New Directions for Chemical Engineering

Over the past century, the work of chemical engineers has helped transform societies and the lives of individuals, from the synthetic fertilizers that helped feed the world to the development of novel materials used in fuels, electronics, medical devices, and other products. Chemical engineers' ability to apply systems-level thinking from molecular to manufacturing scales uniquely positions them to address today’s most pressing problems, including climate change and the overuse of resources by a growing population. New Directions for Chemical Engineering details a vision to guide chemical engineering research, innovation, and education over the next few decades. This report calls for new investments in U.S. chemical engineering and the interdisciplinary, cross-sector collaborations necessary to advance the societal goals of transitioning to a low-carbon energy system, ensuring our production and use of food and water is sustainable, developing medical advances and engineering solutions to health equity, and manufacturing with less waste and pollution. The report also calls for changes in chemical engineering education to ensure the next generation of chemical engineers is more diverse and equipped with the skills necessary to address the challenges ahead.

National Academies of Sciences, Engineering, and M↗

Methods, systems, and devices relating to surgical end effectors

The embodiments disclosed herein relate to various medical device components, including components that can be incorporated into robotic and/or in vivo medical devices, and more specifically including end effectors that can be incorporated into such devices. Certain end effector embodiments include various vessel cautery devices that have rotational movement as well as cautery and cutting functions while maintaining a relatively compact structure. Other end effector embodiments include various end effector devices that have more than one end effector.

42 ENGINEERING↗

Management of Fissionable Equivalent Mass Materials at ORNL - 20146

The US DOE manages an inventory of materials that contains a range of long-lived radioactive isotopes that were produced from the 1960's through the 1980's by irradiating targets in production reactors to produce special heavy isotopes for US DOE programmatic use, scientific research, and industrial and medical applications. Since the production reactors and enrichment facilities that produced many of these materials have been shut down, they are considered unique materials that are not likely to be produced again. ORNL uses these materials in US DoE's center for production, storage, and distribution of TRU isotopes (plutonium through californium) and other related nuclear research programs. ORNL also operates the High Flux Isotope Reactor, which provides a high neutron source for production of isotopes for medical, industrial, and nuclear research programs. As a result, ORNL has an inventory of radioisotopes that are being managed for ongoing research programs and being held for reuse because they have potential intrinsic value to US DOE. An initiative is underway at ORNL to better manage these materials, particularly focusing on those with high fissionable equivalent mass that could impact the ability to perform ongoing or new research projects. This paper describes the actions ORNL is taking to manage these inventories, many of which consist of TRU materials, through reuse and disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods for ultraviolet excitation microscopy of biological surfaces

Microscopy with Ultraviolet Surface Excitation (MUSE) for use in the classroom to enhance life sciences education and curricula, or for other applications, including without limtiation the operating room, other medical environments, research environments, and low resource environments. MUSE's suitability is based on multiple key factors including its simplicity of use, the incorporation of inexpensive hardware including LED illumination, and very basic tissue preparation. The ultraviolet excitation acts as passive optical sectioning confining the generated fluorescence signal to only a few micrometers below the tissue surface thus eliminating the out of focus signals. This facilitates image capture of tissue microstructure and organization from specimens at the intact or sliced surface arising from varying fluorophore concentration within the different cellular compartments. Although just the tissue auto fluorescence maybe used, image quality is enhanced with brief application of nontoxic fluorescent dyes to selectively highlight cellular compartments. Sample preparation is safe, efficient and familiar to students with basic chemistry or biology lab experience. Mixed-dye powders may be used to simplify translation of this method for educational, medical, research, low resource, and other settings.

Demos, Stavros G.↗

Machine learning based reconstruction of intracardiac electrical behavior based on electrocardiograms

A computer-based system and process are disclosed for reconstructing the internal electrical behavior of a patient's heart based partly or wholly on the patient's electrocardiogram (ECG). The output of the process may include, for example, a cardiac activation map, and/or a representation of transmembrane potentials over time. The process advantageously does not require any medical imaging of the patient, and does not require any special medical equipment. For example, the patient's activation map and transmembrane potentials may be reconstructed based solely on a preexisting or newly-obtained 12-lead cardiac ECG of the patient. The process makes use of a machine learning model, such as a neural network based model, trained with actual and/or simulated ECGs and intracardiac electrical data (typically transmembrane potentials) of many thousands of patients. Because an insufficient quantity of such data exists for actual patients, model training may be performed using ECGs and intracardiac electrical data obtained through computer simulations.

Blake, Robert↗

Secure Route: Roadway Risk Mapping for Transportation Planners

The secure transport of sensitive materials across U.S. road networks pose unique challenges for local, state, and federal agencies. Threats range from random events (e.g., accidents, medical emergencies, mechanical failures) to opportunistic or organized tactical assaults. Although the probability of such attacks is very low, the consequences of material loss to foreign states or terrorists can be catastrophic, qualifying these scenarios as “grey swan” events—low-probability, high-impact occurrences that are predictable but difficult to quantify. Traditional risk assessments struggle in these contexts, necessitating a shift toward subjective risk perception to inform planning. Risk perception in transport planning is shaped by various factors, including knowledge of adversarial capabilities, vehicle defenses, manifest details, and geographic features along the route. Geographic features such as bridges, tunnels, roadside elevation, and gaps in cellular coverage introduce vulnerabilities, while mitigative features include safe havens, police stations, and medical services. Temporal variables such as congestion, accidents, and weather further complicate route planning. Despite their importance, existing routing tools like Google Maps and commercial software do not explicitly account for geographic risk features, requiring planners to rely on personal familiarity with routes—a time-intensive, non-scalable approach. This work addresses these gaps by: (1) developing datasets that catalog geographic risk features along U.S. roadways, (2) eliciting risk perceptions from experienced transportation security experts, and (3) linking these perceptions to roadway conditions and geographic data. We implement these capabilities within Secure Route a novel mapping tool for classifying route segment risks associated with roadway conditions. This system provides transportation planners with an intuitive interface to assess and contextualize risk along potential routes, improving decision-making for secure transport. We present current progress in this effort and identify next steps.

Stewart, Robert [ORNL] (ORCID:0000000281867559)↗

Investigating the role of adipose tissue in mobility and aging: design and methods of the Adipose Tissue ancillary to the Study of Muscle, Mobility, and Aging (SOMMA-AT)

Background Age-related changes in adipose tissue affect chronic medical diseases and mobility disability but mechanism remains poorly understood. The goal of this study is to define methods for phenotyping unique characteristics of adipose tissue from older adults. Methods Older adults enrolled in study of muscle, mobility, and aging selected for the adipose tissue ancillary (SOMMA-AT; N = 210, 52.38% women, 76.12 ± 4.37 years) were assessed for regional adiposity by whole-body magnetic resonance (AMRA) and underwent a needle-aspiration biopsy of abdominal subcutaneous adipose tissue (ASAT). ASAT biopsies were flash frozen, fixed, or processed for downstream applications and deposited at the biorepository. Biopsy yields, qualitative features, adipocyte sizes, and concentration of adipokines secreted in ASAT explant conditioned media were measured. Inter-measure Spearman correlations were determined. Results Regional, but not total, adiposity differed by sex: women had greater ASAT mass (8.20 ± 2.73 kg, p < .001) and biopsy yield (3.44 ± 1.81 g, p < .001) than men (ASAT = 5.95 ± 2.30 kg, biopsy = 2.30 ± 1.40 g). ASAT mass correlated with leptin (r = 0.54, p < .001) and not resistin (p = .248) and adiponectin (p = .353). Adipocyte area correlated with ASAT mass (r = 0.34, p < .001), BMI (r = 0.33, p < .001), adiponectin (r = −0.22, p = .005) and leptin (r = 0.18, p = .024) but not with resistin (p = .490). Conclusion In addition to the detailed ASAT biopsy processing in this report, we found that adipocyte area correlated with ASAT mass, and both measures related to some key adipokines in the explant conditioned media. In conclusion, these results, methods, and biological repositories underscore the potential of this unique cohort to impact the understanding of aging adipose biology on disease, disability, and other aging tissues.

60 APPLIED LIFE SCIENCES↗

Consistent performance of large language models in rare disease diagnosis across ten languages and 4917 cases

Background Large language models (LLMs) are increasingly used medicine for diverse applications including differential diagnostic support. The training data used to create LLMs such as the Generative Pretrained Transformer (GPT) predominantly consist of English-language texts, but LLMs could be used across the globe to support diagnostics if language barriers could be overcome. Initial pilot studies on the utility of LLMs for differential diagnosis in languages other than English have shown promise, but a large-scale assessment on the relative performance of these models in a variety of European and non-European languages on a comprehensive corpus of challenging rare-disease cases is lacking. Methods We created 4917 clinical vignettes using structured data captured with Human Phenotype Ontology (HPO) terms with the Global Alliance for Genomics and Health (GA4GH) Phenopacket Schema. These clinical vignettes span a total of 360 distinct genetic diseases with 2525 associated phenotypic features. We used translations of the Human Phenotype Ontology together with language-specific templates to generate prompts in English, Chinese, Czech, Dutch, French, German, Italian, Japanese, Spanish, and Turkish. We applied GPT-4o, version gpt-4o-2024-08-06, and the medically fine-tuned Meditron3-70B to the task of delivering a ranked differential diagnosis using a zero-shot prompt. An ontology-based approach with the Mondo disease ontology was used to map synonyms and to map disease subtypes to clinical diagnoses in order to automate evaluation of LLM responses. Findings For English, GPT-4o placed the correct diagnosis at the first rank 19.9% and within the top-3 ranks 27.0% of the time. In comparison, for the nine non-English languages tested here the correct diagnosis was placed at rank 1 between 16.9% and 20.6%, within top-3 between 25.4% and 28.6% of cases. The Meditron3 model placed the correct diagnosis within the first 3 ranks for 20.9% of cases in English and between 19.9% and 24.0% for the other nine languages. Interpretation The differential diagnostic performance of LLMs across a comprehensive corpus of rare-disease cases was largely consistent across the ten languages tested. This suggests that the utility of LLMs in clinical settings may extend to non-English clinical settings.

Artificial intelligence↗

Persistent urinary metabolic signatures in children with type 1 diabetes

There are an estimated 3.7 million people with undiagnosed type 1 diabetes (T1D), living primarily in poor areas of the globe. Therefore, there is a need for non-invasive, affordable tests to provide accurate diagnosis despite the time post-disease onset and fasting state. Here, we studied persistent urinary T1D biomarkers that can be used to develop such tests. Here, we analyzed the urine metabolomes of three independent cohorts of samples collected within 48 h (from Indiana University), and 1 year (from University of Colorado) and 1–10 years (6 years in average) (from Children’s National Medical Center) post-diagnosis. Samples were submitted to gas chromatography-mass spectrometry and machine learning an0alyses to determine diagnostic metabolite panels. The data were also mapped into a metabolic pathway to understand persistently regulated processes in T1D. Seven metabolites showed consistent increases in all three cohorts: d-glucose, d-mannose, myo-inositol, 3-hydroxyisobutyric acid, gluconolactone, d-gluconic acid, and d-glucuronic acid. A combination of machine learning analysis and metabolite ratios as biomarker candidates diagnosed T1D with high sensitivity and specificity across different cohorts and times. Mapping the regulated metabolites into a pathway showed impairment in glycolysis and overflow of glucose towards other pathways in subjects with T1D that was persistent over time. We identified and cross-validated highly specific and sensitive urinary biomarkers. This opens opportunities to develop affordable, robust, and non-invasive tests. The results also show that most of the biomarkers were signatures of dysregulated glucose metabolism.

Type 1 diabetes↗

Scale-up Unlearnable Examples Learning with High-performance Computing

Recent advancements in AI models, like ChatGPT, are structured to retain user interactions, which could inadvertently include sensitive healthcare data. In the healthcare field, particularly when radiologists use AI-driven diagnostic tools hosted on online platforms, there is a risk that medical imaging data may be repurposed for future AI training without explicit consent, spotlighting critical privacy and intellectual property concerns around healthcare data usage. Addressing these privacy challenges, a novel approach known as Unlearnable Examples (UEs) has been introduced, aiming to make data unlearnable to deep learning models. A prominent method within this area, called Unlearnable Clustering (UC), has shown improved UE performance with larger batch sizes but was previously limited by computational resources (e.g., a single workstation). To push the boundaries of UE performance with theoretically unlimited resources, we scaled up UC learning across various datasets using Distributed Data Parallel (DDP) training on the Summit supercomputer. Our goal was to examine UE efficacy at high-performance computing (HPC) levels to prevent unauthorized learning and enhance data security, particularly exploring the impact of batch size on UE’s unlearnability. Utilizing the robust computational capabilities of the Summit, extensive experiments were conducted on diverse datasets such as Pets, MedMNist, Flowers, and Flowers102. Our findings reveal that both overly large and overly small batch sizes can lead to performance instability and affect accuracy. However, the relationship between batch size and unlearnability varied across datasets, highlighting the necessity for tailored batch size strategies to achieve optimal data protection. The use of Summit’s high-performance GPUs, along with the efficiency of the DDP framework, facilitated rapid updates of model parameters and consistent training across nodes. Our results underscore the critical role of selecting appropriate batch sizes based on the specific characteristics of each dataset to prevent learning and ensure data security in deep learning applications. The source code is publicly available at https: // github. com/ hrlblab/ UE_ HPC .

Zhu, Yanfan [Vanderbilt University, Nashville, TN,↗

Evaluation of Deep Learning Model Architectures for Point-of-Care Ultrasound Diagnostics

Point-of-care ultrasound imaging is a critical tool for patient triage during trauma for diagnosing injuries and prioritizing limited medical evacuation resources. Specifically, an eFAST exam evaluates if there are free fluids in the chest or abdomen but this is only possible if ultrasound scans can be accurately interpreted, a challenge in the pre-hospital setting. In this effort, we evaluated the use of artificial intelligent eFAST image interpretation models. Widely used deep learning model architectures were evaluated as well as Bayesian models optimized for six different diagnostic models: pneumothorax (i) B- or (ii) M-mode, hemothorax (iii) B- or (iv) M-mode, (v) pelvic or bladder abdominal hemorrhage and (vi) right upper quadrant abdominal hemorrhage. Models were trained using images captured in 27 swine. Using a leave-one-subject-out training approach, the MobileNetV2 and DarkNet53 models surpassed 85% accuracy for each M-mode scan site. The different B-mode models performed worse with accuracies between 68% and 74% except for the pelvic hemorrhage model, which only reached 62% accuracy for all model architectures. These results highlight which eFAST scan sites can be easily automated with image interpretation models, while other scan sites, such as the bladder hemorrhage model, will require more robust model development or data augmentation to improve performance. With these additional improvements, the skill threshold for ultrasound-based triage can be reduced, thus expanding its utility in the pre-hospital setting.

47 OTHER INSTRUMENTATION↗

AAPM Truth‐based CT (TrueCT) reconstruction grand challenge

Background: This Special Report summarizes the 2022, AAPM grand challenge on Truth-based CT image reconstruction. Purpose: To provide an objective framework for evaluating CT reconstruction methods using virtual imaging resources consisting of a library of simulated CT projection images of a population of human models with various diseases. Methods: Two hundred unique anthropomorphic, computational models were created with varied diseases consisting of 67 emphysema, 67 lung lesions, and 66 liver lesions. The organs were modeled based on clinical CT images of real patients. The emphysematous regions were modeled using segmentations from patient CT cases in the COPDGene Phase I dataset. For the lung and liver lesion cases, 1–6 malignant lesions were created and inserted into the human models, with lesion diameters ranging from 5.6 to 21.9 mm for lung lesions and 3.9 to 14.9 mm for liver lesions. The contrast defined between the liver lesions and liver parenchyma was 82 ± 12 HU, ranging from 50 to 110 HU. Similarly, the contrast between the lung lesions and the lung parenchyma was defined as 781 ± 11 HU, ranging from 725 to 805 HU. For the emphysematous regions, the defined HU values were −950 ± 17 HU ranging from −918 to −979 HU. The developed human models were imaged with a validated CT simulator. The resulting CT sinograms were shared with the participants. The participants reconstructed CT images from the sinograms and sent back their reconstructed images. Further, the reconstructed images were then scored by comparing the results against the corresponding ground truth values. The scores included both task-generic (root mean square error [RMSE] and structural similarity matrix [SSIM]), and task-specific (detectability index [d’] and lesion volume accuracy) metrics. For the cases with multiple lesions, the measured metric was averaged across all the lesions. To combine the metrics with each other, each metric was normalized to a range of 0 to 1 per disease type, with “0” and “1” being the worst and best measured values across all cases of the disease type for all received reconstructions. Results: The True-CT challenge attracted 52 participants, out of which 5 successfully completed the challenge and submitted the requested 200 reconstructions. Across all participants and disease types, SSIM absolute values ranged from 0.22 to 0.90, RMSE from 77.6 to 490.5 HU, d’ from 0.1 to 64.6, and volume accuracy ranged from 1.2 to 753.1 mm3. The overall scores demonstrated that participant “A” had the best performance in all categories, except for the metrics of d’ for lung lesions and RMSE for liver lesions. Participant “A” had an average normalized score of 0.41 ± 0.22, 0.48 ± 0.32, and 0.42 ± 0.33 for the emphysema, lung lesion, and liver lesion cases, respectively. Conclusions: The True-CT challenge successfully enabled objective assessment of CT reconstructions with the unique advantage of access to a diverse population of diseased human models with known ground truth. This study highlights the significant potential of virtual imaging trials in objective assessment of medical imaging technologies.

60 APPLIED LIFE SCIENCES↗

Domain Shift Analysis in Chest Radiographs Classification in a Veterans Healthcare Administration Population

This study aims to assess the impact of domain shift on chest X-ray classification accuracy and to analyze the influence of ground truth label quality and demographic factors such as age group, sex, and study year. We used a DenseNet121 model pre-trained MIMIC-CXR dataset for deep learning-based multi-label classification using ground truth labels from radiology reports extracted using the CheXpert and CheXbert Labeler. We compared the performance of the 14 chest X-ray labels on the MIMIC-CXR and Veterans Healthcare Administration chest X-ray dataset (VA-CXR). The validation of ground truth and the assessment of multi-label classification performance across various NLP extraction tools revealed that the VA-CXR dataset exhibited lower disagreement rates than the MIMIC-CXR datasets. Additionally, there were notable differences in AUC scores between models utilizing CheXpert and CheXbert. When evaluating multi-label classification performance across different datasets, minimal domain shift was observed in the unseen VA dataset, except for the label “Enlarged Cardiomediastinum.” The subgroup with the most significant variations in multi-label classification performance was study year. These findings underscore the importance of considering domain shift in chest X-ray classification tasks, paying particular attention to the temporality of the exam. Our study reveals the significant impact of domain shift and demographic factors on chest X-ray classification, emphasizing the need for improved transfer learning and robust model development. Addressing these challenges is crucial for advancing medical imaging research and improving patient care.

chest X-ray image classification↗

Measurement of 227 Ac impurity in 225 Ac using decay energy spectroscopy

225 Ac is a valuable medical radionuclide for targeted $\alpha$ therapy, but 227 Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227 Ac, with the 227 Ac/ 225 Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small changes in temperature. By embedding 225 Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and 100% detection efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from $\alpha$ decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss in this paper. Using this technique we measured the EOB 227 Ac impurity to be (0.142 ± 0.005)% for a single production sample. This demonstration has shown that DES is a useful tool for quantitative measurements of complicated spectra.

07 ISOTOPE AND RADIATION SOURCES↗

Enabling end-to-end secure federated learning in biomedical research on heterogeneous computing environments with APPFLx

Facilitating large-scale, cross-institutional collaboration in biomedical machine learning (ML) projects requires a trustworthy and resilient federated learning (FL) environment to ensure that sensitive information such as protected health information is kept confidential. Specifically designed for this purpose, this work introduces APPFLx - a low-code, easy-to-use FL framework that enables easy setup, configuration, and running of FL experiments. APPFLx removes administrative boundaries of research organizations and healthcare systems while providing secure end-to-end communication, privacy-preserving functionality, and identity management. Furthermore, it is completely agnostic to the underlying computational infrastructure of participating clients, allowing an instantaneous deployment of this framework into existing computing infrastructures. Experimentally, the utility of APPFLx is demonstrated in two case studies: (1) predicting participant age from electrocardiogram (ECG) waveforms, and (2) detecting COVID-19 disease from chest radiographs. Here, ML models were securely trained across heterogeneous computing resources, including a combination of on-premise high-performance computing and cloud computing facilities. By securely unlocking data from multiple sources for training without directly sharing it, these FL models enhance generalizability and performance compared to centralized training models while ensuring data remains protected. In conclusion, APPFLx demonstrated itself as an easy-to-use framework for accelerating biomedical studies across organizations and healthcare systems on large datasets while maintaining the protection of private medical data.

Biomedical Research↗

Predicting nutrition and environmental factors associated with female reproductive disorders using a knowledge graph and random forests

Female reproductive disorders (FRDs) are common health conditions that may present with significant symptoms. Diet and environment are potential areas for FRD interventions. We utilized a knowledge graph (KG) method to predict factors associated with common FRDs (for example, endometriosis, ovarian cyst, and uterine fibroids). We harmonized survey data from the Personalized Environment and Genes Study (PEGS) on internal and external environmental exposures and health conditions with biomedical ontology content. We merged the harmonized data and ontologies with supplemental nutrient and agricultural chemical data to create a KG. We analyzed the KG by embedding edges and applying a random forest for edge prediction to identify variables potentially associated with FRDs. We also conducted logistic regression analysis for comparison. Across 9765 PEGS respondents, the KG analysis resulted in 8535 significant or suggestive predicted links between FRDs and chemicals, phenotypes, and diseases. Amongst these links, 32 were exact matches when compared with the logistic regression results, including comorbidities, medications, foods, and occupational exposures. Mechanistic underpinnings of predicted links documented in the literature may support some of our findings. Our KG methods are useful for predicting possible associations in large, survey-based datasets with added information on directionality and magnitude of effect from logistic regression. These results should not be construed as causal but can support hypothesis generation. This investigation enabled the generation of hypotheses on a variety of potential links between FRDs and exposures. Future investigations should prospectively evaluate the variables hypothesized to impact FRDs.

60 APPLIED LIFE SCIENCES↗

Trends in Financial Relationships Between Industry and Radiation Oncologists Versus Other Physicians in the United States from 2014 to 2018

The Open Payments transparency program publishes data on industry-physician payments, in part to discourage relationships considered inappropriate including gifts, meals, and speaker’s bureau fees. We evaluated trends in physician-level payments to test whether implementation of Open Payments resulted in fewer industry–radiation oncologist (RO) interactions or shifted interactions toward those considered more appropriate compared with medical oncologists (MOs) and other hospital-based physicians (HBPs).

62 RADIOLOGY AND NUCLEAR MEDICINE↗