Search NASA⌕ Search

SEARCH · Search NASA

Results for “Occupancy estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Strategy Guideline: Energy Retrofits for Low-Rise Multifamily Buildings in Cold Climates

This Strategy Guideline explains the benefits of evaluating and identifying energy efficiency retrofit measures that could be made during renovation and maintenance of multifamily buildings. It focuses on low-rise multifamily structures (three or fewer stories) in a cold climate. These benefits lie primarily in reduced energy use, lower operating and maintenance costs, improved durability of the structure, and increased occupant comfort. This guideline focuses on retrofit measures for roof repair or replacement, exterior wall repair or gut rehab, and eating system maintenance. All buildings are assumed to have a flat ceiling and a trussed roof, wood- or steel-framed exterior walls, and one or more single or staged boilers. Estimated energy savings realized from the retrofits will vary, depending on the size and condition of the building, the extent of efficiency improvements, the efficiency of the heating equipment, the cost and type of fuel, and the climate location.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermalized axion inflation

We analyze the dynamics of inflationary models with a coupling of the inflaton φ to gauge fields of the form φ F F-tilde / f , as in the case of axions. It is known that this leads to an instability, with exponential amplification of gauge fields, controlled by the parameter ξ= φ-dot /(2 fH ), which can strongly affect the generation of cosmological perturbations and even the background. We show that scattering rates involving gauge fields can become larger than the expansion rate H , due to the very large occupation numbers, and create a thermal bath of particles of temperature T during inflation. In the thermal regime, energy is transferred to smaller scales, radically modifying the predictions of this scenario. We thus argue that previous constraints on ξ are alleviated. If the gauge fields have Standard Model interactions, which naturally provides reheating, they thermalize already at ξ∼>2.9, before perturbativity constraints and also before backreaction takes place. In absence of SM interactions (i.e. for a dark photon), we find that gauge fields and inflaton perturbations thermalize if ξ∼>3.4; however, observations require ξ∼>6, which is above the perturbativity and backreaction bounds and so a dedicated study is required. After thermalization, though, the system should evolve non-trivially due to the competition between the instability and the gauge field thermal mass. If the thermal mass and the instabilities equilibrate, we expect an equilibrium temperature of T {sub eq} ≅ ξ H / g-bar where g-bar is the effective gauge coupling. Finally, we estimate the spectrum of perturbations if φ is thermal and find that the tensor to scalar ratio is suppressed by H /(2 T ), if tensors do not thermalize.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of Airframe and Occupant Models for Two Full-Scale Rotorcraft Crash Tests

Two full-scale crash tests of an MD-500 helicopter were conducted in 2009 and 2010 at NASA Langley's Landing and Impact Research Facility in support of NASA s Subsonic Rotary Wing Crashworthiness Project. The first crash test was conducted to evaluate the performance of an externally mounted composite deployable energy absorber under combined impact conditions. In the second crash test, the energy absorber was removed to establish baseline loads that are regarded as severe but survivable. Accelerations and kinematic data collected from the crash tests were compared to a system integrated finite element model of the test article. Results from 19 accelerometers placed throughout the airframe were compared to finite element model responses. The model developed for the purposes of predicting acceleration responses from the first crash test was inadequate when evaluating more severe conditions seen in the second crash test. A newly developed model calibration approach that includes uncertainty estimation, parameter sensitivity, impact shape orthogonality, and numerical optimization was used to calibrate model results for the second full-scale crash test. This combination of heuristic and quantitative methods was used to identify modeling deficiencies, evaluate parameter importance, and propose required model changes. It is shown that the multi-dimensional calibration techniques presented here are particularly effective in identifying model adequacy. Acceleration results for the calibrated model were compared to test results and the original model results. There was a noticeable improvement in the pilot and co-pilot region, a slight improvement in the occupant model response, and an over-stiffening effect in the passenger region. This approach should be adopted early on, in combination with the building-block approaches that are customarily used, for model development and test planning guidance. Complete crash simulations with validated finite element models can be used to satisfy crash certification requirements, thereby reducing overall development costs.

Annett, Martin S.↗

Aggregate residential demand flexibility behavior: A novel assessment framework

Residential demand flexibility (DF) could save the U.S. electric grid up to 10 GW of peak demand while supporting increased amounts of renewable generation. However, less than 40% of the estimated DF peak reduction capacity is currently realized, and less than 8% of American households are enrolled. These low participation rates are combined with high rates of "overriding" a DF event and eventual opt-outs among enrolled customers. There is still not a comprehensive understanding of the drivers of DF participation and occupant interaction with DF program signals. We, therefore, present a novel survey processing framework to assess occupant DF-relevant behavior from the American Time Use Survey (ATUS). Using the framework, we summarize both the extensive and intensive behavior of more than 200,000 ATUS respondents (2003-2018 data) and provide insights on the DF-relevant behavior of residential occupants, which is generally overlooked in the literature. Here we use the framework to identify the activity priorities of residential occupants in the United States during different DF-relevant periods (critical peak, peak, and off-peak). These preferred activities capture overlooked routine behaviors that could be barriers to DF participation, if ignored, and might explain the high levels of overrides often exhibited by participants of demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A path integral ground state Monte Carlo algorithm for entanglement of lattice bosons

A ground state path integral quantum Monte Carlo algorithm is introduced that allows for the study of entanglement in lattice bosons at zero temperature. The Rényi entanglement entropy between spatial subregions is explored across the phase diagram of the one dimensional Bose-Hubbard model for systems consisting of up to L=256 L = 256 sites at unit-filling without any restrictions on site occupancy, far beyond the reach of exact diagonalization. The favorable scaling of the algorithm is demonstrated through a further measurement of the Rényi entanglement entropy at the two dimensional superfluid-insulator critical point for large system sizes, confirming the existence of the expected entanglement boundary law in the ground state. The Rényi estimator is extended to measure the symmetry resolved entanglement that is operationally accessible as a resource for experimentally relevant lattice gases with fixed total particle number.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wynkoop Building Performance Measurement: Water

This report is a summary of the water analysis performance for the Denver, Colorado Wynkoop Building. The Wynkoop Building (Figure 1) was built in 2006 as the Environmental Protection Agency (EPA) Region 8 Headquarters intended to house over 900 occupants in the 301,292 gross square feet (248,849 rentable square feet). The building was built on a brownfield in the Lower Downtown Historic District as part of an urban redevelopment effort. The building was designed and constructed through a public-private partnership with the sustainable design elements developed jointly by General Services Administration (GSA) and EPA. That partnership is still active with all parties still engaged to optimize building operations and use the building as a Learning Laboratory. The building design achieved U.S. Green Building Council Leadership in Energy and Environmental Design for New Construction (LEED-NC) Gold Certification in 2008 (Figure 2) and a 2008 EPA Energy Star Rating of 96 with design highlights that include: (1) Water use was designed to use 40% less than a typical design baseline. The design included low flow fixtures, waterless urinals and dual flush toilets; (2) Native and adaptive vegetation were selected to minimize the need for irrigation water for landscaping; and (3) Energy use intensity was modeled at 66.1 kBtus/gross square foot, which is 39% better than ASHRAE 90.1 1999. The Wynkoop Building water use (10 gallons/square foot) was measured at lower than industry average (15 gallons/square foot) and GSA goals (13 gallons/square foot), however, it was higher than building management expected it would be. The type of occupants and number of occupants can have a significant impact on fixture water use. The occupancy per floor varied significantly over the study time period, which added uncertainty to the data analysis. Investigation of the fixture use on the 2nd, 5th, and 7th floors identified potential for water use reduction if the flush direction of the dual-flush toilet handles was reversed. The building management retrofitted the building's toilets with handles that operated on reduced flush when pushed down (0.8 gallons) and full flush when pulled up (1.1 gallons). The water pressure on the 5th floor (< 30 psi) is less than half the pressure on the 7th floor (>80 psi). The measured water savings post-retrofit was lower on the 5th floor than the 7th floor. The differences in water pressure may have had an impact on the quantity of water used per floor. The second floor water use was examined prior to and following the toilet fixture retrofit. This floor is where conference rooms for non-building occupants are available for use, thus occupancy is highly variable. The 3-day average volume per flush event was higher post-retrofit (0.79 gallons per event), in contrast to pre-retrofit (0.57 gallons per event). There were 40% more flush events post retrofit, which impacted the findings. Water use in the third floor fitness center was also measured for a limited number of days. Because of water line accessibility, only water use on the men's side of the fitness center was measured and from that the total fitness center water use was estimated. Using the limited data collected, the fitness center shower water use is approximately 2% of the whole building water use. Overall water use in the Wynkoop Building is below the industry baseline and GSA expectations. The dual flush fixture replacement appears to have resulted in additional water savings that are expected to show a savings in the total annual water use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A data engineering approach for sustainable chemical end-of-life management

The presence of chemicals causing significant adverse human health and environmental effects during end-of-life (EoL) stages is a challenge for implementing sustainable management efforts and transitioning towards a safer circular life cycle. Conducting chemical risk evaluation and exposure assessment of potential EoL scenarios can help understand the chemical EoL management chain for its safer utilization in a circular life-cycle environment. However, the first step is to track the chemical flows, estimate releases, and potential exposure pathways. Hence, this work proposes an EoL data engineering approach to perform chemical flow analysis and screening to support risk evaluation and exposure assessment for designing a safer circular life cycle of chemicals. This work uses publicly-available data to identify potential post-recycling scenarios (e.g., industrial processing/use operations), estimate inter-industry chemical transfers, and exposure pathways to chemicals of interest. Furthermore, a case study demonstration shows how the data engineering framework identifies, estimates, and tracks chemical flow transfers from EoL stage facilities (e.g., recycling and recovery) to upstream chemical life cycle stage facilities (e.g., manufacturing). Also, the proposed framework considers current regulatory constraints on closing the recycling loop operations and provides a range of values for the flow allocated to post-recycling uses associated with occupational exposure and fugitive air releases from EoL operations.

54 ENVIRONMENTAL SCIENCES↗

Evaluating the Performance of Island Kitchen Range Hoods

A key aspect of achieving acceptable indoor air quality is source control. Cooking has been recognized as a significant source of pollutants for health impacts (e.g., PM2.5 and NO2) as well as moisture and odour. A common method of controlling this pollutant source is by using a range (or cooker) hood that vents to outside. However, field and laboratory experiments have shown highly variable performance for these devices. We use the capture efficiency metric (the fraction of the pollutants that are exhausted to outside at steady state) to characterize the range hood performance. To address this issue and provide useful information for builders, contractors, designers and home occupants, a laboratory rating method for range hood capture efficiency has recently been developed by LBNL and ASTM. The test method uses standardized emitters to create a heated plume and seed it with tracer gas. The tracer gas measurements in the room, the range hood exhaust and in the ambient air are used to estimate capture efficiency. However, this test method only applies to wall-mounted range hoods. Some range hoods are not wall-mounted: island range hoods are designed to operate over a cooktop in the middle of a room rather than against a wall and downdraft hoods draw air from near the cooktop rather than overhead. This paper discusses the development of a new test apparatus for island and downdraft hoods and presents measured capture efficiency data from example hoods. The results of this work will be used in future revisions to the ASTM standard.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proven Performance of Seven Cold Climate Deep Retrofit Homes

Seven test homes located in Massachusetts are examined within this report. The retrofit strategies of each home are presented along with a comparison of the pre- and post-retrofit airtightness achieved by the group. Pre- and post-retrofit utility bills were collected; energy models were used to estimate pre-retrofit energy use when bills were unavailable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How Does Home Energy Score Affect Home Value and Mortgage Performance?

Energy-efficient homes save their occupants money through lower energy bills. These savings might be capitalized into higher home sale prices. They also improve the household’s net cash flow, which might make households better able to pay mortgage debt. The U.S. Department of Energy (DOE)’s Home Energy Score (HES) assigns a 1-10 score to homes and estimates annual energy bills based on modeled energy consumption. In this paper we investigated the relationship between HES metrics and two housing market outcomes: home sale price and mortgage performance. We found that the relationship was only statistically significant in places with a mandatory HES assessment at the time of sale. Using a sample of 26,291 home sales that occurred after HES assessments, we found that a one-point increase in HES in these locations was associated with a 0.5% increase in sale price, and an increase in $100 of estimated annual energy bills was associated with a 0.4% decrease. This magnitude of effect is consistent with estimated magnitudes of home sale premiums for other green or energy-efficient home certifications in the literature. We also found that a one-point increase in HES was associated with a 5.5% reduction in the odds of a loan going 30 days delinquent if the loan originated after the assessment occurred. Similarly, we found that a $100 decrease in estimated annual energy bills was associated with a 2.3% decrease in the odds of a loan going delinquent if it originated after the assessment occurred. Our results suggest that HES provides a valuable signal for housing market transactions in specific situations.

Pigman, Margaret↗

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES↗

Status of Redband Trout in the Upper Snake River Basin of Idaho

Abstract Redband Trout Oncorhynchus mykiss gairdneri are likely the most abundant and most widely distributed native salmonid in the Columbia River basin, yet their current distribution and abundance across the landscape have not been well documented. We sampled 1,032 randomly distributed stream sites (usually 100 m in length) across more than 60,000 km of stream network to assess Redband Trout occupancy, abundance, and genetic purity in the upper Snake River basin of Idaho. Study locations were more often in dry desert subbasins (49% of sites) than in montane subbasins (20%), and 25% of the dry “stream sites” had no discernible stream channel whatsoever, indicating a lack of flowing water for perhaps millennia. Redband Trout were estimated to occupy 13,485 km of stream (22% of the total) and were captured more often (389 sites) than Brook Trout Salvelinus fontinalis (128 sites), Bull Trout Salvelinus confluentus (37 sites), or Brown Trout Salmo trutta (16 sites). Redband Trout were also the most abundant species of trout, with an approximate abundance of 3,449,000 ± 402,000 (90% confidence interval) of all sizes, followed by Brook Trout (1,501,000 ± 330,000), Bull Trout (159,000 ± 118,000), and Brown Trout (43,000 ± 25,000). Approximately 848,000 ± 128,000 Redband Trout were adults. From 1913 (the earliest year of record) to 2001, roughly 43 million hatchery Rainbow Trout were stocked in streams in the study area, 17.5 million of which were of catchable size (i.e., ≥200 mm total length); since 2001, all catchable trout have been sterilized prior to stocking. Genetic results from 61 study sites suggest that hybridization with hatchery Rainbow Trout is more likely to occur in streams that were directly stocked with catchable trout from 1913 to 2001. Applying these results across the landscape, we estimated that Redband Trout likely remain pure in about 68% of the streams occupied in the upper Snake River basin. Received November 13, 2012; accepted January 9, 2014

Meyer, Kevin A.↗

Analysis of an initial lunar outpost life support system preliminary design

A preliminary design of a life-support system (LSS) was developed as part of an ongoing comprehensive trade study of advanced processor technologies and system architectures for an initial lunar outpost. The design is based on a mission scenario requiring intermittent occupation of a lunar-surface habitat by a crew of four. It incorporates physiochemical process technologies that were considered for Space Station Freedom. A system-level simulation model of the design was developed to obtain steady-state material balances for each LSS processor. The mass-flow rate predictions were used to obtain estimates of the LSS mass, volume, and power consumption by means of processor-sizing correlations that were extrapolated from Space Station Freedom processor designs. The results were used to analyze the impacts of varying crew size, mission duration, processor-operation strategy, and crew-cabin loads on the LSS mass, average power consumption, volume, periodic resupply mass, and waste-accumulation rates. The merits of the design were quantified relative to an open-loop LSS, and the implications of this assessment for future LSS research and technology development were identified.

Ballin, Mark G.↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coccidioidomycosis Dynamics in Relation to Climate in the Southwestern United States: Cocci. and climate in the SW U.S.

Valley fever is endemic to the southwestern United States. Humans contract this fungal disease by inhaling spores of Coccidioides spp. Changes in the environment can influence the abundance and dispersal of Coccidioides spp., causing fluctuations in valley fever incidence. We combined county-level case records from state health agencies to create a regional valley fever database for the southwestern United States, including Arizona, California, Nevada, New Mexico, and Utah. We used this data set to explore how environmental factors influenced the spatial pattern and temporal dynamics of valley fever incidence during 2000–2015. We compiled climate and environmental geospatial data sets from multiple sources to compare with valley fever incidence. These variables included air temperature, precipitation, soil moisture, surface dust concentration, normalized difference vegetation index, and cropland area. We found that valley fever incidence was greater in areas with warmer air temperatures and drier soils. The mean annual cycle of incidence varied throughout the southwestern United States and peaked following periods of low precipitation and soil moisture. From year-to-year, however, autumn incidence was higher following cooler, wetter, and productive springs in the San Joaquin Valley of California. In southcentral Arizona, incidence increased significantly through time. By 2015, incidence in this region was more than double the rate in the San Joaquin Valley. Our analysis provides a framework for interpreting the influence of climate change on valley fever incidence dynamics. Our results may allow the U.S. Centers for Disease Control and Prevention to improve their estimates of the spatial pattern and intensity of valley fever endemicity.

54 ENVIRONMENTAL SCIENCES↗

Determination of the density of the defect states in Hf{sub 0.5}Zr{sub 0.5}O{sub 2} high-k film Deposited by using rf-magnetron sputtering technique

A memory structure Pt/Al{sub 2}O{sub 3}/Hf{sub 0.5}Zr{sub 0.5}O{sub 2}/Al{sub 2}O{sub 3}/p-Si was fabricated by using atomic layer deposition and rf-magnetron sputtering techniques, and its microstructure has been investigated by using the high resolution transmission electron microscopy (HRTEM). By measuring the applied gate voltage dependence of the capacitance for the memory structure, the planar density of the trapped charges in Hf{sub 0.5}Zr{sub 0.5}O{sub 2} high-k film was estimated as 6.63 × 10{sup 12} cm{sup −2}, indicating a body defect density of larger than 2.21 × 10{sup 19} cm{sup −3}. It is observed that the post-annealing in N{sub 2} can reduces the defect density in Hf{sub 0.5}Zr{sub 0.5}O{sub 2} film, which was ascribed to the occupancy of oxygen vacancies by nitrogen atoms.

36 MATERIALS SCIENCE↗

Designing a boron nitride polyethylene composite for shielding neutrons

Neutrons are encountered in many different fields, including condensed matter physics, space exploration, nuclear power, and healthcare. Neutrons interacting with a biological target produce secondary charged particles that are damaging to human health. The most effective way to shield neutrons is to slow them to thermal energies and then capture the thermalized neutrons. These factors lead us to consider potential materials solutions for neutron shields that maximize the protection of humans while minimizing the shield mass and adapt well to modern additive manufacturing techniques. Using hexagonal boron nitride (hBN) as a capture medium and high-density polyethylene (HDPE) as a thermalization medium, we aim to design the optimal internal structure of h 10 BN/HDPE composites by minimizing the effective dose, which is a measure of the estimated radiation damage exposure for a human. Through Monte Carlo simulations in Geant4, we find that the optimal structure reduces the effective dose up to a factor of 72 over aluminum (Al) and up to a factor of 4 over HDPE; this is a significant improvement in shielding effectiveness that could dramatically reduce the radiation exposure of occupational workers.

36 MATERIALS SCIENCE↗