Search NASA⌕ Search

SEARCH · Search NASA

Results for “PERSONAL COMPUTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Utilizing machine learning to improve the precision of fluorescence imaging of cavity-generated spin squeezed states

We present a supervised learning model to calibrate the photon collection rate during the fluorescence imaging of cold atoms. The linear regression model finds the collection rate at each location on the sensor such that the atomic population difference equals that of a highly precise optical cavity measurement. This 192 variable regression results in a measurement variance 27% smaller than our previous single variable regression calibration. The measurement variance is now in agreement with the theoretical limit due to other known noise sources. This model efficiently trains in less than a minute on a standard personal computer's CPU and requires less than 10 min of data collection. Furthermore, the model is applicable across a large change in population difference and across data collected on different days.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-479: Estimation of the Accuracy in Respiratory-Gated Radiotherapy

Purpose: Irregular respiratory patterns affects dose outputs in respiratorygated radiotherapy and there is no commercially available quality assurance (QA) system for it. We designed and developed a patient specific QA system for respiratory-gated radiotherapy to estimate irradiated output. Methods: Our in-house QA system for gating was composed of a personal computer with the USB-FSIO electronic circuit connecting to the linear accelerator (ONCOR-K, Toshiba Medical Systems). The linac implements a respiratory gating system (AZ-733V, Anzai Medical). During the beam was on, 4.2 V square-wave pulses were continually sent to the system. Our system can receive and count the pulses. At first, our system and an oscilloscope were compared to check the performance of our system. Next, basic estimation models were generated when ionization-chamber measurements were performed in gating using regular sinusoidal wave patterns (2.0, 2.5, 4.0, 8.0, 15 sec/cycle). During gated irradiation with the regular patterns, the number of the pulses per one gating window was measured using our system. Correlation between the number of the pulses per one gating and dose per the gating window were assessed to generate the estimation model. Finally, two irregular respiratory patterns were created and the accuracy of the estimation was evaluated. Results: Compared to the oscilloscope, our system worked similarly. The basic models were generated with the accuracy within 0.1%. The results of the gated irradiations with two irregular respiratory patterns show good agreement within 0.4% estimation accuracy. Conclusion: Our developed system shows good estimation for even irregular respiration patterns. The system would be a useful tool to verify the output for respiratory-gated radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-05: Application of a Feature-Based Tracking Algorithm to KV X-Ray Fluoroscopic Images Toward Marker-Less Real-Time Tumor Tracking

Purpose: To detect target position on kV X-ray fluoroscopic images using a feature-based tracking algorithm, Accelerated-KAZE (AKAZE), for markerless real-time tumor tracking (RTTT). Methods: Twelve lung cancer patients treated with RTTT on the Vero4DRT (Mitsubishi Heavy Industries, Japan, and Brainlab AG, Feldkirchen, Germany) were enrolled in this study. Respiratory tumor movement was greater than 10 mm. Three to five fiducial markers were implanted around the lung tumor transbronchially for each patient. Before beam delivery, external infrared (IR) markers and the fiducial markers were monitored for 20 to 40 s with the IR camera every 16.7 ms and with an orthogonal kV x-ray imaging subsystem every 80 or 160 ms, respectively. Target positions derived from the fiducial markers were determined on the orthogonal kV x-ray images, which were used as the ground truth in this study. Meanwhile, tracking positions were identified by AKAZE. Among a lot of feature points, AKAZE found high-quality feature points through sequential cross-check and distance-check between two consecutive images. Then, these 2D positional data were converted to the 3D positional data by a transformation matrix with a predefined calibration parameter. Root mean square error (RMSE) was calculated to evaluate the difference between 3D tracking and target positions. A total of 393 frames was analyzed. The experiment was conducted on a personal computer with 16 GB RAM, Intel Core i7-2600, 3.4 GHz processor. Results: Reproducibility of the target position during the same respiratory phase was 0.6 +/− 0.6 mm (range, 0.1–3.3 mm). Mean +/− SD of the RMSEs was 0.3 +/− 0.2 mm (range, 0.0–1.0 mm). Median computation time per frame was 179 msec (range, 154–247 msec). Conclusion: AKAZE successfully and quickly detected the target position on kV X-ray fluoroscopic images. Initial results indicate that the differences between 3D tracking and target position would be clinically acceptable.

60 APPLIED LIFE SCIENCES↗

Multilevel relaxation model for describing the Moessbauer spectra of nanoparticles in a magnetic field

A theory is developed for the Moessbauer absorption spectra of an ensemble of single-domain particles in a magnetic field. This theory is based on the generalization of a relaxation model with a quantummechanical description of the stationary states of a particle and on the formalism of Liouville operators for describing the hyperfine interaction for a hyperfine field changing in both the magnitude and direction for various stationary states. The general scheme of calculating relaxation Moessbauer spectra in terms of a standard stochastic approach is substantially optimized using operations with block matrices and a unique tridiagonalization of high-rank non-Hermitian matrices with a simple nonorthogonal transformation in the calculation procedure. The resulting model can easily be implemented on a personal computer. It considers the physical mechanisms of formation of a hyperfine structure in a spectrum of nanoparticles in a real situation and self-consistently describes the qualitative features of the nontrivial evolution of spectra with the temperature and the magnetic-field direction and strength, which has been detected in {sup 57}Fe nucleus experiments performed on magnetic nanoparticles for half a century.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Athena - Digital Twin and Infrastructure Model [SWR 20-106]

The software provides database access and analysis code for project ATHENA data. In particular, it provides (1) access to the AWS RDS database and (2) supporting code for analysis. Additionally, the software contains all the code related to modeling the Dallas-Fort Worth International Airport (DFW) curbside (CTA modeling) using SUMO simulator. It demonstrates how to install, run and derive useful data from SUMO simulations. We will describe the basic files needed to run a simulation and how those files are generated. The software also has code for generating simulations representing different traffic management policies for DFW and simulating those policies on personal computer or on NREL's Eagle supercomputer. The examples provided are a representation of the DFW airport for curbside dropoff and and pickup.

Severino, Joseph↗

GnuForPlot Graphics

Gnuforplot Graphics is a Fortran90 program designed to generate two and three dimensional plots of data on a personal computer. The program uses calls to the open source code Gnuplot to generate the plots. Two Fortran90 programs have been written to use the Gnuplot graphics capabilities. The first program, named Plotsetup.f90 reads data from output files created by either the Stadium or LeachXS/Orchestra modeling codes and saves the data in arrays for plotting. This program then calls Gnuforplot which takes the data array along with user specified parameters to set plot specifications and issues Gnuplot commands that generate the screen plots. The user can view the plots and optionally save copies in jpeg format.

Flach, GregoryP.↗

Simple strategy for the simulation of axially symmetric large-area metasurfaces

Metalenses are composed of nanostructures for focusing light and have been widely explored in many exciting applications. However, their expanding dimensions pose simulation challenges. We propose a method to simulate metalenses in a timely manner using vectorial wave and ray tracing models. We sample the metalens’s radial phase gradient and locally approximate the phase profile by a linear phase response. Each sampling point is modeled as a binary blazed grating, employing the chosen nanostructure, to build a transfer function set. The metalens transmission or reflection is then obtained by applying the corresponding transfer function to the incoming field on the regions surrounding each sampling point. Fourier optics is used to calculate the scattered fields under arbitrary illumination for the vectorial wave method, and a Monte Carlo algorithm is used in the ray tracing formalism. We validated our method against finite-difference time domain simulations at 632 nm, and we were able to simulate metalenses larger than 3000 wavelengths in diameter on a personal computer.

Martins, Augusto (ORCID:0000000295546481)↗

Nuclear Safety [Vol. 32, No. 4, October-December 1991]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 477 Report on the International Symposium on the Use of Probabilistic Safety Assessment for Operational Safety—PSA '91, S. Chakraborty and M. Khatib-Rahbar; 488 Good Relationships Are Pivotal in Nuclear Data Bases, A. S. Heger and B. V. Koen; 494 Technical Note: The Interagency Nuclear Safety Review Panel's Evaluation of the Ulysses Space Mission, J. A. Sholtis, Jr., D. A. Huff, L. B. Gray, N. P. Klug, and R. O. Winchester; ACCIDENT ANALYSIS: 502 The Severe Accident Analysis Program for the Savannah River Nuclear Production Reactors, M. L. Hyder; CONTROL AND INSTRUMENTATION: 511 A Framework for Selecting Suitable Control Technologies for Nuclear Power Plant Systems, R. A. Kisner; DESIGN FEATURES: 521 Containments for Gas-Cooled Power Reactors History and Status, P.W. Williams; ENVIRONMENTAL EFFECTS: 537 Indoor Radon: A Natural Risk, N. H. Harley and J.H. Harley; On the Importance of the Atmospheric Parameters in the Fission Products Distribution of a Severe Reactor Accident, M. C. Barla and A. R. Bayulken; Book Review: Health Effects of Exposure to Low Levels of Ionizing Radiation BEIR V, C. R. Richmond; WASTE AND SPENT FUEL MANAGEMENT: 555 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver OPERATING EXPERIENCES: 567 Effects of Component Aging on the Westhinghouse Control Rod Drive System, K. Sullivan and W. Gunther; 577 Reactor Shutdown Experience, Compiled by J. W. Cletcher, 580 Selected Safety-Related Events, Compiled by G. A. Murphy; 582 Operating U 8 Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver, RECENT DEVELOPMENTS: 596 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 610 Reports, Standards, and Safety Guides, D. S. Queener; 614 Proposed Rule Changes as of June 30, 1991; ANNOUNCEMENTS: 520 Workshop on PC PRAISE: A Probabilistic Fracture Mechanics Personal Computer Code for Nuclear Power Plant Piping Reliability Assessment; 536 Fifth Workshop on Nuclear Power Plant Containment Integrity; 624 New OECD "International Information System on Occupational Exposure (ISOE)"; 625 Harvard School of Public Health Announces Short Courses; 625 Eighth Power Plant Dynamics, Control and Testing Symposium; 626 Second Training Course on Off-Site Emergency Planning and Response for Nuclear Accidents; 618 The Authors; 622 Reviewers of Nuclear Safety, Vol 32.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

INL High Level Language Microcontroller Implementa

The overall goal of this project is to improve the security of embedded devices (microcontrollers) used in monitoring and control of energy-sector infrastructure. As these devices are essentially scaled-down personal computers (PCs), they are vulnerable to common low-level cyber-attacks such as buffer overflows and insecure authentication. The implementation of a modern high-level programming language on these microcontrollers would disallow such low-level attacks as the languages would have inherent safeguards against these types of cyber exploits. Idaho National Laboratory (INL) has partnered with Siemens Corporate Research (SCR) to develop and test a 4 th -generation language DNP3 implementation on real-world embedded hardware. These tests were carried out on control-system device models currently deployed in real-world applications. Testing was performed with existing C-based DNP implementation as well as the Python version developed by INL.

4GL↗

Development of HydroImage, A User Friendly Hydrogeophysical Characterization Software

HydroImage, user-friendly software that utilizes high-resolution geophysical data for estimating hydrogeological parameters in subsurface strata, was developed under this grant. HydroImage runs on the personal computer platform to promote broad use by hydrogeologists to further understanding of subsurface processes that govern contaminant fate, transport, and remediation. The unique software provides estimates of hydrogeological properties over continuous volumes of the subsurface, whereas previous approaches only allow estimation of point locations. Thus, this unique tool can be used to significantly enhance site conceptual models and improve design and operation of remediation systems.

54 ENVIRONMENTAL SCIENCES↗

Visual Sample Plan Version 7.0 User's Guide

User's guide for VSP 7.0 This user's guide describes Visual Sample Plan (VSP) Version 7.0 and provides instructions for using the software. VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to risk decisions have the required confidence and performance. VSP Version 7.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. It also provides data quality assessment and statistical analysis functions to support evaluation of the data and determine whether the data support decisions regarding sites suspected of contamination. The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (XP, Vista, Windows 7, and Windows 8). Designed primarily for project managers and users without expertise in statistics, VSP is applicable to two- and three-dimensional populations to be sampled (e.g., rooms and buildings, surface soil, a defined layer of subsurface soil, water bodies, and other similar applications) for studies of environmental quality. VSP is also applicable for designing sampling plans for assessing chem/rad/bio threat and hazard identification within rooms and buildings, and for designing geophysical surveys for unexploded ordnance (UXO) identification.

97 MATHEMATICS AND COMPUTING↗

Yields and Cavity Radii of Underground Nuclear Tests with Specified Yields Reported in DOE/NV -- 209-REV 15 (2000)

The letter report provides a compilation of yield and cavity radius information for all underground nuclear tests with specified yields reported in DOE/NV -- 209-REV 15 (2000). Yield data were taken directly from DON/NV -- 209-REV 15 (2000). Cavity radius information was taken from a personal computer based database resident at Lawrence Livermore National Laboratory. This database is associated with the written report by Miller et al. (2002).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Guide for 3D WARP simulations of hollow electron beam lenses. Practical explanation on basis of Tevatron electron lens test stand

The purpose of this guide is to help successive students handle WARP. It outlines the installation of WARP on personal computers as well as super-computers and clusters. It furthermore teaches the reader how to handle the WARP environment and run basic scripts. Lastly it outlines how to execute the current Hollow Electron Beam Lens scripts.

97 MATHEMATICS AND COMPUTING↗

Resonant Ultrasound Spectroscopy

New measurement techniques are central to the advancement of science. One emerging strategy, made possible today by the accessibility of powerful personal computers, is the development of instrumentation that requires massive computational power to produce otherwise unobtainable results. RUS is an example.

47 OTHER INSTRUMENTATION↗

Advanced Code for Photocathode Design

The Phase I activity demonstrated that PhotoQE could be upgraded and modified to allow input using a graphical user interface. Specific calls to platform-dependent (e.g. IMSL) function calls were removed, and Fortran77 components were rewritten for Fortran95 compliance. The subroutines, specifically the common block structures and shared data parameters, were reworked to allow the GUI to update material parameter data, and the system was targeted for desktop personal computer operation. The new structures overcomes the previous rigid and unmodifiable library structures by implementing new, materials library data sets and repositioning the library values to external files. Material data may originate from published literature or experimental measurements. Further optimization and restructuring would allow custom and specific emission models for beam codes that rely on parameterized photoemission algorithms. These would be based on simplified and parametric representations updated and extended from previous versions (e.g., Modified Fowler-Dubridge, Modified Three-Step, etc.).

43 PARTICLE ACCELERATORS↗

Marine ARM GPCI Investigation of Clouds Bridge Display Field Campaign Report

At the beginning of the U.S. Department of Energy (DOE) Marine Atmospheric Radiation Measurement (ARM) Climate Research Facility Global Energy and Water Experiment (GEWEX) Cloud System Study (GCSS) Pacific Cross-Section Intercomparison (GPCI) Investigation of Clouds (MAGIC) experiment, we recognized that the crew on the ship’s bridge would like to see a display of the meteorological data that was being collected. While a display on the bridge would be marginally useful to the science, it was decided to make a display for the bridge. A display was programmed in Lab View and a personal computer (PC) was set up in the bridge. This remained in operation until the ship went to dry dock for upgrades and service. Part of the upgrade was a new meteorological system for the ship. After this time there was no need for the ARM display and so it was not re-installed for the remainder of the program.

54 ENVIRONMENTAL SCIENCES↗

Multi-Angle Snowflake Camera Value-Added Product

The Multi-Angle Snowflake Camera (MASC) addresses a need for high-resolution multi-angle imaging of hydrometeors in freefall with simultaneous measurement of fallspeed. As illustrated in Figure 1, the MASC consists of three cameras, separated by 36°, each pointing at an identical focal point approximately 10 cm away. Located immediately above each camera, a light aims directly at the center of depth of field for its corresponding camera. The focal point at which the cameras are aimed lies within a ring through which hydrometeors fall. The ring houses a system of near-infrared emitter-detector pairs, arranged in two arrays separated vertically by 32 mm. When hydrometeors pass through the lower array, they simultaneously trigger all cameras and lights. Fallspeed is calculated from the time it takes to traverse the distance between the upper and lower triggering arrays. The trigger electronics filter out ambient light fluctuations associated with varying sunlight and shadows. The microprocessor onboard the MASC controls the camera system and communicates with the personal computer (PC). The image data is sent via FireWire 800 line, and fallspeed (and camera control) is sent via a Universal Serial Bus (USB) line that relies on RS232-over-USB serial conversion. See Table 1 for specific details on the MASC located at the Oliktok Point Mobile Facility on the North Slope of Alaska. The value-added product (VAP) detailed in this documentation analyzes the raw data (Section 2.0) using Python: images rely on OpenCV image processing library and derived aggregated statistics rely on some clever averaging. See Sections 4.1 and 4.2 for more details on what variables are computed.

47 OTHER INSTRUMENTATION↗

Maxdose-SR and popdose-SR routine release atmospheric dose models used at SRS

MAXDOSE-SR and POPDOSE-SR are used to calculate dose to the offsite Reference Person and to the surrounding Savannah River Site (SRS) population respectively following routine releases of atmospheric radioactivity. These models are currently accessed through the Dose Model Version 2014 graphical user interface (GUI). MAXDOSE-SR and POPDOSE-SR are personal computer (PC) versions of MAXIGASP and POPGASP, which both resided on the SRS IBM Mainframe. These two codes follow U.S. Nuclear Regulatory Commission (USNRC) Regulatory Guides 1.109 and 1.111 (1977a, 1977b). The basis for MAXDOSE-SR and POPDOSE-SR are USNRC developed codes XOQDOQ (Sagendorf et. al 1982) and GASPAR (Eckerman et. al 1980). Both of these codes have previously been verified for use at SRS (Simpkins 1999 and 2000). The revisions incorporated into MAXDOSE-SR and POPDOSE-SR Version 2014 (hereafter referred to as MAXDOSE-SR and POPDOSE-SR unless otherwise noted) were made per Computer Program Modification Tracker (CPMT) number Q-CMT-A-00016 (Appendix D). Version 2014 was verified for use at SRS in Dixon (2014).

61 RADIATION PROTECTION AND DOSIMETRY↗