Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Design and Analysis of a Single-Shot Longitudinal Phase Space Measurement Diagnostics at the Argonne Wakefield Accelerator

A single-shot longitudinal phase space diagnostics is currently being assembled at the Argonne Wakefield Accelerator (AWA). The diagnostics consists of mapping the longitudinal phase space coordinates to the transverse position space plane using a beamline that incorporates two magnetic dipoles arranged as a dogleg followed by an rf deflecting cavity. The deflecting cavity streaks the beam vertically while the dipole magnets bend horizontally. In this paper, we analyze analytically and via numerical simulations the performances of such diagnostics and their limitations. Simulations done in IMPACT-T shows good reconstruction of the longitudinal phase space.

43 PARTICLE ACCELERATORS↗

Phasing of the Triatoma virus diffraction data using a cryo-electron microscopy reconstruction

The blood-sucking reduviid bug Triatoma infestans, one of the most important vector of American human trypanosomiasis (Chagas disease) is infected by the Triatoma virus (TrV). TrV has been classified as a member of the Cripavirus genus (type cricket paralysis virus) in the Dicistroviridae family. This work presents the three-dimensional cryo-electron microscopy (cryo-EM) reconstruction of the TrV capsid at about 25 A resolution and its use as a template for phasing the available crystallographic data by the molecular replacement method. The main structural differences between the cryo-EM reconstruction of TrV and other two viruses, one from the same family, the cricket paralysis virus (CrPV) and the human rhinovirus 16 from the Picornaviridae family are presented and discussed.

60 APPLIED LIFE SCIENCES↗

SU-E-J-219: A Dixon Based Pseudo-CT Generation Method for MR-Only Radiotherapy Treatment Planning of the Pelvis and Head and Neck

Purpose: To develop an image processing method for MRI-based generation of electron density maps, known as pseudo-CT (pCT), without usage of model- or atlas-based segmentation, and to evaluate the method in the pelvic and head-neck region against CT. Methods: CT and MRI scans were obtained from the pelvic region of four patients in supine position using a flat table top only for CT. Stratified CT maps were generated by classifying each voxel based on HU ranges into one of four classes: air, adipose tissue, soft tissue or bone.A hierarchical region-selective algorithm, based on automatic thresholding and clustering, was used to classify tissues from MR Dixon reconstructed fat, In-Phase (IP) and Opposed-Phase (OP) images. First, a body mask was obtained by thresholding the IP image. Subsequently, an automatic threshold on the Dixon fat image differentiated soft and adipose tissue. K-means clustering on IP and OP images resulted in a mask that, via a connected neighborhood analysis, allowing the user to select the components corresponding to bone structures.The pCT was estimated through assignment of bulk HU to the tissue classes. Bone-only Digital Reconstructed Radiographs (DRR) were generated as well. The pCT images were rigidly registered to the stratified CT to allow a volumetric and voxelwise comparison. Moreover, pCTs were also calculated within the head-neck region in two volunteers using the same pipeline. Results: The volumetric comparison resulted in differences <1% for each tissue class. A voxelwise comparison showed a good classification, ranging from 64% to 98%. The primary misclassified classes were adipose/soft tissue and bone/soft tissue. As the patients have been imaged on different table tops, part of the misclassification error can be explained by misregistration. Conclusion: The proposed approach does not rely on an anatomy model providing the flexibility to successfully generate the pCT in two different body sites. This research is founded by ZonMw IMDI Programme, project name: “RASOR sharp: MRI based radiotherapy planning using a single MRI sequence”, project number: 10-104003010.

60 APPLIED LIFE SCIENCES↗

Ptychography at all wavelengths

Ptychography is a computational imaging technique that operates across multiple wavelength regimes, from electron (picometres) to X-ray (~0.1 nm), extreme ultraviolet (~10 nm) and visible light (micrometres). By reconstructing both amplitude and phase from diffraction patterns, ptychography enables high-resolution, quantitative imaging without conventional limitations imposed by lens-based optics. Ptychography has enabled advances across a range of scales: achieving deep-sub-angstrom resolution with electron microscopy, becoming an indispensable tool at X-ray synchrotron facilities worldwide and overcoming the trade-offs between resolution and field-of-view in optical imaging. This Primer provides a unified treatment of ptychography across these wavelength regimes. First, we discuss theoretical foundations, reconstruction algorithms, experimental considerations and wavelength-specific challenges. We then give examples of raw and processed data from various configurations and wavelengths. Next, we highlight key applications of ptychography in life sciences, materials science and industry. We also discuss data standards, open-source software implementations and best practices for ensuring reproducibility across different wavelength regimes. Finally, we consider limitations and future opportunities for ptychography. Together with accompanying datasets and code implementations, this Primer aims to serve newcomers and experienced practitioners in the field, facilitating broader adoption of ptychography across different disciplines.

47 OTHER INSTRUMENTATION↗

Accommodating a hexagonal ζ- phase Mn 2 N film on a cubic MgO (001) substrate

The thin films of c -plane dominated hexagonal ζ- phase Mn 2 N were successfully grown on a cubic MgO (001) substrate directly using plasma-assisted molecular beam epitaxy. The surface was comprehensively studied through experimental and theoretical approaches. Reflection high energy electron diffraction revealed two pseudo-cubic domains along [100] MgO and [110] MgO , and one hexagonal domain, which is 30° apart from the [100] MgO direction. Scanning tunneling microscopy was used to image and resolve the high-quality surface, revealing a distorted hexagonal surface structure. Furthermore, atomic resolution of the hexagonal domain with a 2 × 2 reconstructed surface is presented. For c-plane surface, theoretical investigations were carried out using first principles studies to determine the surface formation energy for various reconstructed surfaces. The theoretical study shows that the nitrogen terminated 2 × 2 structure with a manganese adatom on the surface as the most stable reconstruction that reproduces the experimental results. A corresponding simulated scanning tunneling microscopy model is also presented, providing strong support for the experimentally observed in-plane lattice structures. Furthermore, the manganese: nitrogen stoichiometry within the bulk and surface is in good agreement with the expected ratio of 2:1.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-D-18C-01: A Novel 4D-MRI Technology Based On K-Space Retrospective Sorting

Purpose: Current 4D-MRI techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of an entirely new framework of 4D-MRI based on k-space retrospective sorting. Methods: An important challenge of the proposed technique is to determine the number of repeated scans(NR) required to obtain sufficient k-space data for 4D-MRI. To do that, simulations using 29 cancer patients' respiratory profiles were performed to derive the relationship between data acquisition completeness(Cp) and NR, also relationship between NR(Cp=95%) and the following factors: total slice(NS), respiratory phase bin length(Lb), frame rate(fr), resolution(R) and image acquisition starting-phase(P0). To evaluate our technique, a computer simulation study on a 4D digital human phantom (XCAT) were conducted with regular breathing (fr=0.5Hz; R=256×256). A 2D echo planer imaging(EPI) MRI sequence were assumed to acquire raw k-space data, with respiratory signal and acquisition time for each k-space data line recorded simultaneously. K-space data was re-sorted based on respiratory phases. To evaluate 4D-MRI image quality, tumor trajectories were measured and compared with the input signal. Mean relative amplitude difference(D) and cross-correlation coefficient(CC) are calculated. Finally, phase-sharing sliding window technique was applied to investigate the feasibility of generating ultra-fast 4D-MRI. Result: Cp increased with NR(Cp=100*[1-exp(-0.19*NR)], when NS=30, Lb=100%/6). NR(Cp=95%) was inversely-proportional to Lb (r=0.97), but independent of other factors. 4D-MRI on XCAT demonstrated highly accurate motion information (D=0.67%, CC=0.996) with much less artifacts than those on image-based sorting 4D-MRI. Ultra-fast 4D-MRI with an apparent temporal resolution of 10 frames/second was reconstructed using the phase-sharing sliding window technique. Conclusions: A novel 4D-MRI technology based on k-space sorting has been successfully developed and evaluated on the digital phantom. Framework established can be applied to a variety of MR sequences, showing great promises to develop the optimal 4D-MRI technique for many radiation therapy applications. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity

Purpose: Motion artifacts are common in patient four-dimensional computed tomography (4DCT) images, leading to an ill-defined tumor volume with large variations for radiotherapy treatment and a poor foundation with low imaging fidelity for studying respiratory motion. The authors developed a method to estimate 4DCT image quality by establishing a correlation between the severity of motion artifacts in 4DCT images and the periodicity of the corresponding 1D respiratory waveform (1DRW) used for phase binning in 4DCT reconstruction. Methods: Discrete Fourier transformation (DFT) was applied to analyze 1DRW periodicity. The breathing periodicity index (BPI) was defined as the sum of the largest five Fourier coefficients, ranging from 0 to 1. Distortional motion artifacts (excluding blurring) of cine-scan 4DCT at the junctions of adjacent couch positions around the diaphragm were classified in three categories: incomplete, overlapping, and duplicate anatomies. To quantify these artifacts, discontinuity of the diaphragm at the junctions was measured in distance and averaged along six directions in three orthogonal views. Artifacts per junction (APJ) across the entire diaphragm were calculated in each breathing phase and phase-averaged APJ{sup ¯}, defined as motion-artifact severity (MAS), was obtained for each patient. To make MAS independent of patient-specific motion amplitude, two new MAS quantities were defined: MAS{sup D} is normalized to the maximum diaphragmatic displacement and MAS{sup V} is normalized to the mean diaphragmatic velocity (the breathing period was obtained from DFT analysis of 1DRW). Twenty-six patients’ free-breathing 4DCT images and corresponding 1DRW data were studied. Results: Higher APJ values were found around midventilation and full inhalation while the lowest APJ values were around full exhalation. The distribution of MAS is close to Poisson distribution with a mean of 2.2 mm. The BPI among the 26 patients was calculated with a value ranging from 0.25 to 0.93. The DFT calculation was within 3 s per 1DRW. Correlations were found between 1DRW periodicity and 4DCT artifact severity: −0.71 for MAS{sup D} and −0.73 for MAS{sup V}. A BPI greater than 0.85 in a 1DRW suggests minimal motion artifacts in the corresponding 4DCT images. Conclusions: The breathing periodicity index and motion-artifact severity index are introduced to assess the relationship between 1DRW and 4DCT. A correlation between 1DRW periodicity and 4DCT artifact severity has been established. The 1DRW periodicity provides a rapid means to estimate 4DCT image quality. The rapid 1DRW analysis and the correlative relationship can be applied prospectively to identify irregular breathers as candidates for breath coaching prior to 4DCT scan and retrospectively to select high-quality 4DCT images for clinical motion-management research.

60 APPLIED LIFE SCIENCES↗

High-resolution diffraction microscopy using the plane-wave field of a nearly diffraction limited focused x-ray beam

X-ray waves in the center of the beam waist of nearly diffraction limited focused x-ray beams can be considered to have amplitude and phase that are both almost uniform, i.e., they are x-ray plane waves. Here we report the results of an experimental demonstration of high-resolution diffraction microscopy using the x-ray plane wave of the synchrotron x-ray beam focused using Kirkpatrik-Baez mirrors. A silver nanocube with an edge length of {approx}100 nm is illuminated with the x-ray beam focused to a {approx}1 {mu}m spot at 12 keV. A high-contrast symmetric diffraction pattern of the nanocube is observed in the forward far field. An image of the nanocube is successfully reconstructed by an iterative phasing method and its half-period resolution is 3.0 nm. This method does not only dramatically improve the spatial resolution of x-ray microscopy but also is a key technology for realizing single-pulse diffractive imaging using x-ray free-electron lasers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the Preconditioning of a Newton-Krylov Solver for a High-Order reconstructed Discontinuous Galerkin Discretization of All-Speed Compressible Flow with Phase Change for Application in Laser-Based Additive Manufacturing

This dissertation focuses on the development of a fully-implicit, high-order compressible ow solver with phase change. The work is motivated by laser-induced phase change applications, particularly by the need to develop large-scale multi-physics simulations of the selective laser melting (SLM) process in metal additive manufacturing (3D printing). Simulations of the SLM process require precise tracking of multi-material solid-liquid-gas interfaces, due to laser-induced melting/ solidi cation and evaporation/condensation of metal powder in an ambient gas. These rapid density variations and phase change processes tightly couple the governing equations, requiring a fully compressible framework to robustly capture the rapid density variations of the ambient gas and the melting/evaporation of the metal powder. For non-isothermal phase change, the velocity is gradually suppressed through the mushy region by a variable viscosity and Darcy source term model. The governing equations are discretized up to 4th-order accuracy with our reconstructed Discontinuous Galerkin spatial discretization scheme and up to 5th-order accuracy with L-stable fully implicit time discretization schemes (BDF2 and ESDIRK3-5). The resulting set of non-linear equations is solved using a robust Newton-Krylov method, with the Jacobian-free version of the GMRES solver for linear iterations. Due to the sti nes associated with the acoustic waves and thermal and viscous/material strength e ects, preconditioning the GMRES solver is essential. A robust and scalable approximate block factorization preconditioner was developed, which utilizes the velocity-pressure (vP) and velocity-temperature (vT) Schur complement systems. This multigrid block reduction preconditioning technique converges for high CFL/Fourier numbers and exhibits excellent parallel and algorithmic scalability on classic benchmark problems in uid dynamics (lid-driven cavity ow and natural convection heat transfer) as well as for laser-induced phase change problems in 2D and 3D.

42 ENGINEERING↗

Recordings and Analysis of Atomic Ledge and Dislocation Movements in InGaAs to Nickelide Nanowire Phase Transformation

The formation of low resistance and self‐aligned contacts with thermally stable alloyed phases is a prerequisite for realizing reliable functionality in ultrascaled semiconductor transistors. Detailed structural analysis of the phase transformation accompanying contact alloying can facilitate contact engineering as transistor channels approach a few atoms across. Original in situ heating transmission electron microscopy studies are carried out to record and analyze the atomic scale dynamics of contact alloy formation between Ni and In 0.53 Ga 0.47 As nanowire channels. It is observed that the nickelide reacts on the In 0.53 Ga 0.47 As (111) || Ni 2 In 0.53 Ga 0.47 As (0001) interface with atomic ledge propagation along the Ni 2 In 0.53 Ga 0.47 As direction. Ledges nucleate as a train of strained single‐bilayers and propagate in‐plane as double‐bilayers that are associated with a misfit dislocation of . The atomic structure is reconstructed to explain this phase transformation that involves collective gliding of three Shockley partials in In 0.53 Ga 0.47 As lattice to cancel out shear stress and the formation of misfit dislocations to compensate the large lattice mismatch in the newly formed nickelide phase and the In 0.53 Ga 0.47 As layers. This work demonstrates the applicability of interfacial disconnection (ledge + dislocation) theory in a nanowire channel during thermally induced phase transformation that is typical in metal/III–V semiconductor reactions.

Chen, Renjie↗

Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure

Purpose: Accurate knowledge of cardiac quiescence is crucial to the performance of many cardiac imaging modalities, including computed tomography coronary angiography (CTCA). To accurately quantify quiescence, a method for detecting the quiescent periods of the heart from retrospective cardiac computed tomography (CT) using a correlation-based, phase-to-phase deviation measure was developed. Methods: Retrospective cardiac CT data were obtained from 20 patients (11 male, 9 female, 33–74 yr) and the left main, left anterior descending, left circumflex, right coronary artery (RCA), and interventricular septum (IVS) were segmented for each phase using a semiautomated technique. Cardiac motion of individual coronary vessels as well as the IVS was calculated using phase-to-phase deviation. As an easily identifiable feature, the IVS was analyzed to assess how well it predicts vessel quiescence. Finally, the diagnostic quality of the reconstructed volumes from the quiescent phases determined using the deviation measure from the vessels in aggregate and the IVS was compared to that from quiescent phases calculated by the CT scanner. Three board-certified radiologists, fellowship-trained in cardiothoracic imaging, graded the diagnostic quality of the reconstructions using a Likert response format: 1 = excellent, 2 = good, 3 = adequate, 4 = nondiagnostic. Results: Systolic and diastolic quiescent periods were identified for each subject from the vessel motion calculated using the phase-to-phase deviation measure. The motion of the IVS was found to be similar to the aggregate vessel (AGG) motion. The diagnostic quality of the coronary vessels for the quiescent phases calculated from the aggregate vessel (P{sub AGG}) and IVS (P{sub IV} {sub S}) deviation signal using the proposed methods was comparable to the quiescent phases calculated by the CT scanner (P{sub CT}). The one exception was the RCA, which improved for P{sub AGG} for 18 of the 20 subjects when compared to P{sub CT} (P{sub CT} = 2.48; P{sub AGG} = 2.07, p = 0.001). Conclusions: A method for quantifying the motion of specific coronary vessels using a correlation-based, phase-to-phase deviation measure was developed and tested on 20 patients receiving cardiac CT exams. The IVS was found to be a suitable predictor of vessel quiescence. The diagnostic quality of the quiescent phases detected by the proposed methods was comparable to those calculated by the CT scanner. The ability to quantify coronary vessel quiescence from the motion of the IVS can be used to develop new CTCA gating techniques and quantify the resulting potential improvement in CTCA image quality.

60 APPLIED LIFE SCIENCES↗

Time-Dependent Phase-Space Mapping of Space-Charge-Dominated Beams

In this paper we report on a proof of principle experiment for demonstrating the possibility of reconstructing the time resolved-phase-space distribution of a space-charge dominated beam by a tomographic technique which provides us with far more information than a time-sliced emittance. We emphasize that this work describes and demonstrates a new methodology which can be applicable to any beam pulse using imaging methods with the appropriate time resolution for the pulse duration. The combination of a high precision tomographic diagnostic with fast imaging screens and a gated camera are used to produce phase space maps of two beams: one with a parabolic current profile and another with a short perturbation atop a rectangular pulse. The correlations between longitudinal and transverse phase spaces are apparent and their impact on the dynamics is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Testing Lyα Emission-line Reconstruction Routines at Multiple Velocities in One System

The 1215.67 Å H ו Lyα emission line dominates the ultraviolet flux of low-mass stars, including the majority of known exoplanet hosts. Unfortunately, strong attenuation by the interstellar medium (ISM) obscures the line core in most stars, requiring the intrinsic Lyα flux to be reconstructed based on fits to the line wings. We present a test of the widely used Lyα emission-line reconstruction code ւʏᴀᴘʏ using phase-resolved, medium-resolution STIS G140M observations of the close white dwarf–M dwarf binary EG UMa. The Doppler shifts induced by the binary orbital motion move the Lyα emission line in and out of the region of strong ISM attenuation. Reconstructions of each spectrum should produce the same Lyα profile regardless of phase, under the well-justified assumption that there is no intrinsic line variability between observations. Instead, we find that the reconstructions underestimate the Lyα flux by almost a factor of 2 for the lowest velocity, most attenuated spectrum, due to a degeneracy between the intrinsic Lyα and ISM profiles. Our results imply that many stellar Lyα fluxes derived from G140M spectra reported in the literature may be underestimated, with potential consequences for, for example, estimates of extreme-ultraviolet stellar spectra and ultraviolet inputs into simulations of exoplanet atmospheres.

M dwarf stars↗

3D reconstruction of the magnetic vector potential using model based iterative reconstruction

Lorentz transmission electron microscopy (TEM) observations of magnetic nanoparticles contain information on the magnetic and electrostatic potentials. Vector field electron tomography (VFET) can be used to reconstruct electromagnetic potentials of the nanoparticles from their corresponding LTEM images. The VFET approach is based on the conventional filtered back projection approach to tomographic reconstructions and the availability of an incomplete set of measurements due to experimental limitations means that the reconstructed vector fields exhibit significant artifacts. In this paper, we outline a model-based iterative reconstruction (MBIR) algorithm to reconstruct the magnetic vector potential of magnetic nanoparticles. We combine a forward model for image formation in TEM experiments with a prior model to formulate the tomographic problem as a maximum a-posteriori probability estimation problem (MAP). The MAP cost function is minimized iteratively to determine the vector potential. Here, a comparative reconstruction study of simulated as well as experimental data sets show that the MBIR approach yields quantifiably better reconstructions than the VFET approach.

36 MATERIALS SCIENCE↗

The potential for intensity interferometry with {gamma}-ray telescope arrays

Intensity interferometry exploits a quantum optical effect in order to measure objects with extremely small angular scales. The first experiment to use this technique was the Narrabri intensity interferometer, which was successfully used in the 1970s to measure 32 stellar diameters at optical wavelengths; some as small as 0.4 milli-arcseconds. The advantage of this technique, in comparison with Michelson interferometers, is that it requires only relatively crude, but large, light collectors equipped with fast (nanosecond) photon detectors. Ground-based {gamma}-ray telescope arrays have similar specifications, and a number of these observatories are now operating worldwide, with more extensive installations planned for the future. These future instruments (CTA, AGIS, completion 2015) with 30-90 telescopes will provide 400-4000 different baselines that range in length between 50 m and a kilometre. Intensity interferometry with such arrays of telescopes attains 50 {mu}-arcsecond resolution for a limiting m{sub v}{approx}8.5. Phase information can be extracted from the interferometric measurement with phase closure, allowing image reconstruction. This technique opens the possibility of a wide range of studies amongst others, probing the stellar surface activity and the dynamic AU scale circumstellar environment of stars in various crucial evolutionary stages. Here we focuse on the astrophysical potential of an intensity interferometer utilising planned new {gamma}-ray instrumentation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional hard X-ray ptychographic reflectometry imaging on extended mesoscopic surface structures

Many nanodevices and quantum devices, with their sizes often spanning from millimeters down to sub-nanometer, have intricate low-dimensional, non-uniform, or hierarchical structures on surfaces and interfaces. Since their functionalities are dependent on these structures, high-resolution surface-sensitive characterization becomes imperative to gain a comprehensive understanding of the function–structure relationship. We thus developed hard x-ray ptychographic reflectometry imaging, a new technique that merges the high-resolution two-dimensional imaging capabilities of hard x-ray ptychography for extended objects, with the high-resolution depth profiling capabilities of x-ray reflectivity for layered structures. The synergy of these two methods fully leverages both amplitude and phase information from ptychography reconstruction to not only reveal surface topography and localized structures, such as shapes and electron densities, but also yields statistical details, such as interfacial roughness that is not readily accessible through coherent imaging solely. The hard x-ray ptychographic reflectometry imaging is well-suited for three-dimensional imaging of mesoscopic samples, particularly those comprising planar or layered nanostructures on opaque supports, and could also offer a high-resolution surface metrology and defect analysis on semiconductor devices, such as integrated nanocircuits and lithographic photomasks for microchip fabrications.

47 OTHER INSTRUMENTATION↗

Tomography of longitudinal phase space linearization for the generation of attosecond electron bunches

The generation of electron bunches on the attosecond timescale is important for a multitude of accelerator-based applications. Here, we report on a tomographic measurement of the (pre)linearized longitudinal phase space of a low charge 3 MeV electron bunch generated with the 1.6 cell Pegasus photoinjector for the generation of attosecond bunches. The nonlinear correlations in the longitudinal phase space induced by space charge at the photocathode, radiofrequency field curvature of the gun, and vacuum dispersion are compensated using a compact X-band linearizer. Then, the initial and compensated phase of the picosecond electron bunch is precisely reconstructed by neural network assisted tomographic reconstruction from momentum spectra at varying buncher linac phase. Finally, we combine the measured phase space shape with particle tracking simulations to show that electron bunches as short as 941 as develop downstream the beamline.

Beam control↗

Detecting atmospheric neutrino oscillations in the ATLAS detector at CERN

We discuss the possibility to study oscillations of atmospheric neutrinos in the ATLAS experiment at CERN. Because of the large total detector mass, a significant number of events is expected, and during the shutdown phases of the LHC, reconstruction of these events will be possible with very good energy and angular resolutions, and with charge identification. We argue that 500 live days of neutrino running could be achieved, and that a total of {approx}160 contained {nu}{sub {mu}} events and {approx}360 upward going muons could be collected during this time. Despite the low statistics, the excellent detector resolution will allow for an unambiguous confirmation of atmospheric neutrino oscillations and for measurements of the leading oscillation parameters. Though our detailed simulations show that the sensitivity of ATLAS is worse than that of dedicated neutrino experiments, we demonstrate that more sophisticated detectors, e.g. at the ILC, could be highly competitive with upcoming superbeam experiments, and might even give indications for the mass hierarchy and for the value of {theta}{sub 13}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗