Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Characteristics of Total Column CO2 Retrievals from the OCO Missions: Biases, Information Content and Implications for Flux Inversions

The Orbiting Carbon Observatory-2 and Orbiting Carbon Observatory-3, launched in 2015 and 2019, respectively, are intended to collect and deliver high-resolution observations of CO2 with unprecedented space and time coverage. Observations of CO2 from these remote-sensing missions (also known as XCO2, or column-based average, dry air mole fraction of CO2) are then used by the global carbon cycle community to answer a wide range of science questions, from the distribution and quantification of global and regional CO2 source-sink patterns to quantification of anthropogenic sources at urban scales. Even though we have had the OCO-2 mission flying for a few years now, the retrieval algorithms are continuously evolving and improving to deliver XCO2 retrievals with very high precision and high accuracy (or low biases). In this presentation, we will discuss a simple yet effective quantitative framework that has been developed by the OCO-2 flux team to evaluate the information content of these XCO2 retrievals as soon as they are released, i.e., with lower latency than full-scale flux inversions. This framework serves as a precursor to advanced inverse modeling frameworks and is intended to provide an early but accurate assessment of the signal present in the satellite retrievals, the robustness of that signal, and the ability of these retrievals to resolve patterns in CO2 surface fluxes that cannot be resolved by our current network of surface sites. Specific results will tackle a tiered set of questions that are being addressed using this framework: (a) what are the distribution of retrievals in the different modes of operation and how do they vary in space and time? (b) what is the information that is being given to the inverse modeling frameworks from the space-based data, information above and beyond what is provided by the in-situ data? and (c) how do these factors influence our choices for doing flux inversions with the satellite retrievals? While the primary focus of the results will be on application of this technique to mature OCO-2 retrievals, we will show early results for a couple of months of OCO-3 retrievals. For the time-period that the retrievals from the two missions overlap, we will highlight how this framework allows us to effortlessly put the information from OCO-3 and OCO-2 on an equal footing, thus enabling easy comparison between the two pioneering missions.

Chatterjee, Abhishek↗

Ground Testing of 2-µm Triple-Pulse IPDA Lidar for Carbon Dioxide and Water Vapor Measuremets

A triple-pulse, 2-µm, Integrated Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center. This active remote sensing instrument provides a technique for measuring atmospheric carbon dioxide and water vapor simultaneously and independently. A 2-µm high-energy pulsed laser is incorporated for the IPDA transmitter, which provides high signal-to-noise ratio measurements using a commercial direct detection system. This results in a high-precision measurement capability for the low troposphere weighted-average column dry-air volume mixing ratio of the gases. Recent IPDA ground testing indicated carbon dioxide and water vapor measurements sensitivities of 8% and 14%, respectively and biases of 0.1%. However, using the R30 centerline position for the on-line enhances the CO2 measurement sensitivity to 0.6%.

Refaat, Tamer F.↗

Fusion Approach for Remotely-Sensed Mapping of Agriculture (FARMA): A Scalable Open Source Method for Land Cover Monitoring Using Data Fusion

The increasing availability of very-high resolution (VHR; <2 m) imagery has the potential to enable agricultural monitoring at increased resolution and cadence, particularly when used in combination with widely available moderate-resolution imagery. However, scaling limitations exist at the regional level due to big data volumes and processing constraints. Here, we demonstrate the Fusion Approach for Remotely-Sensed Mapping of Agriculture (FARMA), using a suite of open source software capable of efficiently characterizing time-series field-scale statistics across large geographical areas at VHR resolution. We provide distinct implementation examples in Vietnam and Senegal to demonstrate the approach using WorldView VHR optical, Sentinel-1 Synthetic Aperture Radar, and Sentinel-2 and Sentinel-3 optical imagery. This distributed software is open source and entirely scalable, enabling large area mapping even with modest computing power. FARMA provides the ability to extract and monitor sub-hectare fields with multisensor raster signals, which previously could only be achieved at scale with large computational resources. Implementing FARMA could enhance predictive yield models by delineating boundaries and tracking productivity of smallholder fields, enabling more precise food security observations in low and lower-middle income countries.

fusion↗

Adapting a Low-Cost and Open-Source Commercial Pipetting Robot for Nanoliter Liquid Handling

Nanoliter liquid handling capabilities in bioanalytical workflows can reduce reagent costs and improve sample processing efficiency. Here we report the successful modification of a low-cost commercially available pipetting robot, the Opentrons 1 (OT1), using inexpensive 3D-printed parts to accommodate low-nanoliter volumes. The pipetting accuracy and precision of the modified OT1 for 50 nL volumes of water was 0.2% and 2%, respectively. The accuracy and precision at 20 nL was 1% and 3.8%, respectively. The platform was successfully applied to the preparation of low-nanogram proteomic samples for liquid chromatography-mass spectrometry analysis. The modified OT1 is thus an effective platform for nanoliter liquid handling and, at a total cost of less than $6000 including the commercial liquid handler and all modifications, is far less expensive and more versatile than other platforms with similar capabilities, placing this technology within reach of a far broader scientific community.

47 OTHER INSTRUMENTATION↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Two 28-nm front-end ASICs for ultra-fine spatial resolution and precision timing to be 3D integrated with 12 LGADs

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (about 10 µm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present two 28 nm CMOS ASIC prototypes, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

28nm front end ASIC and 12” LGADs for 3D integration

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (≈10 μm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present the design and results from a 28 nm CMOS ASIC prototype, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. We also report on the co-design and characterization of reticle-scale LGAD sensors with 50 μm and 100 μm pixels and introduce the next 10k-pixel ASIC designed for full 3D integration. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Astrophysics of brown dwarfs; Proceedings of the Workshop, George Mason University, Fairfax, VA, Oct. 14, 15, 1985

Various reports on theoretical and observational studies of brown dwarfs (BDs) are presented. The topics considered include: astrometric detection of BDs, search for substellar companions to nearby stars using IR imaging, constraints on BD mass function from optical and IR searches, properties of stellar objects near the main sequence mass limit, search for low-mass stellar companions with the HF precision velocity technique, dynamical search for substellar objects, search for BDs in the IRAS data base, deep CCD survey for low mass stars in the disk and halo, the Berkeley search for a faint solar companion, the luminosity function for late M stars, astronomic search for IR dwarfs, and the role of the Space Telescope in the detection of BDs. Also addressed are: theoretical significance of BDs, evolution of super-Jupiters, compositional indicators in IR spectra of BDs, evolution of BDs and the evolutionary status of VB8B, the position of BDs on universal diagrams, theoretical determination of the minimum protostellar mass, Population II BDs and dark halos.

Kafatos, Minas C.↗

Precision Agriculture using Networks of Degradable Analytical Sensors (PANDAS) (Final Technical Report)

Precision agriculture, where sensing of soil, environment and crop conditions are used to precisely synchronize inputs (such as water and fertilizer) to crop needs enhances input use efficiency. This can improve yields and farm profitability while mitigating environmental losses, improving soil carbon content and substantially decreasing energy use for food, feed and fuel crops. Unfortunately, farmers are not yet able to harness the full potential of these management technologies as there is a lack of available management information, and there is therefore a need for sensors that are able to economically measure spatio-temporal variability in soil and crop properties of extremely heterogeneous farm fields precisely at high resolution and at low cost. Real-time, in-situ monitoring of agricultural soil conditions is today carried out using devices that limit the total number of nodes that can be used economically to typically one per acre or less. Higher spatio-temporal resolution sensing would enable more precise agricultural input optimization, with significant benefits to the farmer and the environment. In order to address this issue, this project focused on developing additively manufactured, biodegradable, soil sensors with predicted costs of < $\$$1 per unit to monitor crop inputs (such as water and fertilizer) that predictably, harmlessly degrade away into the soil when no longer needed. These sensor nodes should be easy to place, accurately and continuously monitor soil and crop conditions for an entire season, be read remotely using existing farm equipment, require no ongoing maintenance, not impede farm operations and produce no persistent waste. This approach could enable a >100× increase in information density over current solutions for precision farming of row and other crops, and lead to significant reductions in input energy use and provide increased yield for biofuel crops. Over the course of this project the team at the University of Colorado Boulder, University of California Berkeley, and Colorado State University/Kansas State University investigated a wide range of printable biodegradable electronic materials and sensor designs for determining soil moisture and soil nitrate concentration. These efforts expanded the available materials set for printed soil degradable electronic materials, particularly for conductors, enabling high conductivity and stability. Printed soil moisture and nitrate sensors with suitable sensitivity and selectivity were developed and characterized. Low power and passive wireless electronic systems were integrated with the soil sensors, and testing was carried out with completed sensors to understand their functionality under agricultural conditions. Additionally, other sensor types enabled by the biodegradable materials set created during this project, such as soil microbial activity sensors, were also developed and demonstrated. Project outputs include 10 peer reviewed publications, 4 patent applications, 21 technical presentations, 3 PhD thesis, 10 media reports, 8 additional grants worth over $\$$6M, and the formation of 3 start-up companies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Pericyclic Gearbox for Roving Application

Many aerospace mechanisms require high gear reduction ratios to reduce the high output speed of a motor to much lower speeds for precision rotation. Conventionally this actuation is performed with multiple gear stages, typically including a harmonic gearbox, and is required to be lightweight for spaceflight. One application of multiple gear stages is in rover wheel actuators intended for use on the Moon and Mars. These actuators require low total mass, high reliability, and precision actuation due to their remote operation. The pericyclic gearbox has the capability in a single stage to provide high reduction ratios equivalent to multiple conventional stages. Some benefits of utilizing pericyclic gear technology over multiple conventional stages are a compact form, fewer total parts, no reliance on flexible members (such as in harmonic drives), and lower total system mass. The goal of this work was to modify and build on existing modeling tools to determine the feasibility of utilizing the pericyclic gearbox for such an application. Critical aspects to consider were gear tooth loads, gear mesh efficiency, bearing loads, bearing efficiency, and total system mass. Developed tools were then used to examine a single stage pericyclic gearbox's trends in mass and efficiency for a Mars 2020 rover wheel actuator mechanism design case which was then compared to multistage gearbox designs.

Krantz, Timothy↗

3D Integrated Sensing Solutions

We will present the proposed research project to develop 3D-integrated sensors using advanced manufacturing capability for novel sensors, heterogeneously integrated with energy efficient readout circuits. The lack of precision timing in particle tracking detectors and the absence of low power, high throughput communications solutions to read them out limits progress in multiple fields of fundamental science. The aim of the project is to develop technology to enable large-scale particle detectors with 3D-integrated ASIC designs to simultaneously achieve 10 μm position resolution and 10 ps precision timing, with low-power consumption and high throughput rates. This research program leverages the unique combination of facilities and cross-disciplinary expertise of scientists and engineers at SLAC, FNAL, and LLNL and industrial partners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Redefining precision interferometry and spectroscopy with high-performance optical interference coatings

High-performance optical interference coatings have transformed precision interferometry and spectroscopy by enabling unparalleled control over light–matter interactions. This review explores recent innovations in ion-beam sputtered amorphous dielectric, as well as substrate-transferred crystalline coatings, and their impact on systems at the forefront of precision metrology. These state-of-the-art coating techniques generate multilayers with ultralow optical losses, yielding mirrors with exceptional reflectivity. Refinements in their noise performance push the ultimate limits of sensitivity, resolution, and stability in demanding laser-based metrology applications. These technologies underpin the most advanced timekeeping and spatial measurement tools, enabling high-finesse reference cavities for the world’s most precise optical atomic clocks and low-noise reflective test masses for km-baseline gravitational-wave detectors. Emerging hybrid designs combining these techniques expand access to the mid-infrared spectral region, enabling the first ultralow-optical-loss coatings in the 3000–5000 nm wavelength range for enhanced spectroscopy and trace-gas detection. We highlight how these technologies redefine coating performance metrics and set new benchmarks in quantum science, fundamental physics, and precision optical sensing.

Cole, Garrett D. [University of Arizona, Tucson, A↗

The Beauty and Complexity of the Brunt Ice Shelf from MOA and ICESat

Beginning in February 2003, NASA's Ice, Cloud, and land Elevation Satellite (ICESat) has determined surface elevations from approx. 86degN to 86degS latitude. To date, altimetry data have been acquired in a series of observation periods in repeated track patterns using all three Geoscience Laser Altimeter System (GLAS) lasers. This paper will focus on ice shelf elevation data that were obtained in 2003 across the Brunt Ice Shelf and the Stancomb-Wills Ice Tongue. Integrating the altimetry with the recently available MODIS Mosaic of Antarctica (MOA), quantifies the relative accuracy and precision of the resulting ice shelf elevations. Furthermore, the elevation data was processed onto an elevation grid, by regional interpolation across the area s complex glacial features only. Ice thickness estimation from the altimetry of the floating ice is discussed. ICESat operates at 40Hz and its elevation data is obtained every 172m along track. These elevations have a relative accuracy of about 14cm based on the standard deviation of low-slope crossover differences and a precision of close to 2cm for the Laser 2a, Release 21, GLA12 data used here.

Humbert, Angelika↗

Analysis of an induced Langmuir wave by ponderomotive forces and its applicability for plasma diagnostics

We present a numerical study on the electron and ion density perturbation in low-temperature plasmas driven by the frequency detuning of two intense laser beams. Our study is performed in the hydrodynamic regime, which becomes applicable when the plasma grating period induced by the beating of the laser beams is greater than the Debye length and collective processes such as plasma oscillations can be excited. Our findings show a resonance in electron density perturbation as the frequency detuning approaches a value consistent with the Bohm–Gross dispersion relation in low- and high-pressure plasmas. We discuss the potential of this resonance as a diagnostic tool for precisely measuring electron temperature and density in low-temperature plasmas through coherent scattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of SAGE II NO2 measurements

The validity of NO2 measurements from the stratospheric aerosol and gas experiment (SAGE) II is examined by comparing the data with climatological distributions of NO2 and by examining the consistency of the observations themselves. The precision at high altitudes is found to be 5 percent, which is also the case at specific low altitudes for certain latitudes where the mixing ratio is 4 ppbv, and the precision is 0.2 ppbv at low altitudes. The autocorrelation distance of the smoothed profile measurement noise is 3-5 km and 10 km for 1-km and 5-km smoothing, respectively. The SAGE II measurements agree with spectroscopic measurements to within 10 percent, and the SAGE measurements are about 20 percent smaller than average limb monitor measurements at the mixing ratio peak. SAGE I and SAGE II measurements are slightly different, but the difference is not attributed to changes in atmospheric NO2.

Cunnold, D. M.↗