Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RIGIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Biological Visualization, Imaging and Simulation(Bio-VIS) at NASA Ames Research Center: Developing New Software and Technology for Astronaut Training and Biology Research in Space

The Bio- Visualization, Imaging and Simulation (BioVIS) Technology Center at NASA's Ames Research Center is dedicated to developing and applying advanced visualization, computation and simulation technologies to support NASA Space Life Sciences research and the objectives of the Fundamental Biology Program. Research ranges from high resolution 3D cell imaging and structure analysis, virtual environment simulation of fine sensory-motor tasks, computational neuroscience and biophysics to biomedical/clinical applications. Computer simulation research focuses on the development of advanced computational tools for astronaut training and education. Virtual Reality (VR) and Virtual Environment (VE) simulation systems have become important training tools in many fields from flight simulation to, more recently, surgical simulation. The type and quality of training provided by these computer-based tools ranges widely, but the value of real-time VE computer simulation as a method of preparing individuals for real-world tasks is well established. Astronauts routinely use VE systems for various training tasks, including Space Shuttle landings, robot arm manipulations and extravehicular activities (space walks). Currently, there are no VE systems to train astronauts for basic and applied research experiments which are an important part of many missions. The Virtual Glovebox (VGX) is a prototype VE system for real-time physically-based simulation of the Life Sciences Glovebox where astronauts will perform many complex tasks supporting research experiments aboard the International Space Station. The VGX consists of a physical display system utilizing duel LCD projectors and circular polarization to produce a desktop-sized 3D virtual workspace. Physically-based modeling tools (Arachi Inc.) provide real-time collision detection, rigid body dynamics, physical properties and force-based controls for objects. The human-computer interface consists of two magnetic tracking devices (Ascention Inc.) attached to instrumented gloves (Immersion Inc.) which co-locate the user's hands with hand/forearm representations in the virtual workspace. Force-feedback is possible in a work volume defined by a Phantom Desktop device (SensAble inc.). Graphics are written in OpenGL. The system runs on a 2.2 GHz Pentium 4 PC. The prototype VGX provides astronauts and support personnel with a real-time physically-based VE system to simulate basic research tasks both on Earth and in the microgravity of Space. The immersive virtual environment of the VGX also makes it a useful tool for virtual engineering applications including CAD development, procedure design and simulation of human-system systems in a desktop-sized work volume.

Smith, Jeffrey↗

Coronal Rotation at Solar Minimum from UV Observations

UVCS/SOHO observations have been analyzed to reconstruct intensity time series of the O VI 1032 A and H 11216 A spectral lines at different coronal heliolatitudes from 1.5 to 3.0 solar radii from Sun center. Evidence was found for coronal differential rotation that differs significantly from that of the photospheric plasma. The study of the latitudinal variation shows that the UV corona decelerates toward the photospheric rates from the equator up to the poleward boundary 2 of the midlatitude streamers, reaching a peak of 28.16+/-0.20 days around +30 from the equator at 1.5 solar radii, while a less evident peak is observed in the northern hemisphere. This result suggests a real north-south rotational asymmetry as a consequence of different activity and weak coupling between the magnetic fields of the two hemispheres. The study of the radial rotation profiles shows that the corona is rotating almost rigidly with height.

Mancuso, S.↗

Dynamics of skyrmions in chiral magnets: Dynamic phase transitions and equation of motion

We study the dynamics of skyrmions in a metallic chiral magnet. First, we show that skyrmions can be created dynamically by destabilizing the ferromagnetic background state through a spin polarized current. We then treat skyrmions as rigid particles and derive the corresponding equation of motion. The dynamics of skyrmions is dominated by the Magnus force, which accounts for the weak pinning of skyrmions observed in experiments. Finally, we discuss the quantum motion of skyrmions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Passive Gravitational Attitude Control System for Satellites

It is shown how the gravity-gradient effect may be utilized to design a long-lived, earth-pointing satellite attitude control system which requires no fuel supplies, attitude sensors or active control equipment. This two-body system is provided with a magnetic hysteresis damper which effectively damps out oscillations (librations) about the local vertical. The long rods, which must be extended in space from coiled up metal tapes, provide the required large moments of inertia and possess adequate rigidity and sufficient strength to endure the rigors of the extension process. The system is compatible with the requirements of multiple satellite launchings from a single last-stage vehicle. Analysis indicates that the gravitational torques are sufficient to keep the disturbing effects of solar radiation pressure, residual magnetic dipole moments, orbit eccentricity, rod curvature, eddy currents, and meteorite impacts within tolerable limits. It is believed that the high-performance, earth-pointing system described and analyzed in this paper represents an essential step in the development of high-capacity communications satellites requiring long life.

GRAVITY↗

Crystal growth, electronic structure, and properties of Ni-substituted FeGa{sub 3}

Crystals of the Fe{sub 1−x}Ni{sub x}Ga{sub 3} limited solid solution (x<0.045) have been grown from gallium flux. We have explored the electronic structure as well as magnetic and thermoelectric properties of Fe{sub 0.975}Ni{sub 0.025}Ga{sub 3} in comparison with Fe{sub 0.95}Co{sub 0.05}Ga{sub 3}, following the rigid band approach and assuming that one Ni atom donates twice the number of electrons as one Co atom. However, important differences between the Co- and Ni-doped compounds are found below 620 K, which is the temperature of the metal-to-insulator transition for both compounds. We have found that Fe{sub 0.975}Ni{sub 0.025}Ga{sub 3} displays lower degree of spatial inhomogeneity on the local level and exhibits diamagnetic behavior with a broad shallow minimum in the magnetic susceptibility near 35 K, in sharp contrast with the Curie–Weiss paramagnetism of Fe{sub 0.95}Co{sub 0.05}Ga{sub 3}. Transport measurements have shown the maximum of the thermoelectric figure-of-merit ZT of 0.09 and 0.14 at 620 K for Fe{sub 0.975}Ni{sub 0.025}Ga{sub 3} and Fe{sub 0.95}Co{sub 0.05}Ga{sub 3}, respectively. - Graphical abstract: Crystals of Ni-substituted FeGa{sub 3} up to 8 mm long were grown from gallium flux (see Figure for the temperature profile and crystal shape) that allowed studying magnetic and thermoelectric properties of the title solid solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure of the low-lying states in 99,101,103,105 Pd

In this work, the odd-mass 99-105 Pd nuclei were studied via 90-96 Zr( 12,13 C, xnγ) fusion/evaporation reactions. The beam was provided by the IFIN-HH Tandem accelerator at energies of approximately 50 MeV. Emitted gamma rays were detected by the hybrid multidetector system RoSphere. The structure of the low-lying excited states in 99-105 Pd and their gamma-decay pattern are discussed in the framework of the rigid triaxial rotor plus particle model, providing a reasonable description of the low-lying level energies, electromagnetic transition rates, and magnetic moments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Control - Demands mushroom as station grows

The NASA space station, which is presently in the planning stage, is to be composed of both rigid and nonrigid modules, rotating elements, and flexible appendages subjected to environmental disturbances from the earth's atmospheric gravity gradient, and magnetic field, as well as solar radiation and self-generated disturbances. Control functions, which will originally include attitude control, docking and berthing control, and system monitoring and management, will with evolving mission objectives come to encompass such control functions as articulation control, autonomous navigation, space traffic control, and large space structure control. Attention is given to the advancements in modular, distributed, and adaptive control methods, as well as system identification and hardware fault tolerance techniques, which will be required.

Szirmay, S. Z.↗

A correlation between IMF and the limiting primary rigidity for the cosmic ray diurnal anisotropy

A plausible explanation is provided for the existence of the subsidiary maximum in the annual mean cosmic ray diurnal anisotropy, observed during the declining phase (1982-85) of the solar activity cycle 21. For this period, the values of the limiting primary rigidity (Rc), applicable to the steady state diurnal anisotropy, are quite large. Also, the annual mean magnitudes (B) of the interplanetary magnetic field (IMF) are very high. The data for Rc and B are reviewed for 1964-1987 period. A correlation is found to exist between the two parameters.

Ahluwalia, H. S.↗

Controlling magnetic configuration in soft–hard bilayers probed by polarized neutron reflectometry

Hard/soft magnetic bilayer thin films have been widely used in data storage technologies and permanent magnet applications. The magnetic configuration and response to temperatures and magnetic fields in these heterostructures are considered to be highly dependent on the interfacial coupling. However, the intrinsic properties of each of the layers, such as the saturation magnetization and layer thickness, also strongly influence the magnetic configuration. Changing these parameters provides an effective method to tailor magnetic properties in composite magnets. Here, we use polarized neutron reflectometry (PNR) to experimentally probe the interfacial magnetic configurations in the hard/soft bilayer thin films: L1 0 -FePt/A1-FePt, [Co/Pd]/CoPd, [Co/Pt]/FeNi, and L1 0 -FePt/Fe, all of which have a perpendicular magnetic anisotropy in the hard layer. These films were designed with different soft and hard layer thicknesses (t soft and t hard ) and saturation magnetization (M$_s^{soft}$ and M$_s^{hard}$). The influences of an in-plane magnetic field (H ip ) and temperature (T) are also studied using a L1 0 -FePt/A1-FePt bilayer sample. Comparing the PNR results to the micromagnetic simulations reveals that the interfacial magnetic configuration is highly dependent on t soft , M$_s^{soft}, and the external factors (H ip and T) and has a relatively weak dependence on t hard and M$_s^{hard}$. Key among these results, for thin t soft , the hard and soft layers are rigidly coupled in the out-of-plane direction and then undergo a transition to relax in-plane. This transition can be delayed to larger t soft by decreasing M$_s^{soft}$. Understanding the influence of these parameters on the magnetic configuration is critical to designing functional composite magnets for applications.

36 MATERIALS SCIENCE↗

Cold cathode ionization gage has rigid metal housing

Cold cathode ionization gage in a stainless steel housing accurately measures high pressures. The penning effect is used with a high voltage discharge in the presence of a magnetic field for an ion current proportional to the gas pressure in the gage.

Herzog, R.↗

Initial Feasibility and Clinical Implementation of Daily MR-Guided Adaptive Head and Neck Cancer Radiation Therapy on a 1.5T MR-Linac System: Prospective R-IDEAL 2a/2b Systematic Clinical Evaluation of Technical Innovation

This prospective study is, to our knowledge, the first report of daily adaptive radiation therapy (ART) for head and neck cancer (HNC) using a 1.5T magnetic resonance imaging-linear accelerator (MR-linac) with particular focus on safety and feasibility and dosimetric results of an online rigid registration-based adapt to position (ATP) workflow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

UNTWISTING MAGNETOSPHERES OF NEUTRON STARS

Magnetospheres of neutron stars are anchored in the rigid crust and can be twisted by sudden crustal motions ('starquakes'). The twisted magnetosphere does not remain static and gradually untwists, dissipating magnetic energy and producing radiation. The equation describing this evolution is derived, and its solutions are presented. Two distinct regions coexist in untwisting magnetospheres: a potential region where nabla x B = 0 ('cavity') and a current-carrying bundle of field lines with nabla x B not = 0 ('j-bundle'). The cavity has a sharp boundary, which expands with time and eventually erases all of the twist. In this process, the electric current of the j-bundle is sucked into the star. Observational appearance of the untwisting process is discussed. A hot spot forms at the footprints of the j-bundle. The spot shrinks with time toward the magnetic dipole axis, and its luminosity and temperature gradually decrease. As the j-bundle shrinks, the amplitude of its twist psi can grow to the maximum possible value psi{sub max} {approx} 1. The strong twist near the dipole axis increases the spindown rate of the star and can generate a broad beam of radio emission. The model explains the puzzling behavior of magnetar XTE J1810-197, a canonical example of magnetospheric evolution following a starquake. We also discuss implications for other magnetars. The untwisting theory suggests that the nonthermal radiation of magnetars is preferentially generated on a bundle of extended closed field lines near the dipole axis.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamics and inertia of a skyrmion in chiral magnets and interfaces: A linear response approach based on magnon excitations

We derive the skyrmion dynamics in response to a weak external drive, taking all the magnon modes into account. A skyrmion has rotational symmetry, and the magnon modes can be characterized by an angular momentum. For a weak distortion of a skyrmion, only the magnon modes with an angular momentum | m | = 1 govern the dynamics of skyrmion topological center. We also determine that the skyrmion inertia comes by way of the magnon modes in the continuum spectrum. For a skyrmion driven by a magnetic field gradient or by a spin transfer torque generated by a current, the dynamical response is practically instantaneous. This justifies the rigid skyrmion approximation used in Thiele's collective coordinate approach. For a skyrmion driven by a spin Hall torque, the torque couples to the skyrmion motion through the magnons in the continuum and damping; therefore the skyrmion dynamics shows sizable inertia in this case. The trajectory of a skyrmion is an ellipse for an ac drive of spin Hall torque.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-C-BRE-01: IGART: Fast On-Line Planning for IGART

Cone beam CT IGRT provides on-line anatomical data of the patient at the treatment couch while new hybrid MRI radiotherapy systems promise to provide this data during the actual radiation delivery itself. To exploit these data, and account for tissue rotations, deformations and tumor regression during radiation therapy delivery, fast, on-line IMRT (re)planning is required.On-line IMRT re-planning needs to re-generate a similar patient specific dose distribution as done in the pre-treatment planning but then for the new state of the anatomy. For this the pre-treatment information has to be propagated to the actual treatment. A fast dose engine is required, which may be, in the case of MRI based IGRT, Monte Carlo based in order to account for the magnetic field induced dose effects. Then robust re-planning methods or class solutions should be available that account efficiently for both rigid and non-rigid anatomical changes while preserving the patient specific pre-treatment dose considerations. Preferably this is all fully automatic, but also fast interactive re-planning is an option, especially in hypo-fractionated (boost) radiotherapy. Learning Objectives: Preservation of pre-treatment prescriptions in the on-line IMRT re-planning Fast re-planning techniques and speed limitations for dose engines Pros and cons of interactive versus automatic re-planning.

60 APPLIED LIFE SCIENCES↗

The mean free path of low rigidity cosmic rays

A simple heuristic argument is presented which suggests that the large rigidity independent mean free paths observed for low rigidity solar and galactic cosmic rays can be understood in terms of weak turbulence diffusion theory if one assumes that the interplanetary magnetic turbulence consists of a combination of Alfven waves propagating with constant field magnitude and a small (approximately 5-10%) admixture of compressive fluctuations.

Goldstein, M. L.↗

Magnetic refrigeration in space - Practical considerations

Various schemes of using adiabatic demagnetization to provide refrigeration in the 10-1000 mK range are discussed with particular reference to the requirements for use in space. The methods considered are complete demagnetization, isothermal demagnetization, moving magnet demagnetization, and continuous refrigeration. The requirements that are important for use in space are low mass, low power dissipation, high mechanical rigidity, modular design, and ease of use.

Kittel, P.↗

System identification of the Large-Angle Magnetic Suspension Test Fixture (LAMSTF)

The Large-Angle Magnetic Suspension Test Fixture (LAMSTF), a laboratory-scale research project to demonstrate the magnetic suspension of objects over wide ranges of attitudes, has been developed. This system represents a scaled model of a planned Large-Gap Magnetic Suspension System (LGMSS). The LAMSTF consists of a small cylindrical permanent magnet suspended element which is levitated above a planar array of five electromagnets mounted in a circular configuration. The cylinder is a rigid body and can be controlled to move in five independent degrees of freedom. Six position variables are sensed indirectly by using infrared light-emitting diodes and light-receiving phototransistors. The motion of the suspended cylinder is in general nonlinear and hence only the linear, time-invariant perturbed motion about an equilibrium state is considered. One of the main challenges in this project is the control of the suspended element over a wide range of orientations. An accurate dynamic model plays an essential role in controller design. The analytical model is first derived and open-loop characteristics discussed. The system is shown to be highly unstable and requires feedback control for system identification. Projection filters are first proposed to identify the state space model from closed-loop input/output test data in the time domain. This method is then extended to identify linear systems from the frequency test data. A canonical transformation matrix is also derived to transform the identified state space model into the physical coordinate. The LAMSTF system is stabilized by using a linear quadratic regulator (LQR) feedback controller for closed-loop identification. The rate information is obtained by calculating the back difference of the sensed position signals. Only the closed-loop random input/output data are recorded. Preliminary results from numerical simulations demonstrate that the identified system model is fairly accurate from either time domain or frequency-domain data. Experiments will be performed to validate the proposed closed-loop identification algorithms.

Huang, Jen-Kuang↗