Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Analysis and testing of large space structures

Considerations and approaches to the ground testing of large space structures are discussed. The large size combined with the loading due to gravity makes testing of the complete structure difficult. Gravitational stiffening, suspension effects, virtual air mass, preloads, and air damping alter the dynamic characteristics. Low resonant frequencies and high modal densities within the frequency range of interest combine with small motions and accelerations to make testing difficult. Mechanism complexities and nonlinearities associated with space-erected/assembled structures cause structural complexity regardless of other considerations. Ground test approaches include scale models, element and substructure tests, and structural linearization. Analytical approaches are also discussed.

Stahle, C. V.↗

Beam Non-Uniformity Characterization at the SpinQuest and DarkQuest Experiments

The SpinQuest experiment, including upgrades to SpinQuest designed to increase sensitivity to dark sector searches (commonly known as DarkQuest), utilizes the high-intensity 120 GeV proton beam delivered by the Fermilab Accelerator Complex to probe the inner structure of nucleons and search for new physics beyond the Standard Model. The SpinQuest beam is extracted from the Main Injector synchrotron at Fermilab in what is known as a slow spill . The slow spill involves a complex non-linear half-integer extraction method, which results in non-uniform beam behavior. SpinQuest observes spikes of very high intensity beam which can saturate detectors and reduce trigger efficiency, significantly impacting the experiment's sensitivity. In this project we address this challenge by developing an analysis framework to characterize the beam delivered to SpinQuest. By discovering trends within each spill and by comparing thousands of spills, we can better inform the Accelerator Division and improve the slow spill extraction. We have also begun a collaboration with the Accelerator Division in order to simulate the slow spill and improve the magnet ramp process controls which will improve the uniformity of the beam. These improvements will directly enhance the physics reach of SpinQuest/DarkQuest, increasing their sensitivity to key measurements such as the Sivers function and searches for new physics.

Dolen, James William [Purdue U., Calumet] (ORCID:0↗

High Gradient Accelerator Research

The goal of the MIT program of research on high gradient acceleration is the development of advanced acceleration concepts that lead to a practical and affordable next generation linear collider at the TeV energy level. Other applications, which are more near-term, include accelerators for materials processing; medicine; defense; mining; security; and inspection. The specific goals of the MIT program are: • Pioneering theoretical research on advanced structures for high gradient acceleration, including photonic structures and metamaterial structures; evaluation of the wakefields in these advanced structures • Experimental research to demonstrate the properties of advanced structures both in low-power microwave cold test and high-power, high-gradient test at megawatt power levels • Experimental research on microwave breakdown at high gradient including studies of breakdown phenomena induced by RF electric fields and RF magnetic fields; development of new diagnostics of the breakdown process • Theoretical research on the physics and engineering features of RF vacuum breakdown • Maintaining and improving the Haimson / MIT 17 GHz accelerator, the highest frequency operational accelerator in the world, a unique facility for accelerator research • Providing the Haimson / MIT 17 GHz accelerator facility as a facility for outside users • Active participation in the US DOE program of High Gradient Collaboration, including joint work with SLAC and with Los Alamos National Laboratory; participation of MIT students in research at the national laboratories • Training the next generation of Ph. D. students in the field of accelerator physics.

43 PARTICLE ACCELERATORS↗

Comparison of large-scale structures and velocities in the local universe

Comparison of the large-scale density and velocity fields in the local universe shows detailed agreement, strengthening the standard paradigm of the gravitational origin of these structures. Quantitative analysis can determine the cosmological density parameter, Omega, and biasing factor, b; there is virtually no sensitivity in any local analyses to the cosmologial constant, lambda. Comparison of the dipole anisotropy of the cosmic microwave background with the acceleration due to the Infrared Astronomy Satellite (IRAS) galaxies puts the linear growth factor in the range beta approximately equals Omega (exp 0.6)/b = 0.6(+0.7/-0.3) (95% confidence). A direct comparison of the density and velocity fields of nearby galaxies gives beta = 1.3 (+0.7/-0.6), and from nonlinear analysis the weaker limit (Omega greater than 0.45 for b greater than 0.5 (again 95% confidence). A tighter limit (Omega greater than 0.3 (4-6 sigma)), is obtained by a reconstruction of the probability distribution function of the initial fluctuations from which the structures observed today arose. The last two methods depend critically on the smooth velocity field determined from the observed velocities of nearby galaxies by the POTENT method. A new analysis of these velocities, with more than three times the data used to obtain the above quoted results, is now underway and promises to tighten the uncertainties considerably, as well as reduce systematic bias.

Yahil, Amos↗

Design Features of a Planar Hybrid/Permanent Magnet Strong Focusing Undulator for Free Electron Laser (FEL) And Synchrotron Radiation (SR) Applications

Insertion devices for Angstrom-wavelength Free Electron Laser (FEL) amplifiers driven by multi-GeV electron beams generally require distributed focusing substantially stronger than their own natural focusing fields. Over the last several years a wide variety of focusing schemes and configurations have been proposed for undulators of this class, ranging from conventional current-driven quadrupoles external to the undulator magnets to permanent magnet (PM) lattices inserted into the insertion device gap. In this paper we present design studies of a flexible high-field hybrid/PM undulator with strong superimposed planar PM focusing proposed for a 1.5 Angstrom Linac Coherent Light Source (LCLS) driven by an electron beam with a 1 mm-mr normalized emittance. Attainable field parameters, tuning modes, and potential applications of the proposed structure are discussed.

43 PARTICLE ACCELERATORS↗

Wakefield Simulations for the Laser Acceleration Experiment at SLAC

Laser-driven acceleration in dielectric photonic band gap structures can provide gradients on the order of GeV/m. The small transverse dimension of the structure, on the order of the laser wavelength, presents interesting wakefield-related issues. Higher order modes can seriously degrade beam quality, and a detailed understanding is needed to mitigate such effects. On the other hand, wakefields also provide a direct way to probe the interaction of a relativistic bunch with the synchronous modes supported by the structure. Simulation studies have been carried out as part of the effort to understand the impact on beam dynamics, and to compare with data from beam experiments designed to characterize candidate structures. In this paper, we present simulation results of wakefields excited by a sub-wavelength bunch in optical photonic band gap structures.

36 MATERIALS SCIENCE↗

Accelerated Cartesian expansions for the rapid solution of periodic multiscale problems

We present an algorithm for the fast and efficient solution of integral equations that arise in the analysis of scattering from periodic arrays of PEC objects, such as multiband frequency selective surfaces (FSS) or metamaterial structures. Our approach relies upon the method of Accelerated Cartesian Expansions (ACE) to rapidly evaluate the requisite potential integrals. ACE is analogous to FMM in that it can be used to accelerate the matrix vector product used in the solution of systems discretized using MoM. Here, ACE provides linear scaling in both CPU time and memory. Details regarding the implementation of this method within the context of periodic systems are provided, as well as results that establish error convergence and scalability. In addition, we also demonstrate the applicability of this algorithm by studying several exemplary electrically dense systems.

97 MATHEMATICS AND COMPUTING↗

Radiotherapy and Nuclear Medicine Project for an Integral Oncology Center at the Oaxaca High Specialization Regional Hospital

A building project of Radiotherapy and Nuclear Medicine services (diagnostic and therapy), within an Integral Oncology Center (IOC), requires interdisciplinary participation of architects, biomedical engineers, radiation oncologists and medical physicists. This report focus on the medical physicist role in designing, building and commissioning stages, for the final clinical use of an IOC at the Oaxaca High Specialization Regional Hospital (HRAEO). As a first step, during design stage, the medical physicist participates in discussions about radiation safety and regulatory requirements for the National Regulatory Agency (called CNSNS in Mexico). Medical physicists propose solutions to clinical needs and take decisions about installing medical equipment, in order to fulfill technical and medical requirements. As a second step, during the construction stage, medical physicists keep an eye on building materials and structural specifications. Meanwhile, regulatory documentation must be sent to CNSNS. This documentation compiles information about medical equipment, radioactivity facility, radiation workers and nuclear material data, in order to obtain the license for the linear accelerator, brachytherapy and nuclear medicine facilities. As a final step, after equipment installation, the commissioning stage takes place. As the conclusion, we show that medical physicists are essentials in order to fulfill with Mexican regulatory requirements in medical facilities.

07 ISOTOPE AND RADIATION SOURCES↗

Direct geometric probe of singularities in band structure

A quantum system’s energy landscape may have points where multiple energy surfaces are degenerate and that exhibit singular geometry of the wave function manifold, with major consequences for the system’s properties. Ultracold atoms in optical lattices have been used to indirectly characterize such points in the band structure. Here we measured the non-Abelian transformation produced by transport directly through the singularities. We accelerated atoms along a quasi-momentum trajectory that enters, turns, and then exits the singularities at linear and quadratic band-touching points of a honeycomb lattice. Measurements after transport identified the topological winding numbers of these singularities to be 1 and 2, respectively. Our work introduces a distinct method for probing singularities that enables the study of non-Dirac singularities in ultracold-atom quantum simulators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of the Eigen-Emittance Concept to Design Ultra-Bright Electron Beams

Using correlations at the cathode to tailor a beam's eigen-emittances is a recent concept made useful by the symplectic nature of Hamiltonian systems such as beams in accelerators. While introducing correlations does not change the overall 6-dimensional phase space volume, it can change the partitioning of this volume into the longitudinal and two transverse emittances, which become these eigen-emittances if all the initial correlations are unwound and removed. In principle, this technique can be used to generate beams with highly asymmetric emittances, such as those needed for the next generation of very hard X-ray free-electron lasers. This approach is based on linear correlations, and its applicability will be limited by the magnitude of nonlinear effects in photoinjectors which will lead to mixing in phase space that cannot be unwound downstream. Here, we review the eigen-emittance concept and present a linear eigen-emittance design leading to a highly partitioned, and transverse ultra-bright, electron beam. We also present numerical tools to examine the evolution of the eigen-emittances in realistic accelerator structures and results indicating how much partitioning is practical.

Accelerator Design, Technology, and Operations↗

Reduction of Pertechnetate By Acetohydroxamic Acid: Formation of [tc**II(NO)(AHA)(2)(H(2)O)]**+ And Implications for the UREX Process

Reductive nitrosylation and complexation of ammonium pertechnetate by acetohydroxamic acid has been achieved in aqueous nitric and perchloric acid solutions. The kinetics of the reaction depend on the relative concentrations of the reaction components and are accelerated at higher temperatures. The reaction does not occur unless conditions are acidic. Analysis of the X-ray absorption fine structure spectroscopic data is consistent with a pseudo-octahedral geometry and the linear Tc-N-O bond typical of technetium nitrosyl compounds, and electron spin resonance spectroscopy is consistent with a d{sup 5} Tc(II) nitrosyl complex. The nitrosyl source is generally AHA, but it may be augmented by some products of the reaction with nitric acid. The resulting low-valency trans-aquonitrosyl(diacetohydroxamic)-technetium(II) complex ([Tc{sup II}(NO)(AHA){sub 2}H{sub 2}O]{sup +}, 1) is highly soluble in water, extremely hydrophilic, and is not extracted by tri-n-butylphosphate in a dodecane diluent. Its extraction properties are not pH-dependent: potentiometric-spectrophotometric titration studies indicate a single species from pH 4 down to -0.6 (calculated). This molecule is resistant to oxidation by H{sub 2}O{sub 2}, even at high pH, and can undergo substitution to form other technetium nitrosyl complexes. The potential formation of 1 during reprocessing may strongly impact the fate of technetium in the nuclear fuel cycle.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nonlinear Dynamic Analyses of STS-1 Forward RCS Oxidizer Tank Structural Failure

At liftoff of the first Space Shuttle mission, a strong ignition overpressure pulse excited the stack. The frequency of the experienced pressure wave exceeded pre-launch predictions, and resulted in high, alternating normal accelerations along the length of the vehicle. As result of this unexpected loading, an oxidizer tank support strut in the orbiter’s forward reaction control system module failed in buckling under axial compression, which could have led to loss of the mission, crew, and vehicle. This incident is investigated in more detail using linear and nonlinear finite element analyses, complementing previous analyses with classical structural mechanics. The results of these analyses are examined to provide additional insight into the accident and to better inform future design decisions for modern space vehicle systems and structures.

Space Shuttle↗

Nonlinear Dynamic Analyses of STS-1 Forward RCS Oxidizer Tank Structural Failure

At liftoff of the first Space Shuttle mission, a strong ignition overpressure pulse excited the stack. The frequency of the experienced pressure wave exceeded pre-launch predictions, and resulted in high, alternating normal accelerations along the length of the vehicle. As result of this unexpected loading, an oxidizer tank support strut in the orbiter’s forward reaction control system module failed in buckling under axial compression, which could have led to loss of the mission, crew, and vehicle. This incident is investigated in more detail using linear and nonlinear finite element analyses, complementing previous analyses with classical structural mechanics. The results of these analyses are examined to provide additional insight into the accident and to better inform future design decisions for modern space vehicle systems and structures.

Space Shuttle↗

BiFeO(3): Synchrotron Radiation Structure Refinement And Magnetoelectric Geometry

Presently BiFeO{sub 3} focuses attention due to its multiferroic nature. This phase shows a highly distorted perovskite crystal structure, with R3c crystal symmetry. Details of the crystallographic structure are required input for a detailed explanation of its remarkable magnetoelectric properties. Present report contributes a high-resolution synchrotron radiation diffraction analysis of the BiFeO{sub 3} crystal structure. Single-phased sample was obtained by conventional solid-state reaction under bismuth atmosphere. XRD experiment was performed on beamline 2-1, Stanford Synchrotron Radiation Laboratory, with 12 keV X-rays. For data Rietveld processing, Fullprof software package was applied. Obtained cell parameters (in {angstrom}, hexagonal system description) were a = 5.57414(4); c = 13.85882(12). Group-theoretical analysis of BiFeO{sub 3} linear magnetoelectric tensor is presented. Only transverse effect is allowed by symmetry. Axial-symmetry polycrystal ceramics cannot show linear magnetoelectric coupling.

36 MATERIALS SCIENCE↗

GPU acceleration of all-electron electronic structure theory using localized numeric atom-centered basis functions

We present an implementation of all-electron density-functional theory for massively parallel GPU-based platforms, using localized atom-centered basis functions and real-space integration grids. Special attention is paid to domain decomposition of the problem on non-uniform grids, which enables compute- and memory-parallel execution across thousands of nodes for real-space operations, e.g. the update of the electron density, the integration of the real-space Hamiltonian matrix, and calculation of Pulay forces. To assess the performance of our GPU implementation, we performed benchmarks on three different architectures using a 103-material test set. We find that operations which rely on dense serial linear algebra show dramatic speedups from GPU acceleration: in particular, SCF iterations including force and stress calculations exhibit speedups ranging from 4.5 to 6.6. For the architectures and problem types investigated here, this translates to an expected overall speedup between 3–4 for the entire calculation (including non-GPU accelerated parts), for problems featuring several tens to hundreds of atoms. Additional calculations for a 375-atom Bi2Se3 bilayer show that the present GPU strategy scales for large-scale distributed-parallel simulations.

42 ENGINEERING↗

Quark-Hadron Duality in Neutron Spin-Structure and g{sub 2} moments at intermediate Q{sup 2}

Jefferson Lab experiment E01-012 measured the {sup 3}He spin-structure functions and virtual photon asymmetries in the resonance region in the momentum transfer range 1.0<Q{sup 2}<4.0 (GeV/c){sup 2}. Our data, when compared with existing deep inelastic scattering data, were used to test quark-hadron duality in g{sub 1} and A{sub 1} for {sup 3}He and the neutron. In addition, preliminary results on the {sup 3}He spin-structure function g{sub 2}, on the Burkhardt-Cottingham sum rule and on higher twist effects through the x{sup 2}-weighted moment d{sub 2} of the neutron were presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

Parity-Violating PVDIS with SoLID

We are planning an experiment at JLab to measure parity-violation in deep inelastic scattering to high precision over a broad kinematic range. The goal of the experiment is to test the Standard Model, search for charge symmetry violation at the quark level, and to search for higher twist effects due to quark-quark interactions. We will also be able to measure the d/u ratio for the nucleon and search for nuclear effects in deep inelastic scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗