Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance, Reliability, Design, Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Design and Comparison of Cascaded H-Bridge, Modular Multilevel Converter, and 5-L Active Neutral Point Clamped Topologies for Motor Drive Applications

This paper presents the design procedure and comparison of converters currently used in medium-voltage high-power motor drive applications. For this purpose, the cascaded H-bridge (CHB), modular multilevel converter (MMC), and five-level active neutral point clamped (5-L ANPC) topologies are targeted. The design is performed using 1.7-kV insulated gate bipolar transistors (IGBTs) for CHB and MMC converters, and utilizing 3.3- and 4.5-kV IGBTs for 5-L ANPC topology as normally done in industry. The comparison is done between the designed converter topologies at three different voltage levels (4.16, 6.9, and 13.8 kV, with only the first two voltage levels in case of the 5-L ANPC) and two different power levels (3 and 5 MVA), in order to elucidate the dependence of different parameters on voltage and power rating. Finally, the comparison is done from several points of view such as efficiency, capacitive energy storage, semiconductor utilization, parts count (for measure of reliability), and power density.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fluorinated ionic liquids as gas chromatographic stationary phases for the separation of volatile per- and polyfluoroalkyl substances

Background Here, the production of fluorinated organic compounds in the manufacturing, semiconductor, and pharmaceutical industries has increased exponentially over the past decade. This rapid growth has created an urgent need for efficient chromatographic platforms capable of selectively separating these compounds from complex mixtures, not only to support industrial quality control and waste management practices, but also to enable reliable environmental monitoring of volatile fluorinated contaminants. Conventional GC stationary phases lack the fluorophilic interactions needed for highly fluorinated analytes. Consequently, there is a clear demand for specialized stationary phases designed to improve chromatographic retention and selectivity for these compounds. Results Three stationary phases composed of fluorinated ionic liquids (ILs) with varied extent of fluorination were prepared to study fluorophilic interactions with fluorinated/non-fluorinated probe molecules by gas chromatography (GC). IL stationary phases featuring linear and branched perfluoroalkyl moieties, as well as a branched alkyl moiety, were systematically investigated. Chromatographic performance was examined using fluorinated compounds and their hydrocarbon analogs, including CF 3 -substituted aromatics, aliphatic alcohols, fluorotelomer alcohols (FTOHs), and perfluoroalkenes. Measurements on 5 m and 20 m columns revealed that the IL possessing branched alkyl provided stronger dispersive and hydrogen bonding interactions toward non-fluorinated aromatic and long-chain alcohols, whereas the fluorinated ILs enhanced retention of highly fluorinated FTOHs and perfluorodecene. Comprehensive two-dimensional GC (GC × GC), using a nonpolar primary column coupled with secondary columns featuring cross-bonded poly(trifluoropropylmethyl siloxane) (Rtx-200 ms), the branched fluorinated IL, or the branched non-fluorinated IL, highlighted complementary selectivity with the branched fluorinated IL providing the strongest interactions with fluorinated analytes. Significance These results demonstrate that fluorinated IL stationary phases are promising alternatives to conventional polysiloxane stationary phases for improving the separation of per- and polyfluoroalkyl substances and related fluorinated compounds. By correlating IL structure with fluorophilic interactions, this work establishes design principles for GC stationary phases that enable enhanced selectivity for highly fluorinated analytes while maintaining complementary interactions with non-fluorinated compounds.

Comprehensive two-dimensional GC↗

Frameless Angiogram-Based Stereotactic Radiosurgery for Treatment of Arteriovenous Malformations

Purpose: Stereotactic radiosurgery (SRS) is an effective alternative to microsurgical resection or embolization for definitive treatment of arteriovenous malformations (AVMs). Digital subtraction angiography (DSA) is the gold standard for pretreatment diagnosis and characterization of vascular anatomy, but requires rigid frame (skull) immobilization when used in combination with SRS. With the advent of advanced proton and image-guided photon delivery systems, SRS treatment is increasingly migrating to frameless platforms, which are incompatible with frame-based DSA. Without DSA as the primary image, target definition may be less than optimal, in some cases precluding the ability to treat with a frameless system. This article reports a novel solution. Methods and Materials: Fiducial markers are implanted into the patient's skull before angiography. Angiography is performed according to the standard clinical protocol, but, in contrast to the previous practice, without the rigid frame. Separate images of a specially designed localizer box are subsequently obtained. A target volume projected on DSA can be transferred to the localizer system in three dimensions, and in turn be transferred to multiple CT slices using the implanted fiducials. Combined with other imaging modalities, this 'virtual frame' approach yields a highly precise treatment plan that can be delivered by frameless SRS technologies. Results: Phantom measurements for point and volume targets have been performed. The overall uncertainty of placing a point target to CT is 0.4 mm. For volume targets, deviation of the transformed contour from the target CT image is within 0.6 mm. The algorithm and software are robust. The method has been applied clinically, with reliable results. Conclusions: A novel and reproducible method for frameless SRS of AVMs has been developed that enables the use of DSA without the requirement for rigid immobilization. Multiple pairs of DSA can be used for better conformality. Further improvement, including using nonimplanted fiducials, is potentially feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IPC-Fusion (Infrastructure Perception and Control (IPC): Multisensor Data Fusion Software) [SWR-25-153]

As part of the National Laboratory of the Rockies' (NLR’s) Infrastructure Perception and Control Laboratory, the IPC-Fusion toolkit provides a probabilistic, scalable, multi-sensor fusion framework that integrates (late-stage fusion) heterogeneous object detection data from traffic sensors to enable robust, real-time tracking of roadway occupants. The algorithmic design of the toolkit is motivated by the need for creating a digital twin of traffic at the edge in a scalable and affordable manner. The software operates by combining object-level measurements (such as position and velocity) from a suite of sensors (such as radar, lidar, camera) using Kalman filtering and probabilistic data association techniques to overcome individual sensor limitations and achieve superior tracking performance in complex traffic zones. The framework addresses key challenges including heterogeneous measurement uncertainties, asynchronous data streams, varying spatiotemporal data resolutions, robust data association, and adaptive object lifecycle management. Validated on real-world traffic intersection data including vehicles and pedestrians, IPC-Fusion demonstrates enhanced tracking reliability across scenarios involving occlusions, sensor failures, and varying traffic densities, supporting the broader IPC initiative's goal of transforming transportation infrastructure through advanced perception capabilities for intelligent transportation systems, traffic safety applications, and autonomous vehicle support.

Sandhu, Rimple [National Laboratory of the Rockies↗

Liquid X-ray diffraction on the NIF: Phase transitions into and within the liquid phase

Traditional Hugoniot velocity measurements have always been severely limited in their ability to determine structural properties of materials. However, the advent of x-ray diffraction1 on laser compression experiments is recently allowing unprecedented opportunities to directly measure the in-situ structure of compressed materials. Unfortunately, much of the phase space accessible to shock compression in general and on the NIF specifically is in the liquid or fluid phases, so that traditional Bragg diffraction cannot be used. This proposal seeks beam time to address this issue by developing a reliable capability for liquid diffraction on the NIF. There are currently three primary applications of liquid x-ray diffraction in highpressure science. First, the substitution of liquid diffuse scattering for Bragg scattering is the preferred method for documenting melting in laser-heated DAC experiments.2-4 Second, the search for and observation of liquid-liquid phase transitions requires a direct structural diagnostic.5 And finally, great progress has been achieved in measuring static-high-pressure liquid diffraction in diamond-anvil cells (DACs) in the past decade. We propose to use our recent successes on Omega and Omega EP on diffraction of iron and diamond to 5 Mbar to design and perform our NIF experiments. The critical advance in these experiments is the use of a diamond-sandwich target.

42 ENGINEERING↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Design, testing and emplacement of sand-bentonite for the construction of a gas-permeable seal test (gast)

The main aim of a gas-permeable seal is to increase the gas transport capacity of the backfilled underground structures without compromising the radionuclide retention capacity of the engineered barrier system or the host rock. Such a seal, proposed by NAGRA as part of the 'Engineered Gas Transport System' in a L/ILW repository, considers specially designed backfill and sealing materials such as sand/bentonite (S/B) mixtures with a bentonite content of 20- 30%. NAGRA's RD and D plan foresees demonstrating the construction and performance of repository seals and improving the understanding and the database for reliably predicting water and gas transport through these systems. The fluid flow and gas transport properties of these backfills have been determined at the laboratory scale and through modelling the maximum gas pressures in the near field of a repository system and the gas flow rates have been evaluated. Within this context, the Gas-permeable Seal Test (GAST) was constructed at Grimsel Test Site (GTS) to validate the effective functioning of gas-permeable seals at realistic scale. The intrinsic permeability of such seals should be in the order of 10-18 m2. Because the construction of S/B seals is not common practice for construction companies, a stepwise approach was followed to evaluate different construction and quality assurance methods. As a first step, an investigation campaign with simple tests in the laboratory and in the field followed by 1:1 scale pre-tests at GTS was performed. Through this gradual increase of the degree of complexity, practical experience was gained and confidence in the methods and procedures to be used was built, which allowed reliably producing and working with S/B mixtures at a realistic scale. During the whole pre-testing phase, a quality assurance (QA) programme for S/B mixtures was developed and different methods were assessed. They helped to evaluate and choose appropriate emplacement techniques and methodologies to achieve the target S/B dry density of 1.70 g/cm{sup 3}, which results in the desired intrinsic permeability throughout the experiment. The final QA methodology was targeted at engineering measures to decide if the work can proceed, and at producing high resolution material properties database for future water and gas transport modelling activities. The different applied QA techniques included standard core cutter tests, the application of neutron-gamma (Troxler) probes and two mass balance methods (2D and 3D). The methods, looking at different representative scales, have provided only slightly different results and showed that the average density of the emplaced S/B plug was between 1.65 and 1.73 g/cm{sup 3}. Spatial variability of dry densities was observed at decimeter scale. Overall, the pre-testing and QA programme performed for the GAST project demonstrated how the given design criteria and requirements can be met by appropriately planning and designing the material emplacement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapidly Assessing the Quality of Targeted Proteomics Experiments through Monitoring Stable-Isotope Labeled Standards

Selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), is a data acquisition technique used in targeted analysis of molecules, including targeted proteomic studies. It exploits the unique capability of triple-quadrupole (QQQ) mass spectrometers to monitor the predefined precursor and fragment ion pairs of specific molecules of interest throughout a liquid chromatography (LC) elution profile. Compared to shotgun proteomics, targeted proteomics using SRM has high selectivity, high sensitivity, and a wide linear dynamic range,(1-3) which makes it especially useful in the accurate and reproducible quantification of low-abundance proteins in highly complex biological samples. SRM has been widely used in the fields of biomarker discovery,(4-7) analysis of protein post-translational modifications(8) and characterization of biological protein networks.(4,9) In the recent years, multiple technical advances have greatly improved the throughput of SRM analyses, allowing for the quantification of hundreds of peptides in a single analysis.(6,7,10) For example, a single 800-plex SRM assay (e.g., 400 unlabeled and heavy-labeled peptide pairs and 2400 transitions with retention time scheduling) using ultrahigh-performance liquid chromatography (UHPLC) has been developed to quantify proteins in plasma.(11) Advanced labeling techniques utilizing in vitro proteome-assisted MRM for protein absolute quantification (iMPAQT) demonstrated the capability of SRM in genome-wide protein quantification of over 18?000 human proteins.(12) Moreover, the scan speed of QQQ instrumentation has been greatly improved in recent releases of commercial instrumentation. The newly developed TSQ Altis (released in 2017) can scan more than 600 transitions per second, which is 6 times more than a traditional QQQ scan speed of 100 transitions per second. The breadth of measurement enabled by these technological improvements to QQQ mass spectrometry has increased the feasibility and popularity of large scale targeted proteomics studies,(13) a major application of which will be in clinical studies in which up to hundreds of protein candidates need to be quantified in hundreds of clinical specimens.(14) Quantitative accuracy is a primary motivating factor for utilizing a targeted proteomics protocol. The precise and reproducible absolute quantification produced by SRM assays is essential to many clinical and laboratory experiments.(15,16) Because the abundance of an endogenous peptide is calculated from the measurement of the spiked-in reference standard, it is essential to assess the data quality of these references.(17) In early applications of targeted proteomics, when instrument speed greatly limited the number of transitions that could be monitored, much of this quality assessment was done manually. However, recent improvements in instrument performance and experimental design have enabled a dramatic increase in the number of target peptides and associated SRM transitions, which makes manual quality assessment an untenable and laborious task. A variety of computational tools assist in SRM experiment design and data analysis. The first task in creating an SRM experiment is the choice of proteins and representative peptides to monitor. Achieving a reliable protein abundance requires appropriately choosing peptides that have a strong signal and are free from interferences in the biological matrix. Numerous computational tools exist to facilitate assay design by identifying peptides and refining SRM transitions.(18-21) To help share these assays and eliminate time spent designing the same transitions at multiple institutions, community portals have begun to host well-designed and vetted assays.(22-24) Analyzing the experimental data requires significant computational effort to align files across replicates and experimental conditions, pick peaks and produce quantitative values, normalize data and perform statistical tests, etc.(25-27)

Gibbons, Bryson C.↗

Bio-Inspired Energy-Efficient Nanofabricated Electrical Contacts

Nanoscale electrical contacts, especially those between materials of dissimilar electronic properties, often represent one of the main causes of drops in energy transfer efficiency. They are also among the sources of above-threshold noise, and their performance often decreases over the lifetime of the nanodevices. Scale-down limitations from mesoscopic to nanoscale devices, and likewise, of nanoscale to quantum-scale devices are also impeded by contacts’ quality. Making more reliable, energy-efficient electrical contacts is among the goals of the nanoelectronics research within the framework of energy-efficient electronic systems. This report focuses on the design, nanofabrication, and testing of novel shapes of electrical contacts. Lithography and nanofabrication were utilized to mimic the approximate shape of insect setae for mesoscale contacts design. The contacts are tested for elementary charge transport via I–V curves and for the broadband, 1/f noise. Tests show that contacts design leads to a measurable decrease in the energy necessary to operate a contact as a switch by at least 12–20%, depending on temperature, while broadband noise shows measurably lower power spectra, for bio-inspired contacts. The proposed method is open to modifications and improvements as required by various on-chip applications.

36 MATERIALS SCIENCE↗

Advanced Power Electronics and Electric Machines

The advanced power electronics and electric machines (APEEM) research group at the National Renewable Energy Laboratory (NREL) has developed world-class experimental and modeling capabilities for designing and evaluating efficient and reliable power electronics and electric machines thermal management systems. They also design, fabricate and characterize advanced power electronics packaging, and are developing state-of-health monitoring techniques. These researchers deliver safe, reliable, high performing, power-dense components that allow seamless integration between renewable energy sources, electric transportation, and the grid, helping to make widespread electric vehicle (EV) adoption and greenhouse gas emissions reduction more feasible. This document outlines the group's major capabilities in the areas of power electronics; module development and characterization; thermal modeling and management; thermomechanical reliability analysis of devices, modules, inverters/converters, and electric machines; physics-of-failure-based reliability analysis; and microelectronics. It also overviews the group's state-of-the-art equipment for fluid-based thermal management; thermal measurement & characterization; thermomechanical reliability analysis; micro- and power electronics measurement & characterization; and prototype fabrication, as well as the group's world-class modeling and simulation capabilities.

advanced gate drivers↗

Measurement of mechanical and fracture properties of solid electrolyte interphase on lithium metal anodes in lithium ion batteries

Mechanical integrity of the solid electrolyte interphase (SEI) plays an essential role in determining the life and performance of lithium-ion batteries. Fracture and continued formation of the SEI contribute to consumption of lithium, drying of electrolyte, increase in impedance, and growth of dendrites resulting in capacity fade and premature failure. Electrolyte additives such as fluoroethylene carbonate (FEC) have been known to improve performance, but the underlying reasons have been elusive. Despite its importance, reliable methods for mechanical characterization of SEI have been lacking. In this paper, we present a new experimental technique that combines atomic force microscopy and membrane-bulge configuration to accurately measure the stress-strain behavior of SEI, including the onset of inelastic response and evolution of fracture. We characterize the SEI formed with two ethylene carbonate-based electrolytes, without and with fluoroethylene carbonate (FEC) additive. The measurements show a striking contrast; SEI with FEC additive has 80% higher elastic modulus and a vastly higher resistance to fracture. These findings offer a mechanical-behavior based rationale to understand how SEI controls battery performance. Moreover, the experimental technique offers a robust diagnostic tool to design electrolytes that can form SEI with the desired mechanical properties for optimal battery performance.

25 ENERGY STORAGE↗

An alternative electrode design for accurate spectral induced polarization measurements in variably saturated porous media

SUMMARY Applications of spectral induced polarization (SIP) require electrodes that maintain hydrologic contact with surrounding soils to capture small electrical responses, often observed as phase shifts in milliradians. For unsaturated soils, electrodes must overcome increased electrical contact impedance due to reduced pore fluid. Traditional designs use a ceramic membrane electrode (CME) with a water reservoir and metal conductor, requiring periodic maintenance to retain electrolytic solution. For field applications where maintenance is impractical, alternative designs are needed. This study evaluated a new electrode design (silica flour electrode, SFE) alongside a CME. SFEs use packed silica flour to store water via capillary forces against a metal conductor. This study examined both designs in three variably saturated soils at soil suctions up to 700 mbar and soil water contents below 1 percent, with SIP measurements across 0.01 to 10 000 Hz frequencies. SFEs match CMEs at high frequencies and perform better at lower frequencies, without requiring ongoing maintenance, making them ideal for field use. In water-only experiments, CMEs produced errors and high noise below 1.5 Hz, whereas SFEs were more accurate. However, CMEs performed better above 300 Hz. In fine sand, SFEs performed better due to the relatively lower contact impedance as compared to CMEs. Both electrode types performed comparably in silty sand and silt loam soils, although CMEs required ongoing maintenance, suggesting potential for long-term reliability issues.

58 GEOSCIENCES↗

Viscoelastic Material Characterization and Modeling of Photovoltaic Module Packaging Materials for Direct Finite-Element Method Input

Numerical tools, such as the finite-element method, are increasingly used to design and evaluate the photovoltaic (PV) modules, providing for the reduction of development time and improved performance and reliability. However, high-fidelity material models are necessary to accurately model the complex structural behavior of the involved packaging materials. A common simplification used in recent years is to model the polymer materials (i.e., encapsulant and backsheet) as linear elastic, which will lead to inaccurate results. Therefore, in this work, we present a thorough characterization of the time- and temperature-dependent mechanical response of predominant PV module encapsulant and backsheet materials. Based on this material characterization, we developed and experimentally validated generalized Maxwell models to describe each material's viscoelastic response. In addition, we included measurements of the coefficient of thermal expansion and presented all material models in such a fashion for direct input into commercial finite-element method modeling software.

FEM↗

GAMMA-PULSE-HEIGHT EVALUATION OF A USA SAVANNAH RIVER SITE BURIAL GROUND SPECIAL CONFIGURATION WASTE ITEM

The Savannah River Site (SRS) Burial Ground had a container labeled as Box 33 for which they had no reliable solid waste stream designation. The container consisted of an outer box of dimensions 48-inch x 46-inch x 66-inch and an inner box that contained high density and high radiation dose material. From the outer box Radiation Control measured an extremity dose rate of 22 mrem/h. With the lid removed from the outer box, the maximum dose rate measured from the inner box was 100 mrem/h extremity and 80 mrem/h whole body. From the outer box the material was sufficiently high in density that the Solid Waste Management operators were unable to obtain a Co-60 radiograph of the contents. Solid Waste Management requested that the Analytical Development Section of Savannah River National Laboratory perform a {gamma}-ray assay of the item to evaluate the radioactive content and possibly to designate a solid waste stream. This paper contains the results of three models used to analyze the measured {gamma}-ray data acquired in an unusual configuration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Power Distribution System Management With a Locally Connected Communication Network

Coordinated optimization and control of distribution-level assets can enable a reliable and optimal integration of massive amount of distributed energy resources (DERs) and facilitate distribution system management (DSM). Accordingly, the objective is to coordinate the power injection at the DERs to maintain certain quantities across the network, e.g., voltage magnitude, line flows, or line losses, to be close to a desired profile. By and large, the performance of the DSM algorithms has been challenged by two factors: i) the possibly non-strongly connected communication network over DERs that hinders the coordination; ii) the dynamics of the real system caused by the DERs with heterogeneous capabilities, time-varying operating conditions, and real-time measurement mismatches. In this paper, we investigate the modeling and algorithm design and analysis with the consideration of these two factors. In particular, a game theoretic characterization is first proposed to account for a locally connected communication network over DERs, along with the analysis of the existence and uniqueness of the Nash equilibrium (NE) therein. To achieve the equilibrium in a distributed fashion, a projected-gradient-based asynchronous DSM algorithm is then advocated. The algorithm performance, including the convergence speed and the tracking error, is analytically guaranteed under the dynamic setting. In conclusion, extensive numerical tests on both synthetic and realistic cases corroborate the analytical results derived.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methods—Meso-Scale Electrodes for Characterizing Diffusion-Reaction Properties of Redox-Active Organics in Viscous Electrolytes

Deep Eutectic Solvents (DESs) have recently gained interest as flow battery electrolytes. Their advantages include a wider electrochemical stability window compared to aqueous electrolytes, higher solubility for redox-active species, and negligible volatility. However, DESs are often highly viscous, and suffer from low ionic conductivities. This can make assessing redox kinetics difficult when attempting to determine their viability for energy storage. In classical voltammetric measurements, low ionic conductivity manifests as high solution resistance, thereby requiring "live" compensation of the electrolyte ohmic drop when performing fast-scan voltammetry. An uncompensated or inadequately-compensated ohmic drop leads to misinterpretation of the voltammetric behavior, e.g., assessing reversibility vs. irreversibility of a redox reaction. Here, we present micro-fabricated electrodes as facile "meso-scale" electrodes, which overcome these issues by nearly eliminating the ohmic drop while retaining uniformity of the current distribution over the electrode surface. Their use in precise transport-kinetics measurements is demonstrated using a redox-active organic, i.e., 4-Hydroxy-TEMPO in an aqueous medium and in ethaline, which is a viscous DES. This study provides a methodical approach to design and to implement voltammetry experiments using meso-scale electrodes leading to reliable measurements of diffusion-reaction properties of 4-Hydroxy-TEMPO.

25 ENERGY STORAGE↗

Photon Beamlines and Diagnostics at LCLS

The Linac Coherent Light Source (LCLS) is the first hard-x-ray free electron laser in operation. The turn-on of LCLS was rapid and operation has been reliable. Performance has exceeded the design parameters in several areas. The photon energy output covers a range from 480 eV to over 9 keV; the pulse energy is typically 2-3 mJ, with a maximum of 4 mJ at 2 keV. Electron pulse lengths can be varied from 500 fs to shorter than 10 fs. A low-charge option at 20 pC is being explored, which delivers pulses shorter than 10 fs with a reduced pulse energy, typically around 0.2 mJ. On-demand, single-shot and multi-shot modes up to 60 Hz (planned is 120 Hz) can be made available. The photon diagnostics built for LCLS have been commissioned and provide measurements of various properties of the FEL beam, such as pulse energy, beam size and position, wavelength, and allows for intensity attenuation over the entire wavelength range. The two soft x-ray instruments, the Atomic Molecular and Optics (AMO) and Soft X-ray Material Science (SXR) stations, are fully operational and completed their second user run in mid September 2010. The third user run is scheduled from October to December 2010, and will include the first hard x-ray instrument X-ray Pump-and-Probe (XPP). Three additional hard x-ray stations will follow: CXI (Coherent X-ray Imaging) is planned to start commissioning in December 2010, the XCS (X-ray correlation spectroscopy) instrument will start in June 2011, and the station for Matter in Extreme Conditions (MEC) in 2012. A list of past and future milestones for LCLS commission and operations is shown in table 1. The LCLS hard x-ray Free Electron Laser at SLAC reported first lasing in April of 2009. Since then two successful user runs have been completed at the two soft x-ray stations. The first hard x-ray station has started commissioning in July of 2010. Beam diagnostics play an essential role for tuning the machine and delivering the requested beam properties to the users. An overview of the LCLS photon diagnostics will be presented including some selected commissioning results. Plans for future improvements and upgrades will be briefly discussed.

43 PARTICLE ACCELERATORS↗

Development of Analysis Methods that Integrate Numeric and Textual Equipment Reliability Data

Within the Light Water Reactor Sustainability (LWRS) program, the Risk-Informed Systems Analysis (RISA) Pathway is performing collaborative research on the development and deployment of technologies designed to assist operating nuclear power plants (NPPs) to reduce operating costs improve plant reliability and availability. One of the RISA research areas is focusing on the development of methods and tools designed to optimize plant operations (e.g., maintenance/replacement schedules, optimal maintenance postures for plant structures, systems, and components [SSCs]) in a manner that is more cost effective than current approaches and makes better use of available SSC health data. The Risk-Informed Asset Management (RIAM) project targets this research area by creating a direct bridge between component equipment reliability (ER) data and system engineer decision making regarding maintenance activity scheduling and component aging management. In this respect, one challenge that NPP system engineers are facing is that the amount of ER data being continuously generated is not only extremely large in size, but it comes in different forms: textual (e.g., condition or maintenance reports) and numeric (e.g., generated by monitoring systems). All these data elements provide them with valuable insights and information regarding: 1) the discovery of anomalous behaviors or degradation trends, 2) the identification of the possible causes behind such behaviors/trends, and 3) the prediction of their direct consequences. However, several challenges have proved to be roadblocks to this process. While some of these challenges are technical in nature (i.e., data are often distributed over several physical servers/databases), others are conceptual in nature: data elements come in different formats (e.g., numeric or textual), and measured values have different scales (e.g., vibration spectra and oil temperature). The activities performed by the RIAM project during FY23 directly tackles the need to simultaneously integrate the analysis of ER data in all its forms, numeric and textual. Note that such task has never been performed before due to the complexity of the systems under consideration but, most importantly, because of the technical challenges behind the harmonization of ER data formats and the lack of adequate computational methods to analyze them. Our approach borrows ideas and concepts from the medical field where integration of several data sources is vital to assist medical practitioners to perform correct diagnosis and indicate optimal treatments. In our view a NPP asset is equivalent to a patient in a medical context. The main difference is the complexity of a human body is a magnitude more complex when compared to typical assets commonly present in NPPs (e.g., centrifugal pumps, or motor operated valves). This simplifies our first requirement when analyzing heterogenous ER data formats: to put data into “context”. Context is here intended as the additional piece of information that is needed by ER data analysis tools to understand what these data elements are referring to, i.e., which king of knowledge they are generating. In our context, this knowledge can be translated into models that capture the form and functional architecture of assets/systems, their dependencies, and how they interact. These models actually emulate the knowledge that that NPP system engineers possess about assets and systems; this is their key of success when analyzing ER data, their challenge is ability to handle large amount of data. Here, we employ model-based system engineering (MBSE) models of systems and assets to represent and capture their architecture and functional, i.e. cause-effect, relations. Then, ER data elements are processed by identifying first of all which elements of the developed MBSE elements they are referring to. For numeric ER data this task is fairly easy since it is possible to precisely pinpoint what MBSE elements the corresponding sensor are observing (e.g., bearing temperature of a centrifugal pump). Task is much harder for textual data since the information contained in issue or maintenance reports needs to “be understood” by a computational tool. Here we called this process as “knowledge extraction”. Once again, we borrow the experience in the medical field where methods to extract knowledge from textual data have been developed in the past decade. The missing element for us is the availability of a complete dictionary of NPP related concepts (in addition to the MBSE models presented earlier) that can put “text into context”. In FY23, such dictionary has been developed along with all the computational elements required for knowledge extraction. Lastly, once numeric and textual ER data elements have been processed and “understood”, then the last step is the discovery of possible cause-effect relations among them. This is performed by observing if a logical connection through the MBSE models exists, and if the

97 MATHEMATICS AND COMPUTING↗