Evaluation of a Large Area, 83 μm Pixel Pitch Amorphous Selenium Indirect Flat Panel Detector
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Abstract not provided.
In this work, we present an uncooled infrared (IR) thermal imager featuring a sparse array of resonant pixels that can be monolithically integrated with the readout electronics for long-term operation in hightemperature environments. Each of the detector pixels is made of an IR-sensitive GaN microresonator developed to be operated at up to 500 0C. The pixels are employed in sparse array configuration to allow for routing the signal carrying traces and to ease the routing from pixel to circuit, as well as to reduce the power consumption. A 128´128 sparse resonator array with the array density of 37.5% is designed and used in conjunction with the Compressed Sensing method to reconstruct complex test images from highly incomplete data. Capabilities and performance metrics of the recovery technique are explored.
The “crosshatch” pattern is a recurring “feature” of HgCdTe arrays, specifically the Teledyne HAWAII family of near infrared detectors. It is a fixed pattern of high frequency QE variations along 3 directions generally thought to be related to the crystal structure of HgCdTe. The pattern is evident in detectors used in WFC3/IR, WISE, JWST, and in candidate detectors for Euclid and WFIRST. Using undersampled point sources projected onto a HAWAII-2RG detector, we show that the pattern induces photometric variations that are not removed by a flat-field calibration, thus demonstrating that the QE variations occur on scales smaller than the 18 micron pixels. Our testbed is the Precision Projector Laboratory’s astronomical scene generator, which can rapidly characterize the full detector by scanning thousands of undersampled spots. If not properly calibrated, detectors showing strong crosshatch may induce correlated errors in photometry, astrometry, spectroscopy, and shape measurements.
SPECTRE-ML (Spectral Peak Enhancement by Combining Trusted Response Elements via Machine Learning) is a machine learning based program for finding optimal clusters of radiation detector segments (i.e., pixels or voxels) in order to improve spectral performance. It provides facilities for pre-processing and analyzing training datasets, running ML algorithms, and evaluating and visualizing outputs. SPECTRE-ML outperforms simpler ad-hoc segmentation methods such as uniform depth clusters, learning detector performance trends such as dead layers, edge effects, and gain shifts. Although extensible to arbitrary highly-segmented spectroscopic radiation detectors, SPECTRE-ML currently focuses on improving spectral performance in highly-segmented CdZnTe (CZT) detectors for International Atomic Energy Agency (IAEA) non-destructive assay (NDA) safeguards tasks.
We present the first physical realization of in-pixel signal processing with integrated AI-based data filtering for particle tracking detectors. Building on prior work that demonstrated a physics-motivated edge-AI algorithm suitable for ASIC implementation, this work marks a significant milestone toward intelligent silicon trackers. Our prototype readout chip performs real-time data reduction at the sensor level while meeting stringent requirements on power, area, and latency. The chip is taped-out in 28nm TSMC CMOS bulk process, which has been shown to have sufficient radiation hardness for particle experiments. This development represents a key step toward enabling fully on-detector edge AI, with broad implications for data throughput and discovery potential in high-rate, high-radiation environments such as the High-Luminosity LHC.
The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 millimeter x 20 millimeter CdTe-based detector with 250 micrometer square pixels (80 x 80 pixels) which achieves 1 kiloelectronvolt FWHM (Full-Width Half-Maximum) @ 60 kiloelectronvolts and gives full spectroscopy between 5 kiloelectronvolts and 200 kiloelectronvolts. An added advantage of these detectors is that they have a full-frame readout rate of 10 kilohertz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1 millimeter-thick CdTe detectors are tiled into a 2 x 2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flight-suitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.
The benefits of Astrophysical X-ray polarization measurements have been discussed in the literature for decades and with respect to a variety of detectors. Despite this, a dedicated polarimeter for the measurement of Astrophysical sources has not flown since the 1970's, when the definitive measurement of the Crab Nebula was made. More recently, an indirect measurement of the polarization of two gamma-ray bursts has been extracted from BATSE data, re-emphasizing the importance of polarization measurements in constraining a physical model. We describe a sensitive and, and extremely versatile, photoelectric polarimeter using a micro-pattern gas detector, with an 80micron pixel ASIC anode, to image the primary photoelectron track. The detector can be optimized to a preferred energy range between 1 keV and 50 keV. We present measurements of polarized 4.5 keV X-rays and unpolarized 6 keV X-rays obtained with a prototype detector using Carbon Dioxide gas.
The arrival of direct electron detectors (DED) with high frame-rates in the field of scanning transmission electron microscopy has enabled many experimental techniques that require collection of a full diffraction pattern at each scan position, a field which is subsumed under the name four dimensional-scanning transmission electron microscopy (4D-STEM). DED frame rates approaching 100 kHz require data transmission rates and data storage capabilities that exceed commonly available computing infrastructure. Current commercial DEDs allow the user to make compromises in pixel bit depth, detector binning or windowing to reduce the per-frame file size and allow higher frame rates. This change in detector specifications requires decisions to be made before data acquisition that may reduce or lose information that could have been advantageous during data analysis. The 4D Camera, a DED with 87 kHz frame-rate developed at Lawrence Berkeley National Laboratory, reduces the raw data to a linear-index encoded electron event representation (EER). Here we show with experimental data from the 4D Camera that linear-index encoded EER and its direct use in 4D-STEM phase contrast imaging methods enables real-time, interactive phase-contrast from large-area 4D-STEM datasets. Furthermore, we detail the computational complexity advantages of the EER and the necessary computational steps to achieve real-time interactive ptychography and center-of-mass differential phase contrast using commonly available hardware accelerators.
The Large Hadron Collider (LHC) particle accelerator at European Center for Nuclear Research (CERN) will be shut down starting in 2026 to achieve the High Luminosity Large Hadron Collider (HL-LHC) upgrade. The upgrade will allow for higher fluences, in order to increase the probability of detecting increasingly rare particles, and to obtain higher precision measurements of known particles. To accommodate the new accelerator conditions, many aspects of the Compact Muon Solenoid (CMS) detector will be upgraded; of particular interest for this thesis are the silicon pixel detectors located in the inner tracker. These will be replaced and upgraded to accommodate the higher fluences of the HL-LHC upgrade, as well as to replace existing sensors which have sustained radiation damage. In order for the new sensors to operate under high luminosity conditions, they must be increasingly radiation hard, and in order to detect rare particles, they must be increasingly more precise. The performance of one Centro Nacional de Microelectronica (CNM) 3D silicon sensor before and after undergoing irradiation at fluences similar to those which will be observed at the HL-LHC was investigated to determine radiation hardness and precision. Data was collected at Fermi National Laboratory (Fermilab), in the Fermi National Laboratory Test Beam Facility (FTBF) silicon tracker telescope, which can be used to determine the number of particles, and tracks made by high energy protons passing through. The sensor was also irradiated at Fermilab in the Irradiation Test Area (ITA). Prior to data collection a tuning procedure is carried out to determine ideal bias voltage operating conditions, mask noisy and dead pixels, adjust to the ideal threshold, and map sensor gain. Data is then collected at the FTBF, where the sensor is installed in the center of the FTBF silicon telescope. Variables, including angle and bias voltage, are varied throughout data collection. Data is then processed using an alignment software to determine the exact telescope geometry, along with the tracks which were observed passing through the sensor and telescope. Sensor performance was found to be comparable before and after irradiation, with irradiated results showing slightly lower efficiencies and cluster sizes. Position resolution is comparable both before and after irradiation, and similar distributions of cluster shape are observed. After irradiation, the sensor shows increasing collected charge with bias, an indication of increased width of the depletion region. Peak charge pre-irradiation is higher than post-irradiation peak charge, indicating the irradiated results are not taken under fully-depleted conditions.
Filled arrays of planar bolometers are finding astronomical applications at wavelengths as long as several millimeters. In an effort to keep focal planes to a reasonable size while maintaining large numbers of detectors, a common strategy is to push these arrays to operate close to or at the single mode limit. Doing so introduces several new challenges that are not experienced in the multi-mode case of far-infrared detectors having similar pixel sizes. First, diffractive effects of the pixels themselves are no longer insignificant and will ultimately contribute to the resolution limit of the optical system in which they reside. We use the method of Withlngton et al. (2003) to model the polarized diffraction in this limit. Second, it is necessary to re-examine the coupling between the radiation and the absorbing element that is thermally connected to the bolometers. The small f-numbers that are often employed to make use of large focal planes makes backshort construction problematic. We introduce a new strategy to increase detector efficiency that uses an antireflective layer on the front side of the detector array. In addition, typical methods for stray light control that rely on multiple reflections in a lossy medium fail due to physical size constraints. For this application, we find that resonant absorbers are a more effective strategy that can be implemented in the space available.
A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location.
A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location. Previously announced in STAR as N82-19118
Photoelectric X-ray polarimeters based on pixel micropattern gas detectors (MPGDs) offer order-of-magnitude improvement in sensitivity over more traditional techniques based on X-ray scattering. This new technique places some of the most interesting astronomical observations within reach of even a small, dedicated mission. The most sensitive instrument would be a photoelectric polarimeter at the focus of 2 a very large mirror, such as the planned XEUS. Our efforts are focused on a smaller pathfinder mission, which would achieve its greatest sensitivity with large-area, low-background, collimated polarimeters. We have recently demonstrated a MPGD polarimeter using amorphous silicon thin-film transistor (TFT) readout suitable for the focal plane of an X-ray telescope. All the technologies used in the demonstration polarimeter are scalable to the areas required for a high-sensitivity collimated polarimeter. Leywords: X-ray polarimetry, particle tracking, proportional counter, GEM, pixel readout
We consider the optimum design of photon-counting microlaser altimeters operating from airborne and spaceborne platforms under both day and night conditions. Extremely compact Q-switched microlaser transmitters produce trains of low energy pulses at multi-kHz rates and can easily generate subnanosecond pulse-widths for precise ranging. To guide the design, we have modeled the solar noise background and developed simple algorithms, based on Post-Detection Poisson Filtering (PDPF), to optimally extract the weak altimeter signal from a high noise background during daytime operations. Practical technology issues, such as detector and/or receiver dead times, have also been considered in the analysis. We describe an airborne prototype, being developed under NASA's instrument Incubator Program, which is designed to operate at a 10 kHz rate from aircraft cruise altitudes up to 12 km with laser pulse energies on the order of a few microjoules. We also analyze a compact and power efficient system designed to operate from Mars orbit at an altitude of 300 km and sample the Martian surface at rates up to 4.3 kHz using a 1 watt laser transmitter and an 18 cm telescope. This yields a Power-Aperture Product of 0.24 W-square meter, corresponding to a value almost 4 times smaller than the Mars Orbiting Laser Altimeter (0. 88W-square meter), yet the sampling rate is roughly 400 times greater (4 kHz vs 10 Hz) Relative to conventional high power laser altimeters, advantages of photon-counting laser altimeters include: (1) a more efficient use of available laser photons providing up to two orders of magnitude greater surface sampling rates for a given laser power-telescope aperture product; (2) a simultaneous two order of magnitude reduction in the volume, cost and weight of the telescope system; (3) the unique ability to spatially resolve the source of the surface return in a photon counting mode through the use of pixellated or imaging detectors; and (4) improved vertical and transverse spatial resolution resulting from both (1) and (3). Furthermore, because of significantly lower laser pulse energies, the microaltimeter is inherently more eyesafe to observers on the ground and less prone to internal optical damage, which can terminate a space mission prematurely.
Neutron imaging is a non-destructive probe that can spatially resolve bulk materials’ internal features/structures. Neutron imaging spatial resolution is driven by detector technology, i.e., pixel size, and is currently on the order of 10–20 µm. This limitation can be alleviated by the use of neutron grating interferometry – an advanced neutron imaging technique – that enables simultaneous access to three contrast mechanisms: attenuation, differential phase, and small-angle neutron scattering. Recently, a Talbot-Lau neutron grating interferometry has been implemented at the Multimodal Advanced Radiography Station at the High Flux Isotope Reactor. In this work, the design, setup and performance of the grating apparatus are presented.
Many members of the tetragonal tungsten bronze (TTB) family of oxides display an incommensurate periodic lattice distortion, the nature of which has been the subject of some controversy. Here we present a study of this structural modulation in the relaxor ferroelectric Ba 5 SmSn 3 Nb 7 O 30 (BSSN) by quantitative scanning transmission electron microscopy (STEM). Additionally, we characterize the modulation in BSSN by employing a fast, pixelated direct electron detector to perform high resolution phase contrast STEM imaging of the crystalline lattice. By quantitatively analyzing the images, we visualize the atomic structural correlations present in the material on both the cation and anion sublattices. This analysis reveals the incommensurate structure to have an octahedral tilting pattern and cooperative A2 site cation displacements, analogous to an Ama2 commensurate cell. Finally, we show that the modulation is composed of a structural motif with a period of 3 x $d_{1\bar{1}0}$ and modified by discommensurations, likely arise from frustrated octahedral tilting in the odd-valued periodicity.
In this work, we present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES). The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal holders that can be easily exchanged, as well as movable alignment eyelets that give flexibility in Bragg angle selection. Designed for ease of manufacture, all the components, except for the apertures, can be 3D printed and readily assembled. We describe its implementation in measurements of resonant and non-resonant Cu Kα and Kβ x-ray emission and report the theoretical and measured energy resolution and collected solid angle of the emission.