Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROTOCOLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

SU-E-T-67: A Quality Assurance Procedure for VMAT Delivery Technique with Multiple Verification Metric Using TG-119 Protocol

Purpose: A successful VMAT plan delivery includes precise modulations of dose rate, gantry rotational and multi-leaf collimator shapes. The purpose of this research is to construct routine QA protocol which focuses on VMAT delivery technique and to obtain a baseline including dose error, fluence distribution and mechanical accuracy during VMAT. Methods: The mock prostate, head and neck (HN) cases supplied from AAPM were used in this study. A VMAT plans were generated in Monaco TPS according to TG-119 protocol. Plans were created using 6 MV and 10 MV photon beams for each case. The phantom based measurement, fluence measurement and log files analysis were performed. The dose measurement was performed using 0.6 cc ion chamber, which located at isocenter. The fluence distribution were acquired using the MapCHECK2 mounted in the MapPHAN. The trajectory log files recorded inner 20 leaf pairs and gantry angle positions at every 0.25 sec interval were exported to in-house software developed by MATLAB and determined those RMS values. Results: The dose difference is expressed as a ratio of the difference between measured and planned doses. The dose difference for 6 MV was 0.91%, for 10 MV was 0.67%. In turn, the fluence distribution using gamma criteria of 2%/2 mm with a 50% minimum dose threshold for 6 MV was 98.8%, for 10 MV was 97.5%, respectively. The RMS values of MLC for 6 MV and 10 MV were 0.32 mm and 0.37 mm, of gantry were 0.33 degree and 0.31 degree. Conclusion: In this study, QA protocol to assess VMAT delivery accuracy is constructed and results acquired in this study are used as a baseline of VMAT delivery performance verification.

60 APPLIED LIFE SCIENCES↗

WE-D-207-03: CT Protocols for Screening and the ACR Designated Lung Screening Program

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

SU-F-R-40: Robustness Test of Computed Tomography Textures of Lung Tissues to Varying Scanning Protocols Using a Realistic Phantom Environment

Purpose: The reliability of computed tomography (CT) textures is an important element of radiomics analysis. This study investigates the dependency of lung CT textures on different breathing phases and changes in CT image acquisition protocols in a realistic phantom setting. Methods: We investigated 11 CT texture features for radiation-induced lung disease from 3 categories (first-order, grey level co-ocurrence matrix (GLCM), and Law’s filter). A biomechanical swine lung phantom was scanned at two breathing phases (inhale/exhale) and two scanning protocols set for PET/CT and diagnostic CT scanning. Lung volumes acquired from the CT images were divided into 2-dimensional sub-regions with a grid spacing of 31 mm. The distribution of the evaluated texture features from these sub-regions were compared between the two scanning protocols and two breathing phases. The significance of each factor on feature values were tested at 95% significance level using analysis of covariance (ANCOVA) model with interaction terms included. Robustness of a feature to a scanning factor was defined as non-significant dependence on the factor. Results: Three GLCM textures (variance, sum entropy, difference entropy) were robust to breathing changes. Two GLCM (variance, sum entropy) and 3 Law’s filter textures (S5L5, E5L5, W5L5) were robust to scanner changes. Moreover, the two GLCM textures (variance, sum entropy) were consistent across all 4 scanning conditions. First-order features, especially Hounsfield unit intensity features, presented the most drastic variation up to 39%. Conclusion: Amongst the studied features, GLCM and Law’s filter texture features were more robust than first-order features. However, the majority of the features were modified by either breathing phase or scanner changes, suggesting a need for calibration when retrospectively comparing scans obtained at different conditions. Further investigation is necessary to identify the sensitivity of individual image acquisition parameters.

60 APPLIED LIFE SCIENCES↗

SU-F-T-173: One-Scan Protocol: Verifying the Delivery of Spot-Scanning Proton Beam

Purpose: Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains from one-shot irradiation for multiple depths. However, calibration can be a tedious procedure which may limit widespread use. Moreover, since there may be an energy dependence, which manifests as a depth dependence, this may require additional measurements for each patient. We present a one-scan protocol to simplify the procedure. Methods: We performed the calibration using an EBT3 film at depths of 18, 20, 24cm of Plastic Water exposed by a 6-level step-wedge plan on a Proteus Plus proton system (IBA, Belgium). The calibration doses ranged 65–250 cGy(RBE) for proton energies of 170–200MeV. A clinical prostate+nodes plan was used for validation. The planar doses at selected depths were measured with EBT3 films and analyzed using one-scan protocol (one-scan digitization of QA film and at least one film exposed to known dose). The Gamma passing rates, dose-difference maps, and profiles of 2D planar doses measured with EBT3 film, IBA MatriXX PT, versus TPS calculations were analyzed and compared. Results: The EBT3 film measurement results matched well with the TPS calculation data with an average passing rate of ∼95% for 2%/2mm and slightly lower passing rates were obtained from an ion chamber array detector. We were able to demonstrate that the use of a proton step-wedge provided clinically acceptable results and minimized variations between film-scanner orientation, inter-scan, and scanning conditions. Furthermore, it could be derived from no more than two films exposed to known doses (one could be zero) for rescaling the master calibration curve at each depth. Conclusion: The use of a proton step-wedge for calibration of EBT3 film increases efficiency. The sensitivity of the calibration to depth variations has been explored. One-scan protocol results appear to be comparable to that of the ion chamber array detector. One author has a research grant from Ashland Inc., the manufacturer of the GafChromic film.

60 APPLIED LIFE SCIENCES↗

Investigating the Particle Growth in Bimodal Pt/C Catalysts by In-Situ Small-Angle X-ray Scattering: Challenges in the Evaluation of Stress Test Protocol-Dependent Degradation Mechanisms

The influence of different combinations of accelerated stress test (AST) protocols simulating load-cycle and start/stop conditions of a proton exchange membrane fuel cell (PEMFC) vehicle is investigated on a bimodal Pt/C catalyst. The bimodal Pt/C catalyst, prepared by mixing two commercial catalysts, serves as a model system and consists of two distinguishable size populations. The change in mean particle size was investigated by in situ small-angle X-ray scattering (SAXS). The comparison to the reference catalysts, i.e., the two single-size population catalysts, uncovers the presence of electrochemical Ostwald ripening as a degradation mechanism in the bimodal catalyst. Increasing the harshness of the applied AST protocol combinations by faster changing between load-cycle or start/stop conditions, the particle size of the larger population of the bimodal catalyst increases faster than expected. Surprisingly, the change in mean particle size of the smaller size population indicates a smaller increase for harsher AST protocols, which might be explained by a substantial electrochemical Ostwald ripening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Industrial Control Systems Network Protocol Parsers

Industrial Control Systems protocol parsers plugins for the Zeek network security monitoring framework. Currently we have four fully developed protocol parsers but we plan on adding more in the future. The protocol parsers we currently have developed are for BACnet, DNP3, Ethernet/IP, and Modbus.

Rasmussen, BrettD↗

Memento Protocol Validator Software

The Memento Protocol Validator software provides a suite of tools to validate compliance with the Memento protocol. The Memento protocol is an interoperability solution for accessing web archiving information with the DateTime dimension.

Balakireva, Lyudmila↗

A holistic cyber-physical security protocol for authenticating the provenance and integrity of structural health monitoring imagery data

Modern infrastructure systems, such as bridges, dams, power generation stations, and buildings increasingly have an intrinsic cyber-physical nature to them. Infrastructure now commonly, includes actuators, network connections, sensors, control systems, and computational resources. It is of increasing concern that modern infrastructure is vulnerable to cyber-attacks that can damage both the cyber and physical nature of the infrastructure. To date, the physical and cyber health of infrastructure has been considered separately. However, the increasing concerns associated with the cyber-physical security of infrastructure coupled with the emergence of 5G networks made using components that are not universally considered trustworthy, and the emergence of techniques for creating deepfakes and adversarial examples suggests the time has come to begin considering cyber health and structural health with a more holistic approach. In this work, a protocol is developed for ensuring the imagery data captured by a structural health monitoring system can be unambiguously attributed to legitimate sensors associated with the structural health monitoring system. A computer vision approach based on the idea of mutual information is then presented to detect damage in an image. This work presents the protocol for authenticating the provenance of imager data and demonstrates that this protocol does not have overly adverse effects when used with the mutual information-based technique for detecting damage in the resulting imagery data.

Jung, HweeKwon↗

A simple and highly efficient protocol for 13 C-labeling of plant cell wall for structural and quantitative analyses via solid-state nuclear magnetic resonance

Plant cell walls are made of a complex network of interacting polymers that play a critical role in plant development and responses to environmental changes. Thus, improving plant biomass and fitness requires the elucidation of the structural organization of plant cell walls in their native environment. The 13 C-based multi-dimensional solid-state nuclear magnetic resonance (ssNMR) has been instrumental in revealing the structural information of plant cell walls through 2D and 3D correlation spectral analyses. However, the requirement of enriching plants with 13 C limits the applicability of this method. To our knowledge, there is only a very limited set of methods currently available that achieve high levels of 13 C-labeling of plant materials using 13 CO 2 , and most of them require large amounts of 13 CO 2 in larger growth chambers. In this study, a simplified protocol for 13C-labeling of plant materials is introduced that allows ca 60% labeling of the cell walls, as quantified by comparison with commercially labeled samples. This level of 13 C-enrichment is sufficient for all conventional 2D and 3D correlation ssNMR experiments for detailed analysis of plant cell wall structure. The protocol is based on a convenient and easy setup to supply both 13 C-labeled glucose and 13 CO 2 using a vacuum-desiccator. The protocol does not require large amounts of 13 CO 2 . This study shows that our 13 C-labeling of plant materials can make the accessibility to ssNMR technique easy and affordable. The derived high-resolution 2D and 3D correlation spectra are used to extract structural information of plant cell walls. This helps to better understand the influence of polysaccharide-polysaccharide interaction on plant performance and allows for a more precise parametrization of plant cell wall models.

09 BIOMASS FUELS↗

Performance of a quantum teleportation protocol based on collective spontaneous emission

Recently a conditional quantum teleportation protocol has been proposed by Chen et al. [New J. Phys. 7, 172 (2005)], which is based on the collective spontaneous emission of a photon from a pair of quantum dots. We formulate a similar protocol for collective emission from a pair of atoms, one of which is entangled with a single mode of an optical cavity. We focus on the performance of the protocol as characterized by the fidelity of the teleported state and the overall success probability. We consider a strategy employing spatially resolved photodetection of the emitted photon in order to distinguish superradiant from subradiant emission on the basis of a single detected photon. We find that fidelity approaches unity as the spacing of the atoms becomes much smaller than the emission wavelength with a success probability of 0.25. The fidelity remains above the classical limit of 2/3 for arbitrary atomic separations with the ultimate limit of performance coming from the spatial resolution of the detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The U.S. Department of Energy’s Energy Storage Systems (ESS) Program, through the support of Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL), facilitated the development of the protocol provided in this report. The focus of the protocol is to provide a uniform way of measuring, quantifying, and reporting the performance of EESs in various applications; something that does not exist today and, as such, is hampering the consideration and use of this technology in the market. The availability of an application-specific protocol for use in measuring and expressing performance-related metrics of ESSs will allow technology developers, power-grid operators and other end-users to evaluate the performance of energy storage technologies on a uniform and comparable basis. This will help differentiate technologies and products for specific application(s) and provide transparency in how performance is measured. It also will assist utilities and other consumers of ESSs make more informed decisions as they consider the potential application and use of ESSs, as well as form the basis for documentation that might be required to justify utility investment in such technologies.

Bray, Kathryn L.↗

Protocol for uniformly measuring and expressing the performance of energy storage systems.

The U.S. Department of Energy s Energy Storage Systems (ESS) Program, through the support of Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL), facilitated the development of the protocol provided in this report. The focus of the protocol is to provide a uniform way of measuring, quantifying, and reporting the performance of ESSs in various applications; something that does not exist today and, as such, is hampering the consideration and use of this technology in the market. The availability of an application-specific protocol for use in measuring and expressing performance-related metrics of ESSs will allow technology developers, power-grid operators and other end-users to evaluate the performance of energy storage technologies on a uniform and comparable basis. This will help differentiate technologies and products for specific application(s) and provide transparency in how performance is measured. It also will assist utilities and other consumers of ESSs to make more informed decisions as they consider the potential application and use of ESSs, as well as form the basis for documentation that might be required to justify utility investment in such technologies.

Ferreira, Summer Kamal Rhodes↗

Draft Plan to Develop Non-Intrusive Load Monitoring Test Protocols

This document presents a Draft Plan proposed to develop a common test protocol that can be used to evaluate the performance requirements of Non-Intrusive Load Monitoring. Development on the test protocol will be focused on providing a consistent method that can be used to quantify and compare the performance characteristics of NILM products. Elements of the protocols include specifications for appliances to be used, metrics, instrumentation, and a procedure to simulate appliance behavior during tests. In addition, three priority use cases for NILM will be identified and their performance requirements will specified.

47 OTHER INSTRUMENTATION↗

Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

This Commercial and Industrial Lighting Controls Evaluation Protocol (the protocol) describes methods to account for energy savings resulting from programmatic installation of lighting control equipment in large populations of commercial, industrial, government, institutional, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. When lighting controls are installed in conjunction with a lighting retrofit project, the lighting control savings must be calculated parametrically with the lighting retrofit project so savings are not double counted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 15: Commercial New Construction Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

This protocol is intended to describe the recommended method when evaluating the whole-building performance of new construction projects in the commercial sector. The protocol focuses on energy conservation measures (ECMs) or packages of measures where evaluators can analyze impacts using building simulation. These ECMs typically require the use of calibrated building simulations under Option D of the International Performance Measurement and Verification Protocol (IPMVP).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 22: Compressed Air Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: High-efficiency/variable speed drive (VSD) compressor replacing modulating, load/unload, or constant-speed compressor; and Compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Global Overview of Energy Storage Performance Test Protocols

As part of the World Bank Energy Storage Partnership, this document seeks to provide support and knowledge to a set of stakeholders across the developing world as we all seek to analyze the emerging opportunities and technologies for energy storage in the electric sector. As global prices for renewable energy have dropped dramatically over the last decade and continue to decline and the value of energy storage has increased in many systems, the World Bank technical teams and others have been hearing of a variety of problems. Related, developing countries have been asking a series of questions in this new area. This working group seeks to address the issues raised in part by creating this document and working to gather a variety of experts in this area from across the globe in support of the World Bank efforts. Performance testing, in combination with test beds (Working Group 2), is critical to fulfill the promise offered by these breakthrough technologies and critical to increasing trust in these systems and reducing risk. This document seeks to provide information to stakeholders in developing countries on the current global performance testing landscape of the battery (and broader) performance testing landscape. This document does that by summarizing testing protocols published by key global entities. From this summary, it can be concluded that there are several organizations within each region that set protocols for the testing and specifications of stationary energy storage systems. Across most of these entities, there are extensive protocols for testing batteries for electrical vehicles and mobile devices, but less for large scale energy storage system and their usage cases. The working group and the Partnership more generally agree that the nascent markets for certain technologies and rapid growth make testing more important than ever as these markets continue to mature. This document also seeks to provide a set of "guideposts" to new entrants by pointing out some of the key organizations globally that are currently engaged in performance testing of energy storage systems (often batteries but the larger organizations are likely to engage in tailored tests for emerging thermal and other storage technologies).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SIRFN Draft Test Protocols for Advanced Battery Energy Storage System Interoperability Functions.

IEA Implementing Agreement for International Smart Grid Action Network, a Cooperative Program on Smart Grids (ISGAN) discussion papers are meant as input documents to the global discussion about smart grids. Each is a statement by the author(s) regarding a topic of international interest. They reflect works in progress in the development of smart grids in the different regions of the world. Their aim is not to communicate a final outcome or to advise decision-makers, but rather to lay the ground work for further research and analysis. In this report, SIRFN laboratories (Sandia, AIT, RSE and FREA) establish a harmonized Battery Energy Storage System (BESS) evaluation/certification protocol for advanced energy storage functions. The authors present this standardized protocol as an adoption or revision option for jurisdictions when creating or modifying certification testing requirements. To complete this process, each laboratory shared information on national, international, and jurisdictional grid codes and standards for BESS. Based on these requirements, and BESS testing and certification literature, a broad list of interoperability functions, use cases, storage capabilities, and requirements were compiled. This list was then consolidated to a unique set of BESS functions for inclusion in the certification procedure. Draft certification protocols for five initial functions were created by the SIRFN group in order to harmonize the international effort to establish a unified set of procedures for interoperability testing of BESS.

25 ENERGY STORAGE↗