Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

Assessing the hygrothermal performance of bio-based materials in building wall systems

Building envelope systems are crucial in regulating thermal and moisture exchange between interior and exterior environments, accounting for approximately 28 % of building energy consumption in the United States with walls being the primary contributors. Improper selection of building envelope materials can lead to moisture-related issues, reduced resilience, and compromised durability. Hygrothermal performance assessment is a key factor in efficient building design. As such, improving the energy and hygrothermal performance of opaque wall materials, through careful assessment of material choices, is essential to enhancing building resilience, lowering energy costs, and improving occupant comfort. As the building industry seeks new strategies to reduce material energy intensity, bio-based materials emerge as a promising solution. However, their long-term hygrothermal performance in building envelope systems remains underexplored. To fill this gap, this study evaluates the hygrothermal behavior of 13 bio-based materials in residential wall systems across three U.S. climate zones. Laboratory experiments were performed to measure material properties such as density, thermal conductivity, moisture transmission, and sorption isotherms. These data were integrated into the WUFI® simulation tool to assess wall hygrothermal performance in Houston, Baltimore, and Chicago. A three-phase modeling approach was used: (1) baseline residential walls with oriented strand board (OSB) and gypsum board; (2) replacing OSB with bio-based materials; and (3) replacing drywall with bio-based materials. Results showed that the evaluated bio-based materials maintained acceptable moisture thresholds of ≤ 16 % across all climates, confirming their viability as an alternative for current sheathing materials. Furthermore, this study provides a foundation for future research and innovation in material science on the use of certain bio-based materials in high-performance, low energy use residential construction. Ultimately, providing critical data, offering a database of bio-based material properties, and supplying a simulation-based approach will help designers make informed decisions for future efficient building practices.

Bio-based materials↗

Assessment of the Performance of the Atmospheric Correction Algorithm MAJA for Sentinel-2 Surface Reflectance Estimates

The correction of atmospheric effects on optical remote sensing products is an essential component of Analysis Ready Data (ARD) production lines. The MAJA processor aims at providing accurate time series of surface reflectances over land for satellite missions, such as Sentinel-2, Venμs, and Landsat 8. The Centre d’Études Spatiales de la Biosphère (CESBIO) and the Centre National d’Études Spatiales (CNES) share a common effort to maintain, validate, and improve the MAJA processor, using state-of-the-art ground measurement sites, and participating in processor inter-comparisons, such as the Atmospheric Correction Intercomparison Exercise (ACIX). While contributing to the second ACIX-II Land validation exercise, it was found that the candidate MAJA dataset could not adequately be compared to the main reference dataset. MAJA reflectances were corrected for adjacency and topography effects while the reference dataset was not, excluding MAJA from a part of the performance metrics of the exercise. The first part of the following study aims at providing complementary performance assessment to ACIX-II by reprocessing MAJA surface reflectances without adjacency nor topographic correction, allowing for an un-biased full resolution comparison with the reference Sentinel-2 dataset. The second part of the study consists of validating MAJA against surface reflectance measurements time series of up to five years acquired at three automated stations. Both approaches provide extensive insights on the quality of MAJA Sentinel-2 Level 2 products.

ROSAS↗

Performance Index Assessment for the PV Fleet Performance Data Initiative

We report on 250 PV systems throughout the United States, comprising 157 MWdc of system capacity and more than 10,000 monthly performance index (PI) values. Loss factors were isolated including first-year start-up issues, snowfall, soiling and inverter downtime. Inverter availability was found to contribute significant system energy loss during the first six months of operation, with an average of 8% loss occurring during this period, and 2.3% on average thereafter. Other start-up issues beyond inverter downtime, such as partial string outage, contributed additional underperformance in the first year of operation across the fleet. Winter performance was also found to be below summer performance on average, likely due to snowfall. A relationship was found between monthly snowfall accumulation in centimeters and monthly under-performance, indicating a 6%-40% loss in months with measured snowfall, depending on climate. After correcting for availability, snow and startup loss, over 90% of systems were performing within 10% of monthly expectation based on satellite resource data and PVWatts production estimates.

loss factors↗

Automated Portable Test System (APTS) - A performance envelope assessment tool

The reliability and stability of microcomputer-based psychological tests are evaluated. The hardware, test programs, and system control of the Automated Portable Test System, which assesses human performance and subjective status, are described. Subjects were administered 11 pen-and-pencil and microcomputer-based tests for 10 sessions. The data reveal that nine of the 10 tests stabilized by the third administration; inertial correlations were high and consistent. It is noted that the microcomputer-based tests display good psychometric properties in terms of differential stability and reliability.

Kennedy, R. S.↗

Understanding Solar Photovoltaic System Performance: An Assessment of 75 Federal Photovoltaic Systems

This report presents a performance analysis of 75 photovoltaic systems based on PV system production data collected as part of a FEMP Federal PV Performance Assessment project combined with co-incident insolation, and ambient temperature to analyze how actual performance compares with a performance model. FEMP collaborated with 17 Federal agencies and sub-agencies to collect the information required to analyze the performance of each system. The systems represent a total capacity of 30,714 kW and range in size from 1 kW to 4,043 kW, with an average size of 410 kW, and were installed between 2011 and 2020. The data is analyzed for Key Performance Indicators, Availability, Performance Ratio and Energy Ratio by comparing the measured production data to model production data. The System Advisor Model (SAM) combines a description of the system (such as inverter capacity, de-rating for temperature, balance-of-system efficiency) with environmental parameters (coincident solar and temperature data) to calculate predicted performance. The performance metrics are calculated by lining up the measured production data with the model estimate on an hour-by-hour, day-by-day, or month-by-month basis (depending on the interval resolution of the production data). A report with system description, photo of the system, special assumptions made for the site, graph of measured production and model production, table of key performance indicators, and links to O&M resources that might improve performance was produced and delivered to site and agency staff with a short on-line briefing.

14 SOLAR ENERGY↗

Understanding the Uncertainty in the Technical Performance Level Assessment for Wave Energy

In recent years, the design and development of wave energy converters (WECs) has been explored with intense interest, with highly varying design concepts emerging globally across both research enterprises and industry. The design space for WECs is vast - many concepts ranging in functionality, control systems, power development systems, materials, and scale have been ideated and prototyped, but WEC technology has yet to converge. One critical element of the technology trajectory that governs the speed of adoption is the performance of a WEC concept. In analogous but more-established industries (such as aerospace, and environmentally sustainable electronics design), performance assessment is a quantitative method, based on historical data, that is used as an iterative tool to improve the design of these systems early on in the design process. Though more nascent than these approaches, in wave energy R&D, WEC performance has been assessed using the Technology Performance Level (TPL) assessment, which provides designers with a quantitative score, situating a grid-scale WEC concept on a scale from 1-9 (1 being the lowest performance, and 9 being the highest, trending with the oft-used Technology Readiness Level, or TRL). The TPL assessment is designed to be used during design iteration, when a WEC concept is fully ideated, to enable designers to consider potential means of improving the downstream performance of the concept. One concern that may be slowing the adoption of TPL among WEC developers is the inherent uncertainty in the assessment, and how uncertainty in the individual questions asked as part of the assessment may contribute to perceived inaccuracies in the final score. In this work, we explore the uncertainty present in the assessment and quantify this uncertainty using both traditional mathematical operations and a Monte Carlo simulation. Results imply areas of improvement of the TPL assessment, where reducing uncertainty will be most helpful to end users, enabling both TPL practitioners and users to understand with more accuracy those design elements that can be improved to impact device performance most substantively.

techno-economic analysis↗