Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Investigation of a {sup 90}Sr/{sup 90}Y source for intra-ocular treatment of wet age-related macular degeneration

Purpose: The purpose of this study is to perform an extensive investigation of an approximately 2.5 mm long {sup 90}Sr/{sup 90}Y source designed for treating wet age-related macular degeneration. Methods: As part of this investigation, a NIST-traceable absorbed dose to water calibration technique was established, and a source deployment verification test was developed. The influence of treatment cannula construction tolerance on the measurements as well as the dose delivered to the patient was investigated using the Monte Carlo code MCNP5. Variation between production cannulae was quantified experimentally using a well-type ionization chamber, and additional measurements along with Monte Carlo calculations of the collimating insert used for source deployment verification were performed to validate the model. Results: Maximum variation in the integrated target dose was seen when the source was shifted laterally within the treatment cannula. For the well chamber measurements, the observed standard deviation in ionization current for a single source placed in different reference cannulae was {+-}0.3%, with a maximum observed range of less than {+-}0.5%. Clinical cannulae in the collimating insert showed an average of 17.8%{+-}0.4% of the reference signal when sources were fully deployed compared to 18.5% predicted by Monte Carlo calculations. This discrepancy has been attributed primarily to construction of the collimator since the collimation gap was observed to be approximately 0.025-0.075 mm smaller than specified. Construction tolerance of the well chamber insert as well as position tolerance of the cannula tip were both investigated, and their influence on the predicted signal was quantified. Additional measurements along with Monte Carlo based calculations of the collimating insert with polyethylene spacers added to the setup were performed to validate the Monte Carlo model. The shimmed Monte Carlo and measured data agree to within 1%, which is a magnitude difference of approximately 0.1% of the reference signal. Conclusions: This investigation confirms that the signal for an acceptably deployed source in the collimating insert is between 17.5% and 21.5% of the reference signal, as calculated using Monte Carlo models. Clinical cannulae for which the source deployment verification measurement falls outside the acceptable range should not be used to treat patients.

07 ISOTOPE AND RADIATION SOURCES↗

VERA BWR progression problems

During the first phase of the Consortium for Advanced Simulation of Light Water Reactors (CASL) program, the Virtual Environment for Reactor Applications (VERA) was developed with a focus on capabilities for high-fidelity, multiphysics simulation of pressurized water reactors (PWRs). During this development effort, a set of progression problems was created ranging from smaller pin cell calculations to larger 3D full-core calculations. These progression problems helped to guide the development of the software and served as benchmarks against which to test VERA. Since 2019, efforts have been made to extend the capabilities of VERA to model boiling water reactors (BWRs). Because BWR simulations come with many unique challenges, a set of BWR progression problems was developed to aid in this new effort. The BWR progression problems range from 2D lattice calculations to 3D mini-core problems, and reference neutronic solutions were computed using continuous-energy Monte Carlo codes. MPACT, one of the neutronics code in VERA, was benchmarked using the BWR progression problems. The code is capable of computing solutions to all problems. The eigenvalues computed by MPACT agree well with the Monte Carlo reference solutions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modification and validation of an analytical source model for external beam radiotherapy Monte Carlo dose calculations

Purpose: A dose calculation tool, which combines the accuracy of the dose planning method (DPM) Monte Carlo code and the versatility of a practical analytical multisource model, which was previously reported has been improved and validated for the Varian 6 and 10 MV linear accelerators (linacs). The calculation tool can be used to calculate doses in advanced clinical application studies. One shortcoming of current clinical trials that report dose from patient plans is the lack of a standardized dose calculation methodology. Because commercial treatment planning systems (TPSs) have their own dose calculation algorithms and the clinical trial participant who uses these systems is responsible for commissioning the beam model, variation exists in the reported calculated dose distributions. Today’s modern linac is manufactured to tight specifications so that variability within a linac model is quite low. The expectation is that a single dose calculation tool for a specific linac model can be used to accurately recalculate dose from patient plans that have been submitted to the clinical trial community from any institution. The calculation tool would provide for a more meaningful outcome analysis. Methods: The analytical source model was described by a primary point source, a secondary extra-focal source, and a contaminant electron source. Off-axis energy softening and fluence effects were also included. The additions of hyperbolic functions have been incorporated into the model to correct for the changes in output and in electron contamination with field size. A multileaf collimator (MLC) model is included to facilitate phantom and patient dose calculations. An offset to the MLC leaf positions was used to correct for the rudimentary assumed primary point source. Results: Dose calculations of the depth dose and profiles for field sizes 4 × 4 to 40 × 40 cm agree with measurement within 2% of the maximum dose or 2 mm distance to agreement (DTA) for 95% of the data points tested. The model was capable of predicting the depth of the maximum dose within 1 mm. Anthropomorphic phantom benchmark testing of modulated and patterned MLCs treatment plans showed agreement to measurement within 3% in target regions using thermoluminescent dosimeters (TLD). Using radiochromic film normalized to TLD, a gamma criteria of 3% of maximum dose and 2 mm DTA was applied with a pass rate of least 85% in the high dose, high gradient, and low dose regions. Finally, recalculations of patient plans using DPM showed good agreement relative to a commercial TPS when comparing dose volume histograms and 2D dose distributions. Conclusions: A unique analytical source model coupled to the dose planning method Monte Carlo dose calculation code has been modified and validated using basic beam data and anthropomorphic phantom measurement. While this tool can be applied in general use for a particular linac model, specifically it was developed to provide a singular methodology to independently assess treatment plan dose distributions from those clinical institutions participating in National Cancer Institute trials.

60 APPLIED LIFE SCIENCES↗

A Primer on Nuclear "Recoil" Data

For many years the ENDF-6 format has existed to contain evaluated nuclear data. One primary driver for the format and the data is neutron transport calculations. Evaluated data can be processed by a code like NJOY into either continuous energy form (ACE format) for Monte Carlo codes like MCNP or into multi-group form (NDI tables) for deterministic codes like Partisn. The reaction cross sections are found in the MF 3 section of the ENDF-6 format. If the reaction produces one or more neutrons as outputs, then secondary neutron data must also be given in MF 4,5 or 6 sections of the format. Energy and angular distributions for the output neutrons must be given in one of several available formats. The most general formats are found in MF 6. MF 4 is for angular distributions, MF 5 is for Energy distributions, and MF 6 contains both. In recent years, more interest has developed in the other output particles (i.e., the “recoil” particles) from neutron induced reactions. This has been driven by interest in charged particle transport and in more specialized partial kermas. ( A separate total neutron kerma has been available for a long time.) Partial kermas are a breakdown of the Kinetic Energy Released into the MAterial by output particle or by neutron reaction. The sum of the partial kermas should be equal to the total kerma on a group-wise basis. The ENDF-6 format is general enough for these new data requirements. Ideally, evaluated data would exist for every output particle (including the secondary neutrons) from every neutron-induced reaction. In the MF 6 format section, data for multi-particle outputs may be entered using the LAW =1 option. This option explicitly allows energy and angular output distributions for each particle produced in the reaction. Such information should preserve the balance between partial kermas and the total kerma at the groupwise level as well as the individual particle averaged energies. For simpler 2-body reactions, LAW = 2 is available. This allows the evaluation to specify only enough data to specify the 2-body reaction fully. Such a simplification does not exist for 3 (or more) body breakups. A simplified form of LAW 2, i.e., LAW 3, also exists to generate approximate recoil output distributions in the absence of full data. However, evaluated data does not generally exist at this fine granularity for reactions involving more than 2 output particles ( e.g., the 3-body break-up reaction). When the multi-body detailed output distribution data is not available, LAW=6 may be employed in NJOY. LAW 6 produces approximate output distributions for all the particles produced in the reaction. Just like in the 2-body case, the smaller particles will generally carry off more energy. At any particular energy, the balance between the sum of the partial kermas and the total kerma will not necessarily be preserved. However, the average energy of each output particle from a reaction is preserved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALE 6.2 REACTOR PHYSICS CODE ACCURACY ASSESMENT FOR LIGHT WATER REACTOR FUEL

Verification and validation results of the SCALE 6.2 lattice physics codes TRITON/NEWT and Polaris are presented. The SCALE/KENO continuous energy Monte-Carlo code is used as a reference to compare results of more than 2,000 combinations of pressurized water reactor and boiling water reactor lattice designs and state points. Radiochemical assay measurements were also used to assess the accuracy of depletion calculations. Results show that Polaris and TRITON/NEWT using ENDF/B_VII.1 produce accurate lattice physics calculations and cross section data for core simulators.

Mertyurek, Ugur↗

Library for RF Interactions in Orbit Following Codes

A new code-library has been developed to handle quasi-linear wave particle interactions in orbit following Monte Carlo codes, RFOF (RF interactions in Orbit Following codes). This library will enable a large number of orbit following codes to model fast ion acceleration during ICRF and Lower Hybrid heating. The RFOF consists of two main modules: one evaluates the resonance condition, the other the resulting RF acceleration. The resonance condition is tested at each step along the orbit and the location of the next upcoming resonance is predicted. When a particle reaches the resonance, a quasi-linear acceleration is calculated with a novel Monte Carlo technique that avoids the time-consuming evaluation of phase-space derivatives of the interaction strength. In RFOF the wave-particles interactions are assumed to be localized to a single point on the orbit. This is often valid for the ion cyclotron and lower hybrid frequency ranges, but prevents the treatment of bounce and precessional resonances. The RFOF has been developed within the European Task Force for Integrated Tokamak Modelling, enabling interaction between experts in different fields. As a result the code is designed with a simple and generic interface, with a minimum of assumptions on e.g. the geometry. Successful integration with the two orbit following codes, ASCOT and SPOT, has already been demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo Estimates of Eigenvalue Sensitivity to System Dimensions using Kernel Density Estimators

In the last decade there has been an increasing interest in calculating sensitivity coefficients in order to quantify the impact of uncertainty in material properties and system parameters on quantities of interest. Extensive work has been done developing Monte Carlo methods to estimate eigenvalue sensitivity to material properties. While deterministic methods exist for determining the eigenvalue sensitivity to system dimensions, the use of Monte Carlo methods to efficiently calculate eigenvalue sensitivity coefficients to system dimensions is still an open topic. Current Monte Carlo methods for calculating eigenvalue sensitivity coefficients to system dimensions are inefficient. Direct Monte Carlo perturbations require two additional simulations of high statistical precision in order to determine the eigenvalue sensitivity to the location of a single boundary. If the sensitivity to the location of multiple surfaces are desired, two additional simulations must be run for each surface. Kiedrowski and Favorite extended continuous energy Monte Carlo methods for sensitivities of nuclear cross sections to calculate sensitivities to interface boundaries or system dimensions to create the only current alternative to direct Monte Carlo calculations. However this method relies on the simulation of additional random walks launched at each surface crossing event. The present method extends upon Kiedrowski's work and eliminates the inefficient portions of the calculation through the use of Kernel Density Estimators (KDEs). The new method efficiently estimates eigenvalue sensitivities to the uniform expansion or contraction of material interface boundaries or system dimensions, negligibly impacting the runtime performance of the Monte Carlo code. The new estimator is tested on bare and reflected critical configurations in spherical geometry and is compared to estimates obtained from direct Monte Carlo perturbations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of continuous energy sensitivity coefficients calculations in the MORET 5 code - 14269

A continuous-energy sensitivity coefficients calculation capability has been developed in the MORET 5 Monte Carlo code recently. As discussed in this paper, it relies on the differential operator method, an adjoint weighting model (to avoid calculating the fission source derivatives) and a constrained sensitivity coefficient model for sensitivity profiles to distributions such as, for instance, the fission spectrum. For now, the coefficients are provided per medium, per isotope, per reaction on an energy binning defined by the user. The sensitivity coefficients are currently available for the following quantities: total, elastic scattering, total inelastic scattering, fission, total capture and radiative capture cross sections, average neutron produced by fission and fission spectrum. This paper deals with the validation of this new feature in the MORET code on several benchmarks and applications with various energy spectra and geometrical configurations. This validation is performed through the UACSA expert group and the Jezebel ICSBEP benchmarks, but also thanks to calculations performed in the frame of experimental program design in the STACY facility. Comparisons are made using the MCNP6.1 code and the SCALE6.1 package as references. Preliminary results show a pretty good agreement between the different software. (authors)

42 ENGINEERING↗

(U) Introduction to Monte Carlo Methods

Monte Carlo methods are very valuable for representing solutions to particle transport problems. Here we describe a “cook book” approach to handling the terms in a transport equation using Monte Carlo methods. Focus is on the mechanics of a numerical Monte Carlo code, rather than the mathematical foundations of the method.

97 MATHEMATICS AND COMPUTING↗

TU-EF-304-10: Efficient Multiscale Simulation of the Proton Relative Biological Effectiveness (RBE) for DNA Double Strand Break (DSB) Induction and Bio-Effective Dose in the FLUKA Monte Carlo Radiation Transport Code

Purpose: One of the more critical initiating events for reproductive cell death is the creation of a DNA double strand break (DSB). In this study, we present a computationally efficient way to determine spatial variations in the relative biological effectiveness (RBE) of proton therapy beams within the FLUKA Monte Carlo (MC) code. Methods: We used the independently tested Monte Carlo Damage Simulation (MCDS) developed by Stewart and colleagues (Radiat. Res. 176, 587–602 2011) to estimate the RBE for DSB induction of monoenergetic protons, tritium, deuterium, hellium-3, hellium-4 ions and delta-electrons. The dose-weighted (RBE) coefficients were incorporated into FLUKA to determine the equivalent {sup 6}°60Co γ-ray dose for representative proton beams incident on cells in an aerobic and anoxic environment. Results: We found that the proton beam RBE for DSB induction at the tip of the Bragg peak, including primary and secondary particles, is close to 1.2. Furthermore, the RBE increases laterally to the beam axis at the area of Bragg peak. At the distal edge, the RBE is in the range from 1.3–1.4 for cells irradiated under aerobic conditions and may be as large as 1.5–1.8 for cells irradiated under anoxic conditions. Across the plateau region, the recorded RBE for DSB induction is 1.02 for aerobic cells and 1.05 for cells irradiated under anoxic conditions. The contribution to total effective dose from secondary heavy ions decreases with depth and is higher at shallow depths (e.g., at the surface of the skin). Conclusion: Multiscale simulation of the RBE for DSB induction provides useful insights into spatial variations in proton RBE within pristine Bragg peaks. This methodology is potentially useful for the biological optimization of proton therapy for the treatment of cancer. The study highlights the need to incorporate spatial variations in proton RBE into proton therapy treatment plans.

60 APPLIED LIFE SCIENCES↗

Monte Carlo calculation of monitor unit for electron arc therapy

Purpose: Monitor unit (MU) calculations for electron arc therapy were carried out using Monte Carlo simulations and verified by measurements. Variations in the dwell factor (DF), source-to-surface distance (SSD), and treatment arc angle ({alpha}) were studied. Moreover, the possibility of measuring the DF, which requires gantry rotation, using a solid water rectangular, instead of cylindrical, phantom was investigated. Methods: A phase space file based on the 9 MeV electron beam with rectangular cutout (physical size=2.6x21 cm{sup 2}) attached to the block tray holder of a Varian 21 EX linear accelerator (linac) was generated using the EGSnrc-based Monte Carlo code and verified by measurement. The relative output factor (ROF), SSD offset, and DF, needed in the MU calculation, were determined using measurements and Monte Carlo simulations. An ionization chamber, a radiographic film, a solid water rectangular phantom, and a cylindrical phantom made of polystyrene were used in dosimetry measurements. Results: Percentage deviations of ROF, SSD offset, and DF between measured and Monte Carlo results were 1.2%, 0.18%, and 1.5%, respectively. It was found that the DF decreased with an increase in {alpha}, and such a decrease in DF was more significant in the {alpha} range of 0 deg. - 60 deg. than 60 deg. - 120 deg. Moreover, for a fixed {alpha}, the DF increased with an increase in SSD. Comparing the DF determined using the rectangular and cylindrical phantom through measurements and Monte Carlo simulations, it was found that the DF determined by the rectangular phantom agreed well with that by the cylindrical one within {+-}1.2%. It shows that a simple setup of a solid water rectangular phantom was sufficient to replace the cylindrical phantom using our specific cutout to determine the DF associated with the electron arc. Conclusions: By verifying using dosimetry measurements, Monte Carlo simulations proved to be an alternative way to perform MU calculations effectively for electron arc therapy. Since Monte Carlo simulations can generate a precalculated database of ROF, SSD offset, and DF for the MU calculation, with a reduction in human effort and linac beam-on time, it is recommended that Monte Carlo simulations be partially or completely integrated into the commissioning of electron arc therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electron transport algorithms in the Integrated Tiger Series (ITS) codes - 25576

We describe the three electron-transport algorithms that have been implemented in the ITS Monte Carlo codes. While the underlying cross-section data is similar, each uses a fundamentally unique method, which at a high level are best characterized as condensed history, multigroup, and single scatter. Through a set of comparisons with experimental data and some comparisons of purely numerical results, we discuss various attributes of each of the algorithms and show some of the defects that can affect results. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Some Notes on Neutron Up-Scattering and the Doppler-Broadening of High-Z Scattering Resonances

When neutrons are scattered by target nuclei at elevated temperatures, it is entirely possible that the neutron will actually gain energy (i.e., up-scatter) from the interaction. This phenomenon is in addition to the more usual case of the neutron losing energy (i.e., down-scatter). Furthermore, the motion of the target nuclei can also cause extended neutron down-scattering, i.e., the neutrons can and do scatter to energies lower than predicted by the simple asymptotic models. In recent years, more attention has been given to temperature-dependent scattering cross sections for materials in neutron multiplying systems. This has led to the inclusion of neutron up-scatter in deterministic codes like Partisn and to free gas scattering models for material temperature effects in Monte Carlo codes like MCNP and cross section processing codes like NJOY. The free gas scattering models have the effect of Doppler Broadening the scattering cross section output spectra in energy and angle. The current state of Doppler-Broadening numerical techniques used at Los Alamos for scattering resonances will be reviewed, and suggestions will be made for further developments. The focus will be on the free gas scattering models currently in use and the development of new models to include high-Z resonance scattering effects. These models change the neutron up-scattering behavior.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of fast-ion D-alpha spectrum measurements during EAST neutral-beam heated plasmas

To investigate the fast ion behavior, a fast ion D-alpha (FIDA) diagnostic system has been installed on EAST. Fast ion features can be inferred from the Doppler shifted spectrum of Balmer-alpha light from energetic hydrogenic atoms. This paper will focus on the validation of FIDA measurements performed using MHD-quiescent discharges in 2015 campaign. Two codes have been applied to calculate the D{sub α} spectrum: one is a Monte Carlo code, Fortran 90 version FIDASIM, and the other is an analytical code, Simulation of Spectra (SOS). The predicted SOS fast-ion spectrum agrees well with the measurement; however, the level of fast-ion part from FIDASIM is lower. The discrepancy is possibly due to the difference between FIDASIM and SOS velocity distribution function. The details will be presented in the paper to primarily address comparisons of predicted and observed spectrum shapes/amplitudes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and application of a hybrid transport methodology for active interrogation systems

A hybrid Monte Carlo and deterministic methodology has been developed for application to active interrogation systems. The methodology consists of four steps: i) neutron flux distribution due to neutron source transport and subcritical multiplication; ii) generation of gamma source distribution from (n, 7) interactions; iii) determination of gamma current at a detector window; iv) detection of gammas by the detector. This paper discusses the theory and results of the first three steps for the case of a cargo container with a sphere of HEU in third-density water cargo. To complete the first step, a response-function formulation has been developed to calculate the subcritical multiplication and neutron flux distribution. Response coefficients are pre-calculated using the MCNP5 Monte Carlo code. The second step uses the calculated neutron flux distribution and Bugle-96 (n, 7) cross sections to find the resulting gamma source distribution. In the third step the gamma source distribution is coupled with a pre-calculated adjoint function to determine the gamma current at a detector window. The AIMS (Active Interrogation for Monitoring Special-Nuclear-Materials) software has been written to output the gamma current for a source-detector assembly scanning across a cargo container using the pre-calculated values and taking significantly less time than a reference MCNP5 calculation. (authors)

97 MATHEMATICS AND COMPUTING↗

Time-resolved ionization measurements with intense ultrashort XUV and X-ray free-electron laser pulses

Abstract Modern free-electron lasers (FEL) operating in XUV (extreme ultraviolet) or X-ray range allow an access to novel research areas. One instance is the ultrafast ionization of a solid by an intense femtosecond FEL pulse in XUV which consequently leads to a change of the complex index of refraction on an ultrashort timescale. The photoionization and subsequent impact ionization resulting in electronic and atomic dynamics are modeled with our hybrid code XTANT(X-ray thermal and non-thermal transitions) and a Monte Carlo code XCASCADE(X-ray-induced electron cascades). The simulations predict the temporal kinetics of FEL-induced electron cascades and thus yield temporally and spatially resolved information on the induced changes of the optical properties. In a series of experiments at FERMI and LCLS, single shot measurements with spatio-temporal encoding of the ionization process have been performed by a correlation of the FEL pump pulse with an optical femtosecond probe pulse. An excellent agreement between the experiment and the simulation has been found. Furthermore, we demonstrate that such kind of experiments forms the basis for pulse duration and arrival time jitter monitoring as currently under development for XUV-FELs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

"K-Effective of the World" and Other Concerns for Monte Carlo Eigenvalue Calculations

Monte Carlo methods have been used to compute k eff and the fundamental model eigenfunction of critical systems since the 1950s. Despite the sophistication of today's Monte Carlo codes for representing realistic geometry and physics interactions, correct results can be obtained in criticality problems only if users pay attention to source convergence in the Monte Carlo iterations and to running a sufficient number of neutron histories to adequately sample all significant regions of the problem. Recommended best practices for criticality calculations are reviewed and applied to several practical problems for nuclear reactors and criticality safety, including the "K-effective of the World" problem. Numerical results illustrate the concerns about convergence and bias. The general conclusion is that with today's high-performance computers, improved understanding of the theory, new tools for diagnosing convergence (e.g., Shannon entropy of the fission distribution), and clear practical guidance for performing calculations, practitioners will have a greater degree of confidence than ever of obtaining correct results for Monte Carlo criticality calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Time and Energy Characterization of a Neutron time of Flight Detector for Re-designing Line of Sight 270 at the Z Pulsed Power Facility.

This work will focus on the characterization of NTOF detectors fielded on ICF experiments conducted at the Z-experimental facility with emphasis on the MagLif and gas puff campaigns. Three experiments have been proposed. The first experiment will characterize the response of the PMT with respect to the amplitude and width of signals produced by single neutron events. A second experiment will characterize the neutron transit time through the scintillator and the third is to characterize the pulse amplitude for a very specific range of neutron induced charged particle interactions within the scintillator. These experiments will cover incident neutron energies relevant to D-D and D-T fusion reactions. These measurements will be taken as a function of detector bias to cover the entire dynamic range of the detector. Throughout the characterization process, the development of a predictive capability is desired. A new post processing code has been proposed that will calculate a neutron time-of-flight spectrum in units of MeVee. This code will couple the experimentally obtained values and the results obtained with the Monte Carlo code MCNP6. The motivation of this code is to correct for geometry issues when transferring the calibration results from a light lab setting to the Zenvironment. This capability will be used to develop a hypothetical design of LOS270 such that more favorable neutron measurements, requiring less correction, can be made in the future.

47 OTHER INSTRUMENTATION↗