Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Lightweight Integrated Optical Sensor for Atmospheric Measurements on Mobile Platforms

The goal of the Phase I program was to develop a novel open path sensor platform technology based on integration of semiconductor waveguides with efficient optoelectronic components on a monolithic platform. The successful Phase I effort resulted in demonstration of a novel optical resonator structure based on semiconductor high contrast gratings (HCGs) that will enable implementation of an ultra-compact, low-power gas sensor suitable for use on mobile platforms. Extensive numerical modeling was performed to design a device optimized for measuring CO2 at a wavelength for which a laser was available for proof of concept. Devices were fabricated and tested to match the target wavelength, angle, and operating temperature. This demonstration is the first implementation of HCGs at the wavelengths of interest and shows the flexibility of the proposed architecture for gas sensing applications. The measured cavity Q was lower than anticipated due to fabrication process challenges. The PSI and UC Berkeley team has identified solutions to these challenges and will produce optimized devices in a Phase II program where a prototype sensor will be fabricated and tested.

54 ENVIRONMENTAL SCIENCES↗

In-vessel design of ITER diagnostic neutron activation system

A neutron activation system utilizing an encapsulated metal sample technique will be implemented to evaluate total fusion power from ITER plasma. The positions of seven irradiation ends for each poloidal section are determined to optimize the measurements from asymmetric, elongated plasma with minimum uncertainty. To determine the exact location of the irradiation end, some physical and technical aspects for each location are investigated. Monte Carlo neutronic calculations are performed to assess the physical characteristics and optimize the design of each irradiation end.

36 MATERIALS SCIENCE↗

Centrality determination with a forward detector in the RHIC Beam Energy Scan

Recently, Chatterjee et al [1] used a hadronic transport model to estimate the resolution with which various experimental quantities select the impact parameter of relativistic heavy ion collisions at collision energies relevant to the Beam Energy Scan (BES) program at the Relativistic Heavy Ion Collider (RHIC). Measures based on particle multiplicity at forward rapidity were found to be significantly worse than those based on midrapidity multiplicity. Using the same model, we show that a slightly more sophisticated measure greatly improves the resolution based on forward rapidity particles; this improvement persists even when the model is filtered through a realistic simulation of a recent upgrade detector to the STAR experiment. Furthermore, these results highlight the importance of optimizing centrality measures based on particles detected at forward rapidity, especially for experimental studies that search for a critical point in the QCD phase diagram. Such measurements usually focus on proton multiplicity fluctuations at midrapidity, hence selecting events based on multiplicity at midrapidity raises the possibility of nontrivial autocorrelations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hot Coordinate Measuring Machine Technical Specifications and Requirements (U)

The goal of this document is to outline the technical specifications and requirements for a new Hot Coordinate Measuring Machine at TA-55. This document should be used in conjunction with the information provided from TA-55 Hot CMM Location Study and TA-55 Hot CMM Technology Assessment. All three documents will guide the user to the optimal coordinate measuring machine selection.

42 ENGINEERING↗

Hot Coordinate Measuring Machine Technology Assessment (U)

The goal of this report is to document a technology assessment performed following the guidance created by LA-UR-13-22870, “Hot Coordinate Measuring Machine Technical Specifications and Requirements (U)”. The intent was to capture specific values for technical specifications and requirements listed by the guide and assign a weight factors based on TA-55 importance. After the information was obtained, an optimal coordinate measuring machine for TA-55 was revealed – Hexagon’s Leitz Reference Xi 15.9.7. An internal look at on-site technology revealed that the current Hot CMM (Xcel 765) has the worst performance specification or accuracy statement of all CMMs currently at LANL. A look at Quindos license file options revealed that while most machines appear to have a standard set of options, some machines appear to be missing options and may contain unneeded ones. Controller firmware versions also appear to not be standardized at this time.

42 ENGINEERING↗

Radiometric and spectral stray light correction for the Portable Remote Imaging Spectrometer (PRISM) coastal ocean sensor

The airborne Portable Remote Imaging Spectrometer (PRISM) instrument is based on a fast (F/1.8) Dyson spectrometer operating at 350-1050 nm and a two-mirror telescope combined with a Teledyne HyViSI 6604A detector array. Raw PRISM data contain electronic and optical artifacts that must be removed prior to radiometric calibration. We provide an overview of the process transforming raw digital numbers to calibrated radiance values. Electronic panel artifacts are first corrected using empirical relationships developed from laboratory data. The instrument spectral response functions (SRF) are reconstructed using a measurement-based optimization technique. Removal of SRF effects from the data improves retrieval of true spectra, particularly in the typically low-signal near-ultraviolet and near-infrared regions. As a final step, radiometric calibration is performed using corrected measurements of an object of known radiance. Implementation of the complete calibration procedure maximizes data quality in preparation for subsequent processing steps, such as atmospheric removal and spectral signature classification.

Thompson, David R.↗

Pseudo-gray-scale halftone gratings for shearing and Hartmann wavefront sensors

Now in use on x-ray beamlines worldwide, shearing interferometry and Hartmann wavefront sensing provide effective feedback for measuring and optimizing high-quality beams. Conventionally, both approaches spatially modulate the beam properties (amplitude or phase) using two-tone, binary patterns, leading to deleterious diffraction effects that must be mitigated. In shearing, the presence of multiple diffraction orders affects measurement near boundaries. In Hartmann, diffraction limits the measurement point density. We demonstrate that the use of pseudo-gray-scale halftone patterns in the diffracting elements can improve the performance of both techniques.

47 OTHER INSTRUMENTATION↗

Direct Measurement of the Spectral Structure of Cosmic-Ray Electrons+Positrons in the Tev Region With Calet on the International Space Station

Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. The instrument, consisting of a charge detector, an imaging calorimeter, and a total absorption calorimeter with a total depth of 30 radiation lengths at normal incidence and a fine shower imaging capability, is optimized to measure the all-electron spectrum well into the TeV region. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10 5 ), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from −3.15 to −3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron+positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.

O. Adriani↗

Energy-dependent optimization of the prompt fission neutron spectrum with CGMF

Throughout the course of FY21, significant effort was put into investigating models within the LANL developed Hauser-Feshbach fission fragment decay code, CGMF, to understand and potentially solve the long-standing challenge of a too-soft prompt fission neutron spectrum, PFNS. Several inputs and models to CGMF were investigated, including the discrete nuclear levels, the optical model potential, level densities, and the fission fragment initial conditions. Some of the global models within CGMF led to a slight hardening of the neutron spectrum—particularly the likely incomplete discrete levels in through which γ-rays decay—but none of the changes where large enough for the tail of the PFNS to reproduce experimental data. A significant hardening of the spectrum tail was observed when the fission fragment initial conditions were optimized based on their sensitivities to the PFNS data for thermal incident neutrons. In this way, the parameters for the CGMF mass and total kinetic energy distributions, along with the spin cutoff factor were adjusted to better reproduce the experimental PFNS measurements. This optimization hardened the tail of the PFNS slightly but led to unphysical mass distributions for the fission fragments before neutron emission. It was clear from the above that we do not expect to be able to produce an evaluation-quality PFNS with CGMF in the near future. Challenges at thermal will persist–and possibly worsen–with increasing incident energy, where more models are needed to completely describe the fission. Basic-science research funding exceeding the amount available and scope of our NCSP funds would be needed to tackle this decade-long challenge impacting many fission-fragment event generator. And, in fact, Amy Lovell won LDRD ECR funding to do so over the next few years. Therefore, we focused in FY22 on extending evaluation capabilities beyond thermal incident neutrons, to take into account the incident energy dependence of the PFNS and fission fragment initial condition distributions in CGMF. We chose to set up the evaluation methodology to perform PFNS evaluations with CGMF across incident-neutron energies, in order to have it readily available for future NCSP evaluations when the PFNS from CGMF has improved. In this report, we outline the evaluation methodology, along with the results of the optimization, including full model calculations with CGMF using the evaluated parameters.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Contrast-enhanced spectral mammography with a photon-counting detector

Purpose: Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved absorption imaging was studied. Methods: A framework for system characterization was set up that included quantum and anatomical noise and a theoretical model of the system was benchmarked to phantom measurements. Results: Optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging in the phantom study. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, yielded only a minute improvement. In a simulation of a clinically more realistic case, spectral imaging was predicted to perform approximately 30% better than absorption imaging for an average glandularity breast with an average level of anatomical noise. For dense breast tissue and a high level of anatomical noise, however, a rise in detectability by a factor of 6 was predicted. Another {approx}70%-90% improvement was found to be within reach for an optimized system. Conclusions: Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. Inclusion of anatomical noise is essential for optimizing spectral imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved spacecraft radio science using an on-board atomic clock: Application to gravitational wave searches

Recent advances in space-qualified atomic clocks (low-mass, low power-consumption, frequency stability comparable to that of ground-based clocks) can enable interplanetary spacecraft radio science experiments at unprecedented Doppler sensitivities. The addition of an on-board digital receiver would allow the up- and down-link Doppler frequencies to be measured separately. Such separate, high-quality measurements allow optimal data combinations that suppress the currently leading noise sources: phase scintillation noise from the Earth's atmosphere and Doppler noise caused by mechanical vibrations of the ground antenna. Here we provide a general expression for the optimal combination of ground and on-board Doppler data and compute the sensitivity such a system would have to low-frequency gravitational waves (GWs). Assuming a plasma scintillation noise calibration comparable to that already demonstrated with the multilink CASSINI radio system, the space-clock/digital-receiver instrumentation enhancements would give GW strain sensitivity of 3.7x10{sup -14} Hz{sup -1/2} for randomly polarized, monochromatic GW signals isotropically distributed over the celestial sphere, over a two-decade ({approx}0.0001-0.01 Hz) region of the low-frequency band. This is about an order of magnitude better than currently achieved with traditional two-way coherent Doppler experiments. The utility of optimally combining simultaneous up- and down-link observations is not limited to GW searches. The Doppler tracking technique discussed here could be performed at minimal incremental cost to improve also other radio science experiments (i.e., tests of relativistic gravity, planetary and satellite gravity field measurements, atmospheric and ring occultations) on future interplanetary missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement and Simulation of the Magnetic Fields from a 555 Timer Integrated Circuit Using a Quantum Diamond Microscope and Finite-Element Analysis

Quantum diamond microscope (QDM) magnetic field imaging is an emerging interrogation and diagnostic technique for integrated circuits (ICs). To date, the ICs measured with a QDM have been either too complex for us to predict the expected magnetic fields and benchmark the QDM performance or too simple to be relevant to the IC community. In this paper, we establish a 555 timer IC as a “model system” to optimize QDM measurement implementation, benchmark performance, and assess IC device functionality. To validate the magnetic field images taken with a QDM, we use a spice electronic circuit simulator and finite-element analysis (FEA) to model the magnetic fields from the 555 die for two functional states. Furthermore, we compare the advantages and the results of three IC-diamond measurement methods, confirm that the measured and simulated magnetic images are consistent, identify the magnetic signatures of current paths within the device, and discuss using this model system to advance QDM magnetic imaging as an IC diagnostic tool.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of an Automatic Registration-Based Algorithm for Direct Measurement of Volume Change in Tumors

Purpose: Assuming that early tumor volume change is a biomarker for response to therapy, accurate quantification of early volume changes could aid in adapting an individual patient's therapy and lead to shorter clinical trials. We investigated an image registration-based approach for tumor volume change quantification that may more reliably detect smaller changes that occur in shorter intervals than can be detected by existing algorithms. Methods and Materials: Variance and bias of the registration-based approach were evaluated using retrospective, in vivo, very-short-interval diffusion magnetic resonance imaging scans where true zero tumor volume change is unequivocally known and synthetic data, respectively. The interval scans were nonlinearly registered using two similarity measures: mutual information (MI) and normalized cross-correlation (NCC). Results: The 95% confidence interval of the percentage volume change error was (-8.93% to 10.49%) for MI-based and (-7.69%, 8.83%) for NCC-based registrations. Linear mixed-effects models demonstrated that error in measuring volume change increased with increase in tumor volume and decreased with the increase in the tumor's normalized mutual information, even when NCC was the similarity measure being optimized during registration. The 95% confidence interval of the relative volume change error for the synthetic examinations with known changes over {+-}80% of reference tumor volume was (-3.02% to 3.86%). Statistically significant bias was not demonstrated. Conclusion: A low-noise, low-bias tumor volume change measurement algorithm using nonlinear registration is described. Errors in change measurement were a function of tumor volume and the normalized mutual information content of the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studying the MLT by a Combined Analysis of SABER/TIMED and Lidar Measurements

The SABER instrument on board the TIMED Satellite is a limb scanning infrared radiometer designed to measure temperature and minor constituent vertical profiles and energetics parameters in the mesosphere and lower thermosphere (MLT). The measurements have been performed continuously since January 25, 2002 to provide excellent coverage for both hemispheres. The Leibniz-Institute of Atmospheric Physics (LAP) at Kuehlungsborn, Germany (54N, 12E) operates two lidar instruments, using three different temperature measurement methods, optimized for three altitude ranges. The total altitude range of the lidar installation lies from 1 to 105 km. Another instrument used for intercomparison is the ALOMAR RMR lidar, located at Andoya, Norway (69N, 16E). We have searched the SABER and lidar datasets for coincidental common volume measurements within plus or minus 1 degree in latitude, plus or minus 2 degrees in longitude and approx. 1 hour in time for the sake of (a) comparison of measured temperatures; (b) validation of the models used in SABER data analysis; and (c) extracting new information about MLT parameters. In this work we applied the non-LTE ALI-ARMS code designed to calculate the nonequilibrium radiance in different viewing geometries to the analysis of measurements which satisfied these search criteria. The results of this analysis (a) support the application of higher value of CO2-O quenching rate (6e-12 cubic centimeters per second) by the non-LTE temperature retrievals from the SABER 15 micrometer limb radiance data, and (b) demonstrate the importance of accounting for the vibrational-vibrational energy exchange among the CO2 isotopes for accurate temperature retrievals. Using temperature profiles obtained in lidar measurements as inputs for the retrieval algorithm we also retrieved the nighttime CO2 densities from the SABER 15 micrometer limb radiances and compared them with the model and climatology CO2 data used in the SABER nighttime temperature retrievals.

Feofilov, A. G.↗

The LHCf experiment

The Large Hadron Collider forward (LHCf) experiment has performed measurements of the neutral particles emitted to the very forward region of proton-proton collisions at LHC. This experiment is designed to explore very forward interaction at very high energy, which is relevant to interpretation of the data from cosmic-ray experiments. LHCf detector is well optimized to measure photons in the multi-TeV energy range, and to reconstruct neutral pions with two photons. It can also measure neutrons. The data acquisitions at 0.9 TeV and 7 TeV were completed in 2010. In this paper, single photon energy spectra obtained at 0.9 TeV and transverse energy spectra of neutral pions obtained at 7 TeV will be presented. The results are compared with expectations by hadronic interaction models used for air-shower simulations. We found none of these models agree with the obtained data in the photon energy spectra, while EPOS shows a good agreement in the transverse energy spectra of neural pions. Impacts on cosmic-ray and QCD physics are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations of the LHC high luminosity monitors at beam energies from 3.5 TeV to 7.0 TeV

We have constructed two pairs of fast ionization chambers (BRAN) for measurement and optimization of luminosity at IR1 and IR5 of the LHC. These devices are capable of monitoring the performance of the LHC at low luminosity 10{sup 28} cm{sup -2}s{sup -1} during beam commissioning all the way up to the expected full luminosity of 10{sup 34} cm{sup -2}s{sup -1} at 7.0 TeV. The ionization chambers measure the intensity of hadronic/electromagnetic showers produced by the forward neutral particles of LHC collisions. To predict and improve the understanding of the BRAN performance, we created a detailed FLUKA model of the detector and its surroundings. In this paper, we describe the model and the results of our simulations including the detector's estimated response to pp collisions at beam energies of 3.5, 5.0, and 7.0 TeV per beam. In addition, these simulations show the sensitivity of the BRAN to the crossing angle of the two LHC beams. It is shown that the BRAN sensitivity to the crossing angle is proportional to the measurement of crossing angle by the LHC beam position monitors.

43 PARTICLE ACCELERATORS↗

Anisotropic hot deformed magnets prepared from Zn-coated MRE-Fe-B ribbon powder

Milled melt-spun ribbon flake of MRE-Fe-B coated with Zn coating using a vapor transport technique was found to have significant increase in coercivity without degrading the magnetization when the Zn thickness and heat treatment were optimized. Magnetic measurements show that 0.5–1 wt. % Zn coating increases the coercivity about 1 kOe over the initial ribbon powder. After vacuum hot deformation (VHD), the VHD magnet with Zn coating of 0.5 wt. % results in a nearly 3 kOe higher coercivity than an un-coated alloy magnet. An optimized VHD magnet with 0.5 wt. % Zn coating obtains a coercivity of 11.2 kOe and (BH)max of 23.0 MGOe, respectively. SEM and TEM microstructures analysis demonstrates that the Zn coating on the surface of ribbon powder has diffused along the intergranular boundaries after the ribbon powder was annealed at 750 °C for 30 min or was hot deformed at 700–750 °C.

36 MATERIALS SCIENCE↗