Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

CONTROLLING ENERGY STORAGE SYSTEMS: LESSONS LEARNED FROM THE WASHINGTON CLEAN ENERGY FUND DEMONSTRATION PROJECTS

Washington Clean Energy Fund energy storage demonstration projects created opportunities for learning many aspects of Energy Storage Systems (ESS) including its control for economic operation. PNNL, as the lead for use case analytics program for the demonstration projects, had the opportunity to experience practical aspects of ESS control in terms of control strategy development, control systems deployment, and performance of ESS during actual operation. This paper presents some of those learning opportunities availed to date and a few key lessons with an intention to benefit the wider energy storage community.

Washington CEF, ESS control strategy, control syst↗

Wellbore integrity assessment with casing-based advanced sensing

Wellbore integrity is of paramount importance to subsurface resource extraction, energy storage 1 and waste disposal. After installation, well casing and cement are subject to mechanical stress due to near-well pressure changes and fluid induced corrosion. This is exacerbated for geothermal wells where produced fluid is at high temperature and corrosive. The current state-of-the-art technologies for wellbore integrity assessments are an array of cased hole logging tools. Wireline deployed acoustic, electromagnetic and mechanical tools are all available to inspect steel casing corrosion and casing-cement bond and these tools can provide high-resolution assessment of borehole conditions. They are intrusive, however, in terms of borehole preparation and interruption to the normal operation of the wells, and not suitable for high temperature or highly deviated well deployments. In addition, these measurements are performed infrequently due to high cost, and are therefore incapable of providing frequent data to better predict borehole degradation trajectory, which can help provide early warning of potential borehole failures. For this project we are developing a suite of novel, non-invasive, casing based tools for wellbore integrity assessment, combining fast/low cost screening with higher-precision investigation. Our approach is based on monitoring the response of the casing when energized at the wellhead, thereby interrogating the casing without well intervention. Lab, field and numerical approaches are used in our study. During the early stage of the research, we focus on numerical simulations, which have shown the sensitivity of the low frequency electromagnetic (EM) signals to changes in borehole depths and have successfully tested the concept at a field site with different length well casings. Initial seismic modeling efforts have also demonstrated our capability to simulate seismic tube wave and seismic field alterations due to borehole breakage and associated fluid leakage. Further numerical, laboratory and field experiments are underway for additional technology sensitivity analysis, particularly the transient EM/Seismic reflectometry methods, data acquisition optimization, and numerical simulation improvements.

Wilt, Michael↗

An Efficient Three-Dimensional CFD-Based Numerical Wave Tank for a Wave Energy Converter in Extreme Irregular Waves: Preprint

A numerical wave tank approach for computational fluid dynamics (CFD) modelling of an extreme irregular seastate is presented. The technique couples a potential flow solution with a CFD solver for more efficient numerical predictions. This method has recently become attractive both for the research community and the industry working with offshore structures. The model is used to determine the response of a submerged pressure differential wave energy converter (WEC) in a fully nonlinear irregular wave condition using the high fidelity CFD code, STAR-CCM+. Potential flow based numerical models are commonly used to predict motions and performance of wave energy converters. Wave kinematics can deviate from potential flow predictions for extreme wave conditions; the excitation loads on an absorber can also be increasingly influenced by viscous effects, not captured in engineering level models. In these extreme conditions, a Reynolds-averaged Navier-Stokes CFD model can better predict motions and loads for a WEC. Long time series with varying random seed numbers can be used to identify singular extreme wave events from a stochastic irregular sea state. This approach simulates a more realistic wave series for a given sea state than a regular wave or a focused wave. However, it is computationally infeasible to run these long time series for three-dimensional (3D) CFD simulations. In this work, two-dimensional (2D) CFD simulations with a long domain allow the full development of an extreme nonlinear wave condition. The results are used to identify extreme events from a 50-year storm condition for the PacWave site off the coast of Oregon. A relatively short time window including this extreme event is then mapped to a 3D simulation using a user defined wave methodology. Convergence studies for domain length, wave forcing lengths, and time before the extreme event were conducted.

cfd↗

Precision Measurement of the Neutron $d_{2}$ : A Probe of the Color Force

The $g_2$ nucleon spin-dependent structure function measured in electron deep inelastic scattering contains information beyond the simple parton model description of the nucleon. It provides insight into quark-gluon correlations and a path to access the confining local color force a struck quark experiences just as it is hit by the virtual photon due to the remnant di-quark. The quantity $d_2$, a measure of this local color force, has its information encoded in an $x^2$ weighted integral of a linear combination of spin structure functions $g_1$ and $g_2$ and is dominated by the valence-quark region at large momentum fraction $x$. To date, theoretical calculations and experimental measurements of the neutron $d_2$ differ by about two standard deviations. As a result, JLab experiment E06-014, performed in Hall A, made a precision measurement of this quantity. Double spin asymmetries and absolute cross-sections were measured in both DIS and resonance regions by scattering longitudinally polarize electrons at beam energies of 4.74 and 5.89 GeV from a longitudinally and transversely polarized $^3$He target. Preliminary results for the absolute cross-sections and spin structure functions on $^3$He will be presented as well as preliminary results for $d_2$ on $^3$He.

Posik, Matthew↗

Assessment of task‐based performance from five clinical DBT systems using an anthropomorphic breast phantom

Purpose Digital breast tomosynthesis (DBT) is a limited‐angle tomographic breast imaging modality that can be used for breast cancer screening in conjunction with full‐field digital mammography (FFDM) or synthetic mammography (SM). Currently, there are five commercial DBT systems that have been approved by the U.S. FDA for breast cancer screening, all varying greatly in design and imaging protocol. Because the systems are different in technical specifications, there is a need for a quantitative approach for assessing them. In this study, the DBT systems are assessed using a novel methodology with an inkjet‐printed anthropomorphic phantom and four alternative forced choice (4AFC) study scheme. Method A breast phantom was fabricated using inkjet printing and parchment paper. The phantom contained 5‐mm spiculated masses fabricated with potassium iodide (KI)‐doped ink and microcalcifications (MCs) made with calcium hydroxyapatite. Images of the phantom were acquired on all five systems with DBT, FFDM, and SM modalities where available using beam settings under automatic exposure control. A 4AFC study was conducted to assess reader performance with each signal under each modality. Statistical analysis was performed on the data to determine proportion correct (PC), standard deviations, and levels of significance. Results For masses, overall detection was highest with DBT. The difference in PC was statistically significant between DBT and SM for most systems. A relationship was observed between increasing PC and greater gantry span. For MCs, performance was highest with DBT and FFDM compared to SM. The difference between PC of DBT and PC of SM was statistically significant for all manufacturers. Conclusions This methodology represents a novel approach for evaluating systems. This study is the first of its kind to use an inkjet‐printed anthropomorphic phantom with realistic signals to assess performance of clinical DBT imaging systems.

Ikejimba, Lynda C.↗

A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction

Purpose: Partial volume effect (PVE) plays an important role in both qualitative and quantitative PET image accuracy, especially for small structures. A previously proposed voxelwise PVE correction method applied on PET reconstructed images involves the use of Lucy–Richardson deconvolution incorporating wavelet-based denoising to limit the associated propagation of noise. The aim of this study is to incorporate the deconvolution, coupled with the denoising step, directly inside the iterative reconstruction process to further improve PVE correction. Methods: The list-mode ordered subset expectation maximization (OSEM) algorithm has been modified accordingly with the application of the Lucy–Richardson deconvolution algorithm to the current estimation of the image, at each reconstruction iteration. Acquisitions of the NEMA NU2-2001 IQ phantom were performed on a GE DRX PET/CT system to study the impact of incorporating the deconvolution inside the reconstruction [with and without the point spread function (PSF) model] in comparison to its application postreconstruction and to standard iterative reconstruction incorporating the PSF model. The impact of the denoising step was also evaluated. Images were semiquantitatively assessed by studying the trade-off between the intensity recovery and the noise level in the background estimated as relative standard deviation. Qualitative assessments of the developed methods were additionally performed on clinical cases. Results: Incorporating the deconvolution without denoising within the reconstruction achieved superior intensity recovery in comparison to both standard OSEM reconstruction integrating a PSF model and application of the deconvolution algorithm in a postreconstruction process. The addition of the denoising step permitted to limit the SNR degradation while preserving the intensity recovery. Conclusions: This study demonstrates the feasibility of incorporating the Lucy–Richardson deconvolution associated with a wavelet-based denoising in the reconstruction process to better correct for PVE. Future work includes further evaluations of the proposed method on clinical datasets and the use of improved PSF models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid Reflective Facet Characterization Using Fringe Reflection Techniques

Reflective mirror facets for concentrating solar power (CSP) systems have stringent requirements on the surface slope accuracy in order to provide adequate system performance. This paper presents a tool that can fully characterize facets quickly enough for 100% inspection on a production line. A facet for a CSP system, specifically a dish concentrator has a parabolic design shape. This shape will concentrate near-parallel rays from the sun to a point (or a line for trough systems). Deviations of surface slope from the design shape impact the performance of the system, either losing power that misses the target or increasing peak fluxes to undesirable levels. During development or production, accurate knowledge of facet defects can lead to improvements to lower cost or improve performance. The reported characterization system, SOFAST (Sandia Optical Fringe Analysis Slope Tool), has a computer-connected camera that images the reflective surface, which is positioned so that it reflects an active target, such as an LCD screen, to the camera. A series of fringe patterns are displayed on the screen while images are captured. Using the captured information, the reflected target location of each pixel of mirror viewed can be determined, and thus through a mathematical transformation, a surface normal map can be developed. This is then fitted to the selected model equation, and the errors from design are characterized. While similar approaches have been explored, several key developments are presented here. The combination of the display, capture, and data reduction in one system allows rapid characterization. An “electronic boresight” approach is utilized to accommodate physical equipment positioning deviations, making the system insensitive to setup errors. Up to 1.5×10 6 points are characterized on each facet. Finally, while prior automotive industry commercial systems resolve the data to shape determination, SOFAST concentrates on slope characterization and reporting, which is tailored to solar applications. SOFAST can be used for facet analysis during development. However, the real payoff is in production, where complete analysis is performed in about 10s. With optimized coding, this could be further reduced.

14 SOLAR ENERGY↗

Imputation for multisource data with comparison and assessment techniques

Missing data are prevalent issue in analyses involving data collection. The problem of missing data is exacerbated for multisource analysis, where data from multiple sensors are combined to arrive at a single conclusion. In this scenario, it is more likely to occur and can lead to discarding a large amount of data collected; however, the information from observed sensors can be leveraged to estimate those values not observed. We propose two methods for imputation of multisource data, both of which take advantage of potential correlation between data from different sensors, through ridge regression and a state-space model. These methods, as well as the common median imputation, are applied to data collected from a variety of sensors monitoring an experimental facility. Performance of imputation methods is compared with the mean absolute deviation; however, rather than using this metric to solely rank themethods,we also propose an approach to identify significant differences. Imputation techniqueswill also be assessed by their ability to produce appropriate confidence intervals, through coverage and length, around the imputed values. Finally, performance of imputed datasets is compared with a marginalized dataset through a weighted k-means clustering. In general, we found that imputation through a dynamic linearmodel tended to be the most accurate and to produce the most precise confidence intervals, and that imputing the missing values and down weighting them with respect to observed values in the analysis led to the most accurate performance.

97 MATHEMATICS AND COMPUTING↗

A binary coherent optical receiver for the free-space channel

The structure of a coherent binary optical MAP receiver was derived and the effects of background radiation and phase estimation errors on receiver performance were evaluated. It was found that random phase errors do not affect the performance of the coherent receiver significantly, as long as the standard deviation of the phase error remains less than roughly 0.14 radians (or 8 degrees). It was also shown that background radiation is effectively suppressed by the optical homodyne receiver: Significant deterioration in receiver performance is observed only in the presence of extremely intense background fields. The most notable characteristic of the binary optical homodyne receiver therefore appears to be its ability to achieve quantum limited performance in high background environments, provided that sufficiently accurate estimates of the received phase can be obtained.

Vilnrotter, V. A.↗

Evaluation of Airborne Precision Spacing in a Human-in-the-Loop Experiment

A significant bottleneck in the current air traffic system occurs at the runway. Expanding airports and adding new runways will help solve this problem; however, this comes with significant costs: financially, politically and environmentally. A complementary solution is to safely increase the capacity of current runways. This can be achieved by precisely spacing aircraft at the runway threshold, with a resulting reduction in the spacing bu er required under today s operations. At NASA's Langley Research Center, the Airspace Systems program has been investigating airborne technologies and procedures that will assist the flight crew in achieving precise spacing behind another aircraft. A new spacing clearance allows the pilot to follow speed cues from a new on-board guidance system called Airborne Merging and Spacing for Terminal Arrivals (AMSTAR). AMSTAR receives Automatic Dependent Surveillance-Broadcast (ADS-B) reports from an assigned, leading aircraft and calculates the appropriate speed for the ownship to fly to achieve the desired spacing interval, time- or distance-based, at the runway threshold. Since the goal is overall system capacity, the speed guidance algorithm is designed to provide system-wide benefits and stability to a string of arriving aircraft. An experiment was recently performed at the NASA Langley Air Traffic Operations Laboratory (ATOL) to test the flexibility of Airborne Precision Spacing operations under a variety of operational conditions. These included several types of merge and approach geometries along with the complementary merging and in-trail operations. Twelve airline pilots and four controllers participated in this simulation. Performance and questionnaire data were collected from a total of eighty-four individual arrivals. The pilots were able to achieve precise spacing with a mean error of 0.5 seconds and a standard deviation of 4.7 seconds. No statistically significant di erences in spacing performance were found between in-trail and merging operations or among the three modeled airspaces. Questionnaire data showed general acceptance for both pilots and controllers. These results reinforce previous findings from full-mission simulation and flight evaluation of the in-trail operations. This paper reviews the results of this simulation in detail.

Barmore, Bryan E.↗

Effects of amplitude distortions and IF equalization on satellite communication system bit-error rate performance

Satellite communications links are subject to distortions which result in an amplitude versus frequency response which deviates from the ideal flat response. Such distortions result from propagation effects such as multipath fading and scintillation and from transponder and ground terminal hardware imperfections. Laboratory experiments performed at NASA Lewis measured the bit-error-rate (BER) degradation resulting from several types of amplitude response distortions. Additional tests measured the amount of BER improvement obtained by flattening the amplitude response of a distorted laboratory-simulated satellite channel. This paper presents the results of these experiments.

Kerczewski, Robert J.↗

Altitude deviations: Breakdowns of an error-tolerant system

Pilot reports of aviation incidents to the Aviation Safety Reporting System (ASRS) provide a window on the problems occurring in today's airline cockpits. The narratives of 10 pilot reports of errors made in the automation-assisted altitude-change task are used to illustrate some of the issues of pilots interacting with automatic systems. These narratives are then used to construct a description of the cockpit as an information processing system. The analysis concentrates on the error-tolerant properties of the system and on how breakdowns can occasionally occur. An error-tolerant system can detect and correct its internal processing errors. The cockpit system consists of two or three pilots supported by autoflight, flight-management, and alerting systems. These humans and machines have distributed access to clearance information and perform redundant processing of information. Errors can be detected as deviations from either expected behavior or as deviations from expected information. Breakdowns in this system can occur when the checking and cross-checking tasks that give the system its error-tolerant properties are not performed because of distractions or other task demands. Recommendations based on the analysis for improving the error tolerance of the cockpit system are given.

Palmer, Everett A.↗

Coordinated Control of Wind Turbine and Energy Storage System for Reducing Wind Power Fluctuation

This paper proposes a method for the coordinated control of a wind turbine and an energy storage system (ESS). Because wind power (WP) is highly dependent on wind speed, which is variable, severe stability problems can be caused in power systems, especially when the WP has a high penetration level. To solve this problem, many power generation corporations or grid operators have begun using ESSs. An ESS has very quick response and good performance for reducing the impact of WP fluctuation; however, its installation cost is high. Therefore, it is important to design the control algorithm by considering both the ESS capacity and WP fluctuation. Thus, we propose a control algorithm to mitigate the WP fluctuation by using the coordinated control between the wind turbine and the ESS by considering the ESS capacity and the WP fluctuation. Using de-loaded control, according to the WP fluctuation and ESS capacity, we can expand the ESS lifespan and improve grid reliability by avoiding the extreme value of state of charge (SoC) (i.e., 0 or 1 pu). The effectiveness of the proposed method was validated via MATLAB/Simulink by considering a small power system that includes both a wind turbine generator and conventional generators that react to system frequency deviation. We found that the proposed method has better performance in SoC management, thereby improving the frequency regulation by mitigating the impact of the WP fluctuation on the small power system.

17 WIND ENERGY↗

Evolution of Structure-Reactivity Correlations for the Hydrogen Abstraction Reaction by Chlorine Atom

Empirical structure-reactivity correlations are developed for log k298, the gas-phase rate constants for the reaction (Cl + HCR3 ClH + CR3 ). It has long been recognized that correlation with rH is weak. The poor performance of the linear Evans-Polanyi formulation s illustrated and was little improved by adding a quadratic term, e.g., by making its slope smoothly dependent on rH [ ( rH rHmin) / ( rHmax rHmin)]. The polar effect ( -Cl---H---CR3 +) has also been long discussed but there is no formalization of this dependence based on widely available independent variable(s). Using the sum of Hammett constants for the R substituents also gave at best modest correlations, either for para or for its dissection into F (field/inductive) and R (resonance) effects. Much greater success was achieved by combining these approaches with the preferred independent variable set being either [( rH)2, rH, F, and R] or [ , rH, F, and R]. For 64 rate constants which span 7 orders of magnitude, these correlation formulations give r2 > 0.87 and a mean unsigned deviation of <0.5 log k units, with even better performance if primary secondary, and tertiary reaction centers are treated separately.

chlorine atom↗

Review of the Recent Frequency Performance of the Eastern, Western and ERCOT Interconnections

The reliable operation of an electric power system depends on careful management of the balance between generation and load to ensure that system frequency is maintained within narrow bounds around a scheduled value. Yet, maintaining frequency at the scheduled value is challenging because the load served is continuously changing, and occasionally, events such as the sudden loss of a large generation plant or large amount of load, cause frequency to deviate abruptly. This report reviews the recent history of frequency performance for all three U.S. interconnections: Eastern, Western, and the Electric Reliability Council of Texas (ERCOT). The review is based on data collected by the North American Electric Reliability Corporation (NERC). The review focuses on frequency response, which measures the performance of the interconnections immediately following sudden, large imbalances between load and generation. Trends in frequency response are presented and preliminary efforts are made to relate frequency response to other aspects of frequency performance and to examine aspects of the methods used to calculate frequency response.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of Curing Temperature and Composition on the Performance Properties of Saltstone - 12473

When freshly mixed Saltstone is placed into a vault at the Savannah River Site, the heat of hydration produced during curing causes the temperature of the grout to increase. It is not uncommon for the temperature of the grout to increase by 30 to 50 deg. C above the starting temperature depending on the vault size and location, environmental conditions and pour schedule. For example, temperatures measured by thermocouples in one cell have exceeded 70 deg. C. The elevated temperatures, once reached, can extend for weeks or even months. Recent studies at Savannah River National Laboratory (SRNL) have shown that curing simulated Saltstone mixes at elevated temperatures can lead to reduced compressive strength and dynamic Young's modulus as well as increased total porosity when compared to the same grout mixes cured at 20 deg. C. Samples cured at 60 deg. C can have hydraulic conductivities approximately 600 times greater than samples cured at 20 deg. C. Previous studies have shown that the 60 deg. C cured mix had a dynamic Young's modulus that was half that of the mix cured at 20 deg. C. However, high temperature curing may not always have negative effects on the performance properties of the grout. These results indicate that higher curing temperatures can significantly alter the performance properties that are inputs for the Saltstone Performance Assessment. The Saltstone formulation (mix design) must produce a grout waste form that meets both placement and performance properties. A statistically designed set of mixes was developed to determine key process and compositional factors that affect the performance properties of Saltstone grout. A total of 27 mixes were batched and tested. There are eight baseline mixes that contain high and low values of aluminate concentration, varying w/p ratio, and varying fly ash content in the premix. Each of the eight mixes was cured at 22, 40 and 60 deg. C. The three additional reference mixes batched at the beginning, middle and end of testing showed good reproducibility throughout the study. The results of varying the operational and compositional factors on the performance properties of Saltstone grout are: - The Young's modulus is inversely affected by the curing temperature of the grout. - The aluminate content of the salt solution increases the Young's modulus of the Saltstone for samples cured at 20 and 40 deg. C. - All grouts cured at 60 deg. C have low Young's moduli and the composition of the grout mix did not have any positive effects on the performance properties after curing at this temperature. - The fly ash content in the premix had not discernible effect on the Young's modulus. - The water to premix ratio does not affect the Young's modulus. - Grouts made with the high aluminate salt solution have lower hydraulic conductivities than those made with the low aluminate simulant. - Temperature has an inverse effect on the hydraulic conductivity. - In general, increasing the water to premix ratio and the fly ash content will increase the hydraulic conductivity. - The porosity and cured density of the Saltstone grout are primarily a factor of the water to premix ratio of the grout formulation. The correlation between hydraulic conductivity and Young's modulus investigated in previous studies was evaluated further in this report. The current data as well as data from previous studies was fitted by a second degree polynomial function with a 77.1 % R-squared value. This model can be used to estimate the hydraulic conductivity of a sample based its Young's modulus for a limited range (E values up to 7 GPa). More data points should be included to further define the relationship between these performance properties are high Young's moduli and low hydraulic conductivities. The Young's modulus should still be measured on grouts formulated in future studies to be used as screening method for samples to be sent for hydraulic conductivity measurements. Saltstone grout has a complicated microstructure that is affected by the composition of the salt solution, the dry feed mixture composition, and the conditions under which it cures. The performance properties investigated are interrelated, which can make it difficult to determine individual relationships between various factors. Porosity is a large factor in determining both the Young's modulus and the hydraulic conductivity of the samples. Although the cured density is a straightforward measurement, it is not a significant performance property that needs further investigation. The porosity measurement provides similar and more meaningful data in relation to other performance properties. Based on the results of this study, the aluminate content of the salt solution does have an effect on the Young's modulus and the hydraulic conductivity and its effects should continue to be investigated. However, a new projection of aluminate contents should be used since projections change over time. The variability of fly ash in the premix did not prove to be a contributing factor that effects the performance properties of Saltstone and does not need to be included in future studies unless significant deviations from the baseline mix are proposed. The water to premix ratio has a significant effect on the performance properties of interest and the effects of varying this factor need further investigation. It is recommended that smaller ranges of w/p are investigated in order to provide data that is more relevant to the Saltstone being placed in the vaults. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analyzing the Performance Trade-Off in Implementing User-Level Threads

User-level threads have been widely adopted as a means of achieving lightweight concurrent execution without the costs of OS-level threads. Nevertheless, the costs of managing user-level threads represent a performance barrier that dictates how fine grained the concurrency exposed by an application can be without incurring significant overheads; this in turn may translate into insufficient parallelism to exploit highly parallel systems. This article is a deep dive into the fundamental costs in implementing user-level threads. We first identify that one of the highest sources of fork-join overheads stems from deviations, events that incur context switching during the execution of a thread and disrupt a run-to-completion execution. We then conduct an in-depth investigation of a wide spectrum of methods with respect to how they handle deviations while covering both parent- and child-first scheduling policies. Our methodology involves a comprehensive instruction- and cache-level analysis of all methods on several modern CPU architectures. Finally, the primary finding of our evaluation is that dynamic promotion methods that assume the absence of deviation and dynamically provide context-switching support offer the best trade-off between performance and capability when the likelihood of deviation is low.

97 MATHEMATICS AND COMPUTING↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗