Search NASA⌕ Search

SEARCH · Search NASA

Results for “Minimum variance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

An estimate of equatorial wave energy flux at 9- to 90-day periods in the Central Pacific

Deep fluctuations in current along the equator in the Central Pacific are dominated by coherent structures which correspond closely to narrow-band propagating equatorial waves. Currents were measured roughly at 1500 and 3000 m depths at five moorings between 144 and 148 deg W from January 1981 to March 1983, as part of the Pacific Equatorial Ocean Dynamics program. In each frequency band resolved, a single complex empirical orthogonal function accounts for half to three quarters of the observed variance in either zonal or meridional current. Dispersion for equatorial first meridional Rossby and Rossby gravity waves is consistent with the observed vertical-zonal coherence structure. The observations indicate that energy flux is westward and downward in long first meridional mode Rossby waves at periods 45 days and longer, and eastward and downward in short first meridional mode Rossby waves and Rossby-gravity waves at periods 30 days and shorter. A local minimum in energy flux occurs at periods corresponding to a maximum in upper-ocean meridional current energy contributed by tropical instability waves. Total vertical flux across the 9- to 90-day period range is 2.5 kW/m.

Eriksen, Charles C.↗

Multi-scale fusion algorithm of intensity and polarization-difference images based on edge information enhancement

To better integrate complementary and redundant information from different source images, improve the edge information, and facilitate the target detection. A multi-scale fusion algorithm of intensity and polarization-difference (PD) images based on edge information enhancement is proposed. Firstly, intensity images are obtained by the polarization information analysis method. PD images are obtained by the adaptive polarization-difference imaging approach based on the principle of minimum mutual information. Secondly, guided filter, affine transformations and Block-Matching and 3D filtering are embedded in visibility enhancement to improve the intensity and PD images. Thirdly, the two images are decomposed into high-frequency and low-frequency images by the dual-tree complex wavelet transform (DT-CWT). The high-frequency and low-frequency images are fused by the fusion rules based on edge detection and the regional variance matching degree respectively. Finally, the fusion image is obtained by the inverse DT-CWT. Experimental results demonstrate that fusion images of the proposed algorithm are significantly improved in information entropy, average gradient, and spatial frequency. Compared with the existing methods, it can achieve a better edge enhancement for images in a turbid medium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trap-assisted Auger-Meitner recombination in GaN p-i-n diodes

Most properties of semiconductor devices are dominated by shallow impurities. However, deep defects often play an important role, for instance, in recombination processes or high field transport. While a variety of techniques are available to assess the density and energy levels of impurities, other properties, such as the recombination mechanisms of the defects, escape observation. We report on the direct measurement of hot electrons generated by trap-assisted Auger-Meitner recombination (TAAR) in GaN p-i-n diodes. By performing electron emission spectroscopy (EES) on diodes with surfaces activated to negative electron affinity by cesium, we observe the expected overflow electrons of p-i-n diodes under low current injection. However, when operating the devices at higher current densities, as low as ∼25 A/c⁢m 2 , we measure the emission of high-energy electrons. At variance with the observed hot electrons in light-emitting diodes (LEDs) using EES, the hot electrons generated in p-i-n diodes at our tested currents cannot be from eeh Auger-Meitner recombination due to the diodes' significantly lower carrier densities compared to those in LEDs. During our measurements, we observe the emission of accumulated electrons with energies ∼0.42 eV, ∼0.99 eV, ∼1.43 eV, and ∼2.32 eV above the conduction-band minimum (CBM) at various bias conditions, suggesting the existence of conduction-band features in GaN at these energies where electrons can be long-lived, such as satellite-valley minima and inflection points. We also measure incompletely relaxed hot electrons approaching energies 1.97 ± 0.13 eV and 2.94 ± 0.13 eV above the CBM, as the diodes are biased to high currents, suggesting at least some of the TAAR partaking defects have an energy level ≳1.97 eV and ≳2.94 eV away from either the conduction or valence band edges. Additionally, at our highest operating currents, we measure hot electrons with energies 3.28 ± 0.13 eV above the CBM, providing direct evidence of TAAR processes involving shallow impurities. This unexpected observation of TAAR in GaN p-i-n diodes spotlights the importance of further studies of defects in GaN and the necessity to incorporate the multi-phonon emission, radiative, and TAAR capture steps of defect-assisted recombination cycles into device modeling. Furthermore, this experiment demonstrates the applicability of the simplest semiconductor structures, p-i-n diodes, as a test bed to study the rich recombination physics of semiconductor materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial Statistical Data Fusion (SSDF)

As remote sensing for scientific purposes has transitioned from an experimental technology to an operational one, the selection of instruments has become more coordinated, so that the scientific community can exploit complementary measurements. However, tech nological and scientific heterogeneity across devices means that the statistical characteristics of the data they collect are different. The challenge addressed here is how to combine heterogeneous remote sensing data sets in a way that yields optimal statistical estimates of the underlying geophysical field, and provides rigorous uncertainty measures for those estimates. Different remote sensing data sets may have different spatial resolutions, different measurement error biases and variances, and other disparate characteristics. A state-of-the-art spatial statistical model was used to relate the true, but not directly observed, geophysical field to noisy, spatial aggregates observed by remote sensing instruments. The spatial covariances of the true field and the covariances of the true field with the observations were modeled. The observations are spatial averages of the true field values, over pixels, with different measurement noise superimposed. A kriging framework is used to infer optimal (minimum mean squared error and unbiased) estimates of the true field at point locations from pixel-level, noisy observations. A key feature of the spatial statistical model is the spatial mixed effects model that underlies it. The approach models the spatial covariance function of the underlying field using linear combinations of basis functions of fixed size. Approaches based on kriging require the inversion of very large spatial covariance matrices, and this is usually done by making simplifying assumptions about spatial covariance structure that simply do not hold for geophysical variables. In contrast, this method does not require these assumptions, and is also computationally much faster. This method is fundamentally different than other approaches to data fusion for remote sensing data because it is inferential rather than merely descriptive. All approaches combine data in a way that minimizes some specified loss function. Most of these are more or less ad hoc criteria based on what looks good to the eye, or some criteria that relate only to the data at hand.

Braverman, Amy J.↗

Exploring cosmic origins with CORE: Gravitational lensing of the CMB

Lensing of the cosmic microwave background (CMB) is now a well-developed probe of the clustering of the large-scale mass distribution over a broad range of redshifts. By exploiting the non-Gaussian imprints of lensing in the polarization of the CMB, the CORE mission will allow production of a clean map of the lensing deflections over nearly the full-sky. The number of high-S/N modes in this map will exceed current CMB lensing maps by a factor of 40, and the measurement will be sample-variance limited on all scales where linear theory is valid. Here, we summarise this mission product and discuss the science that will follow from its power spectrum and the cross-correlation with other clustering data. For example, the summed mass of neutrinos will be determined to an accuracy of 17 meV combining CORE lensing and CMB two-point information with contemporaneous measurements of the baryon acoustic oscillation feature in the clustering of galaxies, three times smaller than the minimum total mass allowed by neutrino oscillation measurements. Lensing has applications across many other science goals of CORE, including the search for B-mode polarization from primordial gravitational waves. Here, lens-induced B-modes will dominate over instrument noise, limiting constraints on the power spectrum amplitude of primordial gravitational waves. With lensing reconstructed by CORE, one can "delens" the observed polarization internally, reducing the lensing B-mode power by 60 %. This can be improved to 70 % by combining lensing and measurements of the cosmic infrared background from CORE, leading to an improvement of a factor of 2.5 in the error on the amplitude of primordial gravitational waves compared to no delensing (in the null hypothesis of no primordial B-modes). Lensing measurements from CORE will allow calibration of the halo masses of the tens of thousands of galaxy clusters that it will find, with constraints dominated by the clean polarization-based estimators. The 19 frequency channels proposed for CORE will allow accurate removal of Galactic emission from CMB maps. We present initial findings that show that residual Galactic foreground contamination will not be a significant source of bias for lensing power spectrum measurements with CORE.

79 ASTRONOMY AND ASTROPHYSICS↗

Aircrew coordination and decisionmaking: Peer ratings of video tapes made during a full mission simulation

Six professionally active, retired captains rated the coordination and decisionmaking performances of sixteen aircrews while viewing videotapes of a simulated commercial air transport operation. The scenario featured a required diversion and a probable minimum fuel situation. Seven point Likert-type scales were used in rating variables on the basis of a model of crew coordination and decisionmaking. The variables were based on concepts of, for example, decision difficulty, efficiency, and outcome quality; and leader-subordin ate concepts such as person and task-oriented leader behavior, and competency motivation of subordinate crewmembers. Five-front-end variables of the model were in turn dependent variables for a hierarchical regression procedure. The variance in safety performance was explained 46%, by decision efficiency, command reversal, and decision quality. The variance of decision quality, an alternative substantive dependent variable to safety performance, was explained 60% by decision efficiency and the captain's quality of within-crew communications. The variance of decision efficiency, crew coordination, and command reversal were in turn explained 78%, 80%, and 60% by small numbers of preceding independent variables. A principle component, varimax factor analysis supported the model structure suggested by regression analyses.

Murphy, M. R.↗

Diurnal variation in the turbulent structure of the cloudy marine boundary layer during FIRE 1987

During the 1987 FIRE marine stratocumulus experiment the U.K. Meteorological Office operated a set of turbulence probes attached to the tether cable of a balloon based on San Nicolas Island. Typically six probes were used; each probe is fitted with Gill propeller anemometers, a platinum resistance thermometer and wet and dry thermistors, to permit measurements of the fluxes of momentum, heat, and humidity. The orientation of each probe is determined from a pair of inclinometers and a three-axis magnetometer. Sufficient information is available to allow the measured wind velocities to be corrected for the motion of the balloon. On the 14 to 15 July measurements were made over the period 1530 to 1200 UTC and again, after a short break for battery recharging and topping-up the balloon, between 0400 to 0900 UTC. Data were therefore recorded from morning to early evening, and again for a period overnight. Six probes were available for the daytime measurements, five for the night. Data were recorded at 4 Hz for individual periods of a little over an hour. The intention was to keep a minimum of one probe at or just above cloud top; small changes in balloon height were necessary to accommodate changes in inversion height. The ability of the balloon system to make simultaneous measurements at several levels allows the vertical structure of the boundary layer to be displayed without resort to composites. Turbulent statistics were calculated from 2 hour periods, one straddling local noon and one at night. These were subdivided into half-hour averaging intervals for the evaluation of variances and fluxes.

Hignett, Phillip↗

Fast patient-specific Monte Carlo brachytherapy dose calculations via the correlated sampling variance reduction technique

Purpose: To demonstrate potential of correlated sampling Monte Carlo (CMC) simulation to improve the calculation efficiency for permanent seed brachytherapy (PSB) implants without loss of accuracy. Methods: CMC was implemented within an in-house MC code family (PTRAN) and used to compute 3D dose distributions for two patient cases: a clinical PSB postimplant prostate CT imaging study and a simulated post lumpectomy breast PSB implant planned on a screening dedicated breast cone-beam CT patient exam. CMC tallies the dose difference, {Delta}D, between highly correlated histories in homogeneous and heterogeneous geometries. The heterogeneous geometry histories were derived from photon collisions sampled in a geometrically identical but purely homogeneous medium geometry, by altering their particle weights to correct for bias. The prostate case consisted of 78 Model-6711 {sup 125}I seeds. The breast case consisted of 87 Model-200 {sup 103}Pd seeds embedded around a simulated lumpectomy cavity. Systematic and random errors in CMC were unfolded using low-uncertainty uncorrelated MC (UMC) as the benchmark. CMC efficiency gains, relative to UMC, were computed for all voxels, and the mean was classified in regions that received minimum doses greater than 20%, 50%, and 90% of D{sub 90}, as well as for various anatomical regions. Results: Systematic errors in CMC relative to UMC were less than 0.6% for 99% of the voxels and 0.04% for 100% of the voxels for the prostate and breast cases, respectively. For a 1 x 1 x 1 mm{sup 3} dose grid, efficiency gains were realized in all structures with 38.1- and 59.8-fold average gains within the prostate and breast clinical target volumes (CTVs), respectively. Greater than 99% of the voxels within the prostate and breast CTVs experienced an efficiency gain. Additionally, it was shown that efficiency losses were confined to low dose regions while the largest gains were located where little difference exists between the homogeneous and heterogeneous doses. On an AMD 1090T processor, computing times of 38 and 21 sec were required to achieve an average statistical uncertainty of 2% within the prostate (1 x 1 x 1 mm{sup 3}) and breast (0.67 x 0.67 x 0.8 mm{sup 3}) CTVs, respectively. Conclusions: CMC supports an additional average 38-60 fold improvement in average efficiency relative to conventional uncorrelated MC techniques, although some voxels experience no gain or even efficiency losses. However, for the two investigated case studies, the maximum variance within clinically significant structures was always reduced (on average by a factor of 6) in the therapeutic dose range generally. CMC takes only seconds to produce an accurate, high-resolution, low-uncertainly dose distribution for the low-energy PSB implants investigated in this study.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-BRD-10: Improving Plan Delivery Efficiency of Intensity Modulated Proton Plans with Prioritized Optimization

Purpose: To integrate treatment delivery time into plan optimization in spot scanning intensity modulated proton therapy. Utilizing a dedicated research treatment planning system we present an optimization approach to explore the trade-off between the correlated parameters treatment time and plan quality on an astrocytoma patient case. Methods: The planning system is based on prioritized optimization, a stepwise approach of implementing clinical goals. After each optimization step, dosimetric achievements are turned into hard constraints to maintain the achieved plan quality. Prior achievements can be violated by a so-called slip-factor which allows to study possible trade-offs of conflicting goals. Plan quality is obtained in the first two steps, while the third step optimizes delivery efficiency by working on the spot weight distribution via four alternative Methods: elimination of low weighted spots (1), elimination of spots hardly contributing to PTV dose, followed by reoptimization of the resulting smaller optimization problem (2), reduction of spot weights variance within each energy layer (3), and reduction of the overall spot weight sum (4). Treatment times were calculated assuming either constant or variable beam current depending on the lowest spot weight. Results: Delivery efficiency can be improved remarkably without influencing the plan quality. Absolute time savings depend on the utilized method and facility properties. By varying slip-factor and spot reduction limits, a border of worsening quality is detectable for all methods.Deleting low weighted spots by 10% results in a noticeable decrease in minimum target dose. Further reduction results in more heterogeneous dose distributions and insufficient coverage. Option 2 showed constant plan quality for spot reductions of more than 10%. Conclusion: Including treatment time optimization as a final step into prioritized optimization allows for more efficient treatment plans by redistributing the spot patterns without compromising plan quality, which has to remain the main intent of radiotherapy treatment. The authors report grants from German Research Foundation (DFG) during the conduct of the study.

60 APPLIED LIFE SCIENCES↗

Method and computer product to increase accuracy of time-based software verification for sensor networks

A recursive verification protocol to reduce the time variance due to delays in the network by putting the subject node at most one hop from the verifier node provides for an efficient manner to test wireless sensor nodes. Since the software signatures are time based, recursive testing will give a much cleaner signal for positive verification of the software running on any one node in the sensor network. In this protocol, the main verifier checks its neighbor, who in turn checks its neighbor, and continuing this process until all nodes have been verified. This ensures minimum time delays for the software verification. Should a node fail the test, the software verification downstream is halted until an alternative path (one not including the failed node) is found. Utilizing techniques well known in the art, having a node tested twice, or not at all, can be avoided.

97 MATHEMATICS AND COMPUTING↗

A survey of bidirectional greater than or equal to MeV ion flows during the Helios 1 and Helios 2 mission: Observations from the Goddard Space Flight Center instruments

A survey is made of 1.1-2.1 MeV and 3-21 MeV bidirectional ion flows (BIFs) in the solar wind at 0.3-1.0 AU observed by the Goddard Space Flight Center instruments on the Helios 1 and Helios 2 spacecraft during the spacecraft mission in 1974-1984 and 1979-1980, respectively. Some 774 events have been identified Helios 1, and 223 at Helios 2, with mean durations of approximately 2.5 hr at each spacecraft. BIFs were observed for approximately 1%-3% of the observation time during solar minimum conditions in 1975-1977 and for approximately 10%-14% in 1980-1981 around solar maximum. These occurrence rates are similar to those of approximately 1 MeV BIFs observed at the Interplanetary Monitoring Platform 8 and International Sun Earth Explorers (ISEE) 3 spacecraft, and of bidirectional electron heat fluxes at ISEE 3. Solar wind plasma parameters during BIFs were similar to those found generally during the Helios missions, though BIFs have a greater tendency to be associated with cool, low-beta plasma, moderately enhanced and low-variance magnetic fields, both less than 300 km/s and greater than 750 km/s solar wind. Solar wind features associated with the greater than 4 hr duration BIFs include clear plasma shock-driver signatures: approximately 36% of the events; postshock plasma, not associated with shock-driver signatures: approximately 13%; noncompressive density enhancements: approximately 22% (half associated with plasma proton temperature depression); high-speed streams not associated with shocks: approximately 10%; corotating interaction regions: approximately 5%; immediately upstream of shocks: approximately 5%. Around 8% were associated with other solar wind structures, while approximately 4% showed no associated structure. BIFs were present in several of the shock drivers associated with coronal mass ejections (CMEs) observed by the Solwind coronagraph during intervals when Helios 1 was off the limbs of the Sun, showing directly the association of some BIFs with CMEs. some BIFs with CMEs.

Richardson, I. G.↗

Nonlinear equilibration of localized instabilities on a baroclinic jet

Dynamical mechanisms underlying the equilibration of absolute instability are examined in a nonlinear, quasigeostrophic, two-layer model. The key to understanding the nonlinear equilibration is in recognizing that linear absolute instabilities can be stabilized both by a reduction of the vertical shear and by enhancement of the mean barotropic velocity. In a localized domain, the equilibration process proceeds with the creation of locally convectively unstable regions downstream, which encroach onto the locally absolutely unstable region until the local instability is suppressed. That local instabilities exist only if absolutely unstable regions span a minimum size is verified by eigenvalue calculations of three-dimensional flows. Numerical examples suggest that this critical size is at least 9000 km for a wide range of parameter values chosen to investigate the midlatitude storm tracks. Fluctuations arising from local absolute instability obtain maximum amplitude in the downstream convectively unstable regions rather than in the absolutely unstable regions themselves. Together, these results suggest that if an equilibrated absolute instability were to occur in midlatitudes, a zonal band of surface easterlies exceeding 900 km would be required and the associated enhanced variances would not be found coincident with the regions of absolute instability.

Delsole, Timothy M.↗

Sensitivity of Austempering Heat Treatment of Ductile Irons to Changes in Process Parameters

Austempered ductile iron (ADI) is frequently obtained by means of a three-step austempering heat treatment. The parameters of this process play a crucial role on the microstructure of the final product. This paper considers the influence of some process parameters (i.e., the initial microstructure of ductile iron and the thermal cycle) on key features of the heat treatment (such as minimum required time for austenitization and austempering and microstructure of the final product). A computational simulation of the austempering heat treatment is reported in this work, which accounts for a coupled thermo-metallurgical behavior in terms of the evolution of temperature at the scale of the part being investigated (the macroscale) and the evolution of phases at the scale of microconstituents (the microscale). The paper focuses on the sensitivity of the process by looking at a sensitivity index and scatter plots. The sensitivity indices are determined by using a technique based on the variance of the output. The results of this study indicate that both the initial microstructure and the thermal cycle parameters play a key role in the production of ADI. This work also provides a guideline to help selecting values of the appropriate process parameters to obtain parts with a required microstructural characteristic.

36 MATERIALS SCIENCE↗

Analysis of open-loop conical scan pointing error and variance estimators

General pointing error and variance estimators for an open-loop conical scan (conscan) system are derived and analyzed. The conscan algorithm is modeled as a weighted least-squares estimator whose inputs are samples of receiver carrier power and its associated measurement uncertainty. When the assumptions of constant measurement noise and zero pointing error estimation are applied, the variance equation is then strictly a function of the carrier power to uncertainty ratio and the operator selectable radius and period input to the algorithm. The performance equation is applied to a 34-m mirror-based beam-waveguide conscan system interfaced with the Block V Receiver Subsystem tracking a Ka-band (32-GHz) downlink. It is shown that for a carrier-to-noise power ratio greater than or equal to 30 dB-Hz, the conscan period for Ka-band operation may be chosen well below the current DSN minimum of 32 sec. The analysis presented forms the basis of future conscan work in both research and development as well as for the upcoming DSN antenna controller upgrade for the new DSS-24 34-m beam-waveguide antenna.

Alvarez, L. S.↗

CLASS: The Cosmology Large Angular Scale Surveyor

The Cosmology Large Angular Scale Surveyor (CLASS) is an experiment to measure the signature of a gravitational wave background from inflation in the polarization of the cosmic microwave background (CMB). CLASS is a multi-frequency array of four telescopes operating from a high-altitude site in the Atacama Desert in Chile. CLASS will survey 70% of the sky in four frequency bands centered at 38, 93, 148, and 217 GHz, which are chosen to straddle the Galactic-foreground minimum while avoiding strong atmospheric emission lines. This broad frequency coverage ensures that CLASS can distinguish Galactic emission from the CMB. The sky fraction of the CLASS survey will allow the full shape of the primordial B-mode power spectrum to be characterized, including the signal from reionization at low-length. Its unique combination of large sky coverage, control of systematic errors, and high sensitivity will allow CLASS to measure or place upper limits on the tensor-to-scalar ratio at a level of r = 0:01 and make a cosmic-variance-limited measurement of the optical depth to the surface of last scattering, tau. (c) (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

propagation↗

Variability of Fram Strait Ice Flux and North Atlantic Oscillation

An important term in the mass balance of the Arctic Ocean sea ice is the ice export. We estimated the winter sea ice export through the Fram Strait using ice motion from satellite passive microwave data and ice thickness data from moored upward looking sonars. The average winter area flux over the 18-year record (1978-1996) is 670,000 square km, approximately 7% of the area of the Arctic Ocean. The winter area flux ranges from a minimum of 450,000 sq. km in 1984 to a maximum of 906,000 sq km in 1995. The daily, monthly and interannual variabilities of the ice area flux are high. There is an upward trend in the ice area flux over the 18-year record. The average winter volume flux over the winters of October 1990 through May 1995 is 1745 cubic km ranging from a low of 1375 cubic km in 1990 to a high of 2791 cubic km in 1994. The sea-level pressure gradient across the Fram Strait explains more than 80% of the variance in the ice flux over the 18-year record. We use the coefficients from the regression of the time-series of area flux versus pressure gradient across the Fram Strait and ice thickness data to estimate the summer area and volume flux. The average 12-month area flux and volume flux are 919,000 sq km and 2366 cubic km. We find a significant correlation (R =0.86) between the area flux and positive phases of the North Atlantic Oscillation (NAO) index over the months of December through March. Correlation between our six years of volume flux estimates and the NAO index gives R =0.56. During the high NAO years, a more intense Icelandic low increases the gradient in the sea-level pressure by almost 1 mbar across the Fram Strait thus increasing the atmospheric forcing on ice transport. Correlation is reduced during the negative NAO years because of decreased dominance of this large-scale atmospheric pattern on the sea-level pressure gradient across the Fram Strait. Additional information is contained in the original.

Kwok, Ron↗

Indoor Ground Testing of a Small UAS Sense and Avoid Airborne Doppler Radar

The National Aeronautics and Space Administration’s Unmanned Aircraft System (UAS) Traffic Management (UTM) project is researching prototype technologies needed to ensure safe integration of UAS operations into the National Airspace System (NAS). Within the UTM Concept of Operations, UAS would be equipped with on-board Sense and Avoid (SAA) technology to continually monitor for manned and unmanned aircraft in its vicinity while operating beyond visual line of sight in uncontrolled airspace. To support this effort, a candidate commercially available 24.5 GHz Doppler radar was selected and evaluated to determine if the technology could reliably support minimum requirements for SAA applications of small UAS (sUAS). Indoor ground tests were conducted inside the NASA Langley Research Center’s Experimental Test Range (ETR) from a stationary platform to evaluate the Doppler radar performance characteristics and gain operational proficiency before the radar was authorized to transmit outdoors. A high speed linear rail system was developed for the radar evaluation and was shown to be an effective method to generate Doppler radar targets of known radar cross section. The accuracy of the range and velocity reported by the radar was shown to be dependent on the Kalman filter state variance parameter settings. Antenna measurements were collected with the radar installed both on and off a sUAS to quantify the relative antenna gain, beam width and side lobe levels of the radar’s Metamaterial Electronically Scanning Array (MESA) antennas at boresight and extreme field of view pointing vectors. The relative antenna gain measured 2.6 dB lower at extreme field view angles compared to the boresight radiation pattern.

Szatkowski, George N.↗

SU-F-T-19: The Consistency Dosimetric Analysis of the Accelerated Breast Brachytherapy

Purpose: To assess the best approach in accept a treatment plan for APBI Savi patients. Should we run a treatment verification test prior to delivering it to the patient? Should we check each CT scan in regards to the initial one in dosimetrical terms? Do we need deformable registration and adaptive planning for each fraction? These are the questions we want to answer running a dosimetric analysis of the dose variances for APBI treatments who receive 10 fractions and no re-planning has been done being considered unnecessary with today’s means of assessment. Methods: A retrospective analysis of 30 patients treated with SAVI applicators were considered for this study. The CT scans taken before each treatment were imported in the treatment planning system and registered with the initial CT scan. The images were fused together with respective to the applicator, using landmark registration. Dosimetric evaluations were performed. Dose received by skin, ribs and PTV on CT images with respect to the initial treatment plan were recorded including maximum, average and minimum dose Results: All the structures displayed changes in volume over the 10 fractions of treatment. The cavities reduction in volume was considerable with a maximum reduction of over 10%. The PTV-eval is covered better due to this fact while the critical organs manifest an increase in the total and maximum dose delivered. Ribs and skin surface that are required by B39 protocol to be monitored can acquire maximum doses of 20% to 30% respectively. Conclusion: A dosimetric evaluation prior to the initial treatment and prior to each of the 10 fractions is proven to be necessary. Deformable registration and adaptive planning have to be studied more and eventually implemented for every patient who received more than one fraction of any type of brachytherapy treatment. Immobilization ad localization methods must be improved and studied further.

60 APPLIED LIFE SCIENCES↗