Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

QCD Precision Measurements and Structure Function Extraction at a High Statistics, High Energy Neutrino Scattering Experiment: NuSOnG

We extend the physics case for a new high-energy, ultra-high statistics neutrino scattering experiment, NuSOnG (Neutrino Scattering On Glass) to address a variety of issues including precision QCD measurements, extraction of structure functions, and the derived Parton Distribution Functions (PDFs). This experiment uses a Tevatron-based neutrino beam to obtain a sample of Deep Inelastic Scattering (DIS) events which is over two orders of magnitude larger than past samples. We outline an innovative method for fitting the structure functions using a parameterized energy shift which yields reduced systematic uncertainties. High statistics measurements, in combination with improved systematics, will enable NuSOnG to perform discerning tests of fundamental Standard Model parameters as we search for deviations which may hint of 'Beyond the Standard Model' physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ACCURATE TEMPERATURE MEASUREMENTS IN A NATURALLY-ASPIRATED RADIATION SHIELD

Experiments and calculations were conducted with a 0.13 mm fine wire thermocouple within a naturally-aspirated Gill radiation shield to assess and improve the accuracy of air temperature measurements without the use of mechanical aspiration, wind speed or radiation measurements. It was found that this thermocouple measured the air temperature with root-mean-square errors of 0.35 K within the Gill shield without correction. A linear temperature correction was evaluated based on the difference between the interior plate and thermocouple temperatures. This correction was found to be relatively insensitive to shield design and yielded an error of 0.16 K for combined day and night observations. The correction was reliable in the daytime when the wind speed usually exceeds 1 m s{sup -1} but occasionally performed poorly at night during very light winds. Inspection of the standard deviation in the thermocouple wire temperature identified these periods but did not unambiguously locate the most serious events. However, estimates of sensor accuracy during these periods is complicated by the much larger sampling volume of the mechanically-aspirated sensor compared with the naturally-aspirated sensor and the presence of significant near surface temperature gradients. The root-mean-square errors therefore are upper limits to the aspiration error since they include intrinsic sensor differences and intermittent volume sampling differences.

47 OTHER INSTRUMENTATION↗

SPRUCE Sphagnum Phytobiome Responses to Whole Ecosystem Warming and Elevated Atmospheric CO2 in July, 2017-2021

This dataset reports the carbon (C) and nitrogen (N) isotopic composition of Sphagnum moss tissue collected from the Spruce and Peatland Responses Under Changing Environments (SPRUCE) experimental site within the Marcell Experimental Forest in northern Minnesota, USA. Tissues were collected inside the SPRUCE experimental study plot, where air and peat warming are combined in whole-ecosystem warming treatments, from 2019-2021. Additionally, rates of nitrogen fixation and methane oxidation measured for Sphagnum from 2017, 2019, and 2021. Sphagnum tissue % water content was measured at all timepoints. This dataset was used to conduct analyses within Petro et al (2023). Sphagnum C and N concentrations and 13C and 15N isotopic natural abundance were determined for three replicate Sphagnum tissue samples collected from inside the SPRUCE enclosures in July 2019-2021. Elemental and isotope analyses were conducted at the University of Georgia – Center for Applied Isotope Studies (CAIS; https://cais.uga.edu/). Plant elemental analysis was performed by the micro-Dumas method, while isotopic natural abundance was measured by isotope ratio mass spectrometry. 13C natural abundance is expressed as the per mille (‰) deviation from the Pee Dee Belemnite standard (PDB) 13C:12C ratio (δ13C), while 15N natural abundance is expressed as the ‰ deviation from the N2 atmospheric 15N:14N ratio (δ15N). Rates of nitrogen fixation and methane oxidation were measured using serum bottle incubations performed with Sphagnum collected inside the SPRUCE enclosures in July 2017, 2019, and 2021. Rates were calculated according to the amount of 15N-N2 or 13C-CH4 (methane) incorporated into the Sphagnum tissue or incubation headspace over the 48-hour intion period. In 2017, incubations were performed in growth chambers set to the temperature of the experimental plots during Sphagnum sampling. In 2019 and 2021, the incubations were performed directly inside the experimental plots. The 13C and 15N isotopic natural abundance data and rate measurements presented in this dataset provide insight into the impacts of whole-ecosystem warming and elevated atmospheric carbon dioxide (CO2) on N and C cycling within the Sphagnum phytobiome. This dataset contains two data files in comma-separate values (*.csv) format. Additional metadata are provided: two data dictionaries and a file-level metadata file in comma-separate values (.csv) format and a user guide in PDF (*.pdf) format. Additional datasets on NH4-N availability, porewater concentrations of CH4 and CO2, and Sphagnum groundcover within the SPRUCE experimental plots are available. These are outlined in the Related Datasets section in the user guide.

delta 13 carbon↗

Digital holography simulations and experiments to quantify the accuracy of 3D particle location and 2D sizing using a proposed hybrid method

The accuracy of digital in-line holography to detect particle position and size within a 3D domain is evaluated with particular focus placed on detection of nonspherical particles. Dimensionless models are proposed for simulation of holograms from single particles, and these models are used to evaluate the uncertainty of existing particle detection methods. From the lessons learned, a new hybrid method is proposed. This method features automatic determination of optimum thresholds, and simulations indicate improved accuracy compared to alternative methods. To validate this, experiments are performed using quasi-stationary, 3D particle fields with imposed translations. For the spherical particles considered in experiments, the proposed hybrid method resolves mean particle concentration and size to within 4% of the actual value, while the standard deviation of particle depth is less than two particle diameters. Initial experimental results for nonspherical particles reveal similar performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy system

Purpose: To characterize the performance of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy (MR-IGRT) system. Methods: The imaging performance characterization included four components: ACR (the American College of Radiology) phantom test, spatial integrity, coil signal to noise ratio (SNR) and uniformity, and magnetic field homogeneity. The ACR phantom test was performed in accordance with the ACR phantom test guidance. The spatial integrity test was evaluated using a 40.8 × 40.8 × 40.8 cm{sup 3} spatial integrity phantom. MR and computed tomography (CT) images of the phantom were acquired and coregistered. Objects were identified around the surfaces of 20 and 35 cm diameters of spherical volume (DSVs) on both the MR and CT images. Geometric distortion was quantified using deviation in object location between the MR and CT images. The coil SNR test was performed according to the national electrical manufacturers association (NEMA) standards MS-1 and MS-9. The magnetic field homogeneity test was measured using field camera and spectral peak methods. Results: For the ACR tests, the slice position error was less than 0.10 cm, the slice thickness error was less than 0.05 cm, the resolved high-contrast spatial resolution was 0.09 cm, the resolved low-contrast spokes were more than 25, the image intensity uniformity was above 93%, and the percentage ghosting was less than 0.22%. All were within the ACR recommended specifications. The maximum geometric distortions within the 20 and 35 cm DSVs were 0.10 and 0.18 cm for high spatial resolution three-dimensional images and 0.08 and 0.20 cm for high temporal resolution two dimensional cine images based on the distance-to-phantom-center method. The average SNR was 12.0 for the body coil, 42.9 for the combined torso coil, and 44.0 for the combined head and neck coil. Magnetic field homogeneities at gantry angles of 0°, 30°, 60°, 90°, and 120° were 23.55, 20.43, 18.76, 19.11, and 22.22 ppm, respectively, using the field camera method over the 45 cm DSV. Conclusions: The onboard imaging unit of the first commercial MR-IGRT system meets ACR, NEMA, and vendor specifications.

60 APPLIED LIFE SCIENCES↗

Data acquisition for the new muon g-2 experiment at Fermilab

A new measurement of the anomalous magnetic moment of the muon, a μ ≡ (g - 2)/2, will be performed at the Fermi National Accelerator Laboratory. The most recent measurement, performed at Brookhaven National Laboratory and completed in 2001, shows a 3.3-3.6 standard deviation discrepancy with the Standard Model predictions for a μ . The new measurement will accumulate 21 times those statistics, measuring a μ to 140 ppb and reducing the uncertainty by a factor of 4. The data acquisition system for this experiment must have the ability to record deadtime-free records from 700 μs muon spills at a raw data rate of 18 GB per second. Data will be collected using 1296 channels of μTCA-based 800 MSPS, 12 bit waveform digitizers and processed in a layered array of networked commodity processors with 24 GPUs working in parallel to perform a fast recording and processing of detector signals during the spill. The system will be controlled using the MIDAS data acquisition software package. Lastly, the described data acquisition system is currently being constructed, and will be fully operational before the start of the experiment in 2017.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Q{sub Weak}{sup p} Experiment A Search For Physics Beyond The Standard Model Via A Measurement Of The Proton's Weak Charge

The Qweak collaboration is currently preparing a measurement of the proton's weak charge Q{sub W}{sup p} = (1-4 sin{sup 2{theta}}{sub W}) at the Thomas Jefferson National Accelerator Facility (TJNAF). The experiment has been designed to produce a 4.1% measurement of the weak charge, via a 2.5% measurement of the parity violating asymmetry in the number of elastically scattered 1 GeV electrons from protons, at forward angles. At the proposed precision, the experiment would produce a 0.3% measurement of the weak mixing angle at a momentum transfer of {approx_equal} 16 GeV, making it the most precise stand alone measurement of the weak mixing angle at low momentum transfer. In combination with other parity measurements, Qweak will also provide a high precision determination of the weak charges of the up and down quarks. Our proposed measurement of Q{sub W}{sup p} will be performed with significantly smaller statistical and systematic errors than existing low Q{sup 2} data. Any significant deviation from the Standard Model prediction at low momentum transfer (Q{sup 2}) would be a signal of new physics, whereas agreement would place new and significant constraints on possible Standard Model extensions. The experiment is currently being installed. Commissioning of the experiment will begin in May 2010 and the first production data will be taken in the Fall of 2010.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for massive colored scalars in four-jet final states in $\sqrt{s}=7~\mbox{TeV}$ proton–proton collisions with the ATLAS detector

A search for pair-produced scalar particles decaying to a four-jet final state is presented. The analysis is performed using an integrated luminosity of 34 pb -1 recorded by the ATLAS detector in 2010. No deviation from the Standard Model is observed. For a scalar mass of 100 GeV (190 GeV) the limit on the scalar gluon pair production cross section at 95% confidence level is 1 nb (0.28 nb). When these results are interpreted as mass limits, scalar-gluons (hyperpions) with masses of 100 to 185 GeV (100 to 155 GeV) are excluded at 95% confidence level with the exception of a mass window of width about 5 GeV (15 GeV) around 140 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of high-fidelity models for liquid fuel spray atomization and mixing processes in transportation and energy systems

Significant inadequacies of current models for multiphase flows present a major barrier to rapid development of advanced high-efficiency low-emissions combustion devices. Liquid spray atomization processes largely determine fuel-air mixture formation, which subsequently govern combustion and controls performance, emissions, and durability of a device. The current study presents a fundamentally-consistent framework to model the effects of breakup processes, liquid drop deformations, and internal flow dynamics on mass, momentum, and energy exchange functions. This framework builds on the Taylor Analogy Breakup (TAB) model which naturally quantifies local drop deformation dynamics. Real-fluid multicomponent thermodynamic property modeling and Gradient Theory simulations facilitate accurate calculations of molecular two-phase interface exchange functions, surface tensions forces, drop oscillations, and breakup processes. The analysis establishes that these drop dynamics, along with finite liquid viscosity effects, significantly alter gas-liquid exchange functions. The study quantifies these effects for the resulting drag coefficients of liquid drops and demonstrates significant deviations from the classic dynamic drag model, which is widely applied in modern simulations performed in academia and industry. This work also quantifies effects, which originate from gas-liquid coupling dynamics, on evaporation and heating rates. The analysis establishes that the consideration of these coupling dynamics modify mass and energy transfer rates even more significantly than the corresponding drag forces from momentum exchange. This physical complexity, however, is largely neglected in modern studies from academia and industry. A new set of equations is presented to improve the modeling of drop breakup processes to address the current shortcomings in the prediction of resulting drops proper- ties over the full range of relevant breakup conditions. The framework is based on a refined energy balance equation which explicitly enforces drop momentum conservation during the breakup process. The introduced modeling framework is entirely derived from conservation equations for mass, momentum, and energy and does not, as a consequence, introduce new modeling constants. The significance of the developed modeling advances to fuel injection processes is demonstrated using Large Eddy Simulation (LES) with a Lagrangian-Eulerian modeling approach.

42 ENGINEERING↗

Search for the Higgs boson decay to a Z boson and a photon in pp collisions at $\sqrt{s}$ = 13 TeV and 13.6 TeV with the ATLAS detector

A search for the Higgs boson decay to a Z boson and a photon in the ℓℓγ (ℓ = 𝑒,𝜇) final state is performed using pp collisions at $\sqrt{s}$ = 13.6 TeV recorded with the ATLAS detector at the Large Hadron Collider during 2022–2024, corresponding to an integrated luminosity of 165 fb−1. The signal yield, normalised to the Standard Model prediction, is measured to be 𝜇 = 0.9$^{+0.7}_{−0.6}$, compatible with the expected value of 𝜇 = 1.0 ± 0.7. This corresponds to an observed (expected) signal significance of 1.4 (1.5) standard deviations under the background-only hypothesis. This result is combined with that of a similar search performed with 140 fb −1 of $\sqrt{s}$ = 13 TeV pp collisions to provide the best expected sensitivity to date to this rare decay, namely an observed (expected) signal strength of 𝜇 = 1.3$^{+0.6}_{−0.5}$ (𝜇 = 1.0$^{+0.6}_{−0.5}$), corresponding to an observed (expected) significance of 2.5 (1.9) standard deviations. The measurement is consistent with the Standard Model expectation.

Aad, G. (ORCID:0000000266654934)↗

Recent Updates in ETOE-2 and MC 2 -3

The MC 2 -3 code is a multigroup cross section generation code for fast reactor applications, developed by Argonne National Laboratory (ANL) under the DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In this work, first, the cross section libraries for ENDF/B-VII.1 and ENDF/B-VIII.0 data were generated using the updated ETOE-2 code. Preliminary verification and validation tests of the ENDF/B-VII.1 MC 2 -3 library were performed with the selected fast reactor benchmark problems. Processing and verifying the libraries suggested that significant efforts would be required for thoroughly verifying the ENDF/B-VII.1 MC 2 -3 library and successfully processing the ENDF/B-VIII.0 MC 2 -3 library. Secondly, the cross section generation capability of MC 2 -3 was updated with the intermediate group lattice calculation and the equivalent Dancoff-factor cell (EDC) method to significantly improve the performance of a twodimensional assembly calculation using the method of characteristics (MOC). This effort was made useful in implementing and verifying the EDC method in the Griffin cross section API. Finally, we analyzed a SFR problem, for which unusually large deviations in core eigenvalues from Monte Carlo solutions were reported, by generating multigroup cross sections with MC 2 -3, performing core calculations with DIF3D-VARIANT, and analyzing cross section and eigenvalue results against Monte Carlo solutions. The analysis confirmed that the MC 2 -3/DIF3D solutions were in good agreement with Monte Carlo solutions, providing the correct process of accurately generating broad-group cross sections with MC 2 -3

97 MATHEMATICS AND COMPUTING↗

Search for a heavy resonance decaying to a pair of vector bosons in the lepton plus merged jet final state at $ \sqrt{s}=13 $ TeV

A search for a new heavy particle decaying to a pair of vector bosons (WW or WZ) is presented using data from the CMS detector corresponding to an integrated luminosity of 35.9 fb$^{−1}$ collected in proton-proton collisions at a centre-of-mass energy of 13 TeV in 2016. One of the bosons is required to be a W boson decaying to eν or μν, while the other boson is required to be reconstructed as a single massive jet with substructure compatible with that of a highly-energetic quark pair from a W or Z boson decay. The search is performed in the resonance mass range between 1.0 and 4.4 TeV. The largest deviation from the background-only hypothesis is observed for a mass near 1.4 TeV and corresponds to a local significance of 2.5 standard deviations. The result is interpreted as an upper bound on the resonance production cross section. Comparing the excluded cross section values and the expectations from theoretical calculations in the bulk graviton and heavy vector triplet models, spin-2 WW resonances with mass smaller than 1.07 TeV and spin-1 WZ resonances lighter than 3.05 TeV, respectively, are excluded at 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Independent calculation-based verification of IMRT plans using a 3D dose-calculation engine

Independent monitor unit verification of intensity-modulated radiation therapy (IMRT) plans requires detailed 3-dimensional (3D) dose verification. The aim of this study was to investigate using a 3D dose engine in a second commercial treatment planning system (TPS) for this task, facilitated by in-house software. Our department has XiO and Pinnacle TPSs, both with IMRT planning capability and modeled for an Elekta-Synergy 6 MV photon beam. These systems allow the transfer of computed tomography (CT) data and RT structures between them but do not allow IMRT plans to be transferred. To provide this connectivity, an in-house computer programme was developed to convert radiation therapy prescription (RTP) files as generated by many planning systems into either XiO or Pinnacle IMRT file formats. Utilization of the technique and software was assessed by transferring 14 IMRT plans from XiO and Pinnacle onto the other system and performing 3D dose verification. The accuracy of the conversion process was checked by comparing the 3D dose matrices and dose volume histograms (DVHs) of structures for the recalculated plan on the same system. The developed software successfully transferred IMRT plans generated by 1 planning system into the other. Comparison of planning target volume (TV) DVHs for the original and recalculated plans showed good agreement; a maximum difference of 2% in mean dose, − 2.5% in D95, and 2.9% in V95 was observed. Similarly, a DVH comparison of organs at risk showed a maximum difference of +7.7% between the original and recalculated plans for structures in both high- and medium-dose regions. However, for structures in low-dose regions (less than 15% of prescription dose) a difference in mean dose up to +21.1% was observed between XiO and Pinnacle calculations. A dose matrix comparison of original and recalculated plans in XiO and Pinnacle TPSs was performed using gamma analysis with 3%/3 mm criteria. The mean and standard deviation of pixels passing gamma tolerance for XiO-generated IMRT plans was 96.1 ± 1.3, 96.6 ± 1.2, and 96.0 ± 1.5 in axial, coronal, and sagittal planes respectively. Corresponding results for Pinnacle-generated IMRT plans were 97.1 ± 1.5, 96.4 ± 1.2, and 96.5 ± 1.3 in axial, coronal, and sagittal planes respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Observation of B$^0_s$ mesons and measurement of the B$^0_s$/B$^+$ yield ratio in PbPb collisions at $\sqrt{s_\mathrm{NN}}$ = 5.02 TeV

The B$^0_s$ and B$^+$ production yields are measured in PbPb collisions at a center-of-mass energy per nucleon pair of 5.02 TeV. The data sample, collected with the CMS detector at the LHC, corresponds to an integrated luminosity of 1.7 nb$^{-1}$. The mesons are reconstructed in the exclusive decay channels B$^0_s$$\to$ J/$\psi(\mu^+\mu^-)\phi($K$^+$K$^-)$ and B$^+$$\to$ J/$\psi(\mu^+\mu^-)$K$^+$. The B$^0_s$ meson is observed with a statistical significance in excess of five standard deviations for the first time in nucleus-nucleus collisions. The measurements are performed as functions of the transverse momentum of the B mesons and of the PbPb collision centrality. The ratio of production yields of B$^0_s$ and B$^+$ is measured and compared to theoretical models that include quark recombination effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterising the Higgs boson with ATLAS data from the LHC Run-2

The Higgs boson was discovered by the ATLAS and CMS Collaborations in 2012 using data from Run 1 of the Large Hadron Collider (2010 2012). In Run 2 (2015 2018), about 140 fb -1 of proton–proton collisions at a centre-of-mass energy of 13 TeV were collected by the ATLAS experiment. This review presents the most important Run 2 results obtained by the ATLAS Collaboration regarding the properties of the Higgs boson and its interactions with other particles. The performed studies significantly enhance the understanding of the Higgs boson, while hunting for deviations from the predictions of the Standard Model of particle physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dipole Moment Calculations Using Multiconfiguration Pair-Density Functional Theory and Hybrid Multiconfiguration Pair-Density Functional Theory

The dipole moment is the molecular property that most directly indicates molecular polarity. The accuracy of computed dipole moments depends strongly on the quality of the calculated electron density, and the breakdown of single-reference methods for strongly correlated systems can lead to poor predictions of the dipole moments in those cases. Here, we derive the analytical expression for obtaining the electric dipole moment by multiconfiguration pair density functional theory (MCPDFT), and we assess the accuracy of MC-PDFT for predicting dipole moments at equilibrium and nonequilibrium geometries. We show that MC-PDFT dipole moment curves have reasonable behavior even for stretched geometries, and they significantly improve upon the CASSCF results by capturing more electron correlation. Herein, the analysis of a dataset consisting of 18 first-row transition metal diatomics and 6 main-group polyatomic molecules with multireference character suggests that MC-PDFT and its hybrid extension (HMC-PDFT) perform comparably to CASPT2 and MRCISD+Q methods and have a mean unsigned deviation of 0.2–0.3 D with respect to the best available dipole moment reference values. We explored the dependence of the predicted dipole moments upon the choice of the on-top density functional and active space, and we recommend the tPBE and hybrid tPBE0 on-top choices for the functionals combined with the moderate correlated participating orbital scheme for selecting the active space. With these choices, the mean unsigned deviations (in debyes) of the calculated equilibrium dipole moments from the best estimates are 0.77 for CASSCF, 0.29 for MC-PDFT, 0.24 for HMCPDFT, 0.28 for CASPT2, and 0.25 for MRCISD+Q. These results are encouraging because the computational cost of MC-PDFT or HMC-PDFT is largely reduced compared to the CASPT2 and MRCISD+Q methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting third-body collision efficiencies for water and other polyatomic baths

Low-pressure-limit microcanonical (collisional activation) and thermal rate constants are predicted using a combination of automated ab initio potential energy surface construction, classical trajectories, transition state theory, and a detailed energy- and angular-momentum-resolved collision kernel. Several systems are considered, including CH 4 (+M) and HO 2 (+M), with an emphasis on systems where experimental information is available for comparison. The a priori approach involves no adjustable parameters, and we show that the predicted thermal rate constants are in excellent agreement with experiments, with average deviations of less than 25%. Notably, the a priori approach is shown to perform equally well for atomic, diatomic, and polyatomic baths, including M = H 2 O, CO 2 , and “fuel” baths like M = CH 4 and NH 3 . Additionally, the utility of microcanonical rate constants for interpreting trends and inferring mechanistic details in the thermal kinetics is demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variable gamma-ray sky at 1 GeV

We search for the long-term variability of the gamma-ray sky in the energy range E > 1 GeV with 168 weeks of the gamma-ray telescope Fermi-LAT data. We perform a full sky blind search for regions with variable flux looking for deviations from uniformity. We bin the sky into 12288 pixels using the HEALPix package and use the Kolmogorov-Smirnov test to compare weekly photon counts in each pixel with the constant flux hypothesis. The weekly exposure of Fermi-LAT for each pixel is calculated with the Fermi-LAT tools. We consider flux variations in a pixel significant if the statistical probability of uniformity is less than 4 Multiplication-Sign 10{sup -6}, which corresponds to 0.05 false detections in the whole set. We identified 117 variable sources, 27 of which have not been reported variable before. The sources with previously unidentified variability contain 25 active galactic nuclei (AGN) belonging to the blazar class (11 BL Lacs and 14 FSRQs), one AGN of an uncertain type, and one pulsar PSR J0633+1746 (Geminga).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗