Search NASA⌕ Search

SEARCH · Search NASA

Results for “PDMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

System of fabricating a flexible electrode array

An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

Krulevitch, Peter↗

Microfluidic Platforms for on-chip Formulation and Small-Angle x-ray Analysis of the Phase Behavior of Lipid/Water Mixtures

We present a microfluidic platform for on-chip formulation and X-ray analysis of lipidic mesophases formed upon mixing lipids and water. The platform is designed to study the effect of detergents on the phase behavior of lipid/water mixtures. The platform allows automated preparation of multiple samples of different composition from stock solutions and subsequent on-chip small-angle X-ray diffraction (SAXS) data collection. To ensure X-ray transparency of the platform we used thin layers of cyclic olefin copolymer (COC) and PDMS. The viability of the platform is demonstrated by mapping out a section of the phase diagram for lipid monoolein mixed with solutions of detergent {beta}-octylglucoside. The platform reported here is a viable alternative to the traditional method of establishing phase diagrams for lipid/solution mixtures. Compared to the conventional approach, a significantly smaller amount of sample is required for mapping phase diagrams of lipidic mesophases and samples of various compositions are prepared automatically. In ongoing work we are using these chips to rapidly determine the phase behavior of a range of lipids to establish their suitability for membrane protein crystallization, especially with respect to their sensitivity to detergent concentration.

59 BASIC BIOLOGICAL SCIENCES↗

Conductive porous scaffolds as potential neural interface materials.

Our overall intent is to develop improved prosthetic devices with the use of nerve interfaces through which transected nerves may grow, such that small groups of nerve fibers come into close contact with electrode sites, each of which is connected to electronics external to the interface. These interfaces must be physically structured to allow nerve fibers to grow through them, either by being porous or by including specific channels for the axons. They must be mechanically compatible with nerves such that they promote growth and do not harm the nervous system, and biocompatible to promote nerve fiber growth and to allow close integration with biological tissue. They must exhibit selective and structured conductivity to allow the connection of electrode sites with external circuitry, and electrical properties must be tuned to enable the transmission of neural signals. Finally, the interfaces must be capable of being physically connected to external circuitry, e.g. through attached wires. We have utilized electrospinning as a tool to create conductive, porous networks of non-woven biocompatible fibers in order to meet the materials requirements for the neural interface. The biocompatible fibers were based on the known biocompatible material poly(dimethyl siloxane) (PDMS) as well as a newer biomaterial developed in our laboratories, poly(butylene fumarate) (PBF). Both of the polymers cannot be electrospun using conventional electrospinning techniques due to their low glass transition temperatures, so in situ crosslinking methodologies were developed to facilitate micro- and nano-fiber formation during electrospinning. The conductivity of the electrospun fiber mats was controlled by controlling the loading with multi-walled carbon nanotubes (MWNTs). Fabrication, electrical and materials characterization will be discussed along with initial in vivo experimental results.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

System of fabricating a flexible electrode array

An image is captured or otherwise converted into a signal in an artificial vision system. The signal is transmitted to the retina utilizing an implant. The implant consists of a polymer substrate made of a compliant material such as poly(dimethylsiloxane) or PDMS. The polymer substrate is conformable to the shape of the retina. Electrodes and conductive leads are embedded in the polymer substrate. The conductive leads and the electrodes transmit the signal representing the image to the cells in the retina. The signal representing the image stimulates cells in the retina.

60 APPLIED LIFE SCIENCES↗

Robust Extraction Interface for Coupling Droplet-Based and Continuous Flow Microfluidics

Reliable and highly efficient extraction of droplets from oil to aqueous phase is key for downstream coupling with chemical separations and nonoptical detection methods such as amperometry and mass spectrometry. This paper presents an improved interface providing robust extraction for droplet-based poly(dimethylsiloxane) (PDMS) microfluidic devices. The extraction interface consists of an array of cylindrical posts with narrow apertures in between. The aqueous flow channel into which droplets coalesced was simply and selectively modified to be hydrophilic, while the continuous oil phase flow channel that contained encapsulated aqueous droplets retained a hydrophobic surface. The different surfaces on both sides of the extraction region form a highly stable liquid interface between the two immiscible phases, allowing rapid droplet transfer to the aqueous stream. Entire droplets could be completely extracted within broad ranges of aqueous and oil flow rates (0 - 1 and 0.1 - 1 uL/min, respectively). After extraction, the droplet contents could be transported electrophoretically or by pressure-driven flow to a monolithically integrated emitter for nano-electrospray ionization mass spectrometry (nanoESI-MS) analysis. This interface should be amenable to the separation and identification of droplet contents and on-line monitoring of in-droplet reactions.

Based↗

Semiconductor light-emitting devices having concave microstructures providing improved light extraction efficiency and method for producing same

A conventional semiconductor LED is modified to include a microlens layer over its light-emitting surface. The LED may have an active layer including at least one quantum well layer of InGaN and GaN. The microlens layer includes a plurality of concave microstructures that cause light rays emanating from the LED to diffuse outwardly, leading to an increase in the light extraction efficiency of the LED. The concave microstructures may be arranged in a substantially uniform array, such as a close-packed hexagonal array. The microlens layer is preferably constructed of curable material, such as polydimethylsiloxane (PDMS), and is formed by soft-lithography imprinting by contacting fluid material of the microlens layer with a template bearing a monolayer of homogeneous microsphere crystals, to cause concave impressions, and then curing the material to fix the concave microstructures in the microlens layer and provide relatively uniform surface roughness.

42 ENGINEERING↗

Photoplethysmography beyond perfusion and oxygenation monitoring: Pulse wave analysis for hepatic graft monitoring

Photoplethysmography is a widely used technique in monitoring perfusion and blood oxygen saturation by using the amplitude of the pulsatile signal on one or multiple wavelengths. However, the pulsatile signal carries in its waveform a substantial amount of information about the mechanical properties of the tissue and vasculature under investigation that is still yet to be utilized to its full potential. In this work, we present the feasibility of pulse wave analysis for the application of monitoring hepatic implants and diagnosing graft complications. In particular, we show the possibility of computing the slope of the pulse during the diastole phase to assess the location of vascular complications when they take place. This hypothesis was tested in a series of in vitro experiments using a PDMS based phantom mimicking the optical and mechanical properties of the portal vein. The emptying time of the vessel increased from 305 ms to 515 ms when an occlusion was induced downstream from the phantom. However, in the case of upstream occlusions, the emptying time remained constant. In both cases, a decrease in the amplitude of the pulse was recorded indicating the drop in flow levels. In addition, we show that quantifying the emptying time of the vasculature under investigation can be used to assess its compliance. The emptying time decreased from 305 ms for phantoms with compliance of 15 KPa to 195 ms for phantoms with compliance of 100 KPa. These compliance levels mimic those seen for normal and fibrotic hepatic tissue respectively.

oxygenation monitoring↗

PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

Environmental Molecular Sciences Laboratory↗

Mechanically stiff, electrically conductive composites of polymers and carbon nanotubes

Using SWNT-CA as scaffolds to fabricate stiff, highly conductive polymer (PDMS) composites. The SWNT-CA is immersing in a polymer resin to produce a SWNT-CA infiltrated with a polymer resin. The SWNT-CA infiltrated with a polymer resin is cured to produce the stiff and electrically conductive composite of carbon nanotube aerogel and polymer.

36 MATERIALS SCIENCE↗

Mechanically stiff, electrically conductive composites of polymers and carbon nanotubes

Using SWNT-CA as scaffolds to fabricate stiff, highly conductive polymer (PDMS) composites. The SWNT-CA is immersing in a polymer resin to produce a SWNT-CA infiltrated with a polymer resin. The SWNT-CA infiltrated with a polymer resin is cured to produce the stiff and electrically conductive composite of carbon nanotube aerogel and polymer.

36 MATERIALS SCIENCE↗

Towards functional assembly of 3D and 2D nanomaterials

Functional assemblies of materials can be realized by tuning the work function and band gap of nanomaterials by rational material selection and design. Here we demonstrate the structural assembly of 2D and 3D nanomaterials and show that layering a 2D material monolayer on a 3D metal oxide leads to substantial alteration of both the surface potential and optical properties of the 3D material. A 40 nm thick film of polycrystalline NiO was produced by room temperature rf-sputtering, resulting in a 3D nanoparticle assembly. Chemical vapor deposition (CVD) grown 10-30 μm WS2 flakes (2D material) were placed on the NiO surface using a PDMS stamp transfer technique. The 2D/3D WS2/NiO assembly was characterized using confocal micro Raman spectroscopy to evaluate the vibrational properties and using Kelvin probe force microscopy (KPFM) to evaluate the surface potential. Raman maps of the 2D/3D assembly show spatial non-uniformity of the A1g mode (~418 cm-1) and the disorder-enhanced longitudinal acoustic mode, 2LA(M) (~350 cm-1), suggesting that the WS2 exists in a strained condition on when transferred onto 3D polycrystalline NiO. KPFM measurements show that single layer WS2 on SiO2 has a surface potential 75 mV lower than that of SiO2, whereas the surface potential of WS2 on NiO is 15 mV higher than NiO, indicating that WS2 could act as electron donor or acceptor depending on the 3D material it is interfaced with. Thus 2D and 3D materials can be organized into functional assemblies with electron flow controlled by the WS2 either as the electron donor or acceptor.

Jacobs, Christopher B.↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

36 MATERIALS SCIENCE↗

Super-stretchable self-healing polymer

An elastic composition comprising the following structure: wherein: PDMS is polydimethylsiloxane having at least 5 dimethylsiloxane units; L is a bond or hydrocarbon linker; the asterisk (*) in A units denotes a connection point with an asterisk in B units, and at least one of the following linkages connect between connection points: r is an integer of at least 3; R is a hydrocarbon or siloxane-containing linking moiety; the composition includes a multiplicity of A units and multiplicity of B units; and a portion of the connection points are necessarily terminated by endcapping groups, wherein at least a portion of the endcapping groups are selected from the following structures: The invention also includes methods for making and using the above-described elastic composition.

Saito, Tomonori↗

Volumetric micro-injector for capillary electrophoresis

A volumetric microfluidic injector for capillary electrophoresis (CE) for highly repeatable sample injection has been designed and built to eliminate known injection bias in hydrodynamic injection. A defined volume from 1-10 nL or 0.1-100 nL of sample is confined in a defined region of a micro-valve PDMS microfluidic injector chip and electrophoretic potential is applied to drive sample into a separation device such as an embedded fused silica capillary for separation and detection. Using a 75 μm ID capillary, the RSD of an absorbance peak area as low as 1.32% (n=11) is obtained. As a comparison, the time-dependent injection was tested using the same chip which resulted in an inferior repeatability.

Ha, Noel Seunghyun↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

Addleman, Raymond S.↗

PREPARATION OF CLAY-COATED GLASS SURFACES FOR MICROFLUIDICS-BASED STUDY ON CLAY-FLUID INTERACTIONS

Unique characteristics of clay, even though make any clay abundant shales a good source of adsorbed gas, make them equally difficult to produce. The clay-water interaction can cause significant swelling and fines migration in the shale formation, both of which can significantly impair the overall hydrocarbon recovery from shale. Geomaterial micromodels, developed by functionalizing traditional glass or PDMS surface with geomaterials (e.g., calcite, quartz, clay) can represent the physico-chemical properties of the natural porous media and have been used during the last few years to understand and evaluate the solid-fluid physicochemical interactions. This study focuses on developing a clay-coated geomaterial surface and investigates the effect of base fluid's salinity on clay adsorption to the glass surface. Glass capillary tubes and straight channel borosilicate glass micromodels are coated with Illite clay minerals to represent the pore-scale clay chemistry of Caney Shale, a Mississippian unconventional play in Southern Oklahoma, USA. 10 wt.% of Illite clay slurries made with brines of four different salinities are used to coat the glass-capillary tubes to understand the effect of salinity in clay adsorption on the glass surface and overall coating quality. To achieve a stable coating and evaluate the impact of heat treatment on coating's stability, straight channel glass flow cells coated with Illite clay are heat-treated at low (25 °C) and high temperature (125 °C). Dynamic flooding tests were carried out with brines on the coated surface to evaluate the stability of the coating. The experiments' outcome indicated a strong relationship between the brine's salinity and the adsorption of clay particles on the glass surface. An increase in brine concentration resulted in improved adsorption of clay particles on the glass surface. Experiments involving heat treating the glass surface following the coating demonstrated significant improvement in the stability of the coating.

02 PETROLEUM↗

Effect of meta-carborane on segmental dynamics in a bimodal Poly(dimethylsiloxane) network

Bimodal networks of polydimethylsiloxane (PDMS) filled with varying amounts of icosahedral meta-carborane (m-CB) have been developed and characterized by broadband dielectric spectroscopy (BDS) and static {sup 1}H Multiple Quantum Nuclear Magnetic Resonance (MQ NMR). Both BDS and MQ NMR showed evidence for a decrease in the polymer chain dynamics. BDS spectra quantified a normal-mode relaxation near 40 Hz at 40 C. The frequency maximum observed for filled samples decreased with increasing m-CB content until contents greater than 5 wt. %. The width of the relaxation spectrum increased with the addition of small quantities of filler and decreased with filler contents greater that 5 wt. %. Agglomeration effects were observed at loadings greater than 5 wt % as manifest by the onset of low frequency Maxwell-Wagner-Sillars (MWS) processes. The MQ NMR data allowed the characterization of distributions of the residual dipolar couplings, <{Omega}{sub d}> and thus in the dynamic order parameter, Sb, consistent with the bimodal network architecture expected from the synthesis protocol used. Upon addition of less than 10 wt.% m-CB filler, the mean <{Omega}{sub d}> for the longer chains increased by 46% and the width of the distribution increased by 33%. The mean <{Omega}{sub d}> for the shorter chains increased by much less, indicative of preferential dispersion of the filler particles in the long chain domains of the network structure. We conclude that the mechanism of reinforcement is likely a free volume space filling at low loadings transitioning to complex molecular filler and polymer chain interaction phenomena at higher loadings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗