Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Multi-Scale Analysis of an Ilmenite Microcrater in Lunar Sample 71055

Micrometeorite impacts are a key space weathering process on the lunar surface, generating a variety of physical and chemical changes in the lunar regolith. Several experiments using nanosecond pulsed lasers to simulate micrometeorite impact have been published in the past two decades, providing a wealth of knowledge, including how minerals vary in their response to laser irradiation. Although these experiments have produced many features analogous to those observed in natural samples, none could be attributed to the passage of a shock wave, resulting instead from hot ablation. Recent femtosecond laser irradiation of olivine and enstatite have more accurately reproduced the shock textures observed in lunar samples, improving our ability to coordinate experimental and lunar sample data. Both pulsed laser experiments and studies of lunar impact craters have focused on silicates, as they comprise the bulk of the regolith. Ilmenite (FeTiO 3 ) is the most abundant opaque mineral in lunar rocks and an important sink of solar wind implanted helium. Ilmenite is known to vary in its response to radiation processing relative to the silicates, but its response to micrometeorite impact has not yet been studied in natural samples nor in the laboratory. In this investigation, we characterize an ilmenite microcrater using scanning electron microscopy (SEM) and transmission electron microscopy (TEM) to learn how ilmenite responds to impact and if there are implications for helium cycling in the regolith.

B A Cymes↗

N2O5 photolysis products investigated by fluorescence and optoacoustic techniques

Pulsed laser photolysis of N2O5 near 290 nm, coupled with fluorescence detection (calibrated by NO2 photoloysis), showed that the O(P-3) quantum yield is not more than 0.1. A pulsed laser optoacoustic technique in a flow tube was tested by photolysis of NO2 and then applied to N2O5. Nitric oxide was added to react with NO3 free radicals; the resulting increase in the optoacoustic signal confirmed the presence of NO3 free radicals. Based on the relative optoacoustic signals observed for NO2 and N2O5, the quantum yield for NO3 production is 0.8 + or - 0.2.

Barker, J. R.↗

Microbial Methods for Testing a Novel Spacecraft Bioburden Reduction Method

In order to circumvent the contamination of microorganisms in both extraterrestrial and terrestrial environments, spacecraft hardware must often be sterilized. Current sterilization practices are both time-consuming and expensive. Techniques such as dry heat sterilization and scattered/localized electric field enhancements are incompatible with a variety of hardware materials as well as complex surface shapes. Our group is testing a novel femtosecond pulsed laser for the rapid sterilization of spacecraft hardware using high photon fluxes, which is both an efficient and effective technique to ensure a reduced microbial burden aboard spacecraft. This method is likely to be effective because microorganisms have not encountered high photon fluxes in their evolutionary history and thus contain no protective mechanisms against them. To assess the effectiveness of pulsed laser sterilization, we used a combination of scanning electron microscopy and elemental analysis for the examination of damaged spores on metal coupons, as well as microbiology methods for spore assays. The surfaces of metal coupons inoculated with Bacillus subtilis were illuminated with femtosecond pulses at various wavelengths below the damage threshold for the aluminum. After laser treatment, metal coupon samples were sonicated to dislodge spores, serially diluted, and finally plated and incubated. Results show that sterilization efficiency is favorable in some conditions. The NASA standards for spore assays are a preliminary demonstration in establishing the trend in ability to kill spores. The results show potential for the dual pulse illumination method as a sterilization technique for planetary protection applications.

Maha S Ulhaq↗

Calibration of the MSL/ChemCam/LIBS Remote Sensing Composition Instrument

The ChemCam instrument suite on board the 2011 Mars Science Laboratory (MSL) Rover, Curiosity, will provide remote-sensing composition information for rock and soil samples within seven meters of the rover using a laser-induced breakdown spectroscopy (LIBS) system, and will provide context imaging with a resolution of 0.10 mradians using the remote micro-imager (RMI) camera. The high resolution is needed to image the small analysis footprint of the LIBS system, at 0.2-0.6 mm diameter. This fine scale analytical capability will enable remote probing of stratigraphic layers or other small features the size of "blueberries" or smaller. ChemCam is intended for rapid survey analyses within 7 m of the rover, with each measurement taking less than 6 minutes. Repeated laser pulses remove dust coatings and provide depth profiles through weathering layers, allowing detailed investigation of rock varnish features as well as analysis of the underlying pristine rock composition. The LIBS technique uses brief laser pulses greater than 10 MW/square mm to ablate and electrically excite material from the sample of interest. The plasma emits photons with wavelengths characteristic of the elements present in the material, permitting detection and quantification of nearly all elements, including the light elements H, Li, Be, B, C, N, O. ChemCam LIBS projects 14 mJ of 1067 nm photons on target and covers a spectral range of 240-850 nm with resolutions between 0.15 and 0.60 nm FWHM. The Nd:KGW laser is passively cooled and is tuned to provide maximum power output from -10 to 0 C, though it can operate at 20% degraded energy output at room temperature. Preliminary calibrations were carried out on the flight model (FM) in 2008. However, the detectors were replaced in 2009, and final calibrations occurred in April-June, 2010. This presentation describes the LIBS calibration and characterization procedures and results, and details plans for final analyses during rover system thermal testing, planned for early March.

Wiens, R. C.↗

Single Pulse Remote Raman Detection of Minerals and Organics Under Illuminated Condition from 10 Meters Distance

A directly coupled portable remote Raman instrument developed by the University of Hawaii has been shown here to identify several minerals, chemicals and organics from a distance of 10 m using a single laser pulse in a well illuminated background. Raman spectra, obtained during a very short period of time, of common minerals e.g., dolomite, calcite, marble, barite, gypsum, quarts, rutile, fluorapatite etc. clearly show Raman features which could be used as fingerprints for mineral identification. Raman features of organics such as benzene, cyclohexane, 2-propanol, naphthalene, etc. and other chemicals containing various functional groups like oxides, silicates, sulphates, nitrates, phosphates and carbonates were also easily detected. Ability to measure Raman spectra with a single laser pulse would be promising for future space missions where power consumption is critical and a rapid survey of the minerals with moderate to high Raman cross section might be desirable for selecting rocks that would provide high scientific return or for acquiring rocks for sample return to the Earth.

Misra, A. K.↗

Correction function in the Lidar equation and the solution techniques for CO2 Lidar date reduction

For lidar systems with long laser pulses the unusual behavior of the near-range signals causes serious difficulties and large errors in reduction. The commonly used lidar equation is no longer applicable since the convolution of the laser pulse with the atmospheric parameter distributions should be taken into account. It is important to give more insight into this problem and find the solution techniques. Starting from the original equation, a general form is suggested for the single scattering lidar equation where a correction function Cr is introduced. The correction Function Cr(R) derived from the original equation indicates the departure from the normal lidar equation. Examples of Cr(R) for a coaxial CO2 lidar system are presented. The Differential Absorption Lidar (DIAL) errors caused by the differences of Cr(R) for H2O measurements are plotted against height.

Zhao, Y.↗

Remote sensing of sea state by laser altimeters

The reflection of short laser pulses from the ocean surface was analyzed based on the specular point theory of scattering. The expressions for the averaged received signal, shot noise and speckle induced noise were derived for a direct detection system. It is found that the reflected laser pulses have an average shape closely related to the probability density function associated with the surface profile. This result is applied to estimate the mean sea level and significant wave height from the receiver output of the laser altimeter.

Tsai, B.↗

Thermal diffusivity of diamond films

A laser pulse technique to measure the thermal diffusivity of diamond films deposited on a silicon substrate is developed. The effective thermal diffusivity of diamond film on silicon was measured by observing the phase and amplitude of the cyclic thermal waves generated by the laser pulses. An analytical model is developed to calculate the effective in-plane (face-parallel) diffusivity of a two layer system. The model is used to reduce the effective thermal diffusivity of the diamond/silicon sample to a value for the thermal diffusivity and conductivity of the diamond film. Phase and amplitude measurements give similar results. The thermal conductivity of the films is found to be better than that of type 1a natural diamond.

Albin, Sacharia↗

Studies of a Space Lidar Instrument for the ASCENDS Mission

We have developed a lidar technique for measuring the tropospheric C02 concentrations as a candidate for NASA's planned ASCENDS mission. Our technique uses two pulsed laser transmitters allowing simultaneous measurement of a C02 absorption line in the 1570 nm band, 02 extinction in the Oxygen A-band and surface height and backscatter. The lidar measures the energy and time of flight of the laser echoes reflected from the atmosphere and surface. The lasers are stepped in wavelength across the C02 line and an 02 line region during the measurement. The receiver uses a telescope and photon counting detectors, and measures the background light and energies of the laser echoes from the surface along with scattering from any aerosols in the path. The gas extinction and column densities for the C02 and 02 gases are estimated from the ratio of the on- and off- line signals via the DIAL technique. Pulsed laser signals and a time gated receiver are used to isolate the laser echo signals from the surface, to reject laser photons scattered in the atmosphere, and measure the surface height and scattering profile in the path. We have recently completed a second design study for the space instrument. For the study, we selected a nominal sun-synchronous orbit with an altitude of 400 km and equator crossing time of 1:30 pm, and a receiver telescope with 1.5 m diameter.

Abshire, J. B.↗

Doublet Pulse Coherent Laser Radar for Tracking of Resident Space Objects

In this paper, the development of a long range ladar system known as ExoSPEAR at NASA Langley Research Center for tracking rapidly moving resident space objects is discussed. Based on 100 W, nanosecond class, near-IR laser, this ladar system with coherent detection technique is currently being investigated for short dwell time measurements of resident space objects (RSOs) in LEO and beyond for space surveillance applications. This unique ladar architecture is configured using a continuously agile doublet-pulse waveform scheme coupled to a closed-loop tracking and control loop approach to simultaneously achieve mm class range precision and mm/s velocity precision and hence obtain unprecedented track accuracies. Salient features of the design architecture followed by performance modeling and engagement simulations illustrating the dependence of range and velocity precision in LEO orbits on ladar parameters are presented. Estimated limits on detectable optical cross sections of RSOs in LEO orbits are discussed.

Prasad, Narasimha S.↗

A comparison between pulsed and CW laser annealing for solar cell applications

The application of laser processing in solar cell fabrication is considered. Specific emphasis is placed on a process developed for the fabrication of a 16.6% silicon solar cell using pulsed laser processing. Results are presented which compare pulsed laser annealing with CW laser annealing in solar cell fabrication.

Jellison, G. E., Jr.↗

Streak camera based SLR receiver for two color atmospheric measurements

To realize accurate two-color differential measurements, an image digitizing system with variable spatial resolution was designed, built, and integrated to a photon-counting picosecond streak camera, yielding a temporal scan resolution better than 300 femtosecond/pixel. The streak camera is configured to operate with 3 spatial channels; two of these support green (532 nm) and uv (355 nm) while the third accommodates reference pulses (764 nm) for real-time calibration. Critical parameters affecting differential timing accuracy such as pulse width and shape, number of received photons, streak camera/imaging system nonlinearities, dynamic range, and noise characteristics were investigated to optimize the system for accurate differential delay measurements. The streak camera output image consists of three image fields, each field is 1024 pixels along the time axis and 16 pixels across the spatial axis. Each of the image fields may be independently positioned across the spatial axis. Two of the image fields are used for the two wavelengths used in the experiment; the third window measures the temporal separation of a pair of diode laser pulses which verify the streak camera sweep speed for each data frame. The sum of the 16 pixel intensities across each of the 1024 temporal positions for the three data windows is used to extract the three waveforms. The waveform data is processed using an iterative three-point running average filter (10 to 30 iterations are used) to remove high-frequency structure. The pulse pair separations are determined using the half-max and centroid type analysis. Rigorous experimental verification has demonstrated that this simplified process provides the best measurement accuracy. To calibrate the receiver system sweep, two laser pulses with precisely known temporal separation are scanned along the full length of the sweep axis. The experimental measurements are then modeled using polynomial regression to obtain a best fit to the data. Data aggregation using normal point approach has provided accurate data fitting techniques and is found to be much more convenient than using the full rate single shot data. The systematic errors from this model have been found to be less than 3 ps for normal points.

Varghese, Thomas K.↗

Spectrally Tailored Pulsed Thulium Fiber Laser System for Broadband Lidar CO2 Sensing

Thulium doped pulsed fiber lasers are capable of meeting the spectral, temporal, efficiency, size and weight demands of defense and civil applications for pulsed lasers in the eye-safe spectral regime due to inherent mechanical stability, compact "all-fiber" master oscillator power amplifier (MOPA) architectures, high beam quality and efficiency. Thulium fiber's longer operating wavelength allows use of larger fiber cores without compromising beam quality, increasing potential single aperture pulse energies. Applications of these lasers include eye-safe laser ranging, frequency conversion to longer or shorter wavelengths for IR countermeasures and sensing applications with otherwise tough to achieve wavelengths and detection of atmospheric species including CO2 and water vapor. Performance of a portable thulium fiber laser system developed for CO2 sensing via a broadband lidar technique with an etalon based sensor will be discussed. The fielded laser operates with approximately 280 J pulse energy in 90-150ns pulses over a tunable 110nm spectral range and has a uniquely tailored broadband spectral output allowing the sensing of multiple CO2 lines simultaneously, simplifying future potentially space based CO2 sensing instruments by reducing the number and complexity of lasers required to carry out high precision sensing missions. Power scaling and future "all fiber" system configurations for a number of ranging, sensing, countermeasures and other yet to be defined applications by use of flexible spectral and temporal performance master oscillators will be discussed. The compact, low mass, robust, efficient and readily power scalable nature of "all-fiber" thulium lasers makes them ideal candidates for use in future space based sensing applications.

Heaps, William S.↗

Status of the Ablative Laser Propulsion Studies

We present a short review of our laser-propulsion research as well as some of the current results of the Ablative Laser Propulsion (ALP) studies currently underway at the University of Alabama in Huntsville. It has been shown that direct surface ablation of a solid material produces high specific impulse (Isp) at relatively high energy conversion efficiency (20 - 40%). We detail measurements of specific impulse, thrust and coupling coefficients for elemental target materials both with single and with double pulse laser shots. We also present measurements taken using three independent methods for determination of Isp. The three methods produce consistent values from ion time-of-flight technique, impulse measurements and imaging of the expansion front of plasma plume. We present a demonstration of our ALP lightcraft, a small free-flying micro-vehicle that is propelled by ablation. For ALP lightcraft we use a subscale thin shell of nickel replicated over a diamond turned mandrel that produces a highly polished self-focusing, truncated at the focus parabolic mirror. The mass of the lightcraft is 54 mg and it is driven by 100-ps wide, 35-mJ laser pulses at 532 nm wavelength. This is an ongoing research. We also present the latest work on laserdriven micro-thrusters and detail some the near term goals of our program.

Herren, Kenneth A.↗

Photon-Counting Multikilohertz Microlaser Altimeters for Airborne and Spaceborne Topographic Measurements

We consider the optimum design of photon-counting microlaser altimeters operating from airborne and spaceborne platforms under both day and night conditions. Extremely compact Q-switched microlaser transmitters produce trains of low energy pulses at multi-kHz rates and can easily generate subnanosecond pulse-widths for precise ranging. To guide the design, we have modeled the solar noise background and developed simple algorithms, based on Post-Detection Poisson Filtering (PDPF), to optimally extract the weak altimeter signal from a high noise background during daytime operations. Practical technology issues, such as detector and/or receiver dead times, have also been considered in the analysis. We describe an airborne prototype, being developed under NASA's instrument Incubator Program, which is designed to operate at a 10 kHz rate from aircraft cruise altitudes up to 12 km with laser pulse energies on the order of a few microjoules. We also analyze a compact and power efficient system designed to operate from Mars orbit at an altitude of 300 km and sample the Martian surface at rates up to 4.3 kHz using a 1 watt laser transmitter and an 18 cm telescope. This yields a Power-Aperture Product of 0.24 W-square meter, corresponding to a value almost 4 times smaller than the Mars Orbiting Laser Altimeter (0. 88W-square meter), yet the sampling rate is roughly 400 times greater (4 kHz vs 10 Hz) Relative to conventional high power laser altimeters, advantages of photon-counting laser altimeters include: (1) a more efficient use of available laser photons providing up to two orders of magnitude greater surface sampling rates for a given laser power-telescope aperture product; (2) a simultaneous two order of magnitude reduction in the volume, cost and weight of the telescope system; (3) the unique ability to spatially resolve the source of the surface return in a photon counting mode through the use of pixellated or imaging detectors; and (4) improved vertical and transverse spatial resolution resulting from both (1) and (3). Furthermore, because of significantly lower laser pulse energies, the microaltimeter is inherently more eyesafe to observers on the ground and less prone to internal optical damage, which can terminate a space mission prematurely.

Degnan, John J.↗

On-Orbit Radiometric Performance on ICESat-2

NASA’s ICESat-2 mission measures Earth’s elevation with the Advanced Topographic Laser Altimeter System (ATLAS), a 6-beam photon-counting laser altimeter. The Global Geolocated Photon data product (ATL03) is the primary source of photon information used by surface-type-specific higher-level products, along with the Atmospheric Layer Characteristics product (ATL09). ATL03 provides time-tagged, geolocated photon heights referenced to the ellipsoid and a parameter providing an initial classification of photon events as signal or background. We use this classification to evaluate ATLAS radiometry (number of signal photons per transmitted laser pulse) over short time scales and over the mission to date. The radiometric performance of ATLAS will in part determine what differences in the signal and background photon rates are significant and indicate geophysical, rather than instrumental, changes. We find the ATLAS radiometry is very stable over short time scales and exhibits a long-term decrease of ∼1 signal photon per laser pulse (∼-12%) in the strong spots over the first 1.5 years of the mission.

Aimee Gibbons↗

The Mercury Laser Altimeter Instrument for the MESSENGER Mission

The Mercury Laser Altimeter (MLA) is one of the payload science instruments on the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) mission, which launched on 3 August 2004. The altimeter will measure the round trip time-of-flight of transmitted laser pulses reflected from the surface of the planet that, in combination with the spacecraft orbit position and pointing data, gives a high-precision measurement of surface topography referenced to Mercury's center of mass. The altimeter measurements will be used to determine the planet's forced librations by tracking the motion of large-scale topographic features as a function of time. MLA's laser pulse energy monitor and the echo pulse energy estimate will provide an active measurement of the surface reflectivity at 1064 nm. This paper describes the instrument design, prelaunch testing, calibration, and results of post-launch testing.

Cavanaugh, John F.↗

Application of optical correlation techniques to particle imaging velocimetry

Pulsed laser sheet velocimetry yields nonintrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usually MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the partical image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.

Wernet, Mark P.↗