Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Point Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Developing a new criticality methodology to support decommissioning of legacy plutonium facilities

To decommission a legacy plutonium finishing facility, a number of gloveboxes need to be disposed of. These gloveboxes have been in place since the 1960's and were operational until the 1980's. A period of initial clean out and decommissioning took place in the 1990's and the first gloveboxes were removed from the line in the early 2000's. Compliance with downstream waste handling facility requirements meant that the gloveboxes needed to be removed using intensive 'hands-on' methods in order to size reduce them to fit into 200 litre (55 gallon) drums. This is the standard approach for handling waste items known as Plutonium Contaminated Material (PCM) on the Sellafield site and was credited in the criticality safety case for the decommissioning of the gloveboxes as it allowed each waste drum to be individually assayed such that the fissile content of the waste could be known. Not only was this approach time-consuming and laborious but as it involved operators working with cutting tools in a highly contaminated area it was challenged as being overly restrictive to operations and potentially hazardous to the workers. In order to decommission the remaining nine gloveboxes in the facility, a new decommissioning approach and associated criticality methodology has been developed. Instead of intensive size reduction and waste drum assay, the gloveboxes will be removed with little or no size reduction and put into storage crates without assay. The criticality assessor will review the operational history of each glovebox, along with the decommissioning records and relevant plant data, to make an evidence-based judgement that the crated glovebox represents no greater a residual criticality risk than would have been realised from the equivalent number of PCM drums that the standard decommissioning approach would have generated. This method identifies, in conjunction with the plant personnel, a number of review points to ensure that before the glovebox is removed any bulk residue material has been recovered and no more than a safe amount of moderating material (fixative) has been added to fix any remaining fissile contamination. Finally, once these review points have been confirmed to be complete - through a stakeholder meeting with criticality safety, plant operators and project managers - the glovebox will be placed in a crate, and this crate will be declared a Low Criticality Risk crate. No formal assay will be required prior to exporting the crate to the downstream waste handling facility and no fissile mass value will be assigned to the contents of the crate. No further intrusive work will be required on the crate and it can be safely stored without any spacing requirements, pending final disposal. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energetics and Concentration of Defects in Gd2Ti2O7 and Gd2ZrO7 Pyrochlore at High Pressure

Using first-principles calculations and complementary experiments, the defect formation energies and defect concentrations were calculated as a function of pressure. The results show that at high pressure, the defect formation energies decrease with pressure for both systems. In Gd{sub 2}Ti{sub 2}O{sub 7}, the dominant defect type is cation anti-site defect, the local structure around a defect is highly distorted, and the energetically favorable defect-defect interactions at shorter distance suggest the possibility of defect clustering. In Gd{sub 2}Zr{sub 2}O{sub 7}, anion Frenkel-pair defects are favored at all pressures and the dominant defect type involving a cation is a coupled defect of a cation anti-site and an anion Frenkel-pair defect. There are only minor distortions around the defects, and the defect-defect interactions are weak, which suggests almost-ideal non-interacting defect formation. Comparison of experimentally observed defect concentrations and those based on the calculated defect formation energies suggests that the defects formed at high pressure are better estimated with a concentrated limit approximation, while those formed at ambient pressure can be evaluated at a dilute limit approximation.

36 MATERIALS SCIENCE↗

Dielectric screening and vacancy formation for large neutral and charged Si n H m ( n > 1500 ) nanocrystals using real-space pseudopotentials

A commonly used procedure for computing the properties of defects in crystalline materials is to consider a large supercell that includes the defect of interest. This is a straightforward technique as standard energy band codes can be used for such computations. For neutral defects, the only impediment of such an approach is to avoid defect-defect interactions between adjoining cells. However, this procedure can be complex if the defect of interest is charged as the system at large contains Coulombic divergences. Moreover, some have recently argued that the conventional definition of formation energies for charged defects cannot be reconciled with statistical mechanics. Here, we focus on an alternative approach. We consider large nanocrystals wherein a charged defect can be placed. Since the system is confined, a charged defect within the nanocrystal does not result in a Coulombic divergence. The chief impediment is computational, i.e., while no defect-defect or Coulombic divergences are present, the nanocrystal must be sufficiently large to allow the system to properly replicate a bulklike configuration. With the development of new algorithms and hardware advances, computations for systems of sufficient size to address this issue are feasible. In particular, we solve the Kohn-Sham equation in real space using pseudopotential-density-functional theory for large silicon nanocrystals, which contain thousands of atoms. Further, we focus on (i) the screening of a point charge and (ii) the formation of a charged vacancy in hydrogen-terminated silicon nanocrystals. This approach allows us to examine the role of quantum confinement in addition to exploring the bulk limit. Comparisons to other methods confirm the viability of this approach.

36 MATERIALS SCIENCE↗

Three-dimensional Reconstruction and Homogenization of Heterogeneous Materials Using Statistical Correlation Functions and FEM

In this study, a previously developed reconstruction methodology is extended to three-dimensional reconstruction of a three-phase microstructure, based on two-point correlation functions and two-point cluster functions. The reconstruction process has been implemented based on hybrid stochastic methodology for simulating the virtual microstructure. While different phases of the heterogeneous medium are represented by different cells, growth of these cells is controlled by optimizing parameters such as rotation, shrinkage, translation, distribution and growth rates of the cells. Based on the reconstructed microstructure, finite element method (FEM) was used to compute the effective elastic modulus and effective thermal conductivity. A statistical approach, based on two-point correlation functions, was also used to directly estimate the effective properties of the developed microstructures. Good agreement between the predicted results from FEM analysis and statistical methods was found confirming the efficiency of the statistical methods for prediction of thermo-mechanical properties of three-phase composites.

36 MATERIALS SCIENCE↗

Surface analysis insight note: Differentiation methods applicable to noisy data for determination of sp2‐ versus sp3‐hybridization of carbon allotropes and AES signal strengths

The derivatives of the spectra are commonly used for quantification in Auger Electron Spectroscopy (AES) spectra, while the derivative of the KLL C Auger line has proven to be valuable in obtaining a measure of the relative proportions of sp 2 ‐ and sp 3 ‐hybridization using the D‐parameter in both AES and X‐ray Photoelectron Spectroscopy (XPS). Differentiation of X‐ray Photoelectron Spectroscopy (XPS) and Auger Electron Spectroscopy (AES) spectra by numerical means is presented and illustrated for polymeric, such as PEEK and Nylon, as well as for graphitic materials including highly ordered pyrolytic graphite and graphene oxide. The most commonly available Savitzky–Golay method is explained mathematically and developed through the case of constructing a 5‐point quadratic polynomial convolution kernel suitable for differentiating spectra of adequate signal to noise. The concept of differentiation of spectra where signal to noise is less than adequate is also developed. Two alternative strategies to Savitzky–Golay differentiation are presented, which fit curves to data that allow derivatives to be obtained where Savitzky–Golay would otherwise fail. These alternative methods involve constructing a parametric curve that fits data over the entire energy interval of interest. Derivatives of spectra are then obtained by differentiating these parametric curves directly. A comparison of results for different materials for which specific sp 2 ‐ vs sp 3 ‐hybridized carbon proportions are of interest is used to emphasize the importance of characterizing methods used to differentiate spectra and understanding the characteristics of instrumentation used to measure spectra. The case for using Principal Component Analysis noise reduction with C KLL spectra is made for spectra collected from a heterogeneous graphene oxide sample.

Fairley, Neal↗

Thermographic Microstructure Monitoring in Electron Beam Additive Manufacturing

To reduce the uncertainty of build performance in metal additive manufacturing, robust process monitoring systems that can detect imperfections and improve repeatability are desired. One of the most promising methods for in-situ monitoring is thermographic imaging. However, there is a challenge in using this technology due to the difference in surface emittance between the metal powder and solidified part being observed that affects the accuracy of the temperature data collected. This developed a method for properly calibrating temperature profiles from thermographic data and then determining important characteristics of the build through additional processing. The thermographic data was analyzed to determine the transition of material from metal powder to a solid as-printed part. A corrected temperature profile was then assembled for each point using calibrations for these surface conditions. Using this data, we calculated the thermal gradient and solid-liquid interface velocity and correlated it to microstructural variation within the part experimentally. This work shows that by using a method of process monitoring, repeatability of a build could be monitored specifically in relation to microstructure control.

36 MATERIALS SCIENCE↗

Gel-like properties of MCM-41 material and its transformation to MCM-50 in a caustic alkaline surround

Highlights: Black-Right-Pointing-Pointer MCM-41 material transforms gradually into MCM-50 lamellar gel upon controlled exposure to 6 M KOH. Black-Right-Pointing-Pointer The formation of MCM-50 ordered gel structure occurs at KOH weight content of 40-70 wt. %. Black-Right-Pointing-Pointer MCM gel phase shows pseudoplastic behavior and possesses homogeneous matrix texture. -- Abstract: MCM-41 material, prepared by sol-gel method, reveals gel-like properties in a caustic alkaline environment, i.e., 6 M potassium hydroxide (KOH) electrolyte. The gellation of MCM-41 starts at a KOH weight ratio of 40 wt.%. The structural change of the material is verified with X-Ray diffractograms and supported by observation using Scanning Electron Microscope (SEM). As the KOH weight ratio increases, the MCM-41 hexagonal arrays structure gradually transforms into MCM-50 lamellar structure before disappearing completely at 80 wt.% KOH. The MCM gel phase is further characterized by rotational viscometry and texture analysis. The gel phase shows shear thinning or pseudoplastic behavior and possesses homogeneous matrix structure.

36 MATERIALS SCIENCE↗

Efficacy of the Method of Four Coefficients to Determine Charge-Carrier Scattering

The investigation of the electronic properties of semiconductors from transport measurements (i.e., resistivity, Hall, and Seebeck coefficient measurements) is challenging due to the averaging of charge-carrier dynamics inherent in such measurements. Here, we investigate the incorporation of a fourth measurement of electronic transport, the Nernst coefficient, into the analysis, termed the method of four coefficients. This approach yields the Fermi level, effective mass, scattering exponent, and relaxation time prefactor. We begin with a review of the underlying mathematics and investigate the mapping between the four-dimensional material property and transport coefficient spaces. We then investigate how the traditional single-parabolic band method yields a single, potentially incorrect point on the solution subspace. This uncertainty can be resolved through Nernst coefficient measurements and we map the span of the ensuing subspace. We conclude with an investigation of how sensitive the analysis of transport coefficients is to experimental error for different sample types.

charge carriers↗

Three-dimensional plastic response in polycrystalline copper via near-field high-energy X-ray diffraction microscopy

The evolution of the crystallographic orientation field in a polycrystalline sample of copper is mapped in three dimensions as tensile strain is applied. Here, using forward-modeling analysis of high-energy X-ray diffraction microscopy data collected at the Advanced Photon Source, the ability to track intragranular orientation variations is demonstrated on an ~2 µm length scale with ~0.1° orientation precision. Lattice rotations within grains are tracked between states with ~1° precision. Detailed analysis is presented for a sample cross section before and after ~6% strain. The voxel-based (0.625 µm triangular mesh) reconstructed structure is used to calculate kernel-averaged misorientation maps, which exhibit complex patterns. Simulated scattering from the reconstructed orientation field is shown to reproduce complex scattering patterns generated by the defected microstructure. Spatial variation of a goodness-of-fit or confidence metric associated with the optimized orientation field indicates regions of relatively high or low orientational disorder. An alignment procedure is used to match sample cross sections in the different strain states. The data and analysis methods point toward the ability to perform detailed comparisons between polycrystal plasticity computational model predictions and experimental observations of macroscopic volumes of material.

36 MATERIALS SCIENCE↗

Pulsed Joining Of Body-In-White Components

The objective of this project was to develop cost efficient high quality pulsed welding (PW) technology for joining 6xxx Aluminum and High Strength Steel (with tensile strength above 580MPa) components enabling broad usage of hydroformed parts and leading to substantial weight reduction of cars and trucks to reduce US demand on petroleum, lower carbon emissions and energy expenditures. In general, pulsed welding is a form of impact welding where two dissimilar metal pieces are joined by accelerating one to velocities exceeding 300m/s at which point the first piece strikes the second and forms a weld. In this work, two methods were used to accelerate the flyer material: Electro-Magnetic (EM) pulse and Electro-Hydraulic (EH) pulse launching. The advantage of pulsed welding techniques is that welds can be formed between two materials that cannot otherwise be welded: high strength aluminum and high strength steel. The technical objectives of the project included: 1) developing cost affordable production feasible tooling design for PW of 6xxx aluminum to High Strength steel with strengths above 580MPa; 2) demonstrating that fabricated joints can exceed the required service load strength initially at the coupon level and then at the component level; 3) developing fundamental understanding of the mechanisms of joint formation and conditions leading to formation of high quality PW joint; and 4) creating a numerical model predicting the tooling and electric discharge parameters necessary for the joint formation and that satisfy the targeted strength parameters. The project successfully developed: 1) EM and EH pulsed welds between high strength aluminum with tensile strengths exceeding 240MPa and steels exceeding 580MPa; 2) pulsed welds of extrusions with strengths exceeding project requirements; 3) EM and EH flyer launch models and 4) weld interface formation models. However, the grant holder, Ford Motor Company, could see no path to commercialization and the work was discontinued at the end of the first budget period.

36 MATERIALS SCIENCE↗

RAPID OPTIMAL SPH PARTICLE DISTRIBUTIONS IN SPHERICAL GEOMETRIES FOR CREATING ASTROPHYSICAL INITIAL CONDITIONS

Creating spherical initial conditions in smoothed particle hydrodynamics simulations that are spherically conformal is a difficult task. Here, we describe two algorithmic methods for evenly distributing points on surfaces that when paired can be used to build three-dimensional spherical objects with optimal equipartition of volume between particles, commensurate with an arbitrary radial density function. We demonstrate the efficacy of our method against stretched lattice arrangements on the metrics of hydrodynamic stability, spherical conformity, and the harmonic power distribution of gravitational settling oscillations. We further demonstrate how our method is highly optimized for simulating multi-material spheres, such as planets with core–mantle boundaries.

79 ASTRONOMY AND ASTROPHYSICS↗

Defects and Mechanical Behavior of Plutonium [Slides]

Defects are important because they heavily influence material properties (e.g. strength, ductility, elasticity, conductivity, phase transformation temperatures (melting point), corrosion resistance, etc.). At LANL defects in plutonium are being characterized using many different methods (e.g. EXAFS, XRD, microscopy, RUS, DSC, dilatometry, density, etc.) My goal is to introduce a complimentary method of understanding defects in δ-Pu using the mechanical microscope concept. Using well-developed theories of first principles strengthening mechanisms (i.e. how defects influence strength) and carefully designed experiments, mechanical testing can compliment other defect characterization tools.

36 MATERIALS SCIENCE↗

Multimodal Defect Imaging of Pure Tungsten Components Fabricated via Electron Beam Powder Bed Fusion

The utilization of additive manufacturing (AM) techniques for refractory materials in high-temperature environments has significantly expanded because of the ability to fabricate geometrically complex components. Electron beam powder bed fusion (EB-PBF), which provides lower residual stress, a cleaner vacuum environment, and better efficiency for high melting point, is one of the best-suited AM methods to produce advanced refractory components. However, the property variation attributed to the heterogeneous microstructure and process-induced defects has hindered the widespread adoption of EB-PBF-produced material like tungsten. While numerous in-situ monitoring and defect detection methods have been demonstrated for EB-PBF, a workflow that compares and evaluates process-induced abnormalities from different imaging perspectives is still limited. This study examines a feature-embedded tungsten component manufactured via the EB-PBF process to demonstrate the defect detection capabilities of a multimodal defect imaging workflow. The predefined and process-induced defects are evaluated by harnessing various imaging techniques, including in-situ electron imaging, layerwise near-infrared (NIR) imaging, post-build high-energy x-ray computed tomography (CT), and conventional destructive metallography. The results highlight the strengths and limitations of distinctive defect imaging techniques concerning specific defect types, sizes, and conditions. It was found that electron imaging can provide more abnormal detection capabilities while maintaining a higher measuring accuracy, against the conventional metallography in this case study, compared with NIR and CT imaging techniques.

36 MATERIALS SCIENCE↗

Crystal Graph Convolutional Neural Networks for an Accurate and Interpretable Prediction of Material Properties

The use of machine learning methods for accelerating the design of crystalline materials usually requires manually constructed feature vectors or complex transformation of atom coordinates to input the crystal structure, which either constrains the model to certain crystal types or makes it difficult to provide chemical insights. Here, we develop a crystal graph convolutional neural networks framework to directly learn material properties from the connection of atoms in the crystal, providing a universal and interpretable representation of crystalline materials. Our method provides a highly accurate prediction of density functional theory calculated properties for eight different properties of crystals with various structure types and compositions after being trained with 10 4 data points. Further, our framework is interpretable because one can extract the contributions from local chemical environments to global properties. Using an example of perovskites, we show how this information can be utilized to discover empirical rules for materials design.

36 MATERIALS SCIENCE↗

Laser interferometric method for determining the carrier diffusion length in semiconductors

A new laser interferometric method for measuring the carrier diffusion length in semiconductors is proposed. The method is based on the interference–absorption interaction of two laser radiations in a semiconductor. Injected radiation generates additional carriers in a semiconductor, which causes a change in the material’s optical constants and modulation of the probing radiation passed through the sample. When changing the distance between carrier generation and probing points, a decrease in the carrier concentration, which depends on the diffusion length, is recorded. The diffusion length is determined by comparing the experimental and theoretical dependences of the probe signal on the divergence of the injector and probe beams. The method is successfully tested on semiconductor samples with different thicknesses and surface states and can be used in scientific research and the electronics industry.

36 MATERIALS SCIENCE↗

Development of and initial assessment of microstructurally engineered UN

Fuels with high uranium densities have been considered in the Nuclear Technology Research and Development program’s Advanced Fuels Campaign as potential replacements for uranium(IV) oxide in commercial light water reactors. One such candidate fuel is uranium mononitride, UN, which has been observed to readily oxidize in steam and simulated pressurized water reactor conditions. Thus, it is important to examine methods for waterproofing UN, especially for potential cladding breach scenarios. This can be achieved by controlling the microstructure so as to prevent contact between the UN fuel and coolant. Research so far this FY has focused on screening potential candidate additive materials to control UN microstructure using steam oxidation TGA. From these candidates, yttrium was selected based on corrosion resistance, which led to attempts to develop a method for liquid phase sintering of yttrium with UN. Yttrium in the form of yttrium dihydride (YH 2 ) was mixed with UN, pressed, and heated to temperatures above the melting point of Y metal to dehydride the material and then melt it to enable liquid phase sintering. Results showed no indication of densification, but did show chemical interaction between Y and UN, resulting in the formation of yttrium nitride (YN) and uranium metal. These observations were used to develop a better understanding of microstructure control for UN waterproofing to be addressed in an L2 milestone that is an FY19 deliverable (M2FT-19LA020201021).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

This dissertation demonstrates the first of its kind distributed magnetic field sensor based on a fiber optic distributed acoustic sensing (DAS) scheme. Ferromagnetic nickel and Metglas® were dispersed internally within a fiber optic preform and then drawn on an in-house fiber optic draw tower to lengths in the kilometers. Due to the close proximity of the ferromagnetic metals and fiber optic core, the magnetostrictive strain response of the ferromagnetic materials when exposed to a magnetic field would perturbate within the fiber cladding and transfer that strain, internally, to the fiber optic core. Strain resulting from the magnetostrictive effect allows the DAS based sensor to accurately translate strain into readable magnetic field data. Due to the high sensitivity seen in this sensor design, multiparameter sources, acoustic and magnetic fields, were tested and validated and a three dimensional magnetic-field vector sensor was proposed. Numerical analysis of the novel sensor design was first implemented using COMSOL Multiphysics, where inputs such as magnetostrictive element shape, size, distance, and number were first investigated. Upon optimizing system constraints, the sensor design was further modified such that single mode operation was consistent across multiple fiber draws while retaining high strain transfer from the ferromagnetic elements to the fiber optic core. Ferromagnetic material selection was evaluated as a function of the saturation magnetostriction constants and a total of 4 modules were used to fully characterize the complex physics involved in this sensor design. All fabrication and testing were performed in-house using a full scale 3-story fiber draw tower and custom environmental testing stations to imitate naturally occurring events such as magnetic or acoustic point sources. A unique stacking method was used to embed ferromagnetic nickel and Metglas® into a fiber optic preform which when combined with a custom fiber draw process resulted in consistent multi-material fibers drawn to lengths of 1-km. In-house testing facilities included different types of electromagnetic generators, in addition to a soil test bed, and an outdoor test bed which allowed 100 meters of fiber to be tested simultaneously. All tested sensors demonstrated high strain transfer capabilities on the order of 0.01-10 μϵ depending on the materials used, ferromagnetic rod number, and core to metal spacing. Due to the sensitivity of the system the difference between AC and DC was distinct, and directional magnetostriction was studied. Transverse and longitudinal magnetic wave propagation was controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength and distance. To summarize, this dissertation explores the first fully distributed magnetic field sensor using DAS based techniques and one of the first multi-material fiber draw processes which can produce consistent single mode fiber up to 1-km. Due to extensive FEA modeling, multiple iterations of the magnetic sensor were fully characterized and an equation describing the relationship between sensor design and strain transfer has been created and validated experimentally. Multi-parameter tests including acoustic and magnetic fields were implemented and an algorithm was developed to separate the mixed signals. Finally, a test was performed to demonstrate the feasibility of sensing magnetic fields directionally. Cumulative results demonstrate a high-quality sensor alternative to current designs which may surpass other magnetic sensors due to innate multi-parameter capabilities, in addition to the inexpensive production cost and extremely long operating lengths.

02 PETROLEUM↗

Synthesis and electrochemical performance of Li{sub 1+x}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} (0 {<=} x {<=} 0.15) cathode materials for lithium-ion batteries

Graphical abstract: Cycle behavior of Li{sub 1+x}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} cells (x = 0, 0.05, 0.10 and 0.15) obtained during cycling within the potential of 2.5-4.3 V. Highlights: Black-Right-Pointing-Pointer The spherical Li{sub 1+x}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} were synthesized by coprecipitation method. Black-Right-Pointing-Pointer Excess lithium improved the electrochemical performance. Black-Right-Pointing-Pointer Li{sub 1.10}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} showed the best electrochemical performance. Black-Right-Pointing-Pointer Li{sub 1.10}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} had the lowest charge transfer resistance. -- Abstract: In this work, layered lithium-excess materials Li{sub 1+x}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} (x = 0, 0.05, 0.10 and 0.15), of spherical morphology with primary nanoparticles assembled in secondary microspheres, were synthesized by a coprecipitation method. The effects of lithium content on the structure and electrochemical performance of these materials were evaluated by employing X-ray diffraction (XRD), inductive coupled plasma (ICP), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and galvanostatic charge/discharge tests. It is found that Li{sub 1.10}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}}, i.e., Li[(Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}){sub 0.95}Li{sub 0.05}]O{sub 2} showed the best electrochemical performance due to the highly ordered layered structure, reduced cation mixing and the lowest charge transfer resistance. Li{sub 1.10}Ni{sub 0.5}Mn{sub 0.3}Co{sub 0.2}O{sub 2+{delta}} delivered a discharge capacity of 145 mA h g{sup -1} at 125 mA g{sup -1} in the cut-off voltage of 2.5-4.3 V, and had a capacity retention of 100% after 50 cycles at room temperature.

36 MATERIALS SCIENCE↗