Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma Volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Effect of leg exercise training on vascular volumes during 30 days of 6 deg head-down bed rest

In order to investigate the effects of leg exercise training on vascular volumes during 30 d of 6-deg head-down bed rest, plasma and red cell volumes, body density, and water balance were measured in 19 men confined to bed rest (BR). One group had no exercise training (NOE), another near-maximal variable-intensity isotonic exercise (ITE) for 60 min/d, and the third near-maximal intermittent isokinetic exercise (IKE) for 60 min/d. Mean energy costs for the NOE, IKE, and ITE regimens were determined. Body densities within groups and mean urine volumes between groups were unchanged during BR. Changes in red cell volume followed changes in plasma volume. There was close coupling between resting plasma volume and plasma protein and osmotic content. It is argued that the ITE training protocol is better than the IKE protocol for maintaining plasma volume during prolonged exposure to BR.

Greenleaf, J. E.↗

Plasma properties in electron-bombardment ion thrusters

The paper describes a technique for computing volume-averaged plasma properties within electron-bombardment ion thrusters, using spatially varying Langmuir-probe measurements. Average values of the electron densities are defined by integrating the spatially varying Maxwellian and primary electron densities over the ionization volume, and then dividing by the volume. Plasma properties obtained in the 30-cm-diameter J-series and ring-cusp thrusters are analyzed by the volume-averaging technique. The superior performance exhibited by the ring-cusp thruster is correlated with a higher average Maxwellian electron temperature. The ring-cusp thruster maintains the same fraction of primary electrons as does the J-series thruster, but at a much lower ion production cost. The volume-averaged predictions for both thrusters are compared with those of a detailed thruster performance model.

Matossian, J. N.↗

Cyclical tests of selected space shuttle TPS metallic materials in a plasma arc tunnel Volume 1: Description of tests and program summary

Work, concerned with cyclical thermal evaluation of selected space shuttle thermal protection system (TPS) metallic materials in a hypervelocity oxidizing atmosphere that approximated an actual entry environment, is presented. A total of 325 sample test hours were conducted on 21 super-alloy metallic samples at temperatures from 1800 to 2200 F (1256 to 1478 K) without any failures. The 4 x 4 in. (10.2 x 10.2 cm) samples were fabricated from five nickel base alloys and one cobalt base alloy. Eighteen of the samples were cycled 100 times each and the other three samples 50 times each in a test stream emanating from an 8 in. (20.3 cm) diam exit, Mach 4.6, conical nozzle. The test cycle consisted of a 10 min heat pulse to a controlled temperature followed by a 10 min cooldown period. The TD-NiCrAl and TD-NiAlY materials showed the least change in weight, thickness, and physical appearance even though they were subjected to the highest temperature environment.

Rinehart, W. A.↗

Hypervolemia from Drinking Hyperhydration Solutions at Rest and Exercise

The mechanism of muscular fatigue from physical work and exercise (high metabolism) is not clear, but involves disturbances of muscle surface membrane excitation-contraction coupling from changes in sarcoplasmic reticulum Ca2+ release, cell H+ and Pi responses, and carbohydrate metabolism. Fatigue in people at rest (low metabolism) involves both psychological and physiological factors, probably in different proportions. One common factor appears to be the level and distribution of water and electrolytes within muscle cells and other vascular, interstitial, body fluid compartments. The vascular fluid volume, composed of plasma and red blood cells, is a primary regulatory factor for cardiovascular function; reduction of vascular volume (hypovolemia) and total body water (hypohydration) adversely affect exercise performance. Plasma volume and plasma ionic-osmotic constituent concentrations are also regulatory factors for body thermoregulation, which is often compromised from exercise induced hypovolemia and hypohydration. Rehydration of dehydrated people on earth is relatively easy with appropriate food (osmols), fluid, and a restful environment. But ad libitum drinking under stressful conditions; e.g., heat, exercise, or prior dehydration, results in involuntary dehydration defined as the delay in full fluid replacement (euhydration) during and following loss of body fluid. Astronauts, with their reduced total body water are euhydrated while in weightlessness, but become "dehydrated" during reentry and landing. Thus, people subjected to acute or chronic stress are probably somewhat "dehydrated" as well as fatigued. Many rehydration drinks are more concentrated (hypertonic-hyperosmotic) with respect to the normal plasma osmolality of 285 mOsm/kg H2O and more of the drink osmols are contributed by carbohydrates than by ionized substances. There have been few studies on the efficacy of various drink formulations for increasing body fluid compartment volumes, especially plasma volume, in rested hydrated subjects. Recent findings from our laboratory have indicated that drinks containing greater concentrations of ionized substances (Performance 1 and AstroAde) up to 157 mEq/L Na+ induced greater levels of hypervolemia in resting, moderately dehydrated men, and were also better than water for attenuating the characteristic hypovolemia during supine, submaximal, leg ergometer exercise.

Greenleaf, John E.↗

Generation of large-volume high-pressure plasma by spatiotemporal control of space charge

Any attempt to scale pressure and volume of nonthermal plasma usually leads to instabilities due to the formation of localized space charge. The control of the plasma is limited by the discharge geometry, type of excitation, and gas composition. This article explores the possibility of controlling the space charge in a discharge with a spatially and temporally varying electric field. It is shown that a phase-staggered sinusoidal excitation to a set of conformal azimuthal electrodes in a cylindrical geometry leads to a traveling electric field. Simulations show that in space charge dominated transport, the charged species are dispersed both in the radial and azimuthal directions. This will lead to better control of the space charge and stable discharges near atmospheric pressures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric fields in the solar atmosphere - A review

A review is presented of remote sensing techniques which measure the electric field component transverse to the line of sight and achieve a sensitivity range of 5-10 V/cm. Three models are shown to predict quasistatic, macroscopic values of E(parallel), the electric field component parallel to the magnetic vector, beyond the sensitivity range considered. These processes are: the discharge model of flares; the models of return currents related to flare particle beams; and the models of neutral sheets related to two-ribbon flares and postflare loops. Time dependent electric fields related to MHD and plasma waves, and to plasma disturbance, may allow the detection of both E components (parallel and perpendicular). The uncertainty relating to the emission measures, time scales, volumes, and plasma conditions of these flares and electrified plasma volumes is emphasized. It is pointed out, however, that important information can be obtained by observing electric fields at existing sensitivity levels. By measuring these E-fields, the understanding of flares and related dynamic events can be improved.

Foukal, P.↗

Preliminary feasibility study of pallet-only mode for magnetospheric and plasmas in space payloads, volume 4

Results of studies performed on the magnetospheric and plasma portion of the AMPS are presented. Magnetospheric and plasma in space experiments and instruments are described along with packaging (palletization) concepts. The described magnetospheric and plasma experiments were considered as separate entities. Instrumentation ospheric and plasma experiments were considered as separate entities. Instrumentation requirements and operations were formulated to provide sufficient data for unambiguous interpretation of results without relying upon other experiments of the series. Where ground observations are specified, an assumption was made that large-scale additions or modifications to existing facilities were not required.

Source record↗

Cardiovascular effects of weightlessness and ground-based simulation

A large number of animal and human flight and ground-based studies were conducted to uncover the cardiovascular effects of weightlessness. Findings indicate changes in cardiovascular function during simulations and with spaceflight that lead to compromised function on reambulation and/or return to earth. This altered state termed cardiovascular deconditioning is most clearly manifest when in an erect body state. Hemodynamic parameters inidicate the presence of excessive tachnycardia, hypotension (leading to presyncope in one-third of the subjects), decreased heart volume, decreased plasma and circulating blood volumes and loss of skeletal muscle mass, particularly in the lower limbs. No clinically harmful effects were observed to date, but in-depth follow-ups were limited, as was available physiologic information. Available data concerning the causes for the observed changes indicate significant roles for mechanisms involved with body fluid-volume regulation, altered cardiac function, and the neurohumoral control of the control of the peripheral circulation. Satisfactory measures are not found. Return to preflight state was variable and only slightly dependent on flight duration. Future progress awaits availability of flight durations longer than several weeks.

Sandler, Harold↗

Generation of Large-Volume High-Pressure Plasma by Spatio-Temporal Control of Space Charge

Due to the fundamental limitations of scaling, very little progress has been made towards achieving a large-volume dense non-equilibrium plasma near atmospheric pressures. Commercially available state-of-the art glow-like atmospheric plasma devices for industrial applications are either narrow tubes or wide slits with narrow openings. Often multiple sources are put together in various configurations to process larger surfaces. The traditional methods of exciting electrodes create spatially fixed electric fields. As a result, the space charge at atmospheric pressure tends to be spatially confined resulting in non-uniformity which eventually leads to instability as the discharge is scaled. Theoretical work done under this project showed that it is possible to generate a spatially rotating electric field by exciting a set of electrodes with phase staggered sinusoidal waveforms. The modeling and simulations were done using plasma fluid models. It was shown that such a field can produce a uniform plasma. At the conclusion of the project, experimental proof of concept with an eight-electrode system in various gases (Air, Helium and Argon) was demonstrated. Power measurements and spectral investigation show that the concept can be used to generate a uniform stable plasma. This plasma source has the potential of opening new applications of nonthermal plasma including combustion of carbon-free fuel. The current limitation of the proposed method in scaling to higher volume and pressure is the need for multiple high voltage amplifiers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of 30 day simulated microgravity and recovery on fluid homeostasis and renal function in the rat

Transition from a normal gravitational environment to that of microgravity eventually results in decreased plasma and blood volumes, increasing with duration of exposure to microgravity. This loss of vascular fluid is presumably due to negative fluid and electrolyte balance and most likely contributes to the orthostatic intolerance associated with the return to gravity. The decrease in plasma volume is presumed to be a reflection of a concurrent decrease in extracellular fluid volume with maintenance of normal plasma-interstitial fluid balance. In addition, the specific alterations in renal function contributing to these changes in fluid and electrolyte homeostasis are potentially responding to neuro-humoral signals that are not consistent with systemic fluid volume status. We have previously demonstrated an early increase in both glomerular filtration rate and extracellular fluid volume and that this decreases towards control values by 7 days of simulated microgravity. However, longer duration studies relating these changes to plasma volume alterations and the response to return to orthostasis have not been fully addressed. Male Wistar rats were chronically cannulated, submitted to 30 days heat-down tilt (HDT) and followed for 7 days after return to orthostasis from HDT. Measurements of renal function and extracellular and blood volumes were performed in the awake rat.

Tucker, Bryan J.↗

Plasma viscosity elevations with simulated weightlessness

A hypothesis correlating an increase in blood viscosity during bed rest to a decrease in aerobic capacity during simulated weightlessness is tested. Eight human subjects were studied on the sixth day of bed rest during two consecutive 10-d bed rest periods separated by a 14-d recovery interval designed to simulate the flight-layover schedule of Shuttle astronauts. Plasma viscosity and volume were measured, together with maximal aerobic capacity (VO2max). An increase in hematocrit, plasma protein, and fibrinogen concentrations was found, contributing to an elevation in plasma viscosity. VO2max decreased significantly in the first, but not the second bed rest cycle, and though many individuals exhibited a decrease in plasma volume and aerobic capacity coupled with elevated plasma viscosity, correlations between these variables were lacking. It is concluded that the decrease in VO2max observed following simulated weightlessness cannot be attributed to alterations in muscle blood flow resulting from increased blood viscosity.

Martin, D. G.↗

Laser-induced fluorescence measurements of ion fluctuations in electron and ion presheaths

Electrostatic flow-driven instabilities have been predicted in the presheath region of low-temperature plasmas for both ion and electron rich sheaths. The ion-acoustic fluctuations that arise from these instabilities can influence transport through an enhanced collision rate. In this work, ion fluctuation spectra were measured using laser-induced fluorescence (LIF) in the presheath region for both sheath polarities. Furthermore, the non-invasive nature of LIF compared to that of probes is particularly valuable for these measurements because the sheath and presheath around a probe may generate their own flow-driven instabilities, which obscure the measurement. Measurements were made using a recently implemented field programmable gate array-based system able to measure ion fluctuation spectra up to 1 MHz using a two-point correlation function technique. Narrow bandwidth ion fluctuations were observed near 0:46 f pi (460 kHz) for both sheath polarities, where f pi is the ion plasma frequency. The observed fluctuations were significantly stronger in the electron sheath case and were observed over a larger volume of plasma. Fluctuations were measured in the ion sheath case at locations far enough from the sheath that linear theory predicts stability, suggesting that ion-acoustic instabilities generated in the relatively small unstable region near the boundary reflect from the sheath and perturb a much larger volume of the plasma. This is expected to affect probes with both ion and electron rich sheaths, meaning any dc biased probe may effectively act as an ion-acoustic wave antenna. These measurements are consistent with the recent theory and particle-in-cell results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distribution functions in plasmas generated by a volume source of fission fragments

The role played by fission fragments and electron distribution functions in nuclear pumped lasers is considered and procedures for their calculations are outlined. The calculations are illustrated for a He-3/Xe mixture where fission is provided by the He-3(n,p)H-3 reaction. Because the dominant ion in the system depends on the Xe fraction, the distribution functions cannot be determined without the simultaneous consideration of a detailed kinetic model. As is the case for wall sources of fission fragments, the resulting plasmas are essentially thermal but the electron distribution functions are non-Maxwellian.

Deese, J. E.↗

A Warm Magnetoactive Plasma in a Large Volume of Space

A diffuse ionized warm gas fills a large volume of space in the general direction of Radio Loop II. There are three types of observational evidence: Faraday rotation measures (RM's) of extragalactic sources; emission measures (EM's) derived from the H alpha emission line in the diffuse interstellar medium; and magnetic field strengths in HI clouds derived from Zeeman splitting observations.

Heiles, C.↗