Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

Characterisation of the current switch mechanism in two-stage wire array Z-pinches

In this paper, we describe the operation of a two-stage wire array z-pinch driven by the 1.4 MA, 240 ns rise-time Magpie pulsed-power device at Imperial College London. In this setup, an inverse wire array acts as a fast current switch, delivering a current pre-pulse into a cylindrical load wire array, before rapidly switching the majority of the generator current into the load after a 100–150 ns dwell time. A detailed analysis of the evolution of the load array during the pre-pulse is presented. Measurements of the load resistivity and energy deposition suggest significant bulk heating of the array mass occurs. The ∼5 kA pre-pulse delivers ∼0.8 J of energy to the load, leaving it in a mixed, predominantly liquid-vapour state. The main current switch occurs as the inverse array begins to explode and plasma expands into the load region. Electrical and imaging diagnostics indicate that the main current switch may evolve in part as a plasma flow switch, driven by the expansion of a magnetic cavity and plasma bubble along the length of the load array. Analysis of implosion trajectories suggests that approximately 1 MA switches into the load in 100 ns, corresponding to a doubling of the generator dI/dt. Potential scaling of the device to higher current machines is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Maximum Cs-137 Curie Loading onto Crystalline Silicotitanate for the Documented Safety Analysis of the Tank Side Cesium Removal Platform

The Tank Side Cesium Removal (TSCR) system is currently being constructed to process Hanford tank waste supernates for vitrification. TSCR incorporates a filtration system and cesium (Cs) removal system using columns filled with crystalline silicotitanate (CST) ion exchanger, produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for TSCR limits a single column curie loading to 141,600 Ci; given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of a TSCR column, this equates to 0.10 mmole Cs per g CST. Factors that influence 137Cs loading onto the CST include, but are not limited to, CST production lot (different production lots behave differently), contact temperature, contact duration, 137Cs mass fraction, and competitors in the tank waste feed. Seventeen tank waste feeds (compositions) were identified by Washington River Protection Solutions to be processed through TSCR. These feed compositions were used to develop a simulant (referred to herein as Stage 1) that would provide an upper bound to the Cs loading onto CST based on maximizing the Cs/Na activity coefficient ratios in solution while maintaining Na at no less than 5.0 M. Building upon this Stage 1 simulant, a series of four additional simulants were developed based on the cationic/anionic species that impact Cs exchange, with each successive formulation relaxing one or more matrix component concentration constraints as show in Table S.1

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two-way Coupling of Presto v2.8 and CTH v8.1

A loose two-way coupling of SNL's Presto v2.8 and CTH v8.1 analysis code has been developed to support the analysis of explosive loading of structures. Presto is a Lagrangian, three-dimensional explicit, transient dynamics code in the SIERRA mechanics suite for the analysis of structures subjected to impact-like loads. CTH is a hydro code for modeling complex multi-dimensional, multi-material problems that are characterized by large deformations and/or strong shocks. A fundamental assumption in this loose coupling is that the compliance of the structure modeled with Presto is significantly smaller than the compliance of the surrounding medium (e.g. air) modeled with CTH. A current limitation of the coupled code is that the interaction between CTH and thin structures modeled in Presto (e.g. shells) is not supported. Research is in progress to relax this thin-structure limitation.

99 GENERAL AND MISCELLANEOUS↗

Analysis Of The Interface Behavior Under Cyclic Loading

This paper analyses the frictional behavior between soil and structures under cyclic loading conditions. In particular, the attention is focused on the stress degradation occurring in sand-metal interface tests and on the relevant parameters playing a role in such kind of tests. Also, the paper reports the analysis of the experimental data from the constitutive point of view with a two-surface elastoplastic model.

36 MATERIALS SCIENCE↗

Better Building Alliance, Plug and Process Loads in Commercial Buildings: Capacity and Power Requirement Analysis (Brochure)

This brochure addresses gaps in actionable knowledge that can help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. This brochure should be used to make these decisions so systems can operate more energy efficiently; upfront capital costs will also decrease. This information can also be used to drive changes in negotiations about PPL energy demands. It should enable brokers and tenants to agree about lower PPL capacities. Owner-occupied buildings will also benefit. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Aggregation Methods for Quasi-Static Power Flow Analysis on High PV Penetration Feeders

This paper focuses on developing load aggregation methodologies for analyzing quasi-static power flows on high photovoltaic penetrated distribution feeders so statistics of the transformer loading levels, voltage ramping events, and voltage violation events can be properly quantified. A load profile aggregation algorithm is presented to construct 24-hour, minute-by-minute load profiles at each load node on the test feeder so the aggregation of those load profiles matches the load profile measured at the feeder head. A quasi-static power flow analyses are conducted to obtain minute-by-minute power flow results that can be used to quantify transformer overloads and voltage issues in distribution systems. To demonstrate the effectiveness of the developed methodology, the IEEE-123 test feeder model and residential load profiles collected from the PECAN street project are used in the case studies. Simulation results show that the method is effective in producing the required operation statistics.

Load aggregaton, PV integration, quasi-static powe↗

Iodine capture with mechanically robust heat-treated Ag-Al-Si-O xerogel sorbents

Silver-loaded heat-treated aluminosilicate xerogels (Ag-HTX) were evaluated as sorbents for iodine [I2(g)] capture. The heat treatment step was performed to help increase the mechanical integrity of the gels. The synthesized xerogels were characterized using powder X-ray diffraction, scanning electron microscopy, energy-dispersive X-ray spectroscopy, transmission electron microscopy, Brunauer-Emmett-Teller analysis, gravimetric iodine loading, nanoindentation, and dynamic mechanical analysis. The structural and chemical analyses of Ag-HTX showed uniform distribution of Ag throughout the gel network after Ag-exchange. After I2(g) capture, the AgI crystallites were observed in the sorbent verifying chemisorption as the iodine capture mechanism. Iodine loading of this xerogel was 0.43 g g-1 at 150°C over 1 d and 0.52 g g-1 at 22°C over 33 d. The specific surface area of Ag-HTX was 202 m2 g-1 and decreased to 87 m2 g-1 after iodine loading. The hardness of the heat-treated xerogel was 160 times higher than heat-treated aerogel of the same composition. The heat-treatment process increased the modulus value to 40.77 MPa from 6.99 MPa of as-made xerogel, demonstrating the need for this added step in the synthesis process. These results show that Ag-HTX is a promising sorbent for I2(g) capture with good loading capacity and mechanical stability.

xerogels, aerogels, iodine capture, hardness testi↗

Fitness-for-Service Analysis of Reactor Components under Flexible Load-Following Operating Conditions

Conventional power-generation plants, including nuclear plants, have been traditionally designed to provide a steady baseload energy capacity, optimizing output efficiency while minimizing variable costs. However, the growing adoption of large-scale renewable energy-generation systems, which rely on intermittent sources such as solar and wind, has introduced more variability into the energy supply in interconnected electricity grids. As a result, the next generation of power plants needs to operate in what is known as the load-following mode, requiring flexible adjustments in electricity production to align with the energy demand on the grid. This transition from the steady baseload operation to load-following operating conditions can significantly increase the number of times various plant components are exposed to transient stresses. This increased thermo-mechanical cycling can lead to accelerated material degradation, thereby elevating the risk of premature failure of a component. It becomes imperative to conduct a comprehensive analysis of fatigue, creep-fatigue, and stress corrosion cracking life, to assess the resilience of the various engineering components under these flexible load-following operating conditions. This study aims to develop a comprehensive numerical model of a light-water reactor pressure vessel (RPV) to investigate its degradation under various operating scenarios. This coupled thermo-mechanical finite element analysis evaluated the stress response of the RPV caused by considering fluctuations in thermal and mechanical loads caused by the varying pressure and temperature occurring during the load-following operation. Critical locations on the RPV are subsequently identified based on the stress response. The stress intensity factors for the postulated flaws at those locations are then calculated, followed by an evaluation of the reactor's life in accordance with the ASME Boiler and Pressure Vessel Code Section XI. This comprehensive life assessment covers a number of transients expected during the flexible load-following operation, providing invaluable insights into the RPV's structural integrity. Moreover, the development methodology can be adapted to other reactor components, as well as components of conventional power stations that are affected by varying operating conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders

This paper focuses on developing a two-step load disaggregation method for conducting quasi-static time-series analysis using actual distribution feeder data. This can help utilities conduct power flow studies using smart meter measurements to assess the impact of high penetration of distributed energy resources. In the first step, load profiles of residential and commercial buildings obtained from smart meter data are used to match the load profile at the feeder head. This step will determine the number of residential and commercial loads on the feeder. The second step is to allocate the selected load profiles to each load node based on its transformer rating. This allows each load node to have its own load profile and the aggregation of those nodal load profiles matches closely to the metered feeder load shape at the substation. This algorithm is validated using smart meter data and the SCADA data of a real feeder. We compared the performance of the proposed method with the traditional load allocation method (i.e. use the feeder load shape for all subsequent load nodes scaling by the transformer capacities) when conducting quasi-static power flow studies. Results show that the proposed algorithm matches the utility data well and the obtained voltage profiles reveal more voltage dynamics than using the conventional load allocation method. (PDF) A Two-Step Load Disaggregation Algorithm for Quasi-static Time-series Analysis on Actual Distribution Feeders.

load disaggregation, load shape, quasi-static, tim↗

Rotor Magnet Fault Analysis in Permanent Magnet AC Machines Under Load Conditions - All Electric Transportation Systems

This paper studies the performance of a Permanent Magnet (PM) alternating-current (AC) machine when subjected to faults under load conditions. The effect of varying load torques, and unbalances are found to be potential causes of rotor faults, inducing physical magnet defects or broken rotor-PMs. The consequent and immediate impact on the machine quantities is observed through anomalous change in torque-speed characteristics and other vital signatures such as machine back-EMF/flux and motor current signatures (MCS). The present research study develops and illustrates a method to diagnose physical magnet defects (fault) in PMAC machines by estimating the machine torque/back-EMF constant, Ke. The constant Ke is a measure of magnet strength exhibiting the health of rotor PMs, indicative of faults. Advanced research studies and investigations are carried out to establish motor approximations and signature-based analysis as significant viable tools for diagnosing machine faults even under load conditions.

alternating current↗

Multi-scale computational analysis of unidirectional carbon fiber reinforced polymer composites under various loading conditions

In this study, a multi-scale computational analysis based on representative volume element (RVE) modeling and molecular dynamics (MD) simulations is developed to investigate the microscopic failure mechanisms of unidirectional (UD) carbon fiber reinforced polymer (CFRP) composites. The average properties of the 200-nm thickness interphase region between fiber and matrix are characterized through MD simulations and an analytical gradient model. The results demonstrate that the interphase region has higher Young’s modulus and strength, compared to the bulk matrix. This stiffened interphase region influences the composite response significantly. Specifically, the traditional two-phase model with zero-thickness interface fails to capture the stress-strain behavior compared to the experimental data. However, by adding the interphase region to a modified RVE model, the accuracy of simulation results will be improved significantly. Furthermore, a coupled experimental-computational micromechanics approach is adopted to calibrate and validate the cohesive parameters of the interface. By including the cohesive interface, our modified RVE model accurately captures the failure strength of the composites. Finally, different failure mechanisms for specimens are investigated using our multi-scale computational framework. In conclusion, the results show that the failure modes of UD CFRP composites are very complex and multiple failure mechanisms co-exist depending on the loading conditions, agreeing well with our experimental analyses.

36 MATERIALS SCIENCE↗

Integration of Reliability with Mechanistic Thermalhydraulics: Report on Approach and Test Problem Results

The Risk-Informed Safety Margin Characterization (RISMC) pathway of the Light Water Reactor Sustainability Program is developing simulation-based methods and tools for analyzing safety margin from a modern perspective. There are multiple definitions of "margin." One class of definitions defines margin in terms of the distance between a point estimate of a given performance parameter (such as peak clad temperature), and a point-value acceptance criterion defined for that parameter (such as 2200° F). The present perspective on margin is that it relates to the probability of failure, and not just the distance between a nominal operating point and a criterion. In this work, margin is characterized through a probabilistic analysis of the "loads" imposed on systems, structures, and components, and their "capacity" to resist those loads without failing. Given the probabilistic load and capacity spectra, one can assess the probability that load exceeds capacity, leading to component failure. Within the project, we refer to a plot of these probabilistic spectra as "the logo." Refer to Figure 1 for a notional illustration. The implications of referring to "the logo" are (1) RISMC is focused on being able to analyze loads and spectra probabilistically, and (2) calling it "the logo" tacitly acknowledges that it is a highly simplified picture: meaningful analysis of a given component failure mode may require development of probabilistic spectra for multiple physical parameters, and in many practical cases, "load" and "capacity" will not vary independently.

99 GENERAL AND MISCELLANEOUS↗

A Methodology for Loading the Advanced Test Reactor Driver Core for Experiment Analysis

In support of experiments in the ATR, a new methodology was devised for loading the ATR Driver Core. This methodology will replace the existing methodology used by the INL Neutronic Analysis group to analyze experiments. Studied in this paper was the as-run analysis for ATR Cycle 152B, specifically comparing measured lobe powers and eigenvalue calculations.

42 ENGINEERING↗

Assessing the Geomechanical Response of CO 2 Disposal in Flood Basalt Reservoirs

In this work, we complete a multi-scale investigation of the physical processes governing geologic CO 2 sequestration in basalt reservoirs. This work integrates (i) laboratory measurements of relative permeability in a basalt fracture, (ii) theoretical modeling to understand how relative permeability uncertainty affects geomechanical performance attributes of basalt reservoirs, (iii) outcrop-scale simulation to identify the characteristics of vertical CO 2 flow in a basalt fracture network, and (iv) regional-scale assessment of permeability architecture in the Columbia River Basalt Group (CRBG). These individual studies are combined into a site-scale stochastic model of geologic CO 2 sequestration in the Columbia River Plateau, which shows how bulk and relative permeability variability affects geomechanical reservoir integrity and storage capacity of flood basalt reservoirs. This project resulted in a novel laboratory technique that combines X-ray CT and micro-PET scanning to calculate the relative permeability curves for a horizontal fracture in basalt. We also discovered that permeability on the Columbia River Plateau exhibits directionally-dependent spatial correlation, which our analysis suggests is a result of loading-induced subsidence. This analysis further discovered that permeability in the CRBG may increase at depth due to bending moment stresses. In the context of CO 2 sequestration, this result implies that storage capacity and injectivity may actually increase at depths beyond ~1 km. Our outcrop-scale investigation found that buoyant, free-phase CO 2 tends to accumulate at fracture intersections, which inhibits vertical flow over 10+ year timescales and may facilitate both physical and chemical trapping as fluid mobility decreases. At the site-scale, we find that in flood basalt reservoirs the spatial configuration of reservoir permeability exhibits substantial control on CO 2 injectivity. We utilized known borehole geology from the Wallula Basalt Sequestration Pilot Project to develop 50 equally probable permeability configurations and found that a single injection well operating at 95% of the borehole breakout pressure can deliver 0.12 to 2.0 million metric tons of CO 2 per year (MMT CO 2 per year). This maximum injection rate can support a 1,000 MW gas-fired power plant with a single injection well.

58 GEOSCIENCES↗

Design by analysis rules for ASME Section III, Division 5, Class B components

The current rules for elevated temperature ASME Section III, Division 5, Class B components, other than piping, were basically adapted from the Design-by-Rule approach for Section VIII, Division 1 vessels. A goal of the proposed new rules is to explicitly account for the design life and cyclic service while recognizing the less-rigorous requirements commensurate with lesser safety consideration. Further goals are to maximize the use of modern computational technology, for example finite element analysis in conjunction with reference stress concepts, and to avoid the need for stress classification. This paper summarizes the work done to address these issues. A summary of the design-by-analysis for primary loads, strain limit evaluation, and creep-fatigue damage assessment is presented. The proposed design-by-analysis creep-fatigue damage calculation approach uses a new elastic follow-up-based Isochronous Stress Strain Curve stress relaxation procedure. A set of sample problems are selected to validate the proposed design-by-analysis rules for creep-fatigue damage assessment. The proposed Class B rules are evaluated against the Class A elastic design rules and the experimental data obtained from a family of a simplified model test-based key-feature test results. The proposed Class B creep-fatigue damage assessment methodology yields conservative design cycles estimates compared to the experimental results.

36 MATERIALS SCIENCE↗

Analysis of Differential Financial Impacts of LWR Load-Following Operations. Revision 1

This document reports the application of HERON (Holistic Energy Resource Optimization Network), a newly-developed RAVEN (Risk Analysis Virtual ENvironment) plugin for grid and capacity optimization, to a case study conducted in collaboration with Arizona Public Service (APS). The study is a work in progress; this report presents a description of current models and corresponding results for a particular consideration. APS is anticipating several operational challenges. The first is rapid growth of Variable Renewable Energy (VRE) sources such as wind and solar power providing energy to the grid in the APS service region. This creates challenges for baseload operation of the Palo Verde Generating Station (PVGS), a nuclear power plant co-owned and operated by APS. The second challenge for APS is a change in the cooling water acquisition contract with the Sub Regional Operating Group (SROG). The existing contract is expiring soon, and a renewal is only available for a significantly higher price of water. These two challenges represent a difficulty in maintaining profitability for PVGS as local area demand is highly fluctuant and water prices may increase. Furthermore, excess production at PVGS is currently traded on the Palo Verde energy Hub (PVH), which occasionally offers very low or negative locational marginal prices (LMP) for electricity. This analysis considers the potential benefits of occasional curtailment of PVGS as a method to mitigate unprofitable production hours. Similar to load following, optional daily curtailment would allow APS to elect curtailment of PVGS as low as 70% of its nominal operating level between the hours of 08:00 and 16:00 provided local area demand is met and it is profitable to do so. This document reports a stochastic differential analysis of the Net Present Value (NPV) of PVGS as operated by NPS as a result of optional curtailment operation. To model this differential case, HERON has been designed from previous efforts in this study as a generic tool to accelerate the design and execution of RAVEN workflows for technoeconomic analysis of grid energy systems. HERON leverages both RAVEN and the CashFlow plugin for RAVEN to stochastically explore or optimize a response surface with energy grid system production capacities as inputs and mean NPV as a goal function. HERON performs these evaluations by stochastically sampling market, weather, and demand events using RAVEN’s ARMA reduced-order model capability to generate boundary conditions for dispatch optimization. The algorithm performs the dispatch optimization for each of the synthetic scenarios. For this case, HERON designs workflows to simulate behavior of the PVH, wind, solar, and APS local area demand, and use these synthetic scenarios to stochastically evaluate the differential benefit of optional curtailment for each scenario. While this study finds optional curtailment to be a potential source of revenue, the magnitude of the differential NPV is sufficiently small that it is unlikely a priority for increasing the profitability of PVGS. Further, the differential NPV shrinks throughout the simulated years, suggesting the long-term benefit of such operation given current assumptions is negligible.

14 SOLAR ENERGY↗

Design of a 3.4-MW wind turbine with integrated plasma actuator-based load control

Historically, cost reduction in wind energy has been accomplished by increasing hub heights and rotor diameters to capture more energy per turbine. The growth in rotor and turbine costs with increasing turbine sizes is also driven by the additional structure that must be added to withstand unsteady aerodynamic loads caused by turbulence, gusts, wind shear, misaligned yaw, upwind wakes, and the tower shadow. In this paper, we present a holistic design solution to integrate active load control using a controllable Gurney flap based on plasma actuators. We illustrate the design solution for a land-based 3.4-MW wind turbine rotor. Comparisons to a baseline reference 3.4-MW wind turbine show significant load reduction (15–18% DEL reduction for flap-wise blade root moments), rotor mass reduction (5–8%), and LCOE reduction (1.16–3.11%). To achieve these results, a comprehensive sequential-iterative design procedure is introduced to integrate the controllable Gurney flap into the turbine design and to drive the design solution toward the best LCOE reduction solution. Results are presented for mapping fatigue load reductions into cost reductions. In addition, an evaluation of active load control extended from Region-III to also include Region-II showed a further 34% reduction in DEL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗