Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHYSICS LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

The optical properties of platinum and gold in the vacuum ultraviolet

The optical constants of platinum and gold thin films have been determined in the spectral region of 40 to 200 nm by reflection measurements. The highly polarized continuum of synchrotron radiation emitted by the 240-MeV electron storage ring at the Physical Sciences Laboratory of the University of Wisconsin was used as a light source for the spectrum below 120 nm, while a windowless discharge lamp coupled to a normal incidence monochromator provided a source for the longer wavelengths. Optical constants were determined by a computer program based on iterative solutions to the Fresnel equations for reflection as a function of the angle of incidence.

Linton, R. C.↗

Structure and evolutionary history of the solar system. III.

Analysis of the plasma processes and the hydromagnetic aspects involved in the evolution of the solar system. In order to reduce the speculative element as far as possible, the present analysis tries to connect the cosmogonic processes as directly as possible to laboratory plasma physics and to space phenomena actually observed today. Models of the Laplacian type have been made obsolete by magnetohydrodynamics. Furthermore they are in conflict with observations. A new model is suggested. A plasma surrounding a rotating central body may attain a state of partial corotation which is determined by the balance between gravitation and the centrifugal force acting on a plasma in a dipole field. Condensation from a partially corotating plasma results in grains orbiting in ellipses with e = 1/3 and finally accreting to bodies at 2/3 of the central distance of the point of condensation. An application of the theory of the Saturnian rings and to the asteroidal belt shows that the fall-down ratio 2/3 (derived from the geometry of a dipole field) is essential for the understanding of their structure. The structure of the groups of planets and satellites is also discussed, but only in a preliminary way.

Alfven, H.↗

Reduction and analysis of data from cosmic dust experiments on Mariner 4, OGO 3, and Lunar Explorer 35

The analysis of data from the cosmic dust experiment on three NASA missions is discussed. These missions were Mariner IV, OGO III, and Lunar Explorer 35. The analysis effort has included some work in the laboratory of the physics of microparticle hypervelocity impact. This laboratory effort was initially aimed at the calibration and measurements of the different sensors being used in the experiment. The latter effort was conducted in order to better understand the velocity and mass distributions of the picogram sized ejecta particles.

Source record↗

A description and some measured acoustic characteristics of the Langley 220 cubic meter reverberation chamber

An initial acoustic calibration was performed for the NASA Langley Research Center reverberation chamber located on the aircraft Noise Reduction Laboratory. The physical characteristics of the chamber and measured data for the ambient acoustic levels, reverberation times, reflection coefficients, the spatial uniformity of acoustic energy as measured in the 1/3-octave bands from 40 Hz to 10 KHz and acoustic power levels of a standard source are described. Measured power levels compared very well with those published for the ILG standard source. The measured data indicate that for broadband noise fields, the reverberation room has acceptable acoustic performance in the frequency range from 100 Hz to 8 KHz.

Mueller, A. W.↗

Laboratory measurements of selected optical, physical, chemical, and remote-sensing properties of five water mixtures containing Calvert clay and a nonfluorescing dye

Total suspended solids concentrations ranged from 6.1 ppm to 24.3 ppm and sizes ranged between 1.5 micrometers and 10 micrometers with the most frequently occurring size less than 2 micrometers. Iron concentration was less than 1 percent of the total suspended solids. Nonfluorescing dye concentrations of the two mixtures were 20 ppm and 40 ppm. Attenuation coefficient for the five mixtures ranged from 4.8/m to 21.3/m. Variations in volume scattering function with phase angle were typical. Variations in attenuation and absorption coefficient with wavelength were similar for the mixtures without the dye. Attenuation coefficient of the mixtures with the dye increased for wavelengths less than 600 nm due to the dye's strong absorption peak near 500 nm. Reflectance increased as the concentration of Calvert clay increased and peaked near 600 nm. The nonfluorescent dye decreased the magnitude of the peak, but had practically no effect on the variation for wavelengths greater than 640 nm. At wavelengths less than 600 nm, the spectral variations of the mixtures with the dye were significantly different from those mixtures without the dye.

Usry, J. W.↗

PCDS as a tool in teaching and research at the University of Michigan

The Space Physics Research Laboratory's (SPRL) use of the Pilot Climate Data System (PCDS) is discussed. For this purpose, a computer center was established to provide the hardware and software necessary to fully utilize existing data bases for research and teaching purposes. A schematic of the SPRL network is given. The core of the system consists of two VAX 11/750s and a VAX 8600, networked through ETHERNET to several LSI 11/23 microprocessors. Much of the system is used for external communications with major networks and data centers. A VAX 11/750 provides DECNET services through the SPAN network to the PCDS. A functional diagram of PCDS usage is given. The browsing capabilities of the PCDS are used to generate data files, which are later transferred to the SPRL center for further data manipulation and display. This mode of operation for classroom instruction will be used to effectively use terminals and to simplify usage of the data base. The Atmosphere Explorer data base has been used successfully in a similar manner in courses related to the thermosphere and ionosphere. The main motivation to access the PCDS was to complement research efforts related to the High Resolution Doppler Imager (HRDI), to be flown on the Upper Atmosphere Research Satellite (UARS).

Abreu, V.↗

A Study of Space Station Contamination Effects

A workshop was held with the specific objective of reviewing the state-of-knowledge regarding Space Station contamination, the extent to which the various categories of contamination can be predicted, and the extent to which the predicted levels would interfere with onboard scientific investigations or space station functions. The papers presented at the workshop are compiled and address the following topics: natural environment, plasma electromagnetic environment, optical environment, particulate environment, spacecraft contamination, surface physics processes, laboratory experiments and vented chemicals/contaminants.

Torr, M. R.↗

Tropospheric and stratospheric wind profiling with a direct detection Doppler lidar

The Space Physics Research Laboratory at the University of Michigan has been operating a direct detection, high resolution Doppler Lidar (HRDL) to measure winds in the boundary layer, free troposphere and lower stratosphere. A direct detection Doppler lidar measures the Doppler shift of the aerosol or Rayleigh backscattered signal, from which the wind velocity vector can be retrieved (Benedetti-Michelangeli et al, 1972, 1974; Chanin et al., 1989; Abreu et al., 1992). The system components are shown. The transmitting system is a Continuum NY-60 Nd:YAG laser frequency doubled to a wavelength of 532 nm. The laser is injection seeded for single line mode operation yielding a linewidth of 0.0045 cm(exp -1) (135 MHz) with excellent shot-to-shot frequency stability. The laser produces 60 mJ pulses and operates at a 50 Hz repetition rate for an effective output power of 3.0 W. A description of the University of Michigan's Doppler lidar is given with examples of wind profiles for the boundary layer, free troposphere, and for the lower stratosphere. The system provides a reliable method of remotely measuring the wind. The wind error is smallest in regions of high aerosols. The system also produces aerosol extinction profiles versus altitude which can be determined by the shape of the spectra. The system has been installed in a trailor so that measurements can be made for field campaigns. Winds and aerosol data are available immediately at the site for use in forecasting.

Abreu, Vincent J.↗

Solar extreme ultraviolet sensor and advanced langmuir probe

For more than two decades, the staff of the Space Physics Research Laboratory (SPRL) has collaborated with the Goddard Space Flight Center (GSFC) in the design and implementation of Langmuir probes (LP). This program of probe development under the direction of Larry Brace of GSFC has evolved methodically with innovations to: improve measurement precision, increase the speed of measurement, and reduce the weight, size, power consumption and data rate of the instrument. Under contract NAG5-419 these improvements were implemented and are what characterize the Advanced Langmuir Probe (ALP). Using data from the Langmuir Probe on the Pioneer Venus Orbiter, Brace and Walter Hoegy of GSFC demonstrated a novel method of monitoring the solar extreme ultraviolet (EUV) flux. This led to the idea of developing a sensor similar to a Langmuir probe specifically designed to measure solar EUV (SEUV) that uses a similar electronics package. Under this contract, a combined instrument package of the ALP and SEUV sensor was to be designed, constructed, and laboratory tested. Finally the instrument was to be flight tested as part of sounding rocket experiment to acquire the necessary data to validate this method for possible use in future earth and planetary aeronomy missions. The primary purpose of this contract was to develop the electronics hardware and software for this instrument, since the actual sensors were suppied by GSFC. Due to budget constraints, only a flight model was constructed. These electronics were tested and calibrated in the laboratory, and then the instrument was integrated into the rocket payload at Wallops Flight Facility where it underwent environmental testing. After instrument recalibration at SPRL, the payload was reintegrated and launched from the Poker Flat Research Range near Fairbanks Alaska. The payload was successfully recovered and after refurbishment underwent further testing and developing to improve its performance for future use.

Voronka, N. R.↗

Three-dimensional magnetotail equilibria by numerical relaxation techniques

Consideration is given to a numerical method to iteratively approach 3D magnetostatic force equilibria, with modeling emphasis on the development of a suitable model of the earth's magnetotail, including a portion of the inner magnetosphere, i.e., on models which violate the 'tail approximation' commonly employed in analytical models. The numerical approach is compared to methods developed for laboratory plasma physics. The method is applied to the magnetotail outside of 10 R(E), using Tsyganenko's (1987) model for the quiet magnetosphere as an initial condition. The changes of the magnetic field necessary to yield an equilibrium configuration and the resulting distribution of the self-consistently derived pressure are discussed. It is shown that a self-consistent magnetotail equilibrium based on a close approximation to Tsyganenko's requires a region 1 type current system, which is not present in the initial configuration.

Hesse, Michael↗

Micro- to macroscale perspectives on space plasmas

The Earth's magnetosphere is the most accessible of natural collisionless plasma environments; an astrophysical plasma 'laboratory'. Magnetospheric physics has been in an exploration phase since its origin 35 years ago but new coordinated, multipoint observations, theory, modeling, and simulations are moving this highly interdisciplinary field of plasma science into a new phase of synthesis and understanding. Plasma systems are ones in which binary collisions are relatively negligible and collective behavior beyond the microscale emerges. Most readily accessible natural plasma systems are collisional and nearest-neighbor classical interactions compete with longer-range plasma effects. Except for stars, most space plasmas are collisionless, however, and the effects of electrodynamic coupling dominate. Basic physical processes in such collisionless plasmas occur at micro-, meso-, and macroscales that are not merely reducible to each other in certain crucial ways as illustrated for the global coupling of the Earth's magnetosphere and for the nonlinear dynamics of charged particle motion in the magnetotail. Such global coupling and coherence makes the geospace environment, the domain of solar-terrestrial science, the most highly coupled of all physical geospheres.

Eastman, Timothy E.↗

Experimental studies of an ECR plasma thruster

The Electron Cyclotron Resonance (ECR) thruster is a proposed electrodeless space electric propulsion device with interesting and little understood physics. A laboratory ECR thruster was run in a vacuum tank at pressures in the 10 exp -5 torr range using 2.12 GHz microwave beam and Ar gas propellant. Movable diagnostic probes (a Faraday cup and a gridded energy analyzer) measured plasma characteristics as propellant gas flow rate and input microwave power level were varied. Ion energy and flux data were used to calculate I(sp), propulsive efficiency, and thrust. The ion flux profiles show an unexpected depression on the thruster axis for low tank pressures that disappears as the tank pressure increases. Ion energies decrease as the flow rate and pressure increase, but the microwave power level affects the energy only negligibly. The calculated propulsion parameters demonstrate that the efficiency of the laboratory device is low, and that tank pressure greatly changes the performance.

Kaufman, D. A.↗

Helium tables.

These tables are intended to provide a standard method and to facilitate the calculation of the quantity of "Standard Helium" in high pressure containers. The research data and the formulas used in the preparation of the tables were furnished by the Research Laboratory of Physical Chemistry, of the Massachusetts Institute of Technology.

Havill, Clinton H↗

Remote sounding of tropospheric minor constituents

The etalon interferometer, or Fabry-Perot interferometer (FPI), with its high throughput and high spectral resolution was widely used in the remote-sensing measurements of the earth's atmospheric composition, winds, and temperatures. The most recent satellite instruments include the Fabry-Perot interferometer flown on the Dynamics Explorer-2 (DE-2) and the High Resolution Doppler Imager (HRDI) to be flown on the Upper Atmosphere Research Satellite (UARS). These instruments measure the Doppler line profiles of the emission and absorption of certain atmospheric species (such as atomic oxygen) in the visible spectral region. The successful space flight of DE-FPI and the test and delivery of UARS-HRDI demonstrated the extremely high spectral resolution and ruggedness of the etalon system for the remote sensing of earth and planetary atmospheres. Recently, an innovative FPI focal plane detection technique called the Circle-to-Line Interferometer Optical (CLIO) system was invented at the Space Physics Research Laboratory (SPRL). The CLIO simplifies the FPI focal plane detection process by converting the circular rings or fringes into a linear pattern similar to that produced by a conventional spectrometer, while retaining the throughput advantage of the etalon interferometer. CLIO makes the use of linear array detectors more practical and efficient with FPI, the combination of FPI and CLIO represents a very promising new technique for the remote sensing of the lower atmospheres of Earth, Mars, Venus, Neptune, and other planets. The Multiorder Etalon Spectrometer (MOES), as a combination of the rugged etalon and the CLIO, compares very favorably to other spaceborne optical instruments in terms of performance versus complexity. The feasibility of an advanced etalon spectrometer for the remote sensing of tropospheric trace species, particularly carbon monoxide (CO), nitrous oxide (N2O), and methane (CH4) was discussed. The etalon atmospheric spectroscopy techniques are described, instrument design and related technical issues are discussed. The primary objective is to establish the concept of atmospheric spectroscopy with the CLIO and etalon system and its applications for the measurements of tropospheric trace species analyze system requirements and performance, determine the feasibility of components and subsystem implementation with available technology, and develop inversion algorithm for retrieval simulation and data analysis.

Drayson, S. Roland↗

HRMA calibration handbook: EKC gravity compensated XRCF models

This document, consisting of hardcopy printout of explanatory text, figures, and tables, represents one incarnation of the AXAF high resolution mirror assembly (HRMA) Calibration Handbook. However, as we have envisioned it, the handbook also consists of electronic versions of this hardcopy printout (in the form of postscript files), the individual scripts which produced the various figures and the associated input data, the model raytrace files, and all scripts, parameter files, and input data necessary to generate the raytraces. These data are all available electronically as either ASCII or FITS files. The handbook is intended to be a living document and will be updated as new information and/or fabrication data on the HRMA are obtained, or when the need for additional results are indicated. The SAO Mission Support Team (MST) is developing a high fidelity HRMA model, consisting of analytical and numerical calculations, computer software, and databases of fundamental physical constants, laboratory measurements, configuration data, finite element models, AXAF assembly data, and so on. This model serves as the basis for the simulations presented in the handbook. The 'core' of the model is the raytrace package OSAC, which we have substantially modified and now refer to as SAOsac. One major structural modification to the software has been to utilize the UNIX binary pipe data transport mechanism for passing rays between program modules. This change has made it possible to simulate rays which are distributed randomly over the entrance aperture of the telescope. It has also resulted in a highly efficient system for tracing large numbers of rays. In one application to date (the analysis of VETA-I ring focus data) we have employed 2 x 10(exp 7) rays, a substantial improvement over the limit of 1 x 10(exp 4) rays in the original OSAC module. A second major modification is the manner in which SAOsac incorporates low spatial frequency surface errors into the geometric raytrace. The original OSAC included the ability to use Legendre-Fourier polynomials to describe deviations from the basic optical prescription. To this we have added bicubic splines to address a deficiency in the handling of the sharper deformations in the areas of mirror support pads. SAO has developed software (TRANS-FIT) to translate the most common finite element analysis models into these forms for incorporation into the raytrace program.

Tananbaum, H. D.↗

Global tropospheric and total ozone monitoring with a Double-Etalon Fabry-Perot interferometer

Knowledge of the global scale distribution of atmospheric ozone and its temporal variability can be achieved using a satellite-based nadir-viewing device making high spectral resolution measurements with high signal-to-noise ratios. This would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface and interfering species. The Fabry-Perot interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. The periodic nature of the Fabry-Perot instrument function can be advantageous when observation of periodic spectra is desired. However, for most applications, additional optical elements are necessary to reduce the effect of unwanted passbands. This is frequently accomplished using additional Fabry-Perot etalons in a series configuration in conjunction with a bandpass filter. This paper discusses a Fabry-Perot interferometer conceptual instrument design to achieve tropospheric and total ozone monitoring capability from a satellite-based nadir-viewing geometry. The design involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). The impact of inter-etalon reflections has been reduced to acceptable levels by placement of a slightly attenuating medium in between the etalons. A passive device is selected for low power consumption, and continuous day/night coverage, independent of solar zenith angle, is enabled by observing within the strong 9.6 micron ozone infrared band. The IR-FPI detection will be performed through implementation of the new Circle to Line Interferometer Optical (CLIO) system, developed by researchers at the Space Physics Research Laboratory (SPRL) of the University of Michigan, to accomplish focal plane fringe detection; the CLIO system converts the circular interferometric fringes into a linear pattern which then can be detected by conventional linear array detectors. A multiplex signal advantage is achievable as all necessary frequencies can be measured simultaneously using a multichannel configuration. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance.

Larar, Allen M.↗

Development And Application Of The Ion Microprobe For Analysis Of Extraterrestrial Materials

This report covers the work carried out under NASA Grant NAG5-4083. The research was directed toward analyses of early solar system material, of presolar grains preserved in meteorites, and toward theoretical studies of nucleosynthesis in stars related to the chemical evolution of the galaxy and the formation of the solar system. The work was carried out over the time period 15 February 1998 - 31 May 2001 and involved the participation of the following individuals: M. Busso, Visiting Associate, Professor of Astrophysics, Perugia University, Italy; B.-G. Choi, research fellow, now Associate Professor at Seoul National University, Korea; H. C. Connolly, research fellow, now at Kingsborough Community College, CUNY; R. Gallino, Visiting Associate, Professor of Astrophysics, University of Torino; Y. Guan, Smithsonian Institution; C. Hohenberg, Professor of Physics, Washington University, St. Louis; M. Heinrich, electronics and systems engineer, Caltech; W. Hsu, research fellow, Caltech; T. LaTourrette, research fellow, now at Rand Corporation; G. R. Huss, Senior Research Scientist, now at Arizona State University; N. Krestina, research fellow in geochemistry, Caltech; G. J. MacPherson, Smithsonian Institution; K. Nollett, research fellow in astrophysics; Y.-Z. Qian, Professor of Physics, University of Minnesota; G. Srinivasan, research fellow, now Research Scientist, Physical Research Laboratory, Ahmedabad, India.

Wasserburg, G. J.↗

Neutron dosimetry in low-earth orbit using passive detectors

This paper summarizes neutron dosimetry measurements made by the USF Physics Research Laboratory aboard US and Russian LEO spacecraft over the past 20 years using two types of passive detector. Thermal/resonance neutron detectors exploiting the 6Li(n,T) alpha reaction were used to measure neutrons of energies <1 MeV. Fission foil neutron detectors were used to measure neutrons of energies above 1 MeV. While originally analysed in terms of dose equivalent using the NCRP-38 definition of quality factor, for the purposes of this paper the measured neutron data have been reanalyzed and are presented in terms of ambient dose equivalent. Dose equivalent rate for neutrons <1 MeV ranged from 0.80 microSv/d on the low altitude, low inclination STS-41B mission to 22.0 microSv/d measured in the Shuttle's cargo bay on the highly inclined STS-51F Spacelab-2 mission. In one particular instance a detector embedded within a large hydrogenous mass on STS-61 (in the ECT experiment) measured 34.6 microSv/d. Dose equivalent rate measurements of neutrons >1 MeV ranged from 4.5 microSv/d on the low altitude STS-3 mission to 172 microSv/d on the ~6 year LDEF mission. Thermal neutrons (<0.3 eV) were observed to make a negligible contribution to neutron dose equivalent in all cases. The major fraction of neutron dose equivalent was found to be from neutrons >1 MeV and, on LDEF, neutrons >1 MeV are responsible for over 98% of the total neutron dose equivalent. Estimates of the neutron contribution to the total dose equivalent are somewhat lower than model estimates, ranging from 5.7% at a location under low shielding on LDEF to 18.4% on the highly inclined (82.3 degrees) Biocosmos-2044 mission. c2001 Elsevier Science Ltd. All rights reserved.

Flight Experiment↗