Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 343 records · Page 19

Advanced inorganic halide ceramic scintillators

Research in ceramic scintillators has steadily progressed alongside the research in bulk single crystal scintillator growth. As interest in faster scintillation material production with lower cost increases, more research on scintillating ceramics is needed. Research targeting optimization of optically transparent ceramics that can rival bulk-grown crystals grown may lower cost, increase yield, increase volume, and improve energy resolution in applications and systems currently using sodium iodide and alike. Ceramic scintillators that are dense (>5 g/cm 3 ), have high effective Z (>60), are bright (>40,000 photons/MeV), and are not sensitive to moisture as well as those that can be handled without protection are desired. Ultra-fast ceramic materials are also of interest. This paper presents an equipment design and technique to produce inorganic halide ceramic scintillators Cs 2 HfCl 6 (CHC) and Tl 2 HfCl 6 (THC). Improvements and optimization of CHC and THC ceramic scintillator fabrication are gauged by monitoring the energy resolution and peak position of 137 Cs full energy peak at 662 keV. With a 1-inch diameter CHC ceramic scintillator, energy resolution of 5.4% (FWHM) and light yield of 20,700 ph/MeV are achieved, while with a 16-mm diameter THC ceramic scintillator, energy resolution of 5.1% (FWHM) and light yield of 27,800 ph/MeV are achieved. Decay times of 0.6 μs (21%) and 3.0 μs (79%) are measured for CHC and 0.3 μs (13%) and 1.0 μs (87%) for THC. Here, both ceramic CHC and THC scintillators have similarly good proportionality data when compared to their single crystal counterparts.

36 MATERIALS SCIENCE↗

Global positioning system network analysis with phase ambiguity resolution applied to crustal deformation studies in California

An efficient algorithm is developed for multisession adjustment of GPS data with simultaneous orbit determination and ambiguity resolution. Application of the algorithm to the analysis of data from a five-year campaign in progress in southern and central California to monitor tectonic motions using observations by GPS satellites, demonstrates improvements in estimates of station position and satellite orbits when the phase ambiguities are resolved. Most of the phase ambiguities in the GPS network were resolved, particularly for all the baselines of geophysical interest in California.

Dong, Da-Nan↗

Applications of principal component analysis for energy reconstruction in position-sensitive semiconductor detectors

We report semiconductor detectors with pixelated anodes offer a desirable combination of position sensitivity and energy resolution that are suitable for numerous applications in gamma-ray detection and imaging. Pixelization of electrodes also entails a non-uniform amplitude response as a function of gamma-ray interaction position. Energy calibrations as a function of interaction position improve energy resolution, but systematic errors in the energy reconstruction process persist and limit energy resolution at fixed electronic noise. Digitization of signals induced on collecting and adjacent electrodes offers rich information about gamma-ray interactions and their charge drift and collection as a function of time. Despite the abundance of signals for each interaction, human intuition and rule-based approaches fail to utilize the entire set of observed signals to mitigate the sources of systematic error. In order to maximize the utility of digitized signals and improve energy resolution, principal component analysis is applied towards digitized signals observed in semiconductor detectors with pixelated anodes. Principal components identified in the process form the basis for position-specific energy corrections. By leveraging this additional information encoded within digitized signals, energy resolution improves by factors between 10 and 15% with respect to full-width at half and tenth maximum values. The feature that accounts for the maximum amount of explained variance between interactions in any given pixel correlates strongly with the depth of interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MLC quality assurance using EPID: A fitting technique with subpixel precision

Amorphous silicon based electronic portal imaging devices (EPIDs) have been shown to be a good alternative to radiographic film for routine quality assurance (QA) of multileaf collimator (MLC) positioning accuracy. In this work, we present a method of acquiring an EPID image of a traditional strip-test image using analytical fits of the interleaf and leaf abutment image signatures. After exposure, the EPID image pixel values are divided by an open field image to remove EPID response and radiation field variations. Profiles acquired in the direction orthogonal to the leaf motion exhibit small peaks caused by interleaf leakage. Gaussian profiles are fitted to the interleaf leakage peaks, the results of which are, using multiobjective optimization, used to calculate the image rotational angle with respect to the collimator axis of rotation. The relative angle is used to rotate the image to align the MLC leaf travel to the image pixel axes. The leaf abutments also present peaks that are fitted by heuristic functions, in this case modified Lorentzian functions. The parameters of the Lorentzian functions are used to parameterize the leaf gap width and positions. By imaging a set of MLC fields with varying gaps forming symmetric and asymmetric abutments, calibration curves with regard to relative peak height (RPH) versus nominal gap width are obtained. Based on this calibration data, the individual leaf positions are calculated to compare with the nominal programmed positions. The results demonstrate that the collimator rotation angle can be determined as accurate as 0.01 deg. . A change in MLC gap width of 0.2 mm leads to a change in RPH of about 10%. For asymmetrically produced gaps, a 0.2 mm MLC leaf gap width change causes 0.2 pixel peak position change. Subpixel resolution is obtained by using a parameterized fit of the relatively large abutment peaks. By contrast, for symmetrical gap changes, the peak position remains unchanged with a standard deviation of 0.05 pixels, or 0.026 mm. A trial run of 36 test images, each with gap widths varying from 0.4 to 1.4 mm, were used to analyze 8640 abutments. The leaf position variations were detected with a precision of 0.1 mm at a 95% confidence level, with a mean of 0.04 mm and a standard deviation of 0.03 mm. The proposed method is robust and minimizes the effect of image noise and pixel size and may help physicists to establish reliable and reasonable action levels in routine MLC QA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental energy resolution of a paracentric hemispherical deflector analyzer for different entry positions and bias

A specially designed hemispherical deflector analyzer (HDA) with 5-element input lens having a movable entry position R{sub 0} suitable for electron energy analysis in atomic collisions was constructed and tested. The energy resolution of the HDA was experimentally determined for three different entry positions R{sub 0}= 84, 100, 112 mm as a function of the nominal entry potential V(R{sub 0}) under pre-retardation conditions. The resolution for the (conventional) entry at the mean radius R{sub 0}= 100 mm was found to be a factor of 1.6-2 times worse than the resolution for the two (paracentric) positions R{sub 0}= 84 and 112 mm at particular values of V(R{sub 0}). These results provide the first experimental verification and a proof of principle of the utility of such a paracentric HDA, while demonstrating its advantages over the conventional HDA: greater dispersion with reduced angular aberrations resulting in better energy resolution without the use of any additional fringing field correction electrodes. Supporting simulations of the entire lens plus HDA spectrometer are also provided and mostly found to be within 20%-30% of experimental values. The paracentric HDA is expected to provide a lower cost and/or more compact alternative to the conventional HDA particularly useful in modern applications utilizing a position sensitive detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Velocity profiles of the 2.1 micron H2 emission line in the Orion molecular cloud

Spectra of the H2 nu = 1-0 S(1) emission line in Orion, observed at various positions with a resolution of 20 km/s, are presented. The intrinsic full width at half-maximum of the line ranges from 18 to 58 km/s over the observed positions. Analysis of the line profiles shows that the emitting gas is probably expanding from a region near the BN and KL infrared sources at velocities typically of 40 km/s but as high as 100 km/s, and that it is associated with the source of the broad lines seen in the spectra of many other molecules. Strong constraints are placed on models of the physical processes responsible for the broad emission lines.

Nadeau, D.↗

SU-E-I-88: Mammography Imaging: Does Positioning Matter?

Purpose: In mammography, compression is imperative for quality images and glandular radiation exposure dose. The thickness of the compressed breast directly determines mammography acquisition parameters. The compressed thickness varies due to variation in technologist practice, even for the same patient imaged at different time. This study is to investigate potential effect of the variation in breast positioning on radiation dose and image quality. Methods: Radiation dose at different thicknesses was measured with a BR-12 breast phantom for both conventional craniocaudal view and tomosynthesis in a Hologic Tomosynthesis mammography system. The CIRS stereotactic needle biopsy training phantom embedded dense masses and microcalcification in various sizes were imaged for image quality evaluation. Radiologists evaluated images. Clinical mammograms from the same patient but acquired at different time were retrospectively retrieved to evaluate potential effects of variation in positioning. Results: Acquisition parameters (kVp and mAs) increase with the increased phantom thickness. Radiation exposure increases following an exponential trend. The stereotactic phantom images showed loss of spatial and contrast resolution with inappropriate positioning. The compressed pressure may not be a good indicator for appropriate positioning. The inclusion of different amount of pectoralis muscle may lead to the same compressed pressure but different compressed thickness. The initial retrospective study of 3 patients showed that there were potential large variations in positioning the same patient at different examination time, resulting in large variations in patient radiation dose and image quality. Conclusion: Variations in patient positioning potentially influence patient radiation dose and image quality. The technologist has the critical responsibility to position patient to provide quality images in spite of different breast and body types. To reduce intra and inter practice variations in positioning patient, a training program among each breast imaging center may be a need.

60 APPLIED LIFE SCIENCES↗

Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET

Purpose: Side readout of scintillation light from crystal elements in positron emission tomography (PET) is an alternative to conventional end-readout configurations, with the benefit of being able to provide accurate depth-of-interaction (DOI) information and good energy resolution while achieving excellent timing resolution required for time-of-flight PET. This paper explores different readout geometries of scintillation crystal elements with the goal of achieving a detector that simultaneously achieves excellent timing resolution, energy resolution, spatial resolution, and photon sensitivity. Methods: The performance of discrete LYSO scintillation elements of different lengths read out from the end/side with digital silicon photomultipliers (dSiPMs) has been assessed. Results: Compared to 3 × 3 × 20 mm{sup 3} LYSO crystals read out from their ends with a coincidence resolving time (CRT) of 162 ± 6 ps FWHM and saturated energy spectra, a side-readout configuration achieved an excellent CRT of 144 ± 2 ps FWHM after correcting for timing skews within the dSiPM and an energy resolution of 11.8% ± 0.2% without requiring energy saturation correction. Using a maximum likelihood estimation method on individual dSiPM pixel response that corresponds to different 511 keV photon interaction positions, the DOI resolution of this 3 × 3 × 20 mm{sup 3} crystal side-readout configuration was computed to be 0.8 mm FWHM with negligible artifacts at the crystal ends. On the other hand, with smaller 3 × 3 × 5 mm{sup 3} LYSO crystals that can also be tiled/stacked to provide DOI information, a timing resolution of 134 ± 6 ps was attained but produced highly saturated energy spectra. Conclusions: The energy, timing, and DOI resolution information extracted from the side of long scintillation crystal elements coupled to dSiPM have been acquired for the first time. The authors conclude in this proof of concept study that such detector configuration has the potential to enable outstanding detector performance in terms of timing, energy, and DOI resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LCLS Undulator Commissioning, Alignment, and Performance

The LCLS x-ray FEL has recently achieved its 1.5-Angstrom lasing and saturation goals upon first trial. This was achieved as a result of a thorough pre-beam checkout, both traditional and beam-based component alignment techniques, and high electron beam brightness. The x-ray FEL process demands very tight tolerances on the straightness of the electron beam trajectory (<5 {micro}m) through the LCLS undulator system. Tight, but less stringent tolerances of {approx}100 {micro}m rms were met for the transverse placement of the individual undulator segments with respect to the beam axis. The tolerances for electron beam straightness can only be met through a beam-based alignment (BBA) method, which is implemented using large electron energy variations and sub-micron resolution cavity beam position monitors (BPM), with precise conventional alignment used to set the starting conditions. Precision-fiducialization of components mounted on remotely adjustable girders, and special beam-finder wires (BFW) at each girder have been used to meet these challenging alignment tolerances. Longer-term girder movement due to ground motion and temperature changes are being monitored, continuously, by a unique stretched wire and hydrostatic level Alignment Diagnostics System (ADS).

43 PARTICLE ACCELERATORS↗

Sub-daily resolution of earth rotation variations with Global Positioning System measurements

Data from a worldwide Global Positioning System (GPS) tracking experiment have been used to determine variations in earth rotation (UT1-UTC) over a time period of three weeks. Kalman filtering and smoothing enabled changes in UT1-UTC over intervals of 2 to 24 hrs to be detected with the GPS data. Internal consistency checks and comparisons with other solutions from very long baseline interferometry (VLBI) and satellite laser ranging (SLR) indicate that the GPS UT1-UTC estimates are accurate to about 2 cm. Comparison of GPS-estimated variations in UT1-UTC with 2-hr time resolution over 4 days with predicted variations computed from diurnal and semidiurnal oceanic tidal contributions strongly suggests that the observed periodic sub-daily variations of about 0.1 msec are largely of tidal origin.

Lichten, Stephen M.↗

Detector density and small field dosimetry: Integral versus point dose measurement schemes

Purpose: TheAlfonso et al. [Med. Phys.35, 5179–5186 (2008)] formalism for small field dosimetry proposes a set of correction factors (k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}) which account for differences between the detector response in nonstandard (clinical) and machine-specific-reference fields. In this study, the Monte Carlo method was used to investigate the viability of such small field correction factors for four different detectors irradiated under a variety of conditions. Because k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values for single detector position measurements are influenced by several factors, a new theoretical formalism for integrated-detector-position [dose area product (DAP)] measurements is also presented and was tested using Monte Carlo simulations. Methods: A BEAMnrc linac model was built and validated for a Varian Clinac iX accelerator. Using the egs++ geometry package, detailed virtual models were built for four different detectors: a PTW 60012 unshielded diode, a PTW 60003 Diamond detector, a PTW 31006 PinPoint (ionization chamber), and a PTW 31018 MicroLion (liquid-filled ionization chamber). The egs-chamber code was used to investigate the variation ofk{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} with detector type, detector construction, field size, off-axis position, and the azimuthal angle between the detector and beam axis. Simulations were also used to consider the DAP obtained by each detector: virtual detectors and water voxels were scanned through high resolution grids of positions extending far beyond the boundaries of the fields under consideration. Results: For each detector, the correction factor (k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}) was shown to depend strongly on detector off-axis position and detector azimuthal angle in addition to field size. In line with previous studies, substantial interdetector variation was also observed. However, it was demonstrated that by considering DAPs rather than single-detector-position dose measurements the high level of interdetector variation could be eliminated. Under small field conditions, mass density was found to be the principal determinant of water equivalence. Additionally, the mass densities of components outside the sensitive volumes were found to influence the detector response. Conclusions: k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} values for existing detector designs depend on a host of variables and their calculation typically relies on the use of time-intensive Monte Carlo methods. Future moves toward density-compensated detector designs or DAP based protocols may simplify the methodology of small field dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Mexico city aerosol analysis during MILAGRO using high resolution aerosol mass spectrometry at the urban supersite (T0) - Part 2: Analysis of the biomass burning contribution and the non-fossil carbon fraction

Submicron aerosol was analyzed during the MILAGRO field campaign in March 2006 at the T0 urban supersite in Mexico City with a High-Resolution Aerosol Mass Spectrometer (AMS) and complementary instrumentation. Positive Matrix Factorization (PMF) of high resolution AMS spectra identified a biomass burning organic aerosol (BBOA) component, which includes several large plumes that appear to be from forest fires within the region. Here, we show that the AMS BBOA concentration at T0 correlates with fire counts in the vicinity of Mexico City and that most of the BBOA variability is captured when the FLEXPART model is used for the dispersion of fire emissions as estimated from satellite fire counts. The resulting FLEXPART fire impact factor (FIF) correlates well with the observed BBOA, acetonitrile (CH3CN), levoglucosan, and potassium, indicating that wildfires in the region surrounding Mexico City are the dominant source of BBOA at T0 during MILAGRO. The impact of distant BB sources such as the Yucatan is small during this period. All fire tracers are correlated, with BBOA and levoglucosan showing little background, acetonitrile having a well-known tropospheric background of {approx}100-150 pptv, and PM2.5 potassium having a background of {approx}160 ng m3 (two-thirds of its average concentration), which does not appear to be related to BB sources. We define two high fire periods based on satellite fire counts and FLEXPART-predicted FIFs. We then compare these periods with a low fire period when the impact of regional fires is about a factor of 5 smaller. Fire tracers are very elevated in the high fire periods whereas tracers of urban pollution do not change between these periods. Dust is also elevated during the high BB period but this appears to be coincidental due to the drier conditions and not driven by direct dust emission from the fires. The AMS oxygenated organic aerosol (OA) factor (OOA, mostly secondary OA or SOA) does not show an increase during the fire periods or a correlation with fire counts, FLEXPART-predicted FIFs or fire tracers, indicating that it is dominated by urban and/or regional sources and not by the fires near the MCMA. A new 14C aerosol dataset is presented. Both this new and a previously published dataset of 14C analysis suggest a similar BBOA contribution as the AMS and chemical mass balance (CMB), resulting in 13% higher non-fossil carbon during the high vs. low regional fire periods. The new dataset has {approx}15% more fossil carbon on average than the previously published one, and possible reasons for this discrepancy are discussed. During the low regional fire period, 38% of organic carbon (OC) and 28% total carbon (TC) are from non-fossil sources, suggesting the importance of urban and regional non-fossil carbon sources other than the fires, such as food cooking and regional biogenic SOA. The ambient BBOA/CH3CN ratio is much higher in the afternoon when the wildfires are most intense than during the rest of the day. Also, there are large differences in the contributions of the different OA components to the surface concentrations vs. the integrated column amounts. Both facts may explain some apparent disagreements between BB impacts estimated from afternoon aircraft flights vs. those from 24-h ground measurements. We show that by properly accounting for the non-BB sources of K, all of the BB PM estimates from MILAGRO can be reconciled. Overall, the fires from the region near the MCMA are estimated to contribute 15-23% of the OA and 7-9% of the fine PM at T0 during MILAGRO, and 2-3% of the fine PM as an annual average. The 2006 MCMA emissions inventory contains a substantially lower impact of the forest fire emissions, although a fraction of these emissions occur just outside of the MCMA inventory area.

09 BIOMASS FUELS↗

Space-resolved extreme ultraviolet spectrometer for impurity emission profile measurement in Large Helical Device

A space-resolved extreme ultraviolet (EUV) spectrometer working in 60-400 A range has been developed to observe impurity emission profiles in core and edge plasmas of Large Helical Device (LHD). A flat focus is made for plane surface detector by using a varied line spacing holographic grating with an angle of incidence of 87 deg. An excellent spectral resolution of 0.22 A at 200 A is then obtained after careful adjustment of the optical components. In the profile measurement of the LHD plasmas, the toroidal resolution is important as well as the radial resolution because the magnetic surfaces of LHD quickly change when the observation chord is tilted at a slightly different toroidal location. Horizontal dispersion is therefore selected for the present spectrometer. As a result, the toroidal resolution of 75 mm is achieved at the plasma position. An enough radial resolution of 10 mm is also obtained at spatial-resolution slit width of 0.2 mm. In order to measure the full radial profile of LHD plasmas the spectrometer is placed at a distance of {approx}9200 mm away from the plasma center and a backilluminated charge-coupled device with a size of 6.6x26.6 mm{sup 2} is set vertical to the horizontal dispersion. Half of the LHD plasma, i.e., {approx}50 cm, can be measured along the vertical direction at horizontally elongated plasma cross section. A full vertical profile can be obtained by changing the vertical angle of the EUV spectrometer. As an example the full vertical profile of edge C IV (312.4 A) emission is presented. A wavelength interval of 35-65 A can be simultaneously observed, which varies according to the wavelength to be measured. A local emission profile of Fe XX (132.67 A) is also presented after Abel inversion as a typical example of the core EUV emission. Finally, the EUV spectrometer is absolutely calibrated using EUV bremsstrahlung continuum profile in comparison with absolute values of visible bremsstrahlung continuum profile because the bremsstrahlung continuum can be easily detected in high-density discharges of LHD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced x-ray imaging spectrometer

An x-ray spectrometer that also provides images of an x-ray source. Coded aperture imaging techniques are used to provide high resolution images. Imaging position-sensitive x-ray sensors with good energy resolution are utilized to provide excellent spectroscopic performance. The system produces high resolution spectral images of the x-ray source which can be viewed in any one of a number of specific energy bands.

Callas, John L.↗

Observation of super-resolution in digital breast tomosynthesis

Purpose: Digital breast tomosynthesis (DBT) is a 3D x-ray imaging modality in which tomographic sections of the breast are generated from a limited range of tube angles. Because oblique x-ray incidence shifts the image of an object in subpixel detector element increments with each increasing projection angle, it is demonstrated that DBT is capable of super-resolution (i.e., subpixel resolution). Methods: By convention, DBT reconstructions are performed on planes parallel to the breast support at various depths of the breast volume. In order for resolution in each reconstructed slice to be comparable to the detector, the pixel size should match that of the detector elements; hence, the highest frequency that can be resolved in the plane of reconstruction is the alias frequency of the detector. This study considers reconstruction grids with much smaller pixelation to visualize higher frequencies. For analytical proof of super-resolution, a theoretical framework is developed in which the reconstruction of a high frequency sinusoidal input is calculated using both simple backprojection (SBP) and filtered backprojection. To study the frequency spectrum of the reconstruction, its Fourier transform is also determined. The experimental feasibility of super-resolution was investigated by acquiring images of a bar pattern phantom with frequencies higher than the detector alias frequency. Results: Using analytical modeling, it is shown that the central projection cannot resolve frequencies exceeding the detector alias frequency. The Fourier transform of the central projection is maximized at a lower frequency than the input as evidence of aliasing. By contrast, SBP reconstruction can resolve the input, and its Fourier transform is correctly maximized at the input frequency. Incorporating filters into the reconstruction smoothens pixelation artifacts in the spatial domain and reduces spectral leakage in the Fourier domain. It is also demonstrated that the existence of super-resolution is dependent on position in the reconstruction and on the directionality of the input frequency. Consistent with the analytical results, experimental reconstructions of bar patterns showed visibility of frequencies greater than the detector alias frequency. Super-resolution was present at positions predicted from analytical modeling. Conclusions: This work demonstrates the existence of super-resolution in DBT. Super-resolution has the potential to impact the visualization of fine structural details in the breast, such as microcalcifications and other subtle signs of cancer.

60 APPLIED LIFE SCIENCES↗

Motion control of 7-DOF arms - The configuration control approach

Graphics simulation and real-time implementation of configuration control schemes for a redundant 7-DOF Robotics Research arm are described. The arm kinematics and motion control schemes are described briefly. This is followed by a description of a graphics simulation environment for 7-DOF arm control on the Silicon Graphics IRIS Workstation. Computer simulation results are presented to demonstrate elbow control, collision avoidance, and optimal joint movement as redundancy resolution goals. The laboratory setup for experimental validation of motion control of the 7-DOF Robotics Research arm is then described. The configuration control approach is implemented on a Motorola-68020/VME-bus-based real-time controller, with elbow positioning for redundancy resolution. Experimental results demonstrate the efficacy of configuration control for real-time control.

Seraji, Homayoun↗

Preliminary Modeling of CH3D From 4000 to 4550 cm (exp-1)

A new study of 12CH3D line positions and intensities was performed for the upper portion of the Enneadecad polyad between 4000 and 4550/cm. For this, FTIR spectra were recorded with D-enriched methane samples (at 80 K with a Bruker 125 IFS at 0.005/cm resolution and at 291 K with the McMath-Pierce FTS at 0.011/cm resolution, respectively). Line positions and intensities were retrieved by least square curve-fitting procedures and analyzed using the effective Hamiltonian and the effective dipole moment expressed in terms of irreducible tensor operators adapted to symmetric top molecules. Initially, only the cold spectrum was used to identify quantum assignments and predict 12CH3D relative intensities in this region. To assign higher quanta up to J equal 14, additional line positions and intensities were obtained from two room temperature spectra. In the final stage, measured intensities from both the cold and the room temperature data were normalized to corresponding values at 296 K and then averaged. Combining the two temperature datasets confirmed the assumed quantum assignments and also demonstrated the relative accuracies to be better than 70.0002/cm for line positions and at least +/-6% for intensities so that approx.1160 features were selected. Including additional assignments from the room temperature spectra alone permitted 1362 line intensities of 11 bands (involving 23 vibrational symmetry components) to be reproduced with an RMS of 9%. Over 4085 selected positions for 12 bands were modeled to 0.008/cm. Nevertheless a number of known assignments could not be modeled to within our experimental precisions. More work is needed to obtain a complete characterization of this complex polyad.

Nikitin, A. V.↗