Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIXELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

FAST PIXEL SPACE CONVOLUTION FOR COSMIC MICROWAVE BACKGROUND SURVEYS WITH ASYMMETRIC BEAMS AND COMPLEX SCAN STRATEGIES: FEBeCoP

Precise measurement of the angular power spectrum of the cosmic microwave background (CMB) temperature and polarization anisotropy can tightly constrain many cosmological models and parameters. However, accurate measurements can only be realized in practice provided all major systematic effects have been taken into account. Beam asymmetry, coupled with the scan strategy, is a major source of systematic error in scanning CMB experiments such as Planck, the focus of our current interest. We envision Monte Carlo methods to rigorously study and account for the systematic effect of beams in CMB analysis. Toward that goal, we have developed a fast pixel space convolution method that can simulate sky maps observed by a scanning instrument, taking into account real beam shapes and scan strategy. The essence is to pre-compute the 'effective beams' using a computer code, 'Fast Effective Beam Convolution in Pixel space' (FEBeCoP), that we have developed for the Planck mission. The code computes effective beams given the focal plane beam characteristics of the Planck instrument and the full history of actual satellite pointing, and performs very fast convolution of sky signals using the effective beams. In this paper, we describe the algorithm and the computational scheme that has been implemented. We also outline a few applications of the effective beams in the precision analysis of Planck data, for characterizing the CMB anisotropy and for detecting and measuring properties of point sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Cadmium zinc telluride pixel detectors for high-intensity x-ray imaging at free electron lasers

Here, this paper reports the first demonstration of high-intensity x-ray imaging using cadmium zinc telluride (CdZnTe) pixel detectors at a free electron laser (FEL). Prototype detectors were produced using the STFC large pixel detector (LPD) ASIC and sensors fabricated from a novel high-intensity-capable CdZnTe material produced by Redlen Technologies. Characterisation of the performance of this sensor material was completed at the Linac Coherent Light Source (LCLS) FEL. The detectors were operated at a frame rate of 1 MHz with 9.5 keV x-ray pulses delivered at a rate of 120 Hz. Measurements successfully demonstrated the linear response of the CdZnTe material to increasing numbers of x-rays up to a fluence of 8 GeV mm –2 per pulse, the limit of the dynamic range of the LPD ASIC.

47 OTHER INSTRUMENTATION↗

Effects of overlapping sources on cosmic shear estimation: Statistical sensitivity and pixel-noise bias

The next generation of dark-energy imaging surveys — so called “Stage-IV” surveys, such as that of the Rubin Observatory Legacy Survey of Space and Time (LSST) — will cross a threshold in the number density of detected sources on the sky that requires qualitatively different image analysis and measurement techniques compared to the current generation of Stage-III surveys. In Stage-IV surveys, a significant amount of the cosmologically useful information is due to sources whose images overlap with those of other sources on the sky. Here, we focus on the weak gravitational lensing probe, for which we expect the largest impact since the cosmic shear signal is primarily encoded in the estimated shapes of observed galaxies and thus directly impacted by overlaps. We introduce a framework based on the Fisher formalism to analyze the effect of the overlapping sources (“blending”) on the estimation of cosmic shear. This method gives concrete predictions for the minimum loss of information due to noise and blending for any choice of “deblending” scheme and shape-measurement algorithm. Our studies account for undetected sources but do not address their full effects and biases they may introduce. We use simulated images and predict this impact of blending for three surveys: the Dark Energy Survey (DES), the Hyper-Suprime Cam Subaru Strategic Program (HSC-SSP), and the Rubin LSST. Our methodology successfully estimates the statistical sensitivity to weak lensing for DES and HSC early results. For LSST, we present the expected loss in statistical sensitivity for the ten-year survey due to blending. We find that for approximately 62% of galaxies that are likely to be detected in full-depth LSST images, at least 1% of the flux in their pixels is from overlapping sources. We also find that the statistical correlations between measures of overlapping galaxies and, to a much lesser extent (0.2%) the higher shot noise level due to their presence, decrease the effective number density of galaxies, N eff , by ~ 18%. We calculate an upper limit on N eff of 39.4 galaxies per arcmin 2 in r band. We study the impact of stars on as a function of stellar density and illustrate the diminishing returns of extending the survey into lower Galactic latitudes. We extend the simulation-based Fisher formalism to predict the expected increase in pixel-noise bias due to blending for maximum-likelihood (ML) shape estimators. We find that noise bias depends sensitively on the particular shape estimator and measure of ensemble-average shape that is used, and properties of the galaxy that include redshift-dependent quantities such as size and luminosity. The source code for these studies is available online.[The documented software developed for the catalog-level studies are available in the open-source LSST DESC github repository https://github.com/LSSTDESC/WeakLensingDeblending. The software for analyzing one or two galaxies with user-defined parameters is in the open-source github repository https://github.com/ismael-mendoza/ShapeMeasurementFisherFormalism.]

79 ASTRONOMY AND ASTROPHYSICS↗

Recent progress of RD53 Collaboration towards next generation Pixel Read-Out Chip for HL-LHC

This paper is a review of recent progress of RD53 Collaboration. Results obtained on the study of the radiation effects on 65 nm CMOS have matured enough to define first strategies to adopt in the design of analog and digital circuits. Critical building blocks and analog very front end chains have been designed, tested before and after 5–800 Mrad. Small prototypes of 64×64 pixels with complex digital architectures have been produced, and point to address the main issues of dealing with extremely high pixel rates, while operating at very small in-time thresholds in the analog front end. Lastly, the collaboration is now proceeding at full speed towards the design of a large scale prototype, called RD53A, in 65 nm CMOS technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Module and electronics developments for the ATLAS ITk pixel system

The ATLAS experiment is preparing for an extensive modification of its detectors in the course of the planned HL-LHC accelerator upgrade around 2025. The ATLAS upgrade includes the replacement of the entire tracking system by an all-silicon detector (Inner Tracker, ITk). The five innermost layers of ITk will be a pixel detector built of new sensor and readout electronics technologies to improve the tracking performance and cope with the severe HL-LHC environment in terms of occupancy and radiation. Here, the total area of the new pixel system could measure up to 14 m 2 , depending on the final layout choice, which is expected to take place in 2018. In this paper an overview of the ongoing R&D activities on modules and electronics for the ATLAS ITk is given including the main developments and achievements in silicon planar and 3D sensor technologies, readout and power challenges.

47 OTHER INSTRUMENTATION↗

LArPix: demonstration of low-power 3D pixelated charge readout for liquid argon time projection chambers

In this work, we report the demonstration of a low-power pixelated readout system designed for three-dimensional ionization charge detection and digital readout of liquid argon time projection chambers (LArTPCs) . Unambiguous 3D charge readout was achieved using a custom-designed system-on-a-chip ASIC (LArPix) to uniquely instrument each pad in a pixelated array of charge-collection pads. The LArPix ASIC, manufactured in 180 nm bulk CMOS, provides 32 channels of charge-sensitive amplification with self-triggered digitization and multiplexed readout at temperatures from 80 K to 300 K . Using an 832-channel LArPix-based readout system with 3 mm spacing between pads, we demonstrated low-noise (0<50 e - RMS equivalent noise charge) and very low-power (<100 μW/channel) ionization signal detection and readout . The readout was used to successfully measure the three-dimensional ionization distributions of cosmic rays passing through a LArTPC, free from the ambiguities of existing projective techniques. The system design relies on standard printed circuit board manufacturing techniques, enabling scalable and low-cost production of large-area readout systems using common commercial facilities. This demonstration overcomes a critical technical obstacle for operation of LArTPCs in high-occupancy environments, such as the near detector site of the Deep Underground Neutrino Experiment (DUNE) .

47 OTHER INSTRUMENTATION↗

Test beam measurement of ams H35 HV-CMOS capacitively coupled pixel sensor prototypes with high-resistivity substrate

In the context of the studies of the ATLAS High Luminosity LHC programme, radiation tolerant pixel detectors in CMOS technologies are investigated. To evaluate the effects of substrate resistivity on CMOS sensor performance, the H35DEMO demonstrator, containing different diode and amplifier designs, was produced in ams H35 HV-CMOS technology using four different substrate resistivities spanning from 80 cm to 1000 cm. A glueing process using a high-precision flip-chip machine was developed in order to capacitively couple the sensors to FE-I4 Readout ASIC using a thin layer of epoxy glue with good uniformity over a large surface. The resulting assemblies were measured in beam test at the Fermilab Test Beam Facilities with 120 GeV protons and CERN SPS H8 beamline using 180 GeV pions. Furthermore, the in-time efficiency and tracking properties measured for the different sensor types are shown to be compatible with the ATLAS ITk requirements for its pixel sensors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conceptual study of a two-layer silicon pixel detector to tag the passage of muons from cosmic sources through quantum processors

Abstract Recent studies in quantum computing have shown that quantum error correction with large numbers of physical qubits are limited by ionizing radiation from high-energy particles. Depending on the physical setup of the quantum processor, the contribution of muons from cosmic sources can constitute a significant fraction of these interactions. As most of these muons are difficult to stop, we perform a conceptual study of a two-layer silicon pixel detector to tag their hits on a solid-state quantum processor instead. With a typical dilution refrigerator geometry model, we find that efficiencies greater than 50% are most likely to be achieved if at least one of the layers is operated at the deep-cryogenic (<1 K) flanges of the refrigerator. Following this finding, we further propose a novel research program that could allow the development of silicon pixel detectors that are fast enough to provide input to quantum error correction algorithms, can operate at deep-cryogenic temperatures, and have very low power consumption.

Instruments & Instrumentation↗

Testing the limits of ITkPixV2: the ATLAS inner tracker pixel detector readout chip

The ITkPixV2 chip is the final production readout chip for the ATLAS Phase 2 Inner Tracker (ITk) upgrade at the upcoming High-Luminosity LHC (HL-LHC). Due to the extraordinarily high peak luminosity at the HL-LHC of 5 × 1034 cm-1 s-1, ITkPixV2 must meet significant increases in nearly all design requirements compared to the current ATLAS Inner Detector (ID), including a 10× increase in trigger rate, a 7.5× increase in hit rate, a 3× increase in radiation tolerance, and a 12.5× decrease in pixel current draw per unit area, all while maintaining a similar power per unit area as present pixel detectors. Here we present the first measurements of the ITkPixV2 chip operated at the limits of the full chip design requirements, including in particular a measurement of the activity-induced current of the chip as a function of increasing hit rate.

Le Pottier, L↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

High-dynamic-range coherent diffractive imaging: ptychography using the mixed-mode pixel array detector

Coherent (X-ray) diffractive imaging (CDI) is an increasingly popular form of X-ray microscopy, mainly due to its potential to produce high-resolution images and the lack of an objective lens between the sample and its corresponding imaging detector. One challenge, however, is that very high dynamic range diffraction data must be collected to produce both quantitative and high-resolution images. In this work, hard X-ray ptychographic coherent diffractive imaging has been performed at the P10 beamline of the PETRA III synchrotron to demonstrate the potential of a very wide dynamic range imaging X-ray detector (the Mixed-Mode Pixel Array Detector, or MM-PAD). The detector is capable of single photon detection, detecting fluxes exceeding 1 × 10 8 8-keV photons pixel -1 s -1 , and framing at 1 kHz. A ptychographic reconstruction was performed using a peak focal intensity on the order of 1 × 10 10 photons µm -2 s -1 within an area of approximately 325 nm × 603 nm. This was done without need of a beam stop and with a very modest attenuation, while `still' images of the empty beam far-field intensity were recorded without any attenuation. The treatment of the detector frames and CDI methodology for reconstruction of non-sensitive detector regions, partially also extending the active detector area, are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of thermal neutrons with a CMOS pixel sensor for a future dosemeter

The RaMsEs group (Radioprotection et Mesures Environnementales) is developing a new compact device for operational neutron dosimetry. The electronic part of the detector is made of an integrated active pixel sensor, originally designed for tracking in particle physics. This device has useful features for neutrons, such as high detection efficiency for charged particles, good radiation resistance, high readout speed, low power consumption and high rejection of photon background. A good response of the device to fast neutrons has already been demonstrated [1]. In order to test the sensibility of the detector to thermal neutrons, experiments have been carried out with a 512 x 512 pixel CMOS sensor on a californium source moderated with heavy water (Cf.D{sub 2}O) on the Van Gogh irradiator at the LMDN, IRSN, Cadarache (France)). A thin boron converter is used to benefit from the significant cross section of the {sup 10}B (n,{alpha}) {sup 7}Li reaction. Results show a high detection efficiency (around 10{sup -3}) of the device to thermal neutrons. Our measurements are in good agreement with GEANT4 Monte Carlo simulations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Skipper-in-CMOS: Nondestructive Readout With Subelectron Noise Performance for Pixel Detectors

The Skipper-in-CMOS image sensor integrates the nondestructive readout capability of skipper charge coupled devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode (PPD) in a CMOS imaging process while taking advantage of in-pixel signal processing. This allows both single photon counting as well as high frame rate readout through highly parallel processing. The first results obtained from a ${15} \times {15}~\mu $ m2 pixel cell of a Skipper-in-CMOS sensor fabricated in Tower Semiconductor’s commercial 180-nm CMOS image sensor process are presented. Measurements confirm the expected reduction of the readout noise with the number of samples down to deep subelectron noise of $0.15\text {e}^ - $ , demonstrating the charge transfer operation from the PPD and the single photon counting operation when the sensor is exposed to light. This article also discusses new testing strategies employed for its operation and characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, simulation, fabrication, and preliminary tests of 3D CMS pixel detectors for the super-LHC

The Super-LHC upgrade puts strong demands on the radiation hardness of the innermost tracking detectors of the CMS, which cannot be fulfilled with any conventional planar detector design. The so-called 3D detector architectures, which feature columnar electrodes passing through the substrate thickness, are under investigation as a potential solution for the closest operation points to the beams, where the radiation fluence is estimated to reach 10{sup 16} n{sub eq}/cm{sup 2}. Two different 3D detector designs with CMS pixel readout electronics are being developed and evaluated for their advantages and drawbacks. The fabrication of full-3D active edge CMS pixel devices with p-type substrate has been successfully completed at SINTEF. In this paper, we study the expected post-irradiation behaviors of these devices with simulations and, after a brief description of their fabrication, we report the first leakage current measurement results as performed on wafer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixel-Based Correction for Charge Transfer Inefficiency in the Hubble Space Telescope Advanced Camera for Surveys

Charge Transfer Inefficiency (CTI) due to radiation damage above the Earth's atmosphere creates spurious trailing in Hubble Space Telescope (HST) images. Radiation damage also creates unrelated warm pixels - but these happen to be perfect for measuring CTI. We model CTI in the Advanced Camera for Surveys (ACS)/Wide Field Channel (WFC) and construct a physically motivated correction scheme. This operates on raw data, rather than secondary science products, by returning individual electrons to pixels from which they were unintentionally dragged during readout. We apply our correction to images from the HST COSMOS survey, successfully reducing the CTI trails by a factor of ~30 everywhere in the CCD and at all flux levels. We quantify changes in galaxy photometry, astrometry and shape. The remarkable 97% level of correction is more than sufficient to enable a (forthcoming) reanalysis of downstream science products, and the collection of larger surveys.

Massey, Richard↗

Proof of principle study of the use of a CMOS active pixel sensor for proton radiography

Purpose: Proof of principle study of the use of a CMOS active pixel sensor (APS) in producing proton radiographic images using the proton beam at the Massachusetts General Hospital (MGH). Methods: A CMOS APS, previously tested for use in s-ray radiation therapy applications, was used for proton beam radiographic imaging at the MGH. Two different setups were used as a proof of principle that CMOS can be used as proton imaging device: (i) a pen with two metal screws to assess spatial resolution of the CMOS and (ii) a phantom with lung tissue, bone tissue, and water to assess tissue contrast of the CMOS. The sensor was then traversed by a double scattered monoenergetic proton beam at 117 MeV, and the energy deposition inside the detector was recorded to assess its energy response. Conventional x-ray images with similar setup at voltages of 70 kVp and proton images using commercial Gafchromic EBT 2 and Kodak X-Omat V films were also taken for comparison purposes. Results: Images were successfully acquired and compared to x-ray kVp and proton EBT2/X-Omat film images. The spatial resolution of the CMOS detector image is subjectively comparable to the EBT2 and Kodak X-Omat V film images obtained at the same object-detector distance. X-rays have apparent higher spatial resolution than the CMOS. However, further studies with different commercial films using proton beam irradiation demonstrate that the distance of the detector to the object is important to the amount of proton scatter contributing to the proton image. Proton images obtained with films at different distances from the source indicate that proton scatter significantly affects the CMOS image quality. Conclusion: Proton radiographic images were successfully acquired at MGH using a CMOS active pixel sensor detector. The CMOS demonstrated spatial resolution subjectively comparable to films at the same object-detector distance. Further work will be done in order to establish the spatial and energy resolution of the CMOS detector for protons. The development and use of CMOS in proton radiography could allow in vivo proton range checks, patient setup QA, and real-time tumor tracking.

60 APPLIED LIFE SCIENCES↗

Optimization of convergent collimators for pixelated SPECT systems

Purpose: The optimization of the collimator design is essential to obtain the best possible sensitivity in single photon emission computed tomography imaging. The aim of this work is to present a methodology for maximizing the sensitivity of convergent collimators, specifically designed to match the pitch of pixelated detectors, for a fixed spatial resolution value and to present some initial results using this approach. Methods: Given the matched constraint, the optimal collimator design cannot be simply found by allowing the highest level of septal penetration and spatial resolution consistent with the imposed restrictions, as it is done for the optimization of conventional collimators. Therefore, an algorithm that interactively calculates the collimator dimensions, with the maximum sensitivity, which respect the imposed restrictions was developed and used to optimize cone and fan beam collimators with tapered square-shaped holes for low (60-300 keV) and high energy radiation (300-511 keV). The optimal collimator dimensions were locally calculated based on the premise that each hole and septa of the convergent collimator should locally resemble an appropriate optimal matched parallel collimator. Results: The optimal collimator dimensions, calculated for subcentimeter resolutions (3 and 7.5 mm), common pixel sizes (1.6, 2.1, and 2.5 mm), and acceptable septal penetration at 140 keV, were approximately constant throughout the collimator, despite their different hole incidence angles. By using these input parameters and a less strict septal penetration value of 5%, the optimal collimator dimensions and the corresponding mass per detector area were calculated for 511 keV. It is shown that a low value of focal distance leads to improvements in the average sensitivity at a fixed source-collimator distance and resolution. The optimal cone beam performance outperformed that of other optimal collimation geometries (fan and parallel beam) in imaging objects close to the collimator surface. Conclusions: These results demonstrate the potential of this kind of optimal convergent collimators for the use in small field of view imaging applications.

43 PARTICLE ACCELERATORS↗

Design and Evaluation of a Pixelated PSD-capable Scintillator Detector with SiPM Readout

We present the detector response comparison between a 10x10 pixellated array of scintillator read out with Anger logic using four 2" Hamamatsu R7724-100 super bialkali photomultiplier tubes (PMT) and a custom Silicon photomultiplier (SiPM) board consisting of 100 C-series 6x6 mm SiPMs from SensL. An array of these pixellated detectors are currently used in the Neutron Coded Aperture (NCA) imaging system. The energy, timing and pulse shape discrimination response using both readout schemes are presented, along with an analysis of multiple scatter events occurring within the block. An evaluation of the impact of photodetector readout on the overall detection efficiency and imaging accuracy is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗