Search NASA⌕ Search

SEARCH · Search NASA

Results for “LASER TARGETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Progress in coherent laser radar

Considerable progress with coherent laser radar has been made over the last few years, most notably perhaps in the available range of high performance devices and components and the confidence with which systems may now be taken into the field for prolonged periods of operation. Some of this increasing maturity was evident at the 3rd Topical Meeting on Coherent Laser Radar: Technology and Applications. Topics included in discussions were: mesoscale wind fields, nocturnal valley drainage and clear air down bursts; airborne Doppler lidar studies and comparison of ground and airborne wind measurement; wind measurement over the sea for comparison with satellite borne microwave sensors; transport of wake vortices at airfield; coherent DIAL methods; a newly assembled Nd-YAG coherent lidar system; backscatter profiles in the atmosphere and wavelength dependence over the 9 to 11 micrometer region; beam propagation; rock and soil classification with an airborne 4-laser system; technology of a global wind profiling system; target calibration; ranging and imaging with coherent pulsed and CW system; signal fluctuations and speckle. Some of these activities are briefly reviewed.

Vaughan, J. M.↗

Time- and position-varying infrared scene simulation

Rapidly changing infrared scenes can be generated as a function of position using thermally produced irradiance. This can be done most conveniently by using a variable dwell-time, variable diameter, and scanning laser beam to deposit a predetermined amount of laser energy, as a function of position, on the target surface. An infrared target simulator has been designed and tested to perform within stringent temperature simulation requirements: heating rate of over 100 K/sec is achieved, and temperature gradients of 200 K/mm can be maintained. Problems with heat transfer between adjacent elements at different temperatures are solved by modeling the thermal layer on the target surface as a low-pass filter, which cuts off all the frequencies above the thermal cutoff frequency. When the system approach is taken to the infrared simulation design, the optical system limited performance results in the best realizable performance. In this case, the thermal layer on the target surface is designed so that the thermal cutoff frequency is above the optical cutoff frequency.

Scholl, Marija S.↗

Space-stabilized beam pointing for a bifocal satellite experiment

The pointing and tracking control concept for an experimental ground-based laser beam relay satellite is described. The satellite receives a low-power laser beam from a ground-based laser, processes it, and reflects it to an instrumented target. The primary control objective is to achieve extremely accurate and stable pointing at the target, including moving targets. This is achieved using an optical/inertial stabilization technique. The paper describes the satellite optical layout and pointing control mechanization.

Redding, David C.↗

High-Power Single-Mode 2.65-micron InGaAsSb/AlInGaAsSb Diode Lasers

Central to the advancement of both satellite and in-situ science are improvements in continuous-wave and pulsed infrared laser systems coupled with integrated miniaturized optics and electronics, allowing for the use of powerful, single-mode light sources aboard both satellite and unmanned aerial vehicle platforms. There is a technological gap in supplying adequate laser sources to address the mid-infrared spectral window for spectroscopic characterization of important atmospheric gases. For high-power applications between 2 to 3 micron, commercial laser technologies are unsuitable because of limitations in output power. For instance, existing InP-based laser systems developed for fiber-based telecommunications cannot be extended to wavelengths longer than 2 micron. For emission wavelengths shorter than 3 micron, intersubband devices, such as infrared quantum cascade lasers, become inefficient due to band-offset limitations. To date, successfully demonstrated singlemode GaSb-based laser diodes emitting between 2 and 3 micron have employed lossy metal Bragg gratings for distributed- feedback coupling, which limits output power due to optical absorption. By optimizing both the quantum well design and the grating fabrication process, index-coupled distributed-feedback 2.65-micron lasers capable of emitting in excess of 25 mW at room temperature have been demonstrated. Specifically, lasers at 3,777/cm (2.65 micron) have been realized to interact with strong absorption lines of HDO and other isotopologues of H2O. With minor modifications of the optical cavity and quantum well designs, lasers can be fabricated at any wavelength within the 2-to-3-micron spectral window with similar performance. At the time of this reporting, lasers with this output power and wavelength accuracy are not commercially available. Monolithic ridge-waveguide GaSb lasers were fabricated that utilize secondorder lateral Bragg gratings to generate single-mode emission from InGaAsSb/ AlInGaAsSb multi-quantum well structures. The device fabrication utilizes etched index-coupled gratings in the top AlGaAsSb cladding of the laser chip along the ridge waveguide, whereas commercial lasers that emit close to this wavelength include loss-coupled metal gratings that limit the output power of the laser. Semiconductor-laser-based spectrometers can be used to replace gas sensors currently used in industry and government. With the availability of high-power laser sources at mid-infrared wavelengths, sensors can target strong fundamental gas absorption lines to maximize instrument sensitivity.

Frez, Clifford F.↗

Chemical Pollution from Combustion of Modern Spacecraft Materials

Fire is one of the most critical contingencies in spacecraft and any closed environment including submarines. Currently, NASA uses particle based technology to detect fires and hand-held combustion product monitors to track the clean-up and restoration of habitable cabin environment after the fire is extinguished. In the future, chemical detection could augment particle detection to eliminate frequent nuisance false alarms triggered by dust. In the interest of understanding combustion from both particulate and chemical generation, NASA Centers have been collaborating on combustion studies at White Sands Test Facility using modern spacecraft materials as fuels, and both old and new technology to measure the chemical and particulate products of combustion. The tests attempted to study smoldering pyrolysis at relatively low temperatures without ignition to flaming conditions. This paper will summarize the results of two 1-week long tests undertaken in 2012, focusing on the chemical products of combustion. The results confirm the key chemical products are carbon monoxide (CO), hydrogen cyanide (HCN), hydrogen fluoride (HF) and hydrogen chloride (HCl), whose concentrations depend on the particular material and test conditions. For example, modern aerospace wire insulation produces significant concentration of HF, which persists in the test chamber longer than anticipated. These compounds are the analytical targets identified for the development of new tunable diode laser based hand-held monitors, to replace the aging electrochemical sensor based devices currently in use on the International Space Station.

Mudgett, Paul D.↗

Diagenetic Features Analyzed by ChemCam/Curiosity at Pahrump Hills, Gale Crater, Mars

Onboard the Mars Science Laboratory (MSL) Curiosity rover, the ChemCam instrument consists of : (1) a Laser-Induced Breakdown Spectrometer (LIBS) for elemental analysis of targets and (2) a Remote Micro Imager (RMI), which provides imaging context for the LIBS. The LIBS/ChemCam performs analysis typically of spot sizes 350-550 micrometers in diameter, up to 7 meters from the rover. Within Gale crater, Curiosity traveled from Bradbury Landing toward the base of Mount Sharp, reaching Pahrump Hills outcrop circa sol 750. This region, as seen from orbit, represents the first exposures of lower Mount Sharp. In this abstract we focus on two types of features present within the Pahrump Hills outcrop: concretion features and light-toned veins.

Nachon, M.↗

Cryogenic Thermal Vacuum Testing with Remote Optical Metrology

Flexure Engineering was awarded an SBIR to research and develop technology needed to build a thermal vacuum chamber made to take laser radar metrology through a window. The XATF test is proof of concept for this, and demonstrated the need for such a chamber. XATF refers to two pieces of critical ground support equipment for NASA's JWST (James Webb Space Telescope) Integrated Science Instrument Module (ISIM), the ISIM Alignment Target Fixture (IATF) and the Master Alignment Target Fixture (MATF). These optical alignment assemblies require characterization while under cryogenic temperature. A thermal vacuum chamber equipped with a shroud cooled with gaseous and liquid nitrogen was used. An inner shroud was cooled with liquid helium to approximately 30K. The XATF assemblies were kinematically mounted and oriented inside the inner shroud such that the optical targets were visible from outside an optical window on one of the chamber ports. Laser radar and theodolite mounted outside the window took measurements of various optical targets. Two cold cycles were completed. A third cycle was aborted. Metrology was successfully taken. There were some problems with the helium system. The cryo pumps were turned off to reduce vibrations during metrology. Many new technologies and testing methods must be developed for JWST and future programs that will require precision measurements. These technologies will be applicable to other cold temperature applications, such as lunar missions and superconductors. Remote metrology technologies can also be applicable to testing in harsh environments. Facilities with remote metrology capability will be valuable.

Boyd, Guinevere↗

Portable 4.6 Micrometers Laser Absorption Spectrometer for Carbon Monoxide Monitoring and Fire Detection

The air quality aboard manned spacecraft must be continuously monitored to ensure crew safety and identify equipment malfunctions. In particular, accurate real-time monitoring of carbon monoxide (CO) levels helps to prevent chronic exposure and can also provide early detection of combustion-related hazards. For long-duration missions, environmental monitoring grows in importance, but the mass and volume of monitoring instruments must be minimized. Furthermore, environmental analysis beyond low-Earth orbit must be performed in-situ, as sample return becomes impractical. Due to their small size, low power draw, and performance reliability, semiconductor-laser-based absorption spectrometers are viable candidates for this purpose. To reduce instrument form factor and complexity, the emission wavelength of the laser source should coincide with strong fundamental absorption lines of the target gases, which occur in the 3 to 5 micrometers wavelength range for most combustion products of interest, thereby reducing the absorption path length required for low-level concentration measurements. To address the needs of current and future NASA missions, we have developed a prototype absorption spectrometer using a semiconductor quantum cascade laser source operating near 4.6 micrometers that can be used to detect low concentrations of CO with a compact single-pass absorption cell. In this study, we present the design of the prototype instrument and report on measurements of CO emissions from the combustion of a variety of aerospace plastics.

Tunable Environmental Laser Spectrometer (TELS)↗

Higher Order Chemistry Models in the CFD Simulation of Laser-Ablated Carbon Plumes

Production of single-walled carbon nanotubes (SWNT) has taken place for a number of years and by a variety of methods such-as laser ablation, chemical vapor deposition, and arc-jet ablation. Yet, little is actually understood about the exact chemical kinetics and processes that occur in SWNT formation. In recent time, NASA Johnson Space Center has devoted a considerable effort to the experimental evaluation of the laser ablation production process for SWNT originally developed at Rice University. To fully understand the nature of the laser ablation process it is necessary to understand the development of the carbon plume dynamics within the laser ablation oven. The present work is a continuation of previous studies into the efforts to model plume dynamics using computational fluid dynamics (CFD). The ultimate goal of the work is to improve understanding of the laser ablation process, and through that improved understanding, refine the laser ablation production of SWNT. Fig. 1 shows a basic schematic of the laser-ablation oven at NASA-JSC. Construction of the facility is simple in concept. Two concentric quartz tubes of 1.5 mm thickness form the inner and outer tubes with inside diameters of 2.2 and 5.08 cm respectively. At one end of the inner tube are located two 60 Hz pulsed lasers operating at 1064 nm and 532 nm wavelength with beam diameters of 5 mm aligned coaxially with the longitudinal axis of the inner quartz tube. For standard nanotube production runs, a 10 ns 532 nm pulse is followed 50 ns later by a 10 ns 1064 nm pulse. Each pulse is of 300 mJ energy. A target of carbon graphite with approximately 1% nickel and cobalt catalysts is located at the other end of the inner quartz tube. In the ordinary processing of SWNT, a base flow of 100 sccm of argon is maintained from the laser location and exits past the carbon target at a pressure of 66.7 kPa. These conditions yield a baseline mass flow through the chamber of 2.723x10(exp -6)kg/s of argon. The whole oven facility is heated to a temperature of 1473 K prior to nanotube production runs. Upon laser irradiation, part of the carbon target ablates immediately and forms a carbon vapor plume that penetrates into the argon base flow towards the laser initially at supersonic velocities. In the previous studies either a single carbon species, C3, was used to model the plume development, or a simplified 11 species carbon model reduced down from the Krestinin and Moravsky model for full fullerene chemistry was used. While both of these options yielded significant results, it was felt that the actual chemistry occ&g in the carbon plume might have a greater affect on the plume than assumed. Indeed, in the earlier attempts at modeling the carbon plume, several thermophysical characteristics could never be matched to experimental observations of plume development - mainly the propagation distance of the plume itself. In the present study, two additional chemistry models will be used to duplicate the previous studies simulations of the carbon plume. The first chemistry model used in this study is again a reduced form of the Krestinin and Moravsky rates. However the highest order carbon species allowed has been increased from C6 to C30 - therefore allowing the simulation of up to a half of the standard C60 fullerene. The second chemistry model investigated is a reduced form of a full carbon nanotube model developed at NASA-JSC. The C30 studies have already been accomplished at the present time, and the reduced SWNT model studies are currently underway. To pursue the current study, one sacrifice had to be made in that the simulation grid spacing had to be increased from 0.5 mm spacing to 1 mm spacing for the sake of computational efficiency since computational effort is proportional to the square of the number of grid points multiplied by the number of species considered. propagation that is far more in line with the experimental results observed by Puretzky et al as shown in Fig. 2. e C6 studies had yielded a far greater propagation in previous studies. In addition, chemical species development with the C30 model indicates that many higher order carbon species are produced outside of the plume proper (indicated by plotting contours of the background argon concentrations in Fig. 3) - this result was not observed in previous studies. In fact, some species primarily occurred outside of the plume itself - as shown for C27 in Fig. 4 when it is compared to Fig. 3. It could be asserted that this has occurred because all of the C27 in the plume had already been consumed in the formation of C30, but this does not seem to be indicated over time. Several other factors that arose in the previous studies have also been made more clear by the use of the higher order chemical models - one being that the use of c6 as an indicator species was mistaken. C6 is the only carbon species in the previous studies that was not injected into the flowfield as a boundary condition; it was therefore hoped that this species would provide insight into the formation of higher order carbon species for comparison to full SWNT production. But, when the plot of total mass in the plume is examined on a species by species basis in Fig. 5, it is seen that Cg was a fairly insignificant contributor to the total carbon mass in the plume and would not provide information on higher order carbon formation. the thermophysical characteristics of the carbon plume as well as simulate the carbon plume using the reduced SWNT model to provide an even better simulation of full chemistry effects upon plume propagation.

Scott, C. D.↗

Wide-Field Optic for Autonomous Acquisition of Laser Link

An innovation reported in Two-Camera Acquisition and Tracking of a Flying Target, NASA Tech Briefs, Vol. 32, No. 8 (August 2008), p. 20, used a commercial fish-eye lens and an electronic imaging camera for initially locating objects with subsequent handover to an actuated narrow-field camera. But this operated against a dark-sky background. An improved solution involves an optical design based on custom optical components for the wide-field optical system that directly addresses the key limitations in acquiring a laser signal from a moving source such as an aircraft or a spacecraft. The first challenge was to increase the light collection entrance aperture diameter, which was approximately 1 mm in the first prototype. The new design presented here increases this entrance aperture diameter to 4.2 mm, which is equivalent to a more than 16 times larger collection area. One of the trades made in realizing this improvement was to restrict the field-of-view to +80 deg. elevation and 360 azimuth. This trade stems from practical considerations where laser beam propagation over the excessively high air mass, which is in the line of sight (LOS) at low elevation angles, results in vulnerability to severe atmospheric turbulence and attenuation. An additional benefit of the new design is that the large entrance aperture is maintained even at large off-axis angles when the optic is pointed at zenith. The second critical limitation for implementing spectral filtering in the design was tackled by collimating the light prior to focusing it onto the focal plane. This allows the placement of the narrow spectral filter in the collimated portion of the beam. For the narrow band spectral filter to function properly, it is necessary to adequately control the range of incident angles at which received light intercepts the filter. When this angle is restricted via collimation, narrower spectral filtering can be implemented. The collimated beam (and the filter) must be relatively large to reduce the incident angle down to only a few degrees. In the presented embodiment, the filter diameter is more than ten times larger than the entrance aperture. Specifically, the filter has a clear aperture of about 51 mm. The optical design is refractive, and is comprised of nine custom refractive elements and an interference filter. The restricted maximum angle through the narrow-band filter ensures the efficient use of a 2-nm noise equivalent bandwidth spectral width optical filter at low elevation angles (where the range is longest), at the expense of less efficiency for high elevations, which can be tolerated because the range at high elevation angles is shorter. The image circle is 12 mm in diameter, mapped to 80 x 360 of sky, centered on the zenith.

Page, Norman A.↗

Analysis of short pulse laser altimetry data obtained over horizontal path

Recent pulsed measurements of atmospheric delay obtained by ranging to the more realistic targets including a simulated ocean target and an extended plate target are discussed. These measurements are used to estimate the expected timing accuracy of a correlation receiver system. The experimental work was conducted using a pulsed two color laser altimeter.

Im, K. E.↗

Analysis of Photogrammetry Data from ISIM Mockup

During ground testing of the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST), the ISIM Optics group plans to use a Photogrammetry Measurement System for cryogenic calibration of specific target points on the ISIM composite structure and Science Instrument optical benches and other GSE equipment. This testing will occur in the Space Environmental Systems (SES) chamber at Goddard Space Flight Center. Close range photogrammetry is a 3 dimensional metrology system using triangulation to locate custom targets in 3 coordinates via a collection of digital photographs taken from various locations and orientations. These photos are connected using coded targets, special targets that are recognized by the software and can thus correlate the images to provide a 3 dimensional map of the targets, and scaled via well calibrated scale bars. Photogrammetry solves for the camera location and coordinates of the targets simultaneously through the bundling procedure contained in the V-STARS software, proprietary software owned by Geodetic Systems Inc. The primary objectives of the metrology performed on the ISIM mock-up were (1) to quantify the accuracy of the INCA3 photogrammetry camera on a representative full scale version of the ISIM structure at ambient temperature by comparing the measurements obtained with this camera to measurements using the Leica laser tracker system and (2), empirically determine the smallest increment of target position movement that can be resolved by the PG camera in the test setup, i.e., precision, or resolution. In addition, the geometrical details of the test setup defined during the mockup testing, such as target locations and camera positions, will contribute to the final design of the photogrammetry system to be used on the ISIM Flight Structure.

Nowak, Maria↗

Laser docking system flight experiment

Experiments necessary in the development of the Laser Docking System (LDS) are described. The LDS would be mounted in the Orbiter payload bay, along with a grid connected by fiber optic link to a computer in the cabin. The tests would be performed to aid in the design of an operational sensor which could track a passive target accurately enough to permit soft docking. Additional data would be gained regarding the LDS performance in space, the effects of Orbiter RCS plume impingement on the target, and refinements needed for the flight hardware. A working model which includes an IR laser steered by galvanometer-driven motors for bouncing beams off retroreflectors mounted on targets is described, together with a 300 ft long indoor test facility. Tests on Orbiter flights would first be in a wholly automatic mode and then in a man-in-the-loop mode.

Erwin, Harry O.↗

New Topographic Products for the Lunar South Pole from the Lunar Orbiter Laser Altimeter (LOLA)

Due to the Moon’s low obliquity and highly cratered topography, its polar environments host regions of extreme illumination conditions. Multiple lines of evidence indicate the presence of geologically stable ice and other volatiles on or below the surface within polar permanently shadowed regions (PSRs). These regions are valuable targets for science and exploration as they hold clues to the history of water in the inner solar system and may hold sufficient reserves for in-situ resource utilization. Standing high above the PSRs, peaks of long-duration sunlight are oases where landed assets can easily generate power and communicate. For these reasons, the lunar south pole is the target of many upcoming missions including NASA’s Artemis program. The Lunar Orbiter Laser Altimeter (LOLA) onboard the Lunar Reconnaissance Orbiter (LRO) provides the global geodetic framework with which past, present, and future missions can accurately geolocate their data. Laser altimeters like LOLA are unaffected by shadows and, therefore, provide the most direct measurements of topography within PSRs. Here we present the latest work to improve LOLA’s polar topographic maps and resulting derived products, such as PSR maps, which are crucial tools for science and exploration of the polar regions

Michael K Barker↗

Continuous wave coherent laser radar - Calculation of measurement location and volume

The SNR equation of a CW, monostatic, coherent laser radar system is examined for the case of a distributed aerosol target. General analytic equations are derived which explicitly describe the contribution to total SNR from each range interval along the optic axis, the range resolution of the measurement, and the atmospheric volume contributing to the measurement. Plots are presented showing the location in range and the volume of the laser radar measurement.

Kavaya, Michael J.↗

Interaction of high-intensity laser radiation with metals.

The interaction is characterized by the production of plasma, within which the primary absorption occurs. Absorption of laser radiation by a plasma may occur by several processes. The absorption process called 'inverse bremsstrahlung' is discussed. The interaction of a laser beam with the plasma produced from a thick metal target was studied. The results of the measurements of the ion kinetic energies are presented in a graph. In addition to measurements with thick targets, information was also obtained with a thin foil of gold.

Linlor, W. I.↗

Rangefinder Corrects for Air Density and Moisture

Proposed distance-measuring instrument compensates for variations in both dry atmospheric density and water-vapor content. Instrument would be expected to be more accurate than previous laser-ranging instruments. New rangefinder sends three signal trains to target: Two trains are at optical frequencies, and one is at a microwave frequency. All three signals are phase-locked.

Abshire, J. B.↗

Extended temperature range studies for dry heat microbial reduction

This paper will present the lethality data that has been collected at this time and the planned future studies. The results show that rapid ramp-up heating times are critical to obtaining valid lethality data at high temperatures because an extensive number of spores are killed before reaching the target temperature. Exploratory experiments have also been performed using a laser to rapidly heat coupons.

microbial reduction↗