Search NASA⌕ Search

SEARCH · Search NASA

Results for “POWER FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Different Factors Affecting Short Circuit Behavior of a Wind Power Plant

A wind power plant consists of a large number of turbines interconnected by underground cable. A pad-mount transformer at each turbine steps up the voltage from generating voltage (690 V) to a medium voltage (34.5 kV). All turbines in the plant are connected to the substation transformer where the voltage is stepped up to the transmission level. An important aspect of wind power plant (WPP) impact studies is to evaluate the short-circuit (SC) current contribution of the plant into the transmission network under different fault conditions. This task can be challenging to protection engineers due to the topology differences between different types of wind turbine generators (WTGs) and the conventional generating units. This paper investigates the short circuit behavior of a wind power plant for different types of faults. The impact of wind turbine types, the transformer configuration, and the reactive compensation capacitor will be investigated. The voltage response at different buses will be observed. Finally, the SC line currents will be presented along with its symmetrical components.

Fault contribution, induction generator, protectio↗

Photovoltaic Impact Assessment of Smart Inverter Volt-VAR Control on Distribution System Conservation Voltage Reduction and Power Quality

This report presents an impact assessment study of distributed photovoltaic (PV) with smart inverter Volt-VAR control on conservation voltage reduction (CVR) energy savings and distribution system power quality. CVR is a methodology of flattening and lowering a distribution system voltage profile in order to conserve energy. Traditional CVR relies on operating utility voltage regulators and switched capacitors. However, with the increased penetration of distributed PV systems, smart inverters provide the new opportunity to control local voltage and power factor by regulating the reactive power output, leading to a potential increase in CVR energy savings. This report proposes a methodology to implement CVR scheme by operating voltage regulators, capacitors, and autonomous smart inverter Volt-VAR control in order to achieve increased CVR benefit. Power quality is an important consideration when operating a distribution system, especially when implementing CVR. It is easy to measure the individual components that make up power quality, but a comprehensive method to incorporate all of these values into a single score has yet to be undertaken. As a result, this report proposes a power quality scoring mechanism to measure the relative power quality of distribution systems using a single number, which is aptly named the 'power quality score' (PQS). Both the CVR and PQS methodologies were applied to two distribution system models, one obtained from the Hawaiian Electric Company (HECO) and another obtained from Pacific Gas and Electric (PG&E). These two models were converted to the OpenDSS platform using previous model conversion tools that were developed by NREL. Multiple scenarios including various PV penetration levels and smart inverter densities were simulated to analyze the impact of smart inverter Volt-VAR support on CVR energy savings and feeder power quality. In order to analyze the CVR benefit and PQS, an annual simulation was conducted for each scenario.

14 SOLAR ENERGY↗

Advanced Photovoltaic Inverter Functionality using 500 kW Power Hardware-in-Loop Complete System Laboratory Testing: Preprint

With the increasing penetration of distribution connected photovoltaic (PV) systems, more and more PV developers and utilities are interested in easing future PV interconnection concerns by mitigating some of the impacts of PV integration using advanced PV inverter controls and functions. This paper describes the testing of a 500 kW PV inverter using Power Hardware-in-Loop (PHIL) testing techniques. The test setup is described and the results from testing the inverter in advanced functionality modes, not commonly used in currently interconnected PV systems, are presented. PV inverter operation under PHIL evaluation that emulated both the DC PV array connection and the AC distribution level grid connection are shown for constant power factor (PF) and constant reactive power (VAr) control modes. The evaluation of these modes was completed under varying degrees of modeled PV variability.

14 SOLAR ENERGY↗

A High-Power Wireless Charging System Development and Integration for a Toyota RAV4 Electric Vehicle

Several wireless charging methods are underdevelopment or available as an aftermarket option in the light-duty automotive market. However, there are not many studies detailing the vehicle integrations, particularly a complete vehicle integration with higher power levels. This paper presents the development, implementation, and vehicle integration of a high-power (>10 kW) wireless power transfer (WPT)-based electric vehicle (EV) charging system for a Toyota RAV4 vehicle. The power stages of the system are introduced with the design specifications and control systems including the active front-end rectifier with power factor correction (PFC), high frequency power inverter, high frequency isolation transformer, coupling coils, vehicle side full-bridge rectifier and filter, and the vehicle battery. The operating principles of the control, communications, and protection systems are also presented in addition to the alignment and the driver interface system. The physical limitations of the system are also defined that would prevent the system operating at higher levels. The experiments are carried out using the integrated vehicle and the results obtained to demonstrate the system performance including the stage-by-stage efficiencies with matched and interoperable primary and secondary coils.

plug-in electric vehicle charger↗

Power packet networks for wave energy converter arrays

One of the biggest challenges for all renewable energy sources (RES) is that they are variable power generators which will require reactive power or energy storage systems (ESS) to provide reliable power quality (ideally power factor of one) at the power grid generation side. The present invention is directed to a power packet network (PPN) for integrating wave energy converter (WEC) arrays into microgrids. Specifically, an array of WECs can be physically positioned such that the incoming regular waves will produce an output emulating an N-phase AC system such that the PPN output power is constant. ESS requirements are thereby minimized whilst maintaining grid stability with high power quality. This will enable RES integration onto a future smart grid for large-scale adoption and cost reduction while preserving high efficiency, reliability, and resiliency.

Wilson, David G.↗

Factorization at subleading power and endpoint-divergent convolutions in h → γγ decay

t is by now well known that, at subleading power in scale ratios, factorization theorems for high-energy cross sections and decay amplitudes contain endpoint-divergent convolution integrals. The presence of endpoint divergences hints at a violation of simple scale separation. At the technical level, they indicate an unexpected failure of dimensional regularization and the $\overline{MS}$ subtraction scheme. In this work, we start a detailed discussion of factorization at subleading power within the framework of soft-collinear effective theory. As a concrete example, we factorize the decay amplitude for the radiative Higgs-boson decay h → γγ mediated by a b-quark loop, for which endpoint-divergent convolution integrals require both dimensional and rapidity regulators. We derive a factorization theorem for the decay amplitude in terms of bare Wilson coefficients and operator matrix elements. We show that endpoint divergences caused by rapidity divergences cancel to all orders of perturbation theory, while endpoint divergences that are regularized dimensionally can be removed by rearranging the terms in the factorization theorem. We use our result to resum the leading double-logarithmic corrections of order $α^n_sln^{2n+2}(-M^2_h/m^2_b)$ to the decay amplitude to all orders of perturbation theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Bidirectional High-Power-Quality Grid Interface With a Novel Bidirectional Noninverted Buck Boost Converter for PHEVs

Plug-in hybrid electric vehicles (PHEVs) will play a vital role in future sustainable transportation systems due to their potential in terms of energy security, decreased environmental impact, improved fuel economy, and better performance. Moreover, new regulations have been established to improve the collective gas mileage, cut greenhouse gas emissions, and reduce dependence on foreign oil. This paper primarily focuses on two major thrust areas of PHEVs. First, it introduces a grid-friendly bidirectional alternating current/direct current ac/dc dc/ac rectifier/inverter for facilitating vehicle-to-grid (V2G) integration of PHEVs. Second, it presents an integrated bidirectional noninverted buck boost converter that interfaces the energy storage device of the PHEV to the dc link in both grid-connected and driving modes. The proposed bidirectional converter has minimal grid-level disruptions in terms of power factor and total harmonic distortion, with less switching noise. The integrated bidirectional dc/dc converter assists the grid interface converter to track the charge/discharge power of the PHEV battery. In addition, while driving, the dc/dc converter provides a regulated dc link voltage to the motor drive and captures the braking energy during regenerative braking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Medium Voltage Energy Hub Based on Multilevel Cascaded H Bridge-Dual Active Bridge Back-to-Back Converter for Power Distribution Feeders Interconnection and Multiple Simultaneous Grid Services

This paper presents a medium voltage energy hub based on a modular design of a multilevel cascaded H bridge (CHB)-dual active bridge (DAB) converter. The energy hub composed of the two CHB-DAB modules with a back-to-back topology can be utilized as a grid interconnection component between distribution feeders. The energy hub can provide multiple simultaneous grid services such as voltage regulation, power factor correction, as well as active power flow control between the connected feeders, contributing to grid flexibility, efficiency, reliability, and resilience. Circuit structure and control schemes for the energy hub including both local controllers for each converter and outer loop controllers are proposed to enable simultaneous grid services with coordination to prevent the overloading of the hub. To validate the performance of the hub, the hub system is interconnected between two IEEE 4-bus feeders and provides voltage regulation for both feeders, while controlling active power flow between them. The system and the feeders are implemented in Real-Time Digital Simulator (RTDS) for real-time simulation verification.

Choi, Jongchan↗

PHIL Inverter Test Report: Analysis of High-Penetration Levels of PV into the Distribution Grid in California, March 12 - March 16, 2012

This report describes power hardware-in-the-loop simulation testing of a 500 kW Satcon photovoltaic inverter, conducted at the Center for Advanced Power Systems at Florida State University from March 12th through March 16th, 2012. Testing was led by a team from the National Renewable Energy Laboratory. The report reviews the results of data captured during the course of testing. The tests were used to demonstrate operation of and gather data from the inverter in a simulated operational environment. Testing demonstrated the ability of the inverter to operate in either a Power Factor Control Mode or a Reactive Power Command Mode, and to respond to real power limits.

14 SOLAR ENERGY↗

Photovoltaic solar system connected to the electric power grid operating as active power generator and reactive power compensator

In the case of photovoltaic (PV) systems acting as distributed generation (DG) systems, the DC energy that is produced is fed to the grid through the power-conditioning unit (inverter). The majority of contemporary inverters used in DG systems are current source inverters (CSI) operating at unity power factor. If, however, we assume that voltage source inverters (VSI) can replace CSIs, we can generate reactive power proportionally to the remaining unused capacity at any given time. According to the theory of instantaneous power, the inverter reactive power can be regulated by changing the amplitude of its output voltage. In addition, the inverter active power can be adjusted by modifying the phase angle of its output voltage. Based on such theory, both the active power supply and the reactive power compensation (RPC) can be carried out simultaneously. When the insolation is weak or the PV modules are inoperative at night, the RPC feature of a PV system can still be used to improve the inverter utilisation factor. Some MATLAB simulation results are included here to show the feasibility of the method. (author)

14 SOLAR ENERGY↗

Nanostructured thermoelectrics: the new paradigm?

This review discusses recent developments and current research in bulk thermoelectric materials in which nanostructuring is a key aspect affecting thermoelectric performance. Systems based on PbTe, AgPb{sub m}SbTe{sub 2+m}, NaPb{sub m}SbTe{sub 2+m}, Bi{sub 2}Te{sub 3}, and Si are given particular emphasis. To date the dramatic enhancements in figure of merit in bulk nanostructured materials come from very large reductions in lattice thermal conductivity rather than improvement in power factors. A discussion of future possible strategies is aimed at enhancing the thermoelectric figure of merit of these materials.

36 MATERIALS SCIENCE↗

Voltage and Current Unbalance Compensation Using a STATCOM

A three-phase insulated gate bipolar transistor (IGBT)-based static var compensator (STATCOM) is used for voltage and/or current unbalance compensation. An instantaneous power theory is adopted for real-time calculation and control. Three control schemes, current control, voltage control, and integrated control are proposed to compensate the unbalance of current, voltage, or both. The compensation results of the different control schemes in unbalance cases (load unbalance or voltage source unbalance) are compared and analyzed. The simulation and experimental results show that the control schemes can compensate the unbalance in load current or in the voltage source. Different compensation objectives can be achieved, i.e., balanced and unity power factor source current, balanced and regulated voltage, or both, by choosing appropriate control schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-temperature electrical transport behaviors in textured Ca{sub 3}Co{sub 4}O{sub 9}-based polycrystalline ceramics

Highly (00l) oriented Ca{sub 3}Co{sub 4}O{sub 9}-based ceramics were fabricated by spark plasma sintering combined with a dynamic forging process. The grain orientation is effective in lowering the electrical resistivity and enhancing the thermoelectric power factor but with little influence on the Seebeck coefficient. A metallic-to-semiconducting transition temperature can be observed and the activation energy is almost independent of the La-doping. All of the Ca{sub 3}Co{sub 4}O{sub 9}-based ceramic samples exhibit large thermoelectric power, and the figure of merit for La-doped Ca{sub 3}Co{sub 4}O{sub 9} sample can reach 0.26 at 975 K, which can be a promising candidate of p-type material for high-temperature thermoelectric application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermoelectric property study of Bi{sub 2}Te{sub 3}-Sb{sub 2}Te{sub 3} mixed crystals

Polycrystalline Bi{sub 2}Te{sub 3}-Sb{sub 2}Te{sub 3} mixed crystals are synthesized by solid state reaction method. Structural characterizations are carried out using X-Ray diffraction (XRD). Thermal variation of resistivity data, measured down to 10 K, shows that there is a transition from semiconducting to metallic behavior for 80% Sb containing sample. Temperature dependent thermopower measurement is carried out using differential technique in the temperature range 300–20 K. Thermopower data shows all the samples are p-type in nature. Power factor of the samples are also estimated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced thermoelectric figure of merit in strained Tl-doped Bi{sub 2}Se{sub 3}

We explain recent experimental findings on Tl-doped Bi{sub 2}Se{sub 3} by determining the electronic and transport properties by first-principles calculations and semi-classical Boltzmann theory. Though Tl-doping introduces a momentum-dependent spin-orbit splitting, the effective mass of the carriers is essentially not modified, while the band gap is reduced. Tl is found to be exceptional in this respect as other dopants modify the dispersion, which compromises thermoelectricity. Moreover, we demonstrate that only after Tl-doping strain becomes an efficient tool for enhancing the thermoelectric performance. A high figure of merit of 0.86 is obtained for strong p-doping (7 × 10{sup 20} cm{sup −3}, maximal power factor) at 500 K under 2% tensile strain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the crystal structure and thermoelectric properties of thin Si{sub 1–x}Mn{sub x} films

Thin (25 nm) Si{sub 1–x}Mn{sub x}/Si(100) films are fabricated by pulsed laser deposition. According to high-resolution transmission electron microscopy data, the films have a nanotextured crystalline structure and are chemically homogeneous. The temperature dependences of the resistivity and thermopower are measured in the range of 300–500 K, and the temperature dependences of the Seebeck coefficient and power factor are calculated.

36 MATERIALS SCIENCE↗

Thermoelectric Properties of Non-equilibrium Synthesized Ce0.9Fe3CoSb12 Filled Skutterudites

The authors report on the thermoelectric properties of the filled skutterudite Ce{sub 0.9}Fe{sub 3}CoSb{sub 12} prepared via non-equilibrium synthesis method. Melt-spun ribbons were directly converting into single phase polycrystalline pellets under pressure. For comparison, pellets with the same composition were also prepared using the conventional solid-state reaction followed by long term annealing. It was found that the non-equilibrium synthesized samples have higher power factors and lower thermal conductivity, leading to substantially higher figure of merit.

36 MATERIALS SCIENCE↗