Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERFORMANCE CHARACTERISTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Electrical and Optical Performance Characteristics of 0.74-eV p/n InGaAs Monolithic Interconnected Modules

There has been a traditional trade-off in thermophotovoltaic (TPV) energy conversion development between system efficiency and power density. This trade-off originates from the use of front surface spectral controls such as selective emitters and various types of filters. A monolithic interconnected module (MIM) structure has been developed which allows for both high power densities and high system efficiencies. The MIM device consists of many individual indium gallium arsenide (InGaAs) cells series-connected on a single semi-insulating indium phosphide (InP) substrate. The MIM is exposed to the entire emitter output, thereby maximizing output power density. An infrared (IR) reflector placed on the rear surface of the substrate returns the unused portion of the emitter output spectrum back to the emitter for recycling, thereby providing for high system efficiencies. Initial MIM development has focused on a 1 sq cm device consisting of eight (8) series interconnected cells. MIM devices, produced from 0.74-eV InGaAs, have demonstrated V(sub oc) = 3.2 volts, J(sub sc) = 70 mA/sq cm, and a fill factor of 66% under flashlamp testing. Infrared (IR) reflectance measurements (greater than 2 micron) of these devices indicate a reflectivity of greater than 82%. MIM devices produced from 0.55-eV InGaAs have also been demonstrated. In addition, conventional p/n InGaAs devices with record efficiencies (11.7% AM0) have been demonstrated.

Wilt, David M.↗

Electrical and Optical Performance Characteristics of p/n InGaAs Monolithic Interconnected Modules

There has been a traditional trade-off in ThermoPhotoVoltaic (TPV) energy conversion development between system efficiency and power density. This trade-off originates from the use of front surface spectral controls such as selective emitters and various types of filters. A Monolithic Interconnected Module (MIM) structure has been developed which allows for both high power densities and high system efficiencies. The MIM device consists of many individual Indium Gallium Arsenide (InGaAs) devices series-connected on a single semi-insulating Indium Phosphide (InP) substrate. The MIMs are exposed to the entire emitter output, thereby maximizing output power density. An InfraRed (IR) reflector placed on the rear surface of the substrate returns the unused portion of the emitter output spectrum back to the emitter for recycling, thereby providing for high system efficiencies. Initial MIM development has focused on a 1 sq cm device consisting of eight (8) series interconnected cells. MIM devices, produced from 0.74eV InGaAs, have demonstrated V(sub infinity) = 3.2 volts, J(sub sc) = 70 mA/sq cm and a fill factor of 66% under flashlamp testing. IR reflectance measurements (greater than 2 microns) of these devices indicate a reflectivity of greater than 82%. MIM devices produced from 0.55 eV InGaAs have also been demonstrated. In addition, conventional p/n InGaAs devices with record efficiencies (11.7% AM0) have been demonstrated.

Wilt, David M.↗

Performance characteristics of narrow linewidth fiber laser pumped mid-IR difference frequency mixing light source for methane detection

A high-power, narrow-linewidth Yb fiber laser with a fiber Bragg grating (FBG) pumped difference frequency generation (DFG) in a periodically poled lithium niobate (PPLN) crystal was investigated in detail. A mid-IR power of approximately 2.3 microW at 3.3 micrometers with a slope efficiency of 0.85 mW/W2 was achieved. A Doppler-broadened absorption spectrum of CH4 at 3038.497 cm-1 (3.2911 micrometers) was obtained with a 0.1-m long-gas cell at a pressure of 133 Pa. The linewidth of the DFG source was evaluated to be less than 96 MHz from the observed spectral linewidth. Real-time monitoring of CH4 (approximately 1.78 ppm) in ambient air in a multipass cell which has an optical path length of 10 m was also demonstrated.

Non-NASA Center↗

Performance of J33-A-23 Turbojet-Engine Compressor: Over-All Performance Characteristics of Compressor with 17-Blade Impeller - Part 1

The production-model 333-A-23 turbojet-engine compressor with a 17-blade impeller was operated at ambient and 0 F inlet temperatures and at inlet pressures of 14 and 5 inches mercury absolute for equivalent impeller speeds from 6000 to 12,750 rpm. The results of this investigation are compared with those of the 533-A-21 compressor. At the design equivalent speed of 11,750 rpm the maximum pressure ratio was 4.39. This occurred at the surge point at which the equivalent weight flow was 80.8 pounds per second, ana the adiabatic temperature-rise efficiency was 0.757. The maximum flow at the design equivalent speed was 88.0 pounds per second. The maximum adiabatic temperature-rise efficiency of 0.799 was obtained at an equivalent speed of 10,000 rpm, and equivalent weight flow of 62.9 pounds per second, and a pressure ratio of 3.20. At the maximum equivalent speed investigated (12,750 rpm), a peak pressure ratio of 4.90 was attained at an equivalent weight flow of 85.4 pounds per second and an efficiency of 0.680.

Beede, William L.↗

Performance of J33-A-23 Turbojet-Engine Compressor: Over-All Performance Characteristics of Compressor with 34-Blade Impeller at Equivalent Impeller Speeds from 6000 to 11.750 RPM - II

The J33-A-23 compressor with a 34-blade impeller was operated at ambient inlet temperature and an inlet pressure of 14 inches mercury absolute over a range of equivalent impeller speeds from 6000 to 11,750 rpm. Additional runs at equivalent speeds of 7,000, 10,000, and 11,750 rpm and ambient inlet temperature were made at inlet pressures of 5 and 10 inches mercury absolute. The results of this investigation are compared with those of the J33-A-23 compressor with a 17-blade impeller. At the design equivalent speed of 11,750 rpm the 533-A-23 compressor with a 34-blade impeller had a peak pressure ratio of 4.49 at an equivalent weight flow of 82.4 pounds per second and an adiabatic temperature-rise efficiency of 0.740. The maximum equivalent flow at design speed was 91.8 pounds per second. The peak efficiency at design speed (0.757) occurred at an equivalent weight flow of 85.5 pounds per second. The maximum adiabatic temperature- rise efficiency of 0.773 was obtained at an equivalent impeller speed of 10,000 rpm, an equivalent weight flow of 65.8 pounds per second, and a pressure ratio of 3.27. At equivalent impeller speeds of.l0,000 and 11,75O rpm a decrease in inlet pressure resulted in a decrease in maximum equivalent weight flow, peak pressure ratio, and peak adiabatic temperature- rise efficiency.

Beede, William L.↗

Performance of Allison Model 400-C6 Turbojet-Engine Compressor: Over-All Performance Characteristics of Compressor at Equivalent Impeller Speeds of 6000, 7000, and 8500 RPM - I

The Allison model 400-C6 compressor was operated at an inlet pressure of 12 inches of mercury absolute ana ambient inlet temperature at equivalent impeller speeds of 6000, 7000, and 8500 rpm. Additional runs at an equivalent speed of 7000 rpm and ambient inlet temperature were made at inlet pressures from 7 to 22 inches of mercury absolute. The results of this investigation are compared with those of the 533-A-23 compressors. For the speeds investigated, the Allison model 400-C6 compressor had a maximum adiabatic temperature-rise efficiency of 0.768 at an equivalent speed of 7000 rpm; the corresponding equivalent weight flow was 45.0 pounds per second and the pressure ratio was 1.83. At an equivalent impeller speed of 8500 rpm, the maximum equivalent weight flow was 61.6 pounds per second and the peak pressure ratio of 2.38 occurred at an equivalent weight flow of 52.2 pounds per 1 second and an adiabatic temperature-rise efficiency of 0.714. At an equivalent speed of 7000 rpm, increasing the compressor- inlet pressure increased the maximum equivalent weight flow and the pressure ratio.

Kovach, Karl↗

Performance Characteristics of Lithium Ion Polymeric Electrolyte Cells

A series of polyacrylonitrile-based (PAN) electrolytes containing LiAsF6 and a number of solvent mixtures including ethylene carbonate (EC) + propylene carbonate (PC) were prepared, electrochemically evaluated and used as electrolyte in the polymer cells.

polyacrylonitrile-based electrolytes ethylene carb↗

Performance Characteristics of an Aircraft Engine with Exhaust Turbine Supercharger, Special Report

The Pratt and Whitney Aircraft company and the Naval Aircraft Factory of the United States Navy cooperated in a laboratory and flight program of tests on an exhaust turbine supercharger. Two series of dynamometer tests of the engine super-charger combination were completed under simulated altitude conditions. One series of hot gas-chamber tests was conducted by the manufacturer of the supercharger. Flight demonstrations of the supercharger installed in a twin-engine flying boat were terminated by failure of the turbine wheels. The analysis of the results indicated that a two-stage supercharger with the first-stage exhaust turbine driven will deliver rated power for a given indicated power to a higher altitude, will operate more efficiently, and will require simpler controls than a similar engine with the first stage of the supercharger driven from the crankshaft through multispeed gears.

Lester, E. M.↗

Evaluation of the Performance Characteristics of CGLSS II and U.S. NLDN Using Ground-Truth Data from Launch Complex 398, Kennedy Space Center, Florida

A new comprehensive lightning instrumentation system has been designed for Launch Complex 39B (LC39B) at the Kennedy Space Center, Florida. This new instrumentation system includes six synchronized high-speed video cameras, current sensors installed on the nine downcouductors of the new lightning protection system (LPS) for LC39B; four dH/dt, 3-axis measurement stations; and five dE/dt stations composed of two antennas each. The LPS received 8 direct lightning strikes (a total of 19 strokes) from March 31 through December 31, 2011. The measured peak currents and locations are compared to those reported by the CGLSS 11 and the NLDN. Results of comparison are presented and analyzed in this paper.

Mata, Carlos T.↗

Evaluation of the Performance Characteristics of CGLSS II and U.S. NLDN Using Ground-Truth Dalta from Launch Complex 398, Kennedy Space Center, Florida

A new comprehensive lightning instrumentation system has been designed for Launch Complex 39B (LC39B) at the Kennedy Space Center, Florida. This new instrumentation system includes seven synchronized high-speed video cameras, current sensors installed on the nine downconductors of the new lightning protection system (LPS) for LC39B; four dH/dt, 3-axis measurement stations; and five dE/dt stations composed of two antennas each. The LPS received 8 direct lightning strikes (a total of 19 strokes) from March 31 through December 31 2011. The measured peak currents and locations are compared to those reported by the Cloud-to-Ground Lightning Surveillance System (CGLSS II) and the National Lightning Detection Network (NLDN). Results of comparison are presented and analyzed in this paper.

Mata, C. T.↗

Evaluation of the Performance Characteristics of the CGLSS and NLDN Systems Based on Two Years of Ground-Truth Data from Launch Complex 39B, Kennedy Space Center, Florida

From May 2011 through July 2013, the lightning instrumentation at Launch Complex 39B (LC39B) at the Kennedy Space Center, Florida, has obtained high-speed video records and field change waveforms (dE/dt and three-axis dH/dt) for 54 negative polarity return strokes whose strike termination locations and times are known with accuracy of the order of 10 m or less and 1 μs, respectively. A total of 18 strokes terminated directly to the LC39B lighting protection system (LPS), which contains three 181 m towers in a triangular configuration, an overhead catenary wire system on insulating masts, and nine down conductors. An additional 9 strokes terminated on the 106 m lightning protection mast of Launch Complex 39A (LC39A), which is located about 2.7 km southeast of LC39B. The remaining 27 return strokes struck either on the ground or attached to low-elevation grounded objects within about 500 m of the LC39B LPS. Leader/return stroke sequences were imaged at 3200 frames/sec by a network of six Phantom V310 high-speed video cameras. Each of the three towers on LC39B had two high-speed cameras installed at the 147 m level with overlapping fields of view of the center of the pad. The locations of the strike points of 54 return strokes have been compared to time-correlated reports of the Cloud-to-Ground Lightning Surveillance System (CGLSS) and the National Lightning Detection Network (NLDN), and the results of this comparison will be presented and discussed.

Waveforms↗