Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical Isolator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Fiberoptics technology and its application to propulsion control systems

Electro-optical systems have many advantages over conventional electrical systems. Among these are optics' insensitivity to electro-magnetic interference, good electrical isolation and the ability to make measurements in highly explosive areas without risk. These advantages promise to help improve the reliability of future aircraft engine control systems which will be entirely electronic digital. To improve the reliability of these systems, especially against lightning strikes, passive, optical, sensors and fiberoptic transmission lines are being considered for use in future engine systems. Also under consideration are actuators which receive their command signals over fiber optic cables. This paper reviews concepts used for optical instrumentation and actuation systems and discusses work being done by NASA Lewis Research Center in this area.

Baumbick, R. J.↗

Quantification of online removal of refractory black carbon using laser-induced incandescence in the single particle soot photometer

Refractory black carbon (rBC) is an aerosol that has important impacts on climate and human health. rBC is often mixed with other species, making it difficult to isolate and quantify its important effects on physical and optical properties of ambient aerosol. To solve this measurement challenge, a new method to remove rBC was developed using laser-induced incandescence (LII) by Levin et al. in 2014. Application of the method with the Single Particle Soot Photometer (SP2) is used to determine the effects of rBC on ice nucleating particles (INP). Here, we quantify the efficacy of the method in the laboratory using the rBC surrogate Aquadag. Polydisperse and mobility-selected samples (100–500 nm diameter, 0.44–36.05 fg), are quantified by a second SP2. Removal rates are reported by mass and number. For the mobility-selected samples, the average percentages removed by mass and number of the original size are 88.9 ± 18.6% and 87.3 ± 21.9%, respectively. Removal of Aquadag is efficient for particles >100 nm mass-equivalent diameter (d me ), enabling application for microphysical studies. However, the removal of particles ≤100 nm d me is less efficient. Absorption and scattering measurements are reported to assess its use to isolate brown carbon (BrC) absorption. Scattering removal rates for the mobility-selected samples are >90% on average, yet absorption rates are 53% on average across all wavelengths. Therefore, application to isolate effects of microphysical properties determined by larger sizes is promising, but will be challenging for optical properties. Lastly, the results reported also have implications for other instruments employing internal LII, e.g., the Soot Particle Aerosol Mass Spectrometer (SP-AMS).

54 ENVIRONMENTAL SCIENCES↗

(Almost) Dark Galaxies in the ALFALFA Survey: Isolated H i-bearing Ultra-diffuse Galaxies

Here, we present a sample of 115 very low optical surface brightness, highly extended, H i-rich galaxies carefully selected from the ALFALFA survey that have similar optical absolute magnitudes, surface brightnesses, and radii to recently discovered "ultra-diffuse" galaxies (UDGs). However, these systems are bluer and have more irregular morphologies than other UDGs, are isolated, and contain significant reservoirs of H i. We find that while these sources have normal star formation rates for H i-selected galaxies of similar stellar mass, they have very low star formation efficiencies. We further present deep optical and H i-synthesis follow-up imaging of three of these H i-bearing ultra-diffuse sources. We measure H i diameters extending to ~40 kpc, but note that while all three sources have large H i diameters for their stellar mass, they are consistent with the H i mass–H i radius relation. We further analyze the H i velocity widths and rotation velocities for the unresolved and resolved sources, respectively, and find that the sources appear to inhabit halos of dwarf galaxies. Finally, we estimate spin parameters, and suggest that these sources may exist in high spin parameter halos, and as such may be potential H i-rich progenitors to the ultra-diffuse galaxies observed in cluster environments.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental upper limit on the estimated thermal noise at low frequencies in a gravitational wave detector

The mirror relative motion of a suspended Fabry-Perot cavity is studied in the frequency range 3-100 Hz. The experimental measurements presented in this paper have been performed at the Low Frequency Facility, a high finesse optical cavity 1 cm long suspended to a mechanical seismic isolation system like the one of the VIRGO gravitational wave antenna. Because of the radiation pressure between the two mirrors of the cavity, the dynamic behavior of the system is characterized by the optical spring stiffness. In the frequency region above 3 Hz, where seismic noise contamination is negligible, the mirror displacement noise is stationary and its statistical distribution is Gaussian. Using a simplified mechanical model of the suspended system and applying the fluctuation dissipation theorem, we show that the measured power spectrum is reproduced in the frequency region 3-90 Hz. Since the contribution coming from different sources of the system to the total noise budget turns out to be negligible, we conclude that the relative displacement power spectrum of this opto-mechanical system is compatible with a system at thermal equilibrium within its environment. In the region 3-10 Hz this measurement gives so far the best upper limit for the thermal noise of the suspension for a gravitational wave interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The optical nature of methylsuccinic acid in human urine

Methylsuccinic acid was isolated from human urine, derivatized as the di-S-(+)-2-butyl ester, and analyzed using a gas chromatographic system capable of separating the enantiomers of the derivative. The R-(+)-isomer was found to be present. Methylsuccinic acid is potentially important as a criterion for abiogenicity, having been obtained as a racemic mixture from sources known to be abiotic.

Zeitman, B.↗

Photoinduced anisotropic lattice dynamic response and domain formation in thermoelectric SnSe

Identifying and understanding the mechanisms behind strong phonon–phonon scattering in condensed matter systems is critical to maximizing the efficiency of thermoelectric devices. To date, the leading method to address this has been to meticulously survey the full phonon dispersion of the material in order to isolate modes with anomalously large linewidth and temperature-dependence. Here we combine quantitative MeV ultrafast electron diffraction (UED) analysis with Monte Carlo based dynamic diffraction simulation and first-principles calculations to directly unveil the soft, anharmonic lattice distortions of model thermoelectric material SnSe. A small single-crystal sample is photoexcited with ultrafast optical pulses and the soft, anharmonic lattice distortions are isolated using MeV-UED as those associated with long relaxation time and large displacements. We reveal that these modes have interlayer shear strain character, induced mainly by c -axis atomic displacements, resulting in domain formation in the transient state. These findings provide an innovative approach to identify mechanisms for ultralow and anisotropic thermal conductivity and a promising route to optimizing thermoelectric devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The JPL Phase B interferometer testbed

Future NASA missions with large optical systems will require alignment stability at the nanometer level. However, design studies indicate that vibration resulting from on-board disturbances can cause jitter at levels three to four orders of magnitude greater than this. Feasibility studies have shown that a combination of three distinct control layers will be required for these missions, including disturbance isolation, active and passive structural vibration suppression, and active optical pathlength compensation. The CSI technology challenge is to develop these design and control approaches that can reduce vibrations in the optical train by a factor of 1000 to 10,000. The focus of the paper is on describing the Phase B Testbed structure and facility, as the experimental results are included in other papers presented at this same conference.

Eldred, Daniel B.↗

Machine Vision for High Precision Volume Measurement Applied to Levitated Containerless Materials Processing

By combining the best practices in optical dilatometry with new numerical methods, a high-speed and high precision technique has been developed to measure volume of levitated, containerlessly processed samples with sub- pixel resolution. Containerless processing provides the ability to study highly reactive materials without the possibility of contamination affecting thermo-physical properties. Levitation is a common technique used to isolate a sample as it is being processed. Noncontact optical measurement of thermo-ophysical properties is very important as traditional measuring methods cannot be used. Modern, digitally recorded images require advanced numerical routines to recover the sub-pixel locations of sample edges and, in turn produce high precision measurements.

Bradshaw, R. C.↗

Rare isotope-containing diamond colour centres for fundamental symmetry tests

Detecting a non-zero electric dipole moment in a particle would unambiguously signify physics beyond the Standard Model. A potential pathway towards this is the detection of a nuclear Schiff moment, the magnitude of which is enhanced by the presence of nuclear octupole deformation. However, due to the low production rate of isotopes featuring such ‘pear-shaped’ nuclei, capturing, detecting and manipulating them efficiently is a crucial prerequisite. Incorporating them into synthetic diamond optical crystals can produce defects with defined, molecule-like structures and isolated electronic states within the diamond band gap, increasing capture efficiency, enabling repeated probing of even a single atom and producing narrow optical linewidths. In this study, we used density functional theory to investigate the formation, structure and electronic properties of crystal defects in diamond containing 229 ⁢Pa, a rare isotope that is predicted to have an exceptionally strong nuclear octupole deformation. In addition, we identified and studied stable lanthanide-containing defects with similar electronic structures as non-radioactive proxies to aid in experimental methods. Our findings hold promise for the existence of such defects and can contribute to the development of a quantum information processing-inspired toolbox of techniques for studying rare isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Optical control of charged exciton states in tungsten disulfide

A method is presented for optically preparing WS{sub 2} monolayers to luminescence from only the charged exciton (trion) state–completely suppressing the neutral exciton. When isolating the trion state, we observed changes in the Raman A{sub 1g} intensity and an enhanced feature on the low energy side of the E{sup 1}{sub 2g} peak. Photoluminescence and optical reflectivity measurements confirm the existence of the prepared trion state. This technique also prepares intermediate regimes with controlled luminescence amplitudes of the neutral and charged exciton. This effect is reversible by exposing the sample to air, indicating the change is mitigated by surface interactions with the ambient environment. This method provides a tool to modify optical emission energy and to isolate physical processes in this and other two-dimensional materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Decoding the star forming properties of gas-rich galaxy pairs

Here we extend the analysis of Bok et al. (2020) in which the H i content of isolated galaxies from the AMIGA (Analysis of the interstellar Medium in Isolated GAlaxies) sample and selected paired galaxies from ALFALFA (Arecibo Legacy Fast ALFA) were examined as a potential driver of galaxy location on the WISE (Wide-field Infrared Survey Explorer) mid-infrared SFR–M * sequence. By further characterizing the isolated and pair galaxy samples, i.e. in terms of optical galaxy morphology, a more detailed and quantitative description of local galaxy environment by way of the local number density (η) and tidal strength (Q) parameters, star formation efficiency (SFE HI ), and H i integrated profile asymmetries, we present plausible pathways for the broadening of the pair sample H i deficiency distribution towards both high and low deficiencies compared to the narrower isolated galaxy sample distribution (i.e. σ PAIRS = 0.34 versus σ AMIGA = 0.28). We associate the gas-rich tail of the pair deficiency distribution with the highest Q values, large profile asymmetries, and low SFEs. From this, we infer that merger activity is enhancing gas supplies, as well as disrupting the efficiency of star formation, via strong gravitational torques. The gas-poor wing of the deficiency distribution appears to be populated with galaxies in denser environments (with larger η values on average), more akin to groups. Despite our gas-rich selection criterion, there is a small population of early-type galaxies in the pair sample, which primarily fall in the positive deficiency wing of the distribution. These results suggest that a combination of a denser galaxy environment, early-type morphology, and higher stellar mass is contributing to the broadening of the deficiency distribution towards larger deficiencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Power over fiber development for HEP detectors

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground and electromagnetic isolation is critical. In cryogenic environments, PoF offers a reliable power transmission technology, leveraging optical fibers to transfer power with minimal system degradation. PoF technology excels in maintaining low noise levels and isolation when delivering power to sensitive electronic systems operating in extreme temperature ranges and high voltage environments. Here, in a novel application of PoF for a HEP detector, power is provided to photon detector modules located on a surface at ~300 kV with respect to ground in the planned DUNE experiment. This summary paper of the PoF talk at the 16th PISA Meeting on Advanced Detectors highlights the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications offering a dependable solution with low noise, optimal efficiency, and superior isolation. The DUNE (Abi et al., 2020) experiment will soon deploy large liquid argon (LAr) time projection chambers (TPC) to detect neutrino interactions and other particle physics phenomena. In addition to the particle tracking provided by the TPC, photon detectors, powered by a first ever PoF system, in the cryostat will leverage the high scintillation light yield of LAr to provide crucial timing and additional calorimetric information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pointing Control System Design and Performance Evaluation for TPF Coronagraph

The Terrestrial Planet Finder (TPF) program aims to detect and characterize extra-solar Earth-like planets. The coronagraph telescope is one of the four mission concepts being studied. In order to reject the star flux and detect the planet flux in the visible light range, the coronagraph telescope must achieve a rejection ratio on the order of a billion to one. Dynamic jitter, introduced by environmental and on-board mechanical disturbances, degrades the optical performance, as characterized primarily by contrast ratio. The feasibility of using passive vibration isolation combined with active attitude and line-of- sight control systems to stabilize the spacecraft and the optical components to the requisite level is being studied. The telescope is also required to slew between targets. The slew mode control law must be designed to balance the need for efficient large-angle maneuvers while simultaneously avoiding the excitation of flexible modes in order to minimize settling time.

Liu, Kuo-Chia↗

The New LOTIS Test Facility

The Large Optical Test and Integration Site (LOTIS) at the Lockheed Martin Space Systems Company in Sunnyvale, CA is designed for the verification and testing of optical systems. The facility consists of an 88 foot temperature stabilized vacuum chamber that also functions as a class 10k vertical flow cleanroom. Many problems were encountered in the design and construction phases. The industry capability to build large chambers is very weak. Through many delays and extra engineering efforts, the final product is very good. With 11 Thermal Conditioning Units and precision RTD s, temperature is uniform and stable within 1oF, providing an ideal environment for precision optical testing. Within this chamber and atop an advanced micro-g vibration-isolation bench is the 6.5 meter diameter LOTIS Collimator and Scene Generator, LOTIS alignment and support equipment. The optical payloads are also placed on the vibration bench in the chamber for testing. This optical system is designed to operate in both air and vacuum, providing test imagery in an adaptable suite of visible/near infrared (VNIR) and midwave infrared (MWIR) point sources, and combined bandwidth visible-through-MWIR point sources, for testing of large aperture optical payloads. The heart of the system is the LOTIS Collimator, a 6.5m f/15 telescope, which projects scenes with wavefront errors <85 nm rms out to a 0.75 mrad field of view (FOV). Using field lenses, performance can be extended to a maximum field of view of 3.2 mrad. The LOTIS Collimator incorporates an extensive integrated wavefront sensing and control system to verify the performance of the system.

Bell, R. M.↗

Performance comparison of fiber optic tips in interferrometric displacement measurement

Fiber optic displacement sensors have many potential advantages over traditional displacement measurement techniques, including small size, immunity to electromagnetic interference, electrical isolation, and high resolution. In this report, we focus on an interferometric fiber optic sensor, where the gap between the fiber tip and the device under test forms a Fabry-Perot resonant cavity. An optical interrogator measures the reflected intensity at wavelengths ranging from 1510 to 1590 nm. The spacing between resonant frequencies allows us to determine the distance from the tip to the device under test. We consider ferrule connector angled physical contact (FC/APC), ferrule connector ultra physical contact (FC/UPC) and unpolished cleaved tips and compare their influence on sensor performance. A plane wave propagation model is proposed for predicting tip effects. Comparisons are made on the basis of sensor measurement range, resolution, and sensitivity to changes in test conditions. In this paper, we discuss the experimental setup, detail our analysis, and present test results with recommendations for the applications of each tip.

42 ENGINEERING↗

Performance comparison of fiber tips in interferometric displacement mesurements

Fiber optic displacement sensors have many potential advantages over traditional displacement measurement techniques, including small size, immunity to electromagnetic interference, electrical isolation, and high resolution. In this report, we focus on an interferometric fiber optic sensor, where the gap between the fiber tip and the device under test forms a Fabry-Perot resonant cavity. An optical interrogator measures the reflected intensity at wavelengths ranging from 1510 to 1590 nm. The spacing between resonant frequencies allows us to determine the distance from the tip to the device under test. We consider ferrule connector angled physical contact (FC/APC), ferrule connector ultra physical contact (FC/UPC) and unpolished cleaved tips and compare their influence on sensor performance. A plane wave propagation model is proposed for predicting tip effects. Comparisons are made on the basis of sensor measurement range, resolution, and sensitivity to changes in test conditions. In this paper, we discuss the experimental setup, detail our analysis, and present test results with recommendations for the applications of each tip.

42 ENGINEERING↗

Analysis and testing of a soft actuation system for segmented reflector articulation and isolation

Segmented reflectors have been proposed for space-based applications such as optical communication and large-diameter telescopes. An actuation system for mirrors in a space-based segmented mirror array has been developed as part of the National Aeronautics and Space Administration-sponsored Precision Segmented Reflector program. The actuation system, called the Articulated Panel Module (APM), articulates a mirror panel in 3 degrees of freedom in the submicron regime, isolates the panel from structural motion, and simplifies space assembly of the mirrors to the reflector backup truss. A breadboard of the APM has been built and is described. Three-axis modeling, analysis, and testing of the breadboard is discussed.

Jandura, Louise↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗