Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

New experimental possibility to search for the ratio of a possible T-violating amplitude to the weak-interaction amplitude in polarized neutron transmission through a polarized nuclear target

This paper considers a spin-dependent neutron interaction with optical potentials (fields) from the strong interaction, the weak interaction, and an assumed T-violating interaction. The vector sum of these fields and their interferences determines an effective field of the target with an angular position in space due to polar and azimuthal angles. The phase of the azimuthal component is found to be the sum of two angles. The tangent of the first angle is equal to the ratio of the T-violating forward-scattering amplitude D to the weak-interaction amplitude C. The quantity is of interest. The tangent of the second angle depends on the spin rotation in the residual pseudomagnetic field of the target, and it can be treated as a background effect. This paper shows that the second angle has different signs in measurements with polarized and unpolarized neutrons; thus, two measurements allow it to be compensated for. In addition, the use of the Ramsey method of separated oscillatory fields for measurement of the neutron spin rotation angle, depending on the phase of the rf field in the Ramsey cell, allows a cosine-like spectrum to be measured. This spectrum is called a phase spectrum. The phase spectra measured with polarized and unpolarized targets have a phase shift. The measurements of this phase shift with polarized and nonpolarized neutrons at a p-wave resonance enable the ratio D/C to be isolated. We also describe the algorithm for separating the ratio D/C, taking into account the influence of the fringing fields of the Ramsey coil magnet and the target magnet.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mutual synchronization of two stacks of intrinsic Josephson junctions in cuprate superconductors

Certain high-T{sub c} cuprate superconductors, which naturally realize a stack of Josephson junctions, thus can be used to generate electromagnetic waves in the terahertz region. A plate-like single crystal with 10{sup 4} junctions without cavity resonance was proposed to achieve strong radiation. For this purpose, it is required to synchronize the Josephson plasma oscillation in all junctions. In this work, we propose to use two stacks of junctions shunted in parallel to achieve synchronization. The two stacks are mutually synchronized in the whole IV curve, and there is a phase shift between the plasma oscillation in the two stacks. The phase shift is nonzero when the number of junctions in different stacks is the same, while it can be arbitrary when the number of junctions is different. This phase shift can be tuned continuously by applying a magnetic field when all the junctions are connected by superconducting wires.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase Demodulation by Frequency Chirping in Coherence Microwave Photonic Interferometry

This paper presents a signal processing method to demodulate the optical interference phase of cascaded individual optical fiber intrinsic Fabry-Perot interferometric (IFPI) sensors in a coherent microwave-photonic interferometry (CMPI) distributed sensing system. The new method utilizes the chirp effect of electro-optic modulator (EOM) to create a quasi-quadrature optical interference phase shift between two adjacent pulses which correspond to two adjacent reflection points in the time domain. The phase shift can be controlled by adjusting the bias voltage that is applied to the EOM. The interference phase is calculated by elliptically fitting the phase shift. The interference phase change is proportional to the optical path difference (OPD) change of the interferometer, and the sign can be used to differentiate the increase or decrease of the OPD. The method is demonstrated for distributed strain sensing, showing good linearity, high resolution and large dynamic range.

42 ENGINEERING↗

Quantum enhanced magneto-optical microscopy and spectroscopy

A system comprising a nonlinear medium (NLM), an optical transduction module, a dual homodyne detector and a processor is provided. The NLM receives at least a pump beam and issues the pump, probe and conjugate beams, where the beams are linearly polarized. Optics route the probe, the conjugate or both beams to the sample. The sample imparts polarization rotation to light that interacts therewith. The optical transduction module imparts to the interacted light an optical phase shift that is a 1:1 transduction of the polarization rotation, where at least one of the probe light or the conjugate light carries the imparted optical phase shift. The processor obtains the optical-phase shift based on respective detection signals from the dual homodyne detector and determines, based on the obtained optical-phase shift, at least one of a Faraday polarization rotation, a Kerr polarization rotation or a spin noise spectrum.

Lawrie, Benjamin J.↗

Leipzig University W-Band Cloud Radar, Gothic (Colorado), SAIL Campaign Second Winter (15.11.2022 - 05.06.2023)

The instrument is a polarimetric W-Band simultaneous transmission simultaneous reception (STSR) Doppler Cloud Radar manufactured by Radiometer Physics GmbH (RPG, instrument type RPG-FMCW-94-DP). It was deployed about 500m away from the ARM M1 facility in Gothic (CO) near the Ore House between Nov 15, 2022 and Jun 5, 2023 at an altitude of 2913 m. The Doppler cloud radar was mounted on a prototype of a cold temperature scanner manufactured by RPG. The dataset contains common radar variables like equivalent radar reflectivity factor, mean Doppler velocity, Doppler spectrum width as well as common polarimetric radar variables like differential phase shift (PhiDP), specific differential phase shift (KDP), correlation coefficient (RHV) and differential reflectivity (ZDR). Between Nov 15, 2022, and Feb 7, 2023 the radar was operated at 40° constant elevation and 151° azimuth (towards the KAZR at the AMF1). Between Feb 7 and Mar 15, 2023 the following scan cycle was repeated in 15min intervals: zenith pointing measurements, RHI scans from 0° to 90° and 90° to 0° elevation at 151° azimuth, constant elevation measurements at 40° elevation and 151° azimuth and PPI scans at 85° elevation for wind retrievals (one PPI per hour). Between Mar 15 18:18 UTC and Apr 8, 2023 11:04 UTC, the scanner was stuck at 72° elevation, which resulted in corrupted files for this period. For that period, the files containing data are uploaded but should be treated with care. Between Apr 8 and Apr 14, 2023 the scanning pattern described above was performed again. Afterwards, except for May 17 and May 18, 2023 where scanning patterns as described above were performed, measurements continued at 40° elevation and 151° azimuth until May 22, 2023 09:00 UTC. The scanning pattern was then started again, but without hourly PPI measurements until May 31, 2023. Between May 31 and Jun 5, 2023 solely zenith-pointing observations were performed. The data provided here are the RPG Level 1 (L1) files, Doppler spectra Level 0 (L0) files are available upon request.

54 ENVIRONMENTAL SCIENCES↗

Inducing jet-lag in older people: directional asymmetry

Twenty healthy elderly subjects (12 female, 8 male; mean age 81 years, range 67-87 years) each experienced a 15-day time isolation protocol in which they lived individually in a special laboratory apartment in which sleep and circadian rhythm measures could be taken. There were two experiments: one (6 females, 4 males) involved a 6-h phase advance of the sleep/wake cycle, and the other (6 females, 4 males) a 6-h phase delay. Each started with 5 baseline days, immediately followed by the phase shift. The subject was then held to the phase shifted routine for the remainder of the study. Rectal temperatures were recorded minute-by-minute throughout the entire experiment and each night of sleep was recorded using polysomnography. A directional asymmetry in phase-shift effects was apparent, with significantly more sleep disruption and circadian rhythm amplitude disruption after the phase advance than after the phase delay. Sleep disruption was reflected in reduced time spent asleep, and in changed REM latency, which increased in the phase advance direction but decreased in the phase delay direction. Although the phase advance led to a significant increase in wakefulness in the first half of the night, the phase delay did not lead to an equivalent increase in wakefulness during the second half of the night. Examination of both raw and 'demasked' circadian rectal temperature rhythms confirmed that phase adjustment was slow in both directions, but was less slow (and more monotonic) after the phase delay than after the phase advance. Subjective alertness suffered more disruption after the phase advance than after the phase delay.

NASA Discipline Regulatory Physiology↗

Array Phase Shifters: Theory and Technology

While there are a myriad of applications for microwave phase shifters in instrumentation and metrology, power combining, amplifier linearization, and so on, the most prevalent use is in scanning phased-array antennas. And while this market continues to be dominated by military radar and tracking platforms, many commercial applications have emerged in the past decade or so. These new and potential applications span low-Earth-orbit (LEO) communications satellite constellations and collision warning radar, an aspect of the Intelligent Vehicle Highway System or Automated Highway System. In any case, the phase shifters represent a considerable portion of the overall antenna cost, with some estimates approaching 40 percent for receive arrays. Ferrite phase shifters continue to be the workhorse in military-phased arrays, and while there have been advances in thin film ferrite devices, the review of this device technology in the previous edition of this book is still highly relevant. This chapter will focus on three types of phase shifters that have matured in the past decade: GaAs MESFET monolithic microwave integrated circuit (MMIC), micro-electromechanical systems (MEMS), and thin film ferroelectric-based devices. A brief review of some novel devices including thin film ferrite phase shifters and superconducting switches for phase shifter applications will be provided. Finally, the effects of modulo 2 phase shift limitations, phase errors, and transient response on bit error rate degradation will be considered.

Romanofsky, Robert R.↗

Bit Error Rate and Frame Error Rate Data Processing for Space Communications and Navigation-Related Communication System Analysis Tools

One of the capabilities that the Space Communications and Navigation (SCaN) Strategic Center for Networking, Integration, and Communications (SCENIC) user interface (UI) web application intends to provide its users is the addition of network protocol and link encryption augmentations of communication system analyses. Before any of these analyses capabilities can be modeled, the simulations of bit error rate (BER) and frame error rate (FER) against signal-to-noise ratio (SNR) have been conducted, requiring parameters from several known coding types (low-density parity-check (LDPC), convolutional, etc.), signal modulations (binary phase shift keying (BPSK), quadrature phase shift keying (QPSK), etc.), coding rates (1/2, 1/3, etc.), and frame sizes (1,280, 3,580, etc.). However, in order to extract useful information from the results of these simulations, a curve fitting technique has been applied to each resulting dataset to extend and extrapolate the curve fit of BER and FER down to 10–30 using MATLAB® Curve Fitting Toolbox™ (The MathWorks, Inc.). This is a necessary step because simulations of BER and FER were only performed to around 10–9 due to the extensive simulation time that would be required to obtain significant simulation results at the error levels desired. Furthermore, the fitted curve results were applied to a finer resolution for the SNR at 0.01-dB interval instead of the 0.05-dB interval limitation used in the simulation. All the possible combinations of the coding types, signal modulations, coding rates, frame sizes, and the extension of BER and FER curves would enable users to capture a wide range of link performances that directly relates to the addition of higher level networking data encapsulated in a frame. The curve fitting results also led to the modeling of the optical link error rate performance by solving for coding gain, FER_BER SNR delta, coded optical BER-SNR, and coded optical FER–SNR.

Communication link analysis↗

The shock-induced star formation sequence resulting from a constant spiral pattern speed

We utilize a suite of multiwavelength data of nine nearby spirals to analyze the shock-induced star formation sequence that may result from a constant spiral pattern speed. The sequence involves tracers as the H I, CO 24 μm, and FUV, where the spiral arms were analyzed with Fourier techniques in order to obtain their azimuthal phases as a function of radius. It was found that only two of the objects, NGC 628 and NGC 5194, present coherent phases resembling the theoretical expectations, as indicated by the phase shifts of CO- 24 μm. The evidence is more clear for NGC 5194 and moderate for NGC 628. It was also found that the phase shifts are different for the two spiral arms. With the exception on NGC 3627, a two-dimensional Fourier analysis showed that the rest of the objects do not exhibit bi-symmetric spiral structures of stellar mass, i.e., grand-design spirals. A phase order inversion indicates a corotation radius of ∼89'' for NGC 628 and ∼202'' for NGC 5194. For these two objects, the CO-Hα phase shifts corroborate the CO-24 μm azimuthal offsets. Also for NGC 5194, the CO-70 μm, CO-140 μm, and CO-250 μm phase shifts indicate a corotation region.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonperturbative Zou-Wang-Mandel effect

The Zou-Wang-Mandel (ZWM) effect is a remarkable consequence of photon indistinguishability and continuous-variable entanglement in which an optical phase shift is imprinted on photonic modes associated with optical paths that that do not pass through the phase shift source. By bringing the canonical formalism of continuous-variable Gaussian states to bear on the mode-structure of the ZWM experiment, we show that the physical consequence of implementing optical path identity is a renormalization of quadrature squeezing which governs the entanglement of four effective optical modes. Nonperturbative expressions for the ZWM interference patterns and normalized first-order coherence function are derived. Generalizations to $\mathscr{H}$-graph states with more than four modes directly follow from the general method used to analyze the minimal example. Here, we show that a ZWM interferometer with a laser-seeded signal mode, which estimates an idler phase shift by detecting photons that did not propagate through the phase shift, exhibits an optimal sensitivity comparable to that of a laser-seeded SU(1,1) interferometer if path identity is implemented with high fidelity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Multichannel microwave interferometer for the levitated dipole experiment

A four-channel microwave interferometer (center frequency: 60 GHz) has been constructed to measure plasma density profiles in the levitated dipole experiment (LDX). The LDX interferometer has a unique design owing to the unique geometry of LDX. The main design features of the interferometer are: (1) the transmitted beam traverses the plasma entirely in O-mode; (2) the interferometer is a heterodyne system employing two free-running oscillators; (3) four signals of data are received from just on transmitted beam; (4) phase shifts are detected in quadrature. Calibration tests demonstrate that the interferometer measures phase shifts with an uncertainty of approximately 5 deg. Plasma densities in LDX corresponding to phase shifts of up to 5{pi} are routinely and successfully measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time domain phase measuring apparatus

The phase and/or period stability of a device is determined by connecting the device in one orthogonal arm of a phase detector having a mixer. In the other arm is an adjustable, variable phase shift device. The output of the mixer is fed through an active low pass filter to derive a DC voltage indicative of the phase shift. The variable phase device is adjusted so that the DC voltage will nullify the phase shift of the tested device under normal conditions. The DC voltage level is converted into a time interval indicative of the phase change of the tested device by determining when the level equals the amplitude of a low frequency ramp voltage. The interval between adjacent equality points can be measured or the period between a reference point on the ramp voltage and the quality be measured.

Reinhardt, V. S.↗

Electron-Hydrogen Elastic Scattering

Scattering by single-electron systems is always of interest because the wave function of the target is known exactly. Various approximations have been employed to take into account distortion produced in the target. Among them are the method of polarized orbitals and the close coupling approximation. Recently, e-H and e-He+ S-wave scattering in the elastic region has been studied using the Feshbach projection operator formalism. In this approach, the usual Hartree-Fock and exchange potentials are augmented by an optical potential and the resulting phase shifts have rigorous lower bounds. Now this method is being applied to the e-H P-wave scattering in the elastic region. The number of terms in the Hylleraas-type wave function for the 1,3 P phase shifts is 84 and the resulting phase shifts (preliminary) are given. The results have been given up to five digits because to that accuracy they are rigorous lower bounds. They are in general agreement with the variational (VAR) results of Armstead, and those obtained from the intermediate energy R-matrix method (RM) of Scholz et al., and the finite element method (FEM) of Botero and Shertzer. The later two methods do not provide any bounds on phase shifts.

Bhatia, A. K.↗

Electron-H P-Wave Elastic Scattering

In previous papers [Bhatia and Temkin, Phys. Rev. A 64, 032709-1 (2001), Phys. Rev. A 66, 064702 (2002)], electron-hydrogen and electron-He(+) S-wave scattering phase shifts were calculated using the optical potential approach. This method is now extended to the singlet and triplet electron-H P-wave scattering in the elastic region. Phase shifts are calculated using Hylleraas-type correlation functions with up to 220 terms. Results are rigorous lower bounds to the exact phase shifts and they are compared to phase shifts obtained from previous calculations.

Bhatia, A. K.↗

Combined mixed approach algorithm for in-line phase-contrast x-ray imaging

Purpose: In the past decade, phase-contrast imaging (PCI) has been applied to study different kinds of tissues and human body parts, with an increased improvement of the image quality with respect to simple absorption radiography. A technique closely related to PCI is phase-retrieval imaging (PRI). Indeed, PCI is an imaging modality thought to enhance the total contrast of the images through the phase shift introduced by the object (human body part); PRI is a mathematical technique to extract the quantitative phase-shift map from PCI. A new phase-retrieval algorithm for the in-line phase-contrast x-ray imaging is here proposed. Methods: The proposed algorithm is based on a mixed transfer-function and transport-of-intensity approach (MA) and it requires, at most, an initial approximate estimate of the average phase shift introduced by the object as prior knowledge. The accuracy in the initial estimate determines the convergence speed of the algorithm. The proposed algorithm retrieves both the object phase and its complex conjugate in a combined MA (CMA). Results: Although slightly less computationally effective with respect to other mixed-approach algorithms, as two phases have to be retrieved, the results obtained by the CMA on simulated data have shown that the obtained reconstructed phase maps are characterized by particularly low normalized mean square errors. The authors have also tested the CMA on noisy experimental phase-contrast data obtained by a suitable weakly absorbing sample consisting of a grid of submillimetric nylon fibers as well as on a strongly absorbing object made of a 0.03 mm thick lead x-ray resolution star pattern. The CMA has shown a good efficiency in recovering phase information, also in presence of noisy data, characterized by peak-to-peak signal-to-noise ratios down to a few dBs, showing the possibility to enhance with phase radiography the signal-to-noise ratio for features in the submillimetric scale with respect to the attenuation-based imaging. Conclusions: It has been shown that phase-retrieved radiographies can be used both to have quantitative phase information about soft tissues, complementary to the attenuation information, and to enhance the visibility of details inside soft tissues, with higher efficiency with respect to phase radiography.

60 APPLIED LIFE SCIENCES↗

Understanding Anomalous Gas-Phase Peak Shifts in Dip-and-Pull Ambient Pressure XPS Experiments

Dip-and-pull ambient pressure X-ray photoelectron spectroscopy (AP-XPS) holds promise to uncover elementary processes of (photo)electrochemistry. We show, however, that the sample for such experiments should preferably be nonporous and the potential on the surface homogeneous. We carried out dip-and-pull AP-XPS experiments on a hematite thin film sample under the photoelectrochemical oxygen evolution reaction (OER) and find unexpected O 1s core level shifts. Upon electrochemical biasing under simulated solar light illumination, the gas-phase water peak shifted more than the electrolyte peak. To uncover the origin of the unexpected larger shift of the gas-phase peak, we performed electrostatic simulations using COMSOL, to map the potential field in the relevant volume between the sample and the first aperture of the XPS spectrometer. A number of geometric models were considered. We find that when the potential on the sample surface is inhomogeneous, e.g., with ionically isolated electrolyte patches, the gas-phase peak of the spectrum can shift more than the peak due to the electrolyte film. This suggests that at the measured sample position, the local potential was not as set by the potentiostat. Despite this, we find reversible consumption and replenishment of hydroxide in the spectra, which, due to OH– being the reactant of the OER in alkaline electrolyte, makes sense chemically. We propose that this is linked to OH– diffusion across the measured sample position, driven by the potential dependent consumption and replenishment of OH– at the nearby well-connected surface regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cluster virial expansion for the equation of state of partially ionized hydrogen plasma

We study the contribution of electron-atom interaction to the equation of state for partially ionized hydrogen plasma using the cluster-virial expansion. We use the Beth-Uhlenbeck approach to calculate the second virial coefficient for the electron-atom (bound cluster) pair from the corresponding scattering phase shifts and binding energies. Experimental scattering cross-sections as well as phase shifts calculated on the basis of different pseudopotential models are used as an input for the Beth-Uhlenbeck formula. By including Pauli blocking and screening in the phase shift calculation, we generalize the cluster-virial expansion in order to cover also near solid density plasmas. We present results for the electron-atom contribution to the virial expansion and the corresponding equation of state, i.e. pressure, composition, and chemical potential as a function of density and temperature. These results are compared with semiempirical approaches to the thermodynamics of partially ionized plasmas. Avoiding any ill-founded input quantities, the Beth-Uhlenbeck second virial coefficient for the electron-atom interaction represents a benchmark for other, semiempirical approaches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative comparison of direct phase retrieval algorithms in in-line phase tomography

A well-known problem in x-ray microcomputed tomography is low sensitivity. Phase contrast imaging offers an increase of sensitivity of up to a factor of 10{sup 3} in the hard x-ray region, which makes it possible to image soft tissue and small density variations. If a sufficiently coherent x-ray beam, such as that obtained from a third generation synchrotron, is used, phase contrast can be obtained by simply moving the detector downstream of the imaged object. This setup is known as in-line or propagation based phase contrast imaging. A quantitative relationship exists between the phase shift induced by the object and the recorded intensity and inversion of this relationship is called phase retrieval. Since the phase shift is proportional to projections through the three-dimensional refractive index distribution in the object, once the phase is retrieved, the refractive index can be reconstructed by using the phase as input to a tomographic reconstruction algorithm. A comparison between four phase retrieval algorithms is presented. The algorithms are based on the transport of intensity equation (TIE), transport of intensity equation for weak absorption, the contrast transfer function (CTF), and a mixed approach between the CTF and TIE, respectively. The compared methods all rely on linearization of the relationship between phase shift and recorded intensity to yield fast phase retrieval algorithms. The phase retrieval algorithms are compared using both simulated and experimental data, acquired at the European Synchrotron Radiation Facility third generation synchrotron light source. The algorithms are evaluated in terms of two different reconstruction error metrics. While being slightly less computationally effective, the mixed approach shows the best performance in terms of the chosen criteria.

62 RADIOLOGY AND NUCLEAR MEDICINE↗