Search NASA⌕ Search

SEARCH · Search NASA

Results for “National Transonic Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Transonic Symposium: Theory, Application and Experiment, volume 2

Papers presented at the Transonic Symposium are compiled. The following subject areas are covered: National Transonic Facility status; transonic aerodynamics of slender wing-body configuration; laminar flow flight experiments; laminar flow wind tunnel experiments; computational support of X-29A flight experiment; transition location on a clean-up glove installed on a F-14 aircraft; and design studies for a laminar glove for the X-29 aircraft.

Foughner, Jerome T., Jr.↗

Reynolds number effects on the transonic aerodynamics of a slender wing-body configuration

Aerodynamic forces and moments for a slender wing-body configuration are summarized from an investigation in the Langley National Transonic Facility (NTF). The results include both longitudinal and lateral-directional aerodynamic properties as well as slideslip derivatives. Results were selected to emphasize Reynolds number effects at a transonic speed although some lower speed results are also presented for context. The data indicate nominal Reynolds number effects on the longitudinal aerodynamic coefficients and more pronounced effects for the lateral-directional aerodynamic coefficients. The Reynolds number sensitivities for the lateral-directional coefficients were limited to high angles of attack.

Luckring, James M.↗

User guide for WIACX: A transonic wind-tunnel wall interference assessment and correction procedure for the NTF

A three dimensional transonic Wind-tunnel Interference Assessment and Correction (WIAC) procedure developed specifically for use in the National Transonic Facility (NTF) at NASA Langley Research Center is discussed. This report is a user manual for the codes comprising the correction procedure. It also includes listings of sample procedures and input files for running a sample case and plotting the results.

Garriz, Javier A.↗

Weight, center of gravity and modal test report for NTF fan blade set no. 3

A complete set of fan blades for the National Transonic Facility (NTF) at the NASA Langley Research Center was recently fabricated by Dynamic Engineering Inc. (DEI). These blades were the third complete set of blades fabricated by the NTF. The first set of blades was fabricated by NASA and installed in the tunnel in December 1981. This original set was destroyed in a mishap in January 1989. The second set of blades is currently in use in the NTF. The third set of blades recently fabricated by DEI is a spare set. In order to ensure that the blades met the requirements, DEI performed a series of tests on each of the completed blades. In addition, a model survey was conducted on each blade to define the dynamic characteristics. Discussed here are the blade tests conducted by DEI and the test results. The test set-ups and procedures are discussed in detail. The results obtained for each of the 27 blades are documented and comparisons are made between this set of blades and similar data for two previous sets of NTF fan blades.

Friedman, Inger P.↗

On the measurement of subsonic flow around an appended body of revolution at cryogenic conditions in the NTF

Fluid mechanics scaling is briefly reviewed and testing ship models at high Reynolds numbers in the National Transonic Facility is discussed. Particular attention is given to the 1986 body of revolution experiment, the expanded model capabilities for a future body of revolution experiment, major features of a future flat plate experiment, the proposed liquid helium tunnel from the user's point of view, and a comparison of the NTF and the Conceptual Helium Tunnel.

Coder, David W.↗

Control of large cryogenic tunnels

For the efficient and economic operation of large cryogenic wind tunnels, automatic control is necessary to precisely regulate the temperature, pressure, and Mach number. The features of the control system currently in operation at the U.S. National Transonic Facility are presented. Some unique features of the tunnel temperature control law are the automatic tunnel cool down utilizing structural temperature feedback and the fan power based liquid nitrogen nozzle switching logic that have played a key role in realizing good automatic tunnel control.

Balakrishna, S.↗

An approach for increasing aeroelastic divergence dynamic pressure of wind-tunnel models

An approach for increasing the aeroelastic divergence dynamic pressure of wind-tunnel model support systems is presented. A study has been conducted to investigate the effect of increased flexibility of the forward portion of balances on the divergence pressure of wind-tunnel models. The study utilized prior divergence analyses completed for various models to be tested in NASA Langley Research Center's National Transonic Facility, the Engineering Analysis Language finite-element analysis code, and an in-house computer program which solves for divergence dynamic pressure utilizing a transfer-matrix method based on fourth-order Runge-Kutta integration. Analytical results for balance flexibility changes versus changes in divergence pressure were obtained and demonstrate that a significant increase in divergence pressure can be obtained from the increased flexibility of the balance's forward portion for many models and their support systems.

Edwards, R. W.↗

Wind Tunnel Modeling Seminar

The NASA Altitude Wind Tunnel (AWT) program was examined and reviewed. AWT project status and modeling program are presented as well as the modeling programs for a number of other wind tunnels such as the National Transonic Facility, Boeing tunnel, and NASA's 40 by 80 by 120 foot tunnel. Finally, AWT aerodynamic design status, aerothermodynamic design, drive system, icing equipment, acoustics, and dynamics and controls are discussed. The need for this tunnel is examined in the wake of new aerospace research programs. All documents are presented in viewgraph format.

Source record↗

NTF Modeling Program

The National Transonic Facility presents a design for and assessment of a transonic wind tunnel. Among the topics covered in viewgraph format are: aerodynamic validation models, scale models of wind tunnel components, performance evaluations of various wind tunnel parameters, and drive systems.

McKinney, L. Wayne↗

Navier-Stokes calculation of transonic flow past the NTF 65-deg delta wing

Viscous flow past a wind tunnel model of a 65-degree swept angle Delta wing at transonic speeds is being studied. The model was tested in the 8-foot cryogenic transonic wind tunnel at the National Transonic Facility. Aerodynamic forces and wing surface pressure data were obtained at various angles of attack, Mach numbers, and Reynold's numbers for four different leading edges of the wing. The objectives of the present investigation are: (1) to perform numerical modeling of the flow around the wing; (2) to validate the experimental data with a Navier-Stokes computational fluid dynamics code and vice versa; (3) to investigate the effects of the sting mount of the wing; (4) to evaluate the effects of leading edge radius on the flow; and (5) to explain the Reynold's number effect as indicated by the test data. Several computer programs were developed to define the surfaces of the wing, the four leading edges, and the sting mount. Based on these geometric databases, the surface grids of a single-block computational domain was generated interactively on the IRIS workstation using the GRIDGEN2D module of GRIDGEN. To refine the grids and to avoid excessive loss of grid points due to collapsed edges, a 9-block computational domain containing approximately 750,000 grid points was developed with the GRIDBLOCK module to replace the single-block grid.

Wu, Chivey↗

Application of a neural network as a potential aid in predicting NTF pump failure

The National Transonic Facility has three centrifugal multi-stage pumps to supply liquid nitrogen to the wind tunnel. Pump reliability is critical to facility operation and test capability. A highly desirable goal is to be able to detect a pump rotating component problem as early as possible during normal operation and avoid serious damage to other pump components. If a problem is detected before serious damage occurs, the repair cost and downtime could be reduced significantly. A neural network-based tool was developed for monitoring pump performance and aiding in predicting pump failure. Once trained, neural networks can rapidly process many combinations of input values other than those used for training to approximate previously unknown output values. This neural network was applied to establish relationships among the critical frequencies and aid in predicting failures. Training pairs were developed from frequency scans from typical tunnel operations. After training, various combinations of critical pump frequencies were propagated through the neural network. The approximated output was used to create a contour plot depicting the relationships of the input frequencies to the output pump frequency.

Rogers, James L.↗

Analysis of Fluctuating Static Pressure Measurements in a Large High Reynolds Number Transonic Cryogenic Wind Tunnel

Dynamic measurements of fluctuating static pressure levels were made using flush mounted high frequency response pressure transducers at eleven locations in the circuit of the National Transonic Facility (NTF) over the complete operating range of this wind tunnel. Measurements were made at test section Mach numbers from 0.2 to 1.2, at pressure from 1 to 8.6 atmospheres and at temperatures from ambient to -250 F, resulting in dynamic flow disturbance measurements at the highest Reynolds numbers available in a transonic ground test facility. Tests were also made independently at variable Mach number, variable Reynolds number, and variable drivepower, each time keeping the other two variables constant thus allowing for the first time, a distinct separation of these three important variables. A description of the NTF emphasizing its flow quality features, details on the calibration of the instrumentation, results of measurements with the test section slots covered, downstream choke, effects of liquid nitrogen injection and gaseous nitrogen venting, comparisons between air and nitrogen, isolation of the effects of Mach number, Reynolds number, and fan drive power, and identification of the sources of significant flow disturbances is included. The results indicate that primary sources of flow disturbance in the NTF may be edge-tones generated by test section sidewall re-entry flaps and the venting of nitrogen gas from the return leg of the tunnel circuit between turns 3 and 4 in the cryogenic mode of operation. The tests to isolate the effects of Mach number, Reynolds number, and drive power indicate that Mach number effects predominate. A comparison with other transonic wind tunnels shows that the NTF has low levels of test section fluctuating static pressure especially in the high subsonic Mach number range from 0.7 to 0.9.

Igoe, William B.↗

A PC-based simulation of the National Transonic Facitity's safety microprocessor

A brief study was undertaken to demonstrate the feasibility of using a state-of-the-art off-the-shelf high speed personal computer for simulating a microprocessor presently used for wind tunnel safety purposes at Langley Research Center's National Transonic Facility (NTF). Currently, there is no active display of tunnel alarm/alert safety information provided to the tunnel operators, but rather such information is periodically recorded on a process monitoring computer printout. This does not provide on-line situational information nor permit rapid identification of safety operational violations which are able to halt tunnel operations. It was therefore decided to simulate the existing algorithms and briefly evaluate a real-time display which could provide both position and trouble shooting information.

Thibodeaux, J. J.↗

Aerodynamic investigation with focusing schlieren in a cryogenic wind tunnel

A flow visualization study was performed using a focusing schlieren system in the 0.3m Transonic Cryogenic Tunnel at NASA Langley Research Center. The design employed proved to be a useful flow visualization tool for flows as low as M = 0.4. This study marked the first verification of the focusing schlieren technique in a major subsonic/transonic wind tunnel, and the first time that high quality, detailed pictures of high-Reynolds number flows were obtained in a cryogenic wind tunnel. This test was part of a development program to implement instrumentation techniques in cryogenic wind tunnels, with the ultimate aim to use them in the National Transonic Facility (NTF).

Gartenberg, Ehud↗

Testing experience with unheated stain-gage balances in the NTF

A series of cryogenic (cryo) cycles was conducted in the cryo chamber at the National Transonic Facility (NTF) in order to identify the cause of apparent strain shifts in axial force with temperature for the Pathfinder I model and to minimize their effects. The results of the investigation indicated that the major cause of axial force end point shifts and thermal hysteresis loops was the thickness of the Teflon insulation on the instrumentation wires crossing the balance. By reducing the thickness of the insulation and the total number and size of the wires, apparent strain values were achieved for the model with instrumentation wires which were nearly identical to those for the model without wires. Because of the special design features used, the balance output was very accurate and repeatable over the entire NTF temperature range, even with balance thermal gradients as large as 64 F and transient conditions as large as 3 F/minute.

Jacobs, Peter F.↗

Analysis of aeroelastic and resonance responses of a wind tunnel model support system

Vibrations of the National Transonic Facility model support system were analyzed using CAP-TSD (Computational Aeroelasticity Program-Transonic Small Disturbance), a three-dimensional transonic small disturbance potential code designed for aeroelastic analysis of complex configurations. The model support system was represented as a tunnel-spanning flexible wing whose structural properties were obtained from measured responses. Aeroelastic transients were calculated, assuming no structural damping, and analyzed to obtain modal stability characteristics. The results showed that there is a tendency toward a hump mode instability in one of the modes and that there are other weakly damped or unstable modes. The close proximity of the solid wind-tunnel diffuser side walls to the model support system was shown to have adverse effects on its aeroelastic stability characteristics. When the effects of the wind-tunnel walls were modeled, the analyses indicated the presence of wind-tunnel resonance modes which were not present when free-air boundary conditions were used.

Whitlow, Woodrow, Jr.↗

Evaluation of the prototype dual-axis wall attitude measurement sensor

A prototype dual-axis electrolytic tilt sensor package for angular position measurements was built and evaluated in a laboratory environment. The objective was to investigate the use of this package for making wind tunnel wall attitude measurements for the National Transonic Facility (NTF) at NASA Langley Research Center (LaRC). The instrumentation may replace an existing, more costly, and less rugged servo accelerometer package (angle-of-attack package) currently in use. The dual-axis electrolytic tilt sensor package contains two commercial electrolytic tilt sensors thermally insulated with NTF foam, all housed within a stainless steel package. The package is actively heated and maintained at 160 F using foil heating elements. The laboratory evaluation consisted of a series of tests to characterize the linearity, repeatability, cross-axis interaction, lead wire effect, step response, thermal time constant, and rectification errors. Tests revealed that the total RMS errors for the x-axis sensor is 0.084 degree, and 0.182 degree for the y-axis sensor. The RMS errors are greater than the 0.01 degree specification required for NTF wall attitude measurements. It is therefore not a viable replacement for the angle-of-attack package in the NTF application. However, with some physical modifications, it can be used as an inexpensive 5-degree range dual-axis inclinometer with overall accuracy approaching 0.01 degree under less harsh environments. Also, the data obtained from the tests can be valuable for wind tunnel applications of most types of electrolytic tilt sensors.

Wong, Douglas T.↗

Structural damping studies at cryogenic temperatures

Results of an engineering study to measure changes in structural damping properties of two cryogenic wind tunnel model systems and two metallic test specimens at cryogenic temperatures are presented. Data are presented which indicate overall, a trend toward reduced structural damping at cryogenic temperatures (-250 degrees F) when compared with room temperature damping properties. The study was focused on structures and materials used for model systems tested in the National Transonic Facility (NTF). The study suggests that the significant reductions in damping at extremely cold temperatures are most likely associated with changes in mechanical joint compliance damping rather than changes in material (solid) damping.

Young, Clarence P., Jr.↗