that the material is primarily composed of UO2. with a small fraction of metal. This study draws no single conclusion as to the origin of the insoluble material in the ER. The particle sizes and morphologies observed in SEM micrographs indicate that the larger particles observed may be a result of introducing material to the ER that has not been completely reduced in Oxide Reduction (OR) operations, which precede electrorefining. Smaller particles may be due to reactions with oxygen and moisture present in HFEF. This research suggests that microscopic analysis of fuel particles before and after OR operations (including after distillation) as well as the uranium product collected on the cathode in the ER would increase understanding about particle morphology within the pyrochemical process.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of U content in J-swipe/PIC samples

This final report documents the results of an evaluation of the U content in J-swipes for the International Atomic Energy Agency (IAEA). J-swipes are manufactured with inked numbers (1–30) and U backgrounds that are considered consistent across different lots and manufacturing times. These characteristics make them ideal for use by IAEA inspectors for pre-inspection check samples to ensure inspectors are not cross-contaminating sites. However, recent work has found elevated U concentrations in the inked numbers compared with the J-swipe material. To determine whether the inked numbers correlate with the U backgrounds, triplicate U content measurements were made on Swipes 1, 2, 11, 22, and 28. Triplicates of each swipe were processed through the standard chemistry used by the Oak Ridge National Laboratory Network of Analytical Laboratories team and analyzed for U content by isotope dilution via multicollector inductively coupled plasma mass spectrometry. Finally, samples were made by mass consisting of only ink areas and only cotton swipe material to determine the trace element differences between the cotton and the ink.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ORNL Report of Analysis for the Verification of NRMP CRM U030A

In support of the Certified Reference Material (CRM) program managed by the Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory (ORNL) was asked to prepare a set of CRM U030A units for use as standards for isotopic analysis using multicollector thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) instruments. This report documents the results of the verification measurements performed on three randomly selected units by the MSIS group’s ISO/IEC 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry [1], and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan [2].

Mathew, Kattathu [Oak Ridge National Laboratory (O↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Chloride Salt Purification by Reaction With Thionyl Chloride Vapors to Remove Oxygen, Oxygenated Compounds, and Hydroxides

Molten chloride salts (including MgCl 2 , KCl, NaCl, and ZnCl 2 ) are being considered for heat transfer media for renewable (solar) and nuclear power generators, as fuel carrier for nuclear reactors, and as thermal energy storage media. Impurities such as oxygen, hydroxides, moisture, and sulfur are known to negatively influence the corrosion of materials in contact with the salt (e.g., structural metals). Commercially available chloride salts come with a range of impurities. Before using the chloride salts at high temperature, it is desirable to remove the impurities to increase the performance of the salt and reduce corrosion. In this study, we tested the use of thionyl chloride vaporized into a stream of argon to react with oxygenated impurities in a mixture of MgCl 2 -KCl-NaCl, removing them as HCl and SO 2 . The reagent was bubbled through the salt when both above and below the melting point. The reaction was followed using thermocouple data from the salt and by Fourier transform infrared (FTIR) spectroscopy on the exhaust of the reactor. The reaction kinetics were followed by comparing the peaks from SO 2 product to SOCl 2 reagent in the FTIR spectra. The purity of the salt was assessed at the end of the purification process by x-ray diffraction and inductively coupled plasma analysis. Although the process was effective in removing the oxygen content of the mixture, ternary compounds were formed in the process, including KNiCl 3 and KMgCl 3 . The nickel in KNiCl 3 came from the reaction between the salt and the nickel vessel. Thus, these experiments suggest that improvements to the process must be made before using SOCl 2 vapors for the purification of chloride salts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utilization of 29Si MAS-NMR to Understand Solid State Diffusion in Energy Storage Materials

The properties of many solid-state materials arise from critical interfaces tied to the structure, morphology, and composition of the materials under study. For many materials, identifying components that may be invisible to diffraction techniques or other bulk sensitive techniques (i.e. inductively coupled plasma (ICP)), may cause important information to be overlooked. These can include grain boundary phases, nanoscale coatings, amorphous layers, or second phases that influence the materials environment. In this short review, the use of 29 Si MAS NMR as a local probe to detect silicon-containing phases in complex energy storage systems is explored with a focus is on silicon-containing materials and silicon electrodes. Examples highlighting the utility of 29 Si MAS NMR include 1) examining copper diffusion into silicon as a method to create 3 dimensional electrodes, 2) using Mg(II) electrolyte additives to create in-situ nanoscale silicide coatings to inhibit low voltage parasitic side reactions and extend calendar life, and 3) studying the lithiation reactions of passivated silicon on different time scales.

Dogan, Fulya↗

Understanding and Mitigating the Dissolution and Delamination Issues Encountered with High-Voltage LiNi 0.5 Mn 1.5 O 4

In our initial study on the high-voltage 5 V cobalt-free spinel LiNi 0.5 Mn 1.5 O 4 (LNMO) cathode, we discovered a severe delamination issue in the laminates when cycled at a high upper cut-off voltage (UCV) of 4.95 V, especially when a large cell format was used. This delamination problem prompted us to investigate further by studying the transition metal (TM) dissolution mechanism of cobalt-free LNMO cathodes, and as a comparison, some cobalt-containing lithium nickel manganese cobalt oxides (NMC) cathodes, as the leachates from the soaking experiment might be the culprit for the delamination. Unlike other previous reports, we are interested in the intrinsic stability of the cathode in the presence of a baseline Gen2 electrolyte consisting of 1.2 M of LiPF 6 in ethylene carbonate/ethyl methyl carbonate (EC/EMC), similar to a storage condition. The electrode laminates (transition metal oxides, transition metal oxides, TMOs, coated on an Al current collector with a loading level of around 2.5 mAh/cm 2 ) or the TMO powders (pure commercial quality spinel LNMO, NMC, etc.) were stored in the baseline solution, and the transition metal dissolution was studied through nuclear magnetic resonance, such as 1 H NMR, 19 F NMR, scanning electron microscope (SEM), X-ray photoelectron spectroscopy (XPS) and inductively coupled plasma mass spectrometry (ICP-MS). Significant electrolyte decomposition was observed and could be the cause that leads to the TM dissolution of LNMO. To address this TM dissolution, additives were introduced into the baseline electrolyte, effectively alleviating the issue of TM dissolution. The results suggest that the observed delamination is caused by electrolyte decompositions that lead to etching, and additives such as lithium difluorooxalato borate and p-toluenesulfonyl isocyanate can alleviate this issue by forming a firm cathode electrolyte interface. This study provides a new perspective on cell degradation induced by electrode/electrolyte interactions under storage conditions.

25 ENERGY STORAGE↗