Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Characterization of Strategies for Obtaining Confident Identifications in Bottom-Up Proteomics Measurements Using Hybrid FTMS instruments

Hybrid FTMS instruments, such as the LTQ-FTTM and LTQ-OrbitrapTM, are capable of generating fast duty cycle linear ion trap MS/MS data along with high resolution information without compromising the overall throughput of measurements. Combined with online LC separations, these instruments represent powerful and flexible tools for proteomics research. In the present work, we explore strategies for high throughput, high coverage proteomics measurements using hybrid FTMS instruments. Our accurate mass and time tag (AMT tag) strategy enables identification of thousands of peptides in a single LC-FTMS analysis by comparing accurate molecular mass and LC elution time information from the analysis to a reference database. An alternative strategy considered here employs linear ion trap (low resolution) MS/MS identifications generated by an appropriate search engine, such as SEQUEST; the high resolution precursor ion spectra were used to refine the MS/MS identifications, an approach termed Accurate Precursor Mass Filter (APMF). The APMF results can be additionally filtered using the LC elution time information from the AMT tag database, which constitutes a Precursor Mass and Time Filter (PMTF), the third approach implemented in this study. Both the APMF and the PMTF approaches are evaluated for coverage and confidence of peptide identifications and contrasted with the current AMT tag strategy. Two separate methodologies were used to reliably quantify identification confidence: a commonly used decoy database method and an alternative method based on the mass accuracy histogram. The two methodologies produced consistent results, confirming the validity of the identification confidence evaluations. Comparison of the three approaches has shown that the AMT tag data analysis approach may be preferential for studies giving a priority to the highest achievable coverage. The APMF approach by itself does not require AMT tag database and provides a moderate coverage combined with acceptable confidence values of ~99%.The PMTF approach yielded a significantly better peptide identification confidence, >99.9%, that essentially excluded any false peptide identifications. The results suggest that even with a perfect peptide ID (0% FDR in the peptide MS/MS database), the peak matching FDR is a function of the database size, so smaller high confidence databases are the goal. Thus a combined strategy can implement multi-pass APMF approach to generate high confidence AMT tag databases, which can be then validated using PMTF approach; the compact high quality databases will be used for subsequent high-throughput, high coverage AMT tag studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shape Evolution of C75 Large-Grain Niobium Half-Cells During Cavity Fabrication

The largely anisotropic deformation of large-grain Nb discs during deep drawing into half-cells poses a challenge for achieving a desired shape accuracy. Two 5-cell cavities for the C75 CEBAF cryomodule rework program have been fabricated at Jefferson Lab from large-grain Nb discs directly sliced from an ingot. The shape of the inner surface of eight half-cells has been inspected using a FARO Edge laser scanner during the fabrication process and compared to the reference shape. On average, approximately 63% of the half-cell inner surface was found to be within 0.1 mm of the reference shape and ~90% to be within 0.2 mm, after the final equator machining. Several 5-cell C75 cavities have also been fabricated at Research Instruments, Germany, and measurements of the shape accuracy using a Zeiss 3D coordinate measuring machine gave similar results. One half-cell was measured both at Research Instruments and Jefferson Lab for comparison.

Ciovati, G.↗

New capability for neutron transmission measurements at LANSCE: The DICER instrument

A new capability for neutron transmission measurements has been developed at the Los Alamos Neutron Science Center (LANSCE). The DICER (Device for Indirect Capture Experiments on Radionuclides) instrument is designed to tightly constrain neutron-capture cross sections for short-lived radionuclides that are beyond the reach of direct techniques, via measurement and analysis of neutron transmission resonances on these same radionuclides. The innovative DICER apparatus enables simultaneous sample-in and sample-out measurements, thus minimizing the amount of sample material needed and reducing the measurements time by half. A description of the current status of the new transmission station, along with a performance overview and results from known reactions, will be presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Smart System for the Contactless Measurement of Energy Expenditure

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO 2 production, VCO 2 (mL/min), and/or O 2 consumption, VO 2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO 2 from a room’s ambient CO 2 concentration transients was evaluated. Resting EE (REE) and exercise VCO 2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO 2 and λ for CO 2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO 2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

47 OTHER INSTRUMENTATION↗

Electron temperature and density probe for small aeronomy satellites

A compact and low power consumption instrument for measuring the electron density and temperature in the ionosphere has been developed by modifying the previously developed Electron Temperature Probe (ETP). A circuit block which controls frequency of the sinusoidal signal is added to the ETP so that the instrument can measure both T{sub e} in low frequency mode and N{sub e} in high frequency mode from the floating potential shift of the electrode. The floating potential shift shows a minimum at the upper hybrid resonance frequency (f{sub UHR}). The instrument which is named “TeNeP” can be used for tiny satellites which do not have enough conductive surface area for conventional DC Langmuir probe measurements. The instrument also eliminates the serious problems associated with the contamination of satellite surface as well as the sensor electrode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CU 2-D-MAX-DOAS instrument – Part 2: Raman scattering probability measurements and retrieval of aerosol optical properties

Abstract. The multiannual global mean of aerosol optical depth at 550 nm (AOD550) over land is ∼ 0.19, and that over oceans is ∼ 0.13. About 45 % of the Earth surface shows AOD550 smaller than 0.1. There is a need for measurement techniques that are optimized to measure aerosol optical properties under low AOD conditions. We present an inherently calibrated retrieval (i.e., no need for radiance calibration) to simultaneously measure AOD and the aerosol phase function parameter, g, based on measurements of azimuth distributions of the Raman scattering probability (RSP), the near-absolute rotational Raman scattering (RRS) intensity. We employ radiative transfer model simulations to show that for solar azimuth RSP measurements at solar elevation and solar zenith angle (SZA) smaller than 80°, RSP is insensitive to the vertical distribution of aerosols and maximally sensitive to changes in AOD and g under near-molecular scattering conditions. The University of Colorado two-dimensional Multi-AXis Differential Optical Absorption Spectroscopy (CU 2-D-MAX-DOAS) instrument was deployed as part of the Two Column Aerosol Project (TCAP) at Cape Cod, MA, during the summer of 2012 to measure direct sun spectra and RSP from scattered light spectra at solar relative azimuth angles (SRAAs) between 5 and 170°. During two case study days with (1) high aerosol load (17 July, 0.3 < AOD430 < 0.6) and (2) near-molecular scattering conditions (22 July, AOD430 < 0.13) we compare RSP-based retrievals of AOD430 and g with data from a co-located CIMEL sun photometer, Multi-Filter Rotating Shadowband Radiometer (MFRSR), and an airborne High Spectral Resolution Lidar (HSRL-2). The average difference (relative to DOAS) for AOD430 is +0.012 ± 0.023 (CIMEL), −0.012 ± 0.024 (MFRSR), −0.011 ± 0.014 (HSRL-2), and +0.023 ± 0.013 (CIMELAOD − MFRSRAOD) and yields the following expressions for correlations between different instruments: DOASAOD = −(0.019 ± 0.006) + (1.03 ± 0.02) × CIMELAOD (R2 = 0.98), DOASAOD = −(0.006 ± 0.005) + (1.08 ± 0.02) × MFRSRAOD (R2 = 0.98), and CIMELAOD = (0.013 ± 0.004) + (1.05 ± 0.01) × MFRSRAOD (R2 = 0.99). The average g measured by DOAS on both days was 0.66 ± 0.03, with a difference of 0.014 ± 0.05 compared to CIMEL. Active steps to minimize the error in the RSP help to reduce the uncertainty in retrievals of AOD and g. As AOD decreases and SZA increases, the RSP signal-to-noise ratio increases. At AOD430 ∼ 0.4 and 0.10 the absolute AOD errors are ∼ 0.014 and 0.003 at 70° SZA and 0.02 and 0.004 at 35° SZA. Inherently calibrated, precise AOD and g measurements are useful to better characterize the aerosol direct effect in urban polluted and remote pristine environments.

54 ENVIRONMENTAL SCIENCES↗

Automated tape-target centering based on template matching for construction measurement tasks using robotic total station

Robotic total stations have transformed surveying and construction mapping through precise, efficient, and automated measurements. These instruments integrate a theodolite, which measures horizontal and vertical angles, with an electronic distance measurement (EDM) unit to determine distances, allowing accurate 3D measurement of observable points. Traditionally, users manually aimed the total station at a target. Recent advancements in robotic motor control and integration of cameras now enable automatic rotation and aiming, typically requiring only a single operator to position the target. Automated aiming is commonly performed using retroreflector prisms, which reflect light back to the source with minimal scattering, enabling high-precision measurements over long distances. However, retroreflectors, especially those designed for 360 degree, can be expensive and impractical for certain applications. This paper presents an algorithm for automating the center detection of low-cost disposable tape targets using the total station's onboard camera and a template matching algorithm. The algorithm identifies the target's center pixel in the image, and the instrument is commanded to aim at that location. We evaluated the performance of this template-matching-based centering method under various distances, angles, lighting conditions, and field environments, comparing its results to both manual aiming and conventional automated aiming of tape targets. Manual aiming was used as the baseline operational reference in the absence of an independent ground-truth measurement. The proposed approach achieves target centering results comparable to the manual baseline. This method provides a cost-effective alternative for high-precision applications where retroreflector targets are constrained by budget or logistics.

Harrington, Joshua [ORNL]↗

Photoacoustic infrared spectroscopy for conducting gas tracer tests and measuring water saturations in landfills

Highlights: Black-Right-Pointing-Pointer Photoacoustic infrared spectroscopy tested for measuring tracer gas in landfills. Black-Right-Pointing-Pointer Measurement errors for tracer gases were 1-3% in landfill gas. Black-Right-Pointing-Pointer Background signals from landfill gas result in elevated limits of detection. Black-Right-Pointing-Pointer Technique is much less expensive and easier to use than GC. - Abstract: Gas tracer tests can be used to determine gas flow patterns within landfills, quantify volatile contaminant residence time, and measure water within refuse. While gas chromatography (GC) has been traditionally used to analyze gas tracers in refuse, photoacoustic spectroscopy (PAS) might allow real-time measurements with reduced personnel costs and greater mobility and ease of use. Laboratory and field experiments were conducted to evaluate the efficacy of PAS for conducting gas tracer tests in landfills. Two tracer gases, difluoromethane (DFM) and sulfur hexafluoride (SF{sub 6}), were measured with a commercial PAS instrument. Relative measurement errors were invariant with tracer concentration but influenced by background gas: errors were 1-3% in landfill gas but 4-5% in air. Two partitioning gas tracer tests were conducted in an aerobic landfill, and limits of detection (LODs) were 3-4 times larger for DFM with PAS versus GC due to temporal changes in background signals. While higher LODs can be compensated by injecting larger tracer mass, changes in background signals increased the uncertainty in measured water saturations by up to 25% over comparable GC methods. PAS has distinct advantages over GC with respect to personnel costs and ease of use, although for field applications GC analyses of select samples are recommended to quantify instrument interferences.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Novel Optical Instrument for On-Line Measurement of Particle Size Distribution—Application to Clean Coal Technologies

A flow cell is a critical measurement interface for many optical instruments. However, the flows are often sampled under harsh conditions, such as under high pressure and/or high temperature, in the presence of particles, moisture, vapors with high dew points or corrosive gases. Therefore, obtaining a high-optical-quality flow cell that does not perturb the measurement is a significant challenge. To address this challenge, we proposed a new flow cell that employs a unique laminar coaxial flow field (for the purge and sample flows). A test system was built to conduct particle size distribution (PSD) measurements with no sampling bias using a state-of-the-art analyzer (Malvern Panalytical Insitec). The results revealed that the measurement zone is well defined solely by the sample flow, and the optical windows are well protected by the purge flow, with minimal risk of any depositions from the sample flow. Using this flow cell, the Insitec can successfully measure PSD under high pressure and temperature under moist, corrosive conditions without generating any sampling bias. Importantly, we successfully applied this flow cell for on-line PSD measurement for the flue gas of a 100 kWth pressurized oxy-coal combustor operating at 15 bara.

Cheng, Mao (ORCID:0000000213273900)↗

Innovative sensing technologies for nuclear instrumentation

The Idaho National Laboratory (INL) is engaged in research and development activities for the development of nuclear instrumentation that contribute to advances in measurement methodologies, measurement systems, instrumentation, and sensors in the area of nuclear engineering. The activities described in this paper are centered on the INL Measurement Science Department, which was formed in 2018. Their mission is to develop instrumentation that provides real time, accurate, spatially resolved information regarding test conditions and the performance of fuels and materials during irradiation. This paper describes the integration of innovative optical fiber, acoustic and electrical impedance sensing technologies and measurement techniques as part of the activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Indirect evidence for Levy walks in squeeze film damping

Molecular flow gas damping of mechanical motion in confined geometries, and its associated noise, is important in a variety of fields, including precision measurement, gravitational wave detection, and microelectromechanical systems devices. We used two torsion balance instruments to measure the strength and distance-dependence of 'squeeze film' damping. Measured quality factors derived from free decay of oscillation are consistent with gas particle superdiffusion in Levy walks and inconsistent with those expected from traditional Gaussian random walk particle motion. The distance-dependence of squeeze film damping observed in our experiments is in agreement with a parameter-free Monte Carlo simulation. The squeeze film damping of the motion of a plate suspended a distance d away from a parallel surface scales with a fractional power between d{sup -1} and d{sup -2}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atmospheric Radiation Measurement Climate Research Facility (ACRF Instrumentation Status: New, Current, and Future)

The purpose of this report is to provide a concise but comprehensive overview of Atmospheric Radiation Measurement Climate Research Facility instrumentation status. The report is divided into the following four sections: (1) new instrumentation in the process of being acquired and deployed, (2) existing instrumentation and progress on improvements or upgrades, (3) proposed future instrumentation, and (4) Small Business Innovation Research instrument development.

54 ENVIRONMENTAL SCIENCES↗

Probing equilibrium of molecular and deprotonated water on TiO 2 (110)

Significance Understanding how water binds and dissociates on surfaces has broad implications in a vast range of physical and chemical processes. The relative stability of molecularly and dissociatively bound water has been debated for decades on many oxide surfaces, but it has never been successfully measured. Our study describes unique instrumentation, direct measurements, and a state-of-the-art computation and theory approach that yield a detailed kinetic and dynamic description of water deprotonation equilibrium on TiO 2 (110), a prototypical surface commonly used in mechanistic studies of photocatalytic water splitting. This unique study demonstrates that the molecularly bound water on TiO 2 (110) is preferred over the surface-bound hydroxyls by only 0.035 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wind Energy Instrumentation Development Roadmap

The instrumentation development roadmap provides a guide on which measurements, and instruments, are important for future field campaigns to meet both the science objects and validation plans for their successful execution. The roadmap ensures the measurements are of sufficient type and resolution to meet science objectives and validation needs essential to the campaigns. The roadmap includes measurement categories ranging from instruments that need to be created to existing instruments essential to the field campaigns. The creation of the instrumentation development roadmap builds upon the previous Atmospheric to Electrons (A2e) validation work and formation of the American WAKE experimeNt (AWAKEN) science objectives.

17 WIND ENERGY↗

In Situ Airborne Instrumentation: Addressing and Solving Measurement Problems in Ice Clouds

A meeting of 31 international experts on in situ measurements from aircraft was held to identify unresolved questions concerning ice formation and evolution in ice clouds, assess the current state of instrumentation that can address these problems, introduce emerging technology that may overcome current measurement issues and recommend future courses of action that can improve our understanding of ice cloud microphysical processes and their impact on the environment. The meeting proceedings and outcome has been described in detail in a manuscript submitted to the Bulletin of the American Meteorological Society (BAMS) on March 24, 2011. This paper is currently under review. The remainder of this summary, in the following pages, is the text of the BAMS article. A technical note that will be published by the National Center for Atmospheric Research is currently underway and is expected to be published before the end of the year.

54 ENVIRONMENTAL SCIENCES↗

Comparison of various clocks at LANL LAPP facility

Several 40+ hour data records obtained in Oct 2010 from the Los Alamos Portable Pulser Facility (LAPP) Operational clocks show variations of {approx} 27 nsec. Several 16+ hour data records obtained in Aug 2010 from non-operational clocks like those used operationally from 2005 to the present show variations of {approx} 35 nsec. SLRE variability is xxx +/- yyy sec (std dev). SLRE occasionally show unusual events such as those discussed by Pongratz. We will continue to study and monitor.

47 OTHER INSTRUMENTATION↗

Study Regarding Electromagnetic Radiation Exposure Generated By Mobile Phone

Number of mobile phone users reached to 5 billion subscribers in 2010 [ABI Research, 2010]. A large number of studies illustrated the public concern about adverse effects of mobile phone radiation and possible health hazards. Position of mobile phone use in close proximity to the head leads the main radiation between the hand and the head. Many investigations studying the possible effects of mobile phone exposure, founded no measurable effects of short-term mobile phone radiation, and there was no evidence for the ability to perceive mobile phone EMF in the general population. In this study, field radiation measurements were performed on different brand and different models of mobile phones in active mode, using an EMF RF Radiation Field Strength Power Meter 1 MHz-8 GHz. The study was effectuated on both the 2G and 3G generations phones connected to the providers operating in the frequency range 450 MHz-1800 MHz. There were recorded values in outgoing call and SMS mode, incoming call and SMS mode. Results were compared with ICNIRP guidelines for exposure to general public.

61 RADIATION PROTECTION AND DOSIMETRY↗