Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Electron-muon correlation as a new probe of strongly interacting quark-gluon plasma

As a new and clean probe to the strongly interacting quark-gluon plasma (sQGP), we propose an azimuthal correlation of an electron and a muon that originate from the semileptonic decay of charm and bottom quarks. By solving the Langevin equation for the heavy quarks under the hydrodynamic evolution of the hot plasma, we show that substantial quenching of the away-side peak in the electron-muon correlation can be seen if the sQGP drag force acting on heavy quarks is large enough as suggested from the gauge/gravity correspondence. The effect could be detected in high-energy heavy ion collisions at the Relativistic Heavy Ion Collider and the Large Hadron Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Invited Article: Data analysis of the Floating Potential Measurement Unit aboard the International Space Station

We present data from the Floating Potential Measurement Unit (FPMU) that is deployed on the starboard truss of the International Space Station. The FPMU is a suite of instruments capable of redundant measurements of various plasma parameters. The instrument suite consists of a floating potential probe, a wide-sweeping spherical Langmuir probe, a narrow-sweeping cylindrical Langmuir probe, and a plasma impedance probe. This paper gives a brief overview of the instrumentation and the received data quality, and then presents the algorithm used to reduce I-V curves to plasma parameters. Several hours of data are presented from August 5, 2006 and March 3, 2007. The FPMU derived plasma density and temperatures are compared with the International Reference Ionosphere (IRI) and Utah State University-Global Assimilation of Ionospheric Measurement (USU-GAIM) models. Our results show that the derived in situ density matches the USU-GAIM model better than the IRI, and the derived in situ temperatures are comparable to the average temperatures given by the IRI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quasistatic probes of the QCD plasma

Screening correlators and masses were studied at finite temperature in QCD with two flavors of dynamical staggered quarks on a lattice. The spectrum of screening masses show a hierarchical approach to chiral symmetry restoration. Control of explicit chiral symmetry breaking through the quark mass was shown to be an important step toward understanding this phenomenon. No sign of decay was found in the finite temperature scalar mesonlike correlators in the confined phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structure of the Wall Sheath in a Gas-Discharge Plasma for an Arbitrary Orientation of a Flat Probe Relative to the Electric Field in the Plasma

We investigate the structure of the wall sheath of a gas discharge near a flat surface at a negative potential for high mean electron energy. It is shown that in the conditions where the mean energy of ions in the plasma is much lower than the mean electron energy, the parameters of the wall sheath weakly depend on the mutual orientation of the normal to the surface and the electric field in the plasma for an arbitrary ratio of the Debye radius to the ion mean free path relative to the resonant charge exchange process. It is found that for inert gases (He, Ar) for ratio E/P of the electric field to pressure exceeding 10 V/(cm Torr) in the plasma, the disregard of ionization in the perturbed wall sheath can lead to substantial errors in the calculation of its parameters. It is shown that the ionization leads to an increase in the electric field in the wall sheath and, as a consequence, to an increase in the mean velocity of ions at the boundary between the quasi-neutral presheath and the part of the perturbed wall sheath in which quasi-neutrality is substantially violated. The parameters of the wall sheath where quasi-neutrality is significantly violated depend on the ionization rate much less strongly than the corresponding parameters of the quasi-neutral presheath. We have determined the relation for concentration of charged particles in the unperturbed plasma from the ion saturation current considering the actual ion energy distribution function in the plasma as well as ionization in the presheath and the part of the perturbed wall sheath in which quasi-neutrality is violated significantly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional numerical simulation of current collection by a probe in a magnetized plasma

A three-dimensional numerical model for current collection in a magnetized plasma is reported. The model is based on an electrostatic particle-in-cell code. The model yields self-consistent sheath structure including distributions of plasma and the electric potential around the body and the collection of electrons. The analytical theory of current collection by a body in a magnetized plasma yields an upper bound for the collected current determined by the conservation of energy and canonical angular momentum. The theory shows that the collected charged particles come from a cylindrical volume aligned with the magnetic shadow of the body; the maximum radius r(sub o) of this volume is determined by the body size, body potential, and the ambient magnetic field. This theory does not deal with the sheath structure around the body. The condition for the actual current to approach the upper-bound value has been a matter of debate. Our simulations reveal when and why the collected current becomes equal to its upper-bound value. Sheath size in the radial direction perpendicular to the axial ambient magnetic field is determined by the current-limiting radius r(sub o). Our simulation yields time-average current in good agreement with its upper bound. This feature of the current collection is explained as follows: Once electrons enter the sheath, some of them are freely accelerated perpendicular to the magnetic field because they are demagnetized by the large gradients in the perpendicular electric fields. Simulations show a large perpendicular acceleration, producing perpendicular energy as large as that determined by the potential on the body, especially in the region where perpendicular electric fields (E perpendicular) are the strongest. An analysis shows that the demagnetization of electrons occurs above a threshold potential on the body. This threshold condition follows from the breakdown of the adiabaticity of the electron dynamics inside the sheath.

Singh, Nagendra↗

Spatially resolved measurements of ion density and electron temperature in a dual-frequency capacitively coupled plasma by complete floating double probe technique

Spatially resolved measurements of the ion density and electron temperature in a dual-frequency capacitively coupled Ar discharge plasma are performed with a newly developed complete floating double probe. Axial and radial distributions of the ion density and electron temperature under various high-frequency (HF) power and gas pressure were studied in detail. Both the ion density and the electron temperature increased with increasing HF power. With increasing gas pressure from 1.3 to 9.3 Pa, the radial profile of ion density below the driven electrode experienced a change from ''bimodal'' to ''unimodal'' shape, with better uniformity being achieved at the optimal pressure of about 5 Pa. In addition, changing the axial profile of ion density was also observed with the peak shift toward the powered electrode at higher pressures. The measured results showed satisfying consistency with that of improved two dimensional fluid simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A tetrahedral probe constellation approach for measuring canonical momentum in self-organized laboratory plasma

To examine momentum redistribution processes and study generalized helicities during plasma relaxation in Madison Symmetric Torus, MST, reversed field pinch plasma, a new probe is being tested to measure the full 3D plasma ion flow and magnetic field vectors at four spatial locations arranged in a tetrahedral shape reminiscent of a satellite measurement constellation. These measurements permit calculation of ∇ x $\vec{u}$ and canonical momentum, where $\vec{u}$ is the plasma ion flow vector. The probe consists of four probe heads arranged in a tetrahedral pattern, with an overall probe diameter of ∼31.75 mm. The probe head diameter is ∼1.0 cm, which is of the order of the ion Larmor radius. Each head has four molybdenum electrodes, also arranged in tetrahedral geometry, which are biased relative to a common return electrode, using four power supplies (one for each head), to measure the local ion flow. Additionally, each head has three orthogonal magnetic pickup coils within it to measure equilibrium and fluctuating magnetic fields.

Physics - Plasma physics↗

Plasma dynamics in a discharge produced by a pulsed dual frequency inductively coupled plasma source

Using a Langmuir probe, time resolved measurements of plasma parameters were carried out in a discharge produced by a pulsed dual frequency inductively coupled plasma source. The discharge was sustained in an argon gas environment at a pressure of 10 mTorr. The low frequency (P{sub 2} {sub MHz}) was pulsed at 1 kHz and a duty ratio of 50%, while high frequency (P{sub 13.56} {sub MHz}) was maintained in the CW mode. All measurements were carried out at the center of the discharge and 20 mm above the substrate. The results show that, at a particular condition (P{sub 2} {sub MHz} = 200 W and P{sub 13.56} {sub MHz }= 600 W), plasma density increases with time and stabilizes at up to ∼200 μs after the initiation of P{sub 2} {sub MHz} pulse at a plasma density of (2 × 10{sup 17} m{sup −3}) for the remaining duration of pulse “on.” This stabilization time for plasma density increases with increasing P{sub 2} {sub MHz} and becomes ∼300 μs when P{sub 2} {sub MHz} is 600 W; however, the growth rate of plasma density is almost independent of P{sub 2} {sub MHz}. Interestingly, the plasma density sharply increases as the pulse is switched off and reaches a peak value in ∼10 μs, then decreases for the remaining pulse “off-time.” This phenomenon is thought to be due to the sheath modulation during the transition from “pulse on” to “pulse off” and partly due to RF noise during the transition period. The magnitude of peak plasma density in off time increases with increasing P{sub 2} {sub MHz}. The plasma potential and electron temperature decrease as the pulse develops and shows similar behavior to that of the plasma density when the pulse is switched off.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The FIELDS Instrument Suite for Solar Probe Plus Measuring the Coronal Plasma and Magnetic Field, Plasma Waves and Turbulence, and Radio Signatures of Solar Transients

NASA's Solar Probe Plus (SPP) mission will make the first in situ measurements of the solar corona and the birthplace of the solar wind. The FIELDS instrument suite on SPP will make direct measurements of electric and magnetic fields, the properties of in situ plasma waves, electron density and temperature profiles, and interplanetary radio emissions, amongst other things. Here, we describe the scientific objectives targeted by the SPP/FIELDS instrument, the instrument design itself, and the instrument concept of operations and planned data products.

Solar Probe Plus↗

Flush-mounted probe diagnostics for argon glow discharge plasma

A comparison is made between plasma parameters measured by a flush-mounted probe (FP) and a cylindrical probe (CP) in argon glow discharge plasma. Parameters compared include the space potential, the plasma density, and the effective electron temperature. It is found that the ion density determined by the FP agrees well with the electron density determined by the CP in the quasi-neutral plasma to better than 10%. Moreover, the space potential and effective electron temperature calculated from electron energy distribution function measured by the FP is consistent with that measured by the CP over the operated discharge current and pressure ranges. These results present the FP can be used as a reliable diagnostic tool in the stable laboratory plasma and also be anticipated to be applied in other complicated plasmas, such as tokamaks, the region of boundary-layer, and so on.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved double-probe study in a He-Hg afterglow plasma

An experimental double-probe technique is described which allows the He(+) ion density to be measured directly as a function of time in the afterglow of a helium-metal-vapor discharge. As an application example, two CW laser transitions of the He-Hg(+) laser at 6150 and 7944 A are considered which both arise from excited 7p (2) P terms of Hg II. The time-resolved double-probe technique is used to measure the destruction rate of the He(+) ion density, which is then compared with the spontaneous-emission decay rate for 7p (2) P terms of Hg II. The results obtained show unambiguously and directly that the dominant excitation process for the two transitions considered is a charge-transfer collisional reaction of the form He(+) plus Hg yields He plus metastable Hg(+) plus the energy defect for this reaction. It is noted that the time-resolved double-probe technique may provide a simple method for measuring ion mobilities in a multi-ion plasma.

Shay, T.↗

Measurements of the number density of water molecules in plasma by using a combined spectral−probe method

A novel method for measuring the number density of water molecules in low-temperature plasma is developed. The absolute intensities of rotational lines of the (0,0) band of the OH(A{sup 2}Σ–X{sup 2}Π) transition are used. Lines with sufficiently large rotational quantum numbers referring to the so-called “hot” group of molecules produced by electron-impact dissociative excitation of water molecules are chosen for measurements. The excitation rate of a process with a known cross section is determined by measuring the parameters of plasma electrons by means of the probe method. The measured number densities of molecules are compared with those in the initial plasma-forming mixture. The time evolution of the particle densities in plasma is investigated. The problems of the sensitivity and applicability of the absolute spectral method are considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗