Age determination of a 75 Se gamma radiography source for nuclear forensics

Here, two methods were used to evaluate the age of 75 Se sealed source material. Both methods utilized gamma spectroscopy to determine the quantity of parent 75 Se present, but they differed in the technique used to determine the quantity of daughter 75 As. In one method, 75 As was quantified using inductively coupled plasma-mass spectrometry (ICP-MS) after using chromatographic techniques to separate the parent and daughter isotopes. In the other method, total As was measured using optical emission spectroscopy (OES), which did not require separation prior to measurement. The OES method was faster and gave slightly lower uncertainties, but required more daughter material to be present because of higher concentration requirements, making it unsuitable for young material. Both methods are hampered by the monoisotopic nature of As, but still gave reasonable model ages that were in agreement with each other.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluating the Persistence of Soil Carbon After a 30-Year Nitrogen Fertilization Experiment at the Fernow Experimental Forest, WV

We sampled soils in a previously nitrogen (N)-fertilized watershed (Watershed 3), which received 35 kg N per hectare annually for 30 years, and a reference watershed (Watershed 7), 4 years after the end of a 30-year N fertilization experiment at the Fernow Experimental Forest in West Virginia. As N deposition has reduced soil pH and plant carbon (C) investments into the rhizosphere, we compared the extent to which removing these potential limitations to microbial decomposition by increasing soil pH, adding artificial root exudates, or elevating soil temperature would increase microbial decomposition (and soil C losses) in soils that have and have not received excess N inputs. As such, we incubated soils with and without the addition of artificial root exudates and dolomitic lime (2 amendment treatments and 1 untreated control), at three different temperatures (15, 20, and 25 C) to simulate warming. We measured soil respiration, enzyme activity (acid phosphatase, N -acetyl-β-glucosaminidase, beta-glucosidase, phenol oxidase, and peroxidase), and microbial biomass carbon in a 15-week microcosm experiment. All of the datasheets include the metadata for all of the treatment combinations from this incubation experiment (ID, incubation temperature, treatment, watershed).The "Soil_Chemistry_Data.csv" data includes (1) the ratio of dry soil weight (g) by wet (or fresh) soil weight (g) after 72 hours at 65 C, (2) the wet (or fresh) weight of the soil samples used to determine soil pH, and (3) soil pH, which was measured in CaCl2. Detailed methods for the measurements of soil pH are described in the datasheet itself.The "Respiration_Data.csv" data includes (1) respiration day for the measurement, and (2) cumulative CO2 respiration (mmol) measured in the microcosms on specific days.The "Microbial_Biomass_Data.csv" data includes (1) mmol microbial biomass carbon per g (dry weight) of soil in each microcosm.The "Enzyme_Data.csv" data includes (1) all extracellular soil enzyme activity (N-acetyl-glucosaminidase (NAG), acid phosphatase (AP), β-glucosidase (BG), phenol oxidase and peroxidase) that we measured in our microcosms.

54 ENVIRONMENTAL SCIENCES↗

Dose Calculations from Source Models and Gamma-Ray Spectra

Gamma-ray dose rates computed by two radiation source model-based methods and five measured spectrum-based methods are compared. With the exception of a Detective DX-100, which reported dose rates that are about 25% less than the mean, dose rates are generally within 10% of mean values. Methods for computation of dose rates employed by the Gamma Detector Response and Analysis Software (GADRAS) are described and critically evaluated. Results are presented for a feasibility evaluation that seeks to use spectra recorded inside vehicles to estimate the minimum dose outside the vehicles.

61 RADIATION PROTECTION AND DOSIMETRY↗

The dual-electron cyclotron emission based measurement of 3D structures on DIII-D tokamak

The measurements of the locked mode and other 3D magnetohydrodynamic modes are essential for real-time control of plasma stability in future fusion reactors. Current magnetic measurements present non-negligible challenges for the application on fusion pilot plants (FPPs) due to neutron radiation and pose challenging design issues. In this paper, we discuss an alternative solution with microwave-based measurements. The dual-electron cyclotron emission (ECE) method has been developed and applied on DIII-D. The dual-ECE measurement method demonstrates clear identification of magnetic islands compared to single ECE, which is highly beneficial for locked mode feedback control on the FPPs. Toroidally separated ECE measurements provide accurate three-dimensional structure of magnetic islands and tearing modes. This technique also offers deeper physical insights into the penetration of resonant magnetic perturbations. Numerical calculations indicate that small locked modes (magnetic island width > 2 cm) can be detected using the dual-ECE measurement method in ITER plasma. This will enhance measurement capabilities for the safe operation of FPP plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introducing a novel technique for measuring hydrogen crossover in membrane-based electrochemical cells

Hydrogen crossover that is the unwanted hydrogen permeation across the membrane driven by the difference of gas concentrations causes a critical concern of safety and efficiency for electrochemical cells, such as fuel cells and electrolyzer cells. Although the hydrogen crossover measurement in fuel cells that employ platinum based catalysts is simple and widely used in laboratory settings, it is questionable to apply existing limiting current method to water electrolyzer cells and alkaline exchange membrane (AEM) systems, which is due to the typical catalyst materials used and membrane properties, respectively. In this work, we demonstrate the operation of a compact and low-cost method of measuring hydrogen crossover that works for both AEM and proton exchange membrane (PEM) systems. The method entails a tandem configuration that utilizes an upstream crossover cell with a downstream cell in hydrogen pump configuration to measure the crossover in the cell of interest. We have successfully measured the hydrogen crossover with different membranes at various differential pressures. The developed method can be applied to catalyst-free membranes (both PEM and AEM) as well as PGM free catalyst containing cells. It will be a promising technique for measuring hydrogen crossover in-situ for a real operating membraned-based electrochemical cell or stack.

08 HYDROGEN↗

Quantitative Measurement of Li-Ion Concentration and Diffusivity in Solid-State Electrolyte

Here, we present a quantitative method to measure the concentration and diffusivity of Li ion in a solid-state electrolyte with nanoscale depth resolution. We designed a standard sample with different depths of trenches and used time-of-flight secondary ion mass spectroscopy, inductively coupled plasma optical emission spectroscopy, three-dimensional (3D) optical microscopy, and electrochemical strain microscopy to obtain effective Li-ion concentration and the corresponding diffusivity as a function of depth. As a result, we verified the dependence of electromechanical strain induced by ionic oscillation on mobile-ion concentration. We also showed the diffusivity change as a function of effective concentration and discussed the difference in diffusivity near the surface and inside the bulk. Our method can be widely used for electromechanical strain in various ionic conductors, rendering our technique universal for quantitative analysis of ionic dynamics at a multiscale.

36 MATERIALS SCIENCE↗

A new open‐path eddy covariance method for nitrous oxide and other trace gases that minimizes temperature corrections

Abstract Low‐power, open‐path gas sensors enable eddy covariance (EC) flux measurements in remote areas without line power. However, open‐path flux measurements are sensitive to fluctuations in air temperature, pressure, and humidity. Laser‐based, open‐path sensors with the needed sensitivity for trace gases like methane (CH 4 ) and nitrous oxide (N 2 O) are impacted by additional spectroscopic effects. Corrections for these effects, especially those related to temperature fluctuations, often exceed the flux of gases, leading to large uncertainties in the associated fluxes. For example, the density and spectroscopic corrections arising from temperature fluctuations can be one or two orders of magnitude greater than background N 2 O fluxes. Consequently, measuring background fluxes with laser‐based, open‐path sensors is extremely challenging, particularly for N 2 O and gases with similar high‐precision requirements. We demonstrate a new laser‐based, open‐path N 2 O sensor and a general approach applicable to other gases that minimizes temperature‐related corrections for EC flux measurements. The method identifies absorption lines with spectroscopic effects in the opposite direction of density effects from temperature and, thus, density and spectroscopic effects nearly cancel one another. The new open‐path N 2 O sensor was tested at a corn ( Zea mays L.) field in Southwestern Michigan, United States. The sensor had an optimal precision of 0.1 ppbv at 10 Hz and power consumption of 50 W. Field trials showed that temperature‐related corrections were 6% of density corrections, reducing EC random errors by 20‐fold compared to previously examined lines. Measured open‐path N 2 O EC fluxes showed excellent agreement with those made with static chambers ( m = 1.0 ± 0.3; r 2 = .96). More generally, we identified absorption lines for CO 2 and CH 4 flux measurements that can reduce the temperature‐related corrections by 10–100 times compared to existing open‐path sensors. The proposed method provides a new direction for future open‐path sensors, facilitating the expansion of accurate EC flux measurements.

47 OTHER INSTRUMENTATION↗

Flash Freeze Flow Tube to Vitrify Aerosol Particles at Fixed Relative Humidity Values

Development of methods to measure the phase transitions and physical properties of submicron atmospheric aerosol particles is needed to better model these systems. Here, we introduce a method to flash freeze submicron particles to measure phase transitions as a function of relative humidity (RH). Particles are equilibrated at a fixed RH, vitrified in a temperature-controlled flow tube, and imaged with cryogenic transmission electron microscopy (cryo-TEM). We demonstrate the use of the technique for measuring the efflorescence relative humidity (ERH) of potassium sulfate and potassium chloride aerosol as well as the separation RH for a multicomponent organic/inorganic system that undergoes liquid-liquid phase separation (LLPS). The location of phase transitions can shift between the micrometer and nanometer size regimes and particles in a given population may have a range of RH over which a phase transition occurs. This technique addresses these requirements by allowing for characterization of the phase transitions for individual particles in a population on the submicron scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High broadband photoconductivity of few-layered MoS 2 field-effect transistors measured using multi-terminal methods: effects of contact resistance

Among the layered two dimensional semiconductors, molybdenum disulfide (MoS 2 ) is considered to be an excellent candidate for applications in optoelectronics and integrated circuits due to its layer-dependent tunable bandgap in the visible region, high ON/OFF current ratio in field-effect transistors (FET) and strong light–matter interaction properties. In this study, using multi-terminal measurements, we report high broadband photocurrent response ( R ) and external quantum efficiency (EQE) of few-atomic layered MoS 2 phototransistors fabricated on a SiO 2 dielectric substrate and encapsulated with a thin transparent polymer film of Cytop. The photocurrent response was measured using a white light source as well as a monochromatic light of wavelength λ = 400 nm–900 nm. We measured responsivity using a 2-terminal configuration as high as R = 1 × 10 3 A W -1 under white light illumination with an optical power P opt = 0.02 nW. The R value increased to 3.5 × 10 3 A W -1 when measured using a 4-terminal configuration. Using monochromatic light on the same device, the measured values of R were 10 3 and 6 × 10 3 A W -1 under illumination of λ = 400 nm when measured using 2- and 4-terminal methods, respectively. The highest EQE values obtained using λ = 400 nm were 10 5 % and 10 6 % measured using 2- and 4-terminal configurations, respectively. The wavelength dependent responsivity decreased from 400 nm to the near-IR region at 900 nm. The observed photoresponse, photocurrent–dark current ratio (PDCR), detectivity as a function of applied gate voltage, optical power, contact resistances and wavelength were measured and are discussed in detail. The observed responsivity is also thoroughly studied as a function of contact resistance of the device.

36 MATERIALS SCIENCE↗

Neural Network‐Based Methods for Ocean Surface Wave Measurement Using Submarine Distributed Acoustic Sensing (DAS)

Two new data-driven models for estimating ocean surface waves from distributed acoustic sensing (DAS) submarine cable strain rate are developed using supervised machine learning on a 10-day data set collected offshore of Oliktok Point, Alaska. The new models were trained on target data from seafloor pressure moorings at three sites spaced evenly along 27.1 km of cable and were benchmarked against an empirical transfer function method previously used to estimate waves from DAS. A model which uses convolutional neural networks to transform 2-km frequency-wavenumber strain spectra to seafloor pressure spectra outperforms the benchmark in wave height prediction (RMSE of 0.15 vs. 0.41 m) and period prediction (0.29 vs. 0.37 s) when evaluated on a held-out test data set. When applied to a DAS data set collected on the same cable 2 years prior, the CNN-based model maintained similar significant wave height performance (RMSE = 0.23 m) relative to available satellite altimetry data. A two-hidden-layer, fully connected neural network which transforms 1-D strain spectra to seafloor pressure spectra also outperforms the benchmark in wave height prediction (RMSE of 0.19 vs. 0.41 m), but does not generalize as well to the prior data. Regression-based machine learning is useful for estimating waves from DAS data when the pressure-strain relationship varies temporally and spatially across different wave conditions. Models can be applied to DAS data to measure waves with higher spatial resolution and longer temporal coverage than traditional methods, which often measure waves only at a single point.

Davis, Jacob R. [Univ. of Washington, Seattle, WA ↗

Experiments at TA-55 have used optical pyrometry to measure temperatures of shocked plutonium on the 40mm gun

Researchers at LANL, along with collaborators from MSTS, have worked for more than a decade to develop and implement an optical pyrometry method to measure the temperature of metals shocked to the high pressures and temperatures. Because traditional shock wave measurements only provide information on the mechanical state of the material, temperature measurements are required to validate and improve equation-of-state (EOS) models for materials. The conditions sampled are complex; commenserate with those found in planetary impacts, and accressed by conventional and nuclear weapons. Optical pyrometry is currently the best available method for inferring the temperature of shocked metals, by careful measurement of the calibrated radiance emitted by a surface at finite temperature. These measurements are difficult often complicated by the short time scales associated with shock wave experiments (<1 µs) coupled with the many sources of non-thermal light (impact flash, fracture light, etc.) that pollutes the radiant light measured from the sample.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thickness and uniformity mapping of thin foils using resistive silicon detectors

Alpha energy loss is a common tool used for measuring target thicknesses. However, these measurements are often made without position information, which either forfeits knowledge of material uniformity and local thickness or requires a prohibitive number of measurements per target to partially recover this information. In consideration of this, a method for measuring position-dependent thicknesses is described in this work; by using the position-sensitivity of the dual-axis duo-lateral (DADL) silicon detector, thicknesses across the entire face of the material can be measured to sub-mm precision with a single measurement. Several examples are presented using a number of targets with varying characteristics, which altogether demonstrate the precision, accuracy, and versatility of this technique.

Foil uniformity↗

Atmospheric 81 Kr as an Integrator of Cosmic-Ray Flux on the Hundred-Thousand-Year Time Scale

The atmospheric abundance of 81 Kr is a global integrator of cosmic rays. It is insensitive to climate shifts, geographical variations, and short-term solar cycle activity, making it an ideal standard to test models of cosmic-ray flux on the time scale of 10 5 years. In this work, we present the first calculation of absolute 81 Kr production rates in the atmosphere, and a measurement of the atmospheric 81 Kr/Kr abundance via the Atom Trap Trace Analysis method. The measurement result significantly deviates from previously reported values. The agreement between measurement and model prediction supports the current understanding of the production mechanisms. Additionally, the calculated 81 Kr atmospheric inventory over the past 1.5 Myr provides a more accurate input function for radiokrypton dating.

58 GEOSCIENCES↗

Coordinated Control of Natural and Sub-Synchronous Oscillations via HVDC Links in Great Britain Power System

Conventional power oscillation damping (POD) controllers have been designed to be effective in damping either inter-area low-frequency oscillations (LFO) or sub-synchronous oscillations (SSO). For those POD controls, model-based control design method has been widely implemented with wide-area feedback signals from phasor measurement units (PMU). However, the model accuracy of a large realistic power system can hardly be guaranteed, which will finally impact the POD damping performance. In this paper, a measurement-based method is proposed for POD design using High Voltage Direct Current links (HVDC) to realize the coordinated control of both LFO and SSO. For each type of oscillations, a band-pass filter is added to avoid the interactions between different modes. Case studies are carried out on the Great Britain 36-bus power system model with multiple HVDC links in DIgSILENT/PowerFactory. Simulation results demonstrate that the proposed PODs are effective in damping inter-area LFO and SSO simultaneously.

Zhao, Yi↗

A remote sensing algorithm for vertically resolved cloud condensation nuclei number concentrations from airborne and spaceborne lidar observations

Cloud condensation nuclei (CCN) are mediators of aerosol–cloud interactions (ACIs), contributing to the largest uncertainties in the understandings of global climate change. We present a novel remote-sensing-based algorithm that quantifies the vertically resolved CCN number concentrations (N CCN ) using aerosol optical properties measured by a multiwavelength lidar. The algorithm considers five distinct aerosol subtypes with bimodal size distributions. The inversion used the lookup tables developed in this study, based on the observations from the Aerosol Robotic Network, to efficiently retrieve optimal particle size distributions from lidar measurements. The method derives dry aerosol optical properties by implementing hygroscopic enhancement factors in lidar measurements. The retrieved optically equivalent particle size distributions and aerosol-type-dependent particle composition are utilized to calculate critical diameters using κ-Köhler theory and N CCN at six supersaturations ranging from 0.07 % to 1.0 %. Sensitivity analyses indicate that uncertainties in extinction coefficients and relative humidity greatly influence the retrieval error in N CCN . The potential of this algorithm is further evaluated by retrieving N CCN using airborne lidar from the NASA ObseRvations of Aerosols above CLouds and their intEractionS (ORACLES) campaign and is validated against simultaneous measurements from the CCN counter. The independent validation with robust correlation demonstrates promising results. Furthermore, the N CCN has been retrieved for the first time using a proposed algorithm from spaceborne lidar – Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) – measurements. The application of this new capability demonstrates the potential for constructing a 3D CCN climatology at a global scale, which helps to better quantify ACI effects and thus reduce the uncertainty in aerosol climate forcing.

54 ENVIRONMENTAL SCIENCES↗

The effect of relative humidity on eddy covariance latent heat flux measurements and its implication for partitioning into transpiration and evaporation

While the eddy covariance (EC) technique is a well-established method for measuring water fluxes (i.e., evaporation or 'evapotranspiration’, ET), the measurement is susceptible to many uncertainties. One such issue is the potential underestimation of ET when relative humidity (RH) is high (> 70%), due to low-pass filtering with some EC systems. Yet, this underestimation for different types of EC systems (e.g. open-path or closed-path sensors) has not been characterized for synthesis datasets such as the widely used FLUXNET2015 dataset. Here, we assess the RH-associated underestimation of latent heat fluxes (LE, or ET) from different EC systems for 163 sites in the FLUXNET2015 dataset. We found that the LE underestimation is most apparent during hours when RH is higher than 70%, predominantly observed at sites using closed-path EC systems, but the extent of the LE underestimation is highly site-specific. We then propose a machine learning based method to correct for this underestimation, and compare it to two energy balance closure based LE correction approaches (Bowen ratio correction, BRC, and attributing all errors to LE). Our correction increases LE by 189% for closed-path sites at high RH (> 90%), while BRC increases LE by around 30% for all RH conditions. Additionally, we assess the influence of these corrections on ET-based transpiration (T) estimates using two different ET partitioning methods. Results show opposite responses (increasing vs. slightly decreasing T-to-ET ratios, T/ET) between the two methods when comparing T based on corrected and uncorrected LE. Overall, our results demonstrate the existence of a high RH bias in water fluxes in the FLUXNET2015 dataset and suggest that this bias is a pronounced source of uncertainty in ET measurements to be considered when estimating ecosystem T/ET and WUE.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Temperature Heterogeneity in Utility-Scale Power Plant Boilers by Spatially Distributed Ultrasonic Measurements

In extreme environments, even hardened insertion sensors fail quickly. For such environments, we have developed an ultrasonic (US) method for measuring the spatial distribution of temperatures in solid materials and, specifically, across containments of extreme processes. By deploying US sensors in multiple locations, spatial heterogeneity in temperatures inside harsh environments may be characterized. In this note, we update our progress on testing the developed approach in an industrial setting and its performance in describing the temperature distribution inside a 500 MW (electrical) coalfired utility boiler of an electrical power generation plant. We use waveguides (WG) structured to contain echogenic features that produce a train of echoes in response to an excitation pulse. The time of flight between echoes encodes the information on the temperature distribution in the corresponding segment of the WG, which we reconstruct using its parametrization. Five waveguides were welded to the boiler’s heat exchange surface (waterwall) and different locations at the same boiler elevation and produced reliable US waveforms 18 months after the installation. For several weeks during the latest trial, we performed US measurements in five locations spanning half of the boiler’s 14-meter width. The measurements were acquired during regular operation, including load cycling to adjust for demand and intermittent contributions of renewable power sources, and during boiler shutdown for emergency maintenance and the subsequent restart. The interpretation of US waveforms by signal processing resulted in an accurate estimation of temperature distribution along the waveguides. We captured daily cyclical variations in demand-following load. Measurements performed in multiple locations revealed unexpected temperature variations across the boiler. We conclude that an array of developed sensors can provide responsive and spatial temperature measurements while maintaining functionality despite prolonged exposure to an extreme environment.

Walton, Kenneth↗