Search NASASearch

SEARCH · Search NASA

Results for “Li-Ion Batteries”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

559 records · Page 19

Air Force standards for nickel hydrogen battery

The topics discussed are presented in viewgraph form and include Air Force nickel hydrogen standardization goals, philosophy, project outline, cell level standardization, battery level standardization, and schedule.

Hwang, Warren

Ni-cd Battery Life Expectancy in Geosynchronous Orbit

The feasibility of using nickel cadmium batteries as an alternate if flight qualified NiH2 batteries are not available is explored. Battery life expectancy data being a key element of power system design, an attempt is made to review the literature, life test data and in orbit performance data to develop an up to date estimate of life expectancy for NiCd batteries in a geosynchronous orbit.

Broderick, R. J.

Orbiting Solar Observatory Battery and Power Design

The OSO-1 represents a recent vintage satellite, or more recent design satellite. A summary of the battery design used on OSO-1 is presented. The temperature effects on voltage and charging-discharging of the battery system are discussed.

F E Ford

Hubble Space Telescope: Battery Capacity Trend Studies

Battery cell wear out mechanisms and signatures are examined and compared to orbital data from the six on-orbit Hubble Space Telescope (HST) batteries, and the Flight Spare Battery (FSB) Test Bed at Marshall Space Flight Center (MSFC), which is instrumented with individual cell voltage monitoring. Capacity trend data is presented which suggests HST battery replacement is required in 2005-2007 or sooner.

Rao, M. Gopalakrishna

Does the International Space Station Leak DNA? Preliminary Results from the ISS External Microorganisms Payload

Existing crewed spacecraft like the ISS (International Space Station) leak by design. The ISS routinely releases gas to maintain life support systems and when astronauts exit the station to perform space walks. The chemical component of this leakage is well characterized, but the biological components are not. The ISS is not subject to planetary protection requirements, but planned missions to Mars will use similar systems and will be subject to planetary protection requirements. If detectable microorganisms are escaping through vents and or airlocks we may need to redesign our crewed habitats to minimize this type of contamination. To test the hypothesis that microorganisms from inside ISS are detectable on exterior surfaces an astronaut used the ISS External Microorganisms sampling kit (Rucker et al. 2018) to sample exterior surfaces of the ISS during an EVA (Extra Vehicular Activity) in January of 2025. These samples were returned to Earth for DNA extraction and sequencing. We successfully, extracted and sequenced bacterial, fungal and viral DNA from these samples that was not present in the negative controls. These results should help NASA refine the planetary protection requirements for crewed missions. Methods: The samples were collected using sterile, DNA free, buccal swabs (23 mm. diameter) housed in custom canisters. Each canister uses a 0.2 μm Teflon filter to maintain sterility as the caddy, holding 8 swabs moves in and out of vacuum. The astronaut sampled the: 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the Carbon Dioxide Removal Assembly vent, and 6) the Vacuum Exhaust System vent. The seventh swab was exposed to vacuum during the EVA without touching it to a surface. The eighth swab, a negative control, was not opened until the caddy returned to Earth. DNA was extracted from the swabs using a QIamp UCP Pathogen kit and prepared for sequencing on an Aviti (Element Biosciences) sequencer (Arslan et al. 2024). The resulting sequences were analyzed using the EDGE Bioinformatics platform (Li et al. 2017). The sequences were analyzed individually using tools like BLAST, GOTTCHA2, Kraken2, and PanGIA. The data were also assembled into metagenome assembled genomes) using tools like CONCOCT, MaxBin2 and MetaBAT2. Results: We successfully extracted and sequenced bacterial, archaeal, fungal and viral DNA from all seven samples. The handrail swab had the lowest number of reads (768,651) and the airlock thermal cover had the highest number of reads (8,819,230). These samples contain DNA from human associated bacteria (e.g. Crynebacterium riegelii ), fungi (.e.g. Penicillium rubens ), and viruses (e.g Alphapapillomavirus ). Conclusion: Preliminary interpretation suggest that the airlock and the space suits themselves are the largest sources of contaminant DNA. Most if not all of the DNA is from organisms known to be present inside the ISS. Vents attached to life support systems may be a lesser source of biological contamination. Further analysis should help NASA address planetary protection knowledge gaps for crewed missions.

Aaron B Regberg

Parametric tests of a 40-Ah bipolar nickel-hydrogen battery

A series of tests were performed to characterize battery performance relating to certain operating parameters which include charge current, discharge current, temperature, and pressure. The parameters were varied to confirm battery design concepts and to determine optimal operating conditions.

Cataldo, R. L.

EMU Battery/module Service Tool Characterization Study

The power tool which will be used to replace the attitude control system in the SMM spacecraft is being modified to operate from a self contained battery. The extravehicular mobility unit (EMU) battery, a silver zinc battery, was tested for the power tool application. The results obtained during show the EMU battery is capable of operating the power tool within the pulse current range of 2.0 to 15.0 amperes and battery temperature range of -10 to 40 degrees Celsius.

Palandati, C. F.

Online Prediction of Battery Discharge and Estimation of Parasitic Loads for an Electric Aircraft

Predicting whether or not vehicle batteries contain sufficient charge to support operations over the remainder of a given flight plan is critical for electric aircraft. This paper describes an approach for identifying upper and lower uncertainty bounds on predictions that aircraft batteries will continue to meet output power and voltage requirements over the remainder of a flight plan. Battery discharge prediction is considered here in terms of the following components; (i) online battery state of charge estimation; (ii) prediction of future battery power demand as a function of an aircraft flight plan; (iii) online estimation of additional parasitic battery loads; and finally, (iv) estimation of flight plan safety. Substantial uncertainty is considered to be an irremovable part of the battery discharge prediction problem. However, high-confidence estimates of flight plan safety or lack of safety are shown to be generated from even highly uncertain prognostic predictions.

Battery Discharge Prediction

Marshall Space Flight Center battery activity

The topics covered are presented in viewgraph form and include a flight program history and in-house activities. Some of the in-house activities addressed include secondary battery/cell testing and Hubble Space Telescope Test data updates involving the NiCd type 40 test - battery 1 and 2, the NiCd type 41 test battery, the general electric battery, the NiCd six-battery system, the six four-cell packs, fourteen-cell pack, three four-cell packs, the NiH2 six-battery system, and the flight spare battery. A general test data update is also presented for the twelve-cell pack, the four four-cell packs, the reconditioning test, and planned Ni-MH testing.

Lowery, Eric

Crewed Space Vehicle Battery Safety Requirements Revision D

The Crewed Space Vehicle Battery Safety Requirements document has been prepared for use by designers of battery-powered vehicles, portable equipment, and experiments intended for crewed spaceflight. The purpose of the requirements document is to provide battery designers with information on design provisions to be incorporated in and around the battery and on the verification to be undertaken to demonstrate a safe battery is provided. The term "safe battery" means that the battery is safe for ground personnel and crew members to handle and use; safe to be used in the enclosed environment of a crewed space vehicle; and safe to be mounted or used in unpressurized spaces adjacent to habitable areas. Battery design review, approval, and certification is required before the batteries can be used for ground operations and be certified for flight.

Russell, Samuel

Eutelsat 2: SAR-10009 nickel-hydrogen battery

The topics are presented in viewgraph form and include SAR-10009 design features, specific energy, analyses and testing, redundant structural insulation, electronics, corrosion protection, battery cell life cycle tests, and spacecraft launches.

Miller, Lee

High-energy, high-power, long-life battery

High-energy-density primary battery achieves energy densities of up to 130 watt hrs./lb. The electrochemical couple consists of a lithium anode, a copper-fluoride cathode, and uses methyl formate/lithium hexafluoroarsenate for the electrolyte. Once achieved, battery life is approximately 30 hours.

Abens, S. G.

Improved silver-zinc battery-terminal seals

Development of battery terminal seal for sealing electrolyte for periods of three to five years is discussed. Operating conditions of battery are defined. Components of electrolyte seal and method of production are reported. Schematic diagrams of device are included.

Snider, W. E.

Development of a battery status monitor

A prototype battery status monitor system has been developed. The functions of the system are: (1) to provide the energy status of the battery, (2) to measure and transmit basic battery parameters, (3) to process these measurements required to determine abnormal functioning of the battery, and (4) to transmit warning signals of the abnormal condition along with a go/no go signal. The system was developed for use with the space shuttle.

Zimmerman, R. I.

General Electric 20-ampere hour nickel-cadmium battery

The interaction, effect, and controllability of the performance parameters of the General Electric 20-ampere-hour, 24-cell nickel cadmium battery are investigated. The battery was cycled under simulated orbit conditions. The acquired data was analyzed and evaluated in terms of battery parameters and performance characteristics. Conclusions and tests results are presented along with recommendations for further study.

Kirsch, W. W.

Pressure Switch Is a Low Cost Battery Indicator

Conventional pressure switch, fabricated by printed-circuit manufacturing techniques, can indicate when charge on battery departs from preset level. Membrane on switch is exposed to internal pressure of battery, which varies according to stored charge. When pressure varies from preset level, switch can turn on a light-emitting diode or similar indicator to warn user that battery is low.

Abita, J. L.

International Ultraviolet Explorer (IUE) spacecraft battery performance update

January 26, 1987 marks the ninth inflight aniversary of the IUE spacecraft, launched into an eccentric synchronous orbit. The orbital path has subjected the spacecraft to 18 solar eclipse seasons since launch. Nine years of inflight operations culminate a major milestone for battery support to a spacecraft, which is well in excess of the initial 3 year design life. A brief outline of events, power system characteristics, and papers presented a previous battery workshops are provided. The IUE battery cell performance is excellent with the exception of the third electrode anomaly and temperature delta between batteries. Data indicates that battery depth-of-discharge (DOD) may be more critical to extend battery life than small operational temperature deltas between batteries. It is predicted that several additional years of battery life may be obtained by a reduction in operational battery DOD.

Tiller, Smith E.